Вы находитесь на странице: 1из 2

The reproduction, transmission or use of this document or ist contents is not permitted without express written authority.

Offenders will be liable for damages.


All rights including rights created by patent grant or registration of a utility model or design are reserved.
Copyright reserved.

1. Safety Test 2.1 Fault memory display


For the safety test, heating element must be switched on. The test must be done using residual current method. Test: Sequence: Display:
For this propose the following inspection process is adaptive: Last fault - The last fault is displayed at first Standard indicators FILTER and
1. Connect appliance with the tester and power line DOOR OPEN are flashing
2. Choose program with heater, for example Cotton Extra Dry Fault history
3. Program start - After pressing the START button, the content of the error register is indicated Standard indicators off
4. Check the current consumption on the tester (motor and heating elements must be switched on) (32 register)
5. The maximum residual current must be under allowable limit while checking proceure is running. Last fault
Annotation: - if all register were indicated, the last fault is displayed again by pressing Standard indicators FILTER and
Depending on used tester (for example Meratester 5-f), it could be necessary that the inspection process has to be repeated the START button DOOR OPEN are flashing
with 180° twisted power connector.
The inspection process must be done witha cold appliance to be sure that the heater element is switched on. Status indicators Fault / fault description Remarks Results
DRYING DAMP DRY REGULAR WRINKLE possible cause
2. Selecting the test program DRY BLOCK / END
Observe correct method for setting program selector! - No fault
Display is flashing - Fluffing level 1 - Fluff filter or air routes - Clean components and
Activation of LED LEDs Status indicators blocked air routes
test mode: START button DRYING DAMP DRY REGULAR WRINKLE is flashing - Fluffing level 2 - Fluff filter or air routes - Clean components and
DRY BLOCK / END blocked air routes
- Set prgram selector to OFF position. is flashing is flashing - Maximum drying time - Heater or heater control - Check heating circuit and
- Set prgram selector to position 6:00 o'clock. slow exceeded damaged bimetal switch
- Keep delicates button pressed while turning is flashing - Bimetal switch was - Replace damaged parts
program selector (clockwise) to the next quick triggered
position - Laundry load - Reduce laundry load or
- Let delicates button go (to heavy or to wet) select adequate program
Select - In the test mode, set program selector to a is flashing is flashing is flashing - Not defined
test program: wanted test program: quick is flashing is flashing - Fault in heating circuit - Excess temperature of - check air routes, heater
Program P:01 is illuminating heater is detected function and heater control
 Fault memory display (see 2.1) - replace damaged parts
Program P:02 is illuminating is flashing is flashing is flashing - Not defined
 RAM- and ROM test (see 2.2) is flashing - Door-NTC fault (TD) - Damaged sensor - Check wires and connectors
Program P:03 is illuminating is illuminating - Short circuit in sensor - Replace damaged parts
 Indicator (LEDs + LCD) test (see 2.2) wire - Short circuits and breaks are
Program P:04 is illuminating - Open sensor circuit detected by control after
 Operating elements (see 2.4) - Control interpretation switch on
Program P:05 is illuminating is illuminating fault
 Conductometry (see 2.5) ⊗ is flashing is flashing - Heater-NTC fault (TH) - No temperature rise - Check heating circuit and
Program P:06 is illuminating is illuminating after program start bimetal switch
 Component motor/heater (see 2.6) - Break in heater circuit - Replace damaged parts
Program P:07 - Damaged sensor - Check sensor wire and
 Not used (no error) - Short circuit in sensor connectors
Program P:13 is illuminating is illuminating is illuminating wire - Short circuits and breaks of
 Variant coding (see 2.7) - Open sensor circuit the sensor are
Program P:14 is illuminating is illuminating is illuminating - Control interpretation detected by control after
 VT Update fault switch on
Start - Press START button ⊗ is flashing is flashing - Control fault 1 - Process software set - Update software or
test program: (Update invalid) is incorrect programed replace control
Abort - Adjust program selector or press ⊗ is flashing is flashing is flashing - Control fault 2 - Control fault is - Replace control
test program: START button detected
- Switch off appliance at is flashing is flashing - Variant coding fault - Incompatible variant - Replace the wrong variant
Program P:04 coding for that control coding with the right one
 Operating elements - Use program P:13
Fault in Indication of last error (see 2.1)
test program: 2.2 RAM- and ROM test
Leave - Switch off appliance Test: Sequence: Display:
test program: - Program works in bachground automatically LED START button is illuminating
In case of fault (see 2.1), the buzzer
⊗ Fault is optional available is activated
- Program ends automatically after approx. 30sec LED START button is flashing
and returns into test mode (see 2.)

Designation: LCS: Document No.: Rev.: Sheet-No.:

Test Program 1
EN 5500 0000031539 A,1 of:

Material No.:
2
V20-UL ( TE26 ) 9000246935
01.06.2007
The reproduction, transmission or use of this document or ist contents is not permitted without express written authority.
Offenders will be liable for damages.
All rights including rights created by patent grant or registration of a utility model or design are reserved.
Copyright reserved.

2.3 Indicator test (LEDs) 2.6 Component motor/heater


Test: Sequence: Display: Test: Sequence: Anzeige:
- All LEDs are illuminating continously for 4sec LEDs are illuminating - Operating sequence for motor and heater - see tables below
- All LEDs are activated successive in 0,5sec steps LEDs are illuminating successive
in 0,5sec steps 2.6.1 Operating sequence with voltage setting to "lo" (208V variant)
- Sequence starts again Time in sec, absolute 0 5 10 15 20 25 30 35 40 45 50 55 60 65
Duration in sec 5 10 10 10 30 0
2.4 Operating elements LED DRYING X X
Test: Sequence: Display: LED DUMP DRY X X X
START button - Press START button LED START button is illuminating LED REGULAR DRY X X
OPTION button - Press an OPTION button LED of the pressed button is illuminating Display :1 :2 :3 :4 :6
Buzzer - Keep LOW HEAT button pressed Continous output of the acoustic signal Motor
on
in 6 sound level steps (sound level 0 incl.)
off
Program selector - Select each position with the program selector LEDs are illuminating (see table below)
Heater E1
on
LEDs or display symbol Program selector position
off
Off 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Off
Drying X X X X X X X X Heater E3
on
Damp Dry X X X X X X X X
off
Regular Dry X X X X X X X X
Wrincle Block / End X X X X X X X X
2.6.2 Operating sequence with current voltage setting to "hi" (240V variant)
2.5 Conductometry Time in sec, absolute 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
Test description: Sequence: Remarks: Duration in sec 5 10 10 10 10 30 0
- Open the dryer door LED DRYING X X X
- The function of the inductance can be tested by making a short circuit LED DUMP DRY X X X
between electrodes and drum LED REGULAR DRY X X X
LED DRYING LED DAMP DRY Display :1 :2 :3 :4 :5 :6
- Drum empty, no Fault! There is a bypass in measuring Motor
H H on
connection between circuit
off
conductance electrode No fault
T H
and drum Heater E1
on
Fault! There is a bypass or short circuit in
H T off
measuring circuit
- Bypass on conductance No fault Heater E3
H H on
electrode with hand, or
off
define resistance of Fault! There is an open circuit or re-
T H
100kΩ ... 1MΩ sistance in measuring circuit is too high
Fault! There is a bypass or short circuit in 2.7 Variant coding
H T
measuring circuit Display
- Electrical connection Fault! There is an open circuit or re- Select - In variant coding mode, press START button to switch
between conductance H H sistance in measuring circuit is too high variant: through variants:
electrode and drum  Button variant (Value range 1...8) LED FILTER is illuminating
 Program selector variant (Value range 1...6) LED DOOR OPEN is illuminating
Setting of - The variant is incremented and stored by pressing the delicates button Status indicator LEDs are illuminating
variant: see table below

Button variant
Program selector variant
LEDs or display symbol 1 2 3 4 5 6 7 8
Drying X X X X
Damp Dry X X X X
Regular Dry X X X X
Wrincle Block / End X

Designation: LCS: Document No.: Rev.: Sheet-No.:

Test Program 2
EN 5500 0000031539 A,1 of:

Material No.:
2
V20-UL ( TE26 ) 9000246935
01.06.2007

Вам также может понравиться