Вы находитесь на странице: 1из 4

Measurement Uncertainty for HARDNESS ROCKWELL EMS/HRB/SAMPLE

Sources of Uncertainty
W1 W2 W3 W4 W5 Avg Stdev
Work Piece (in HRB ) 90.1 90.3 90 90.3 90.1 90 0.1342

Calibration Uncertainty of 1.26 % of 90.2 HRB as given in the calibration


0.577
hardness block certificate

Calibration Uncertainty of OF
0.93 0.93 as given in the calibration certificate
HARDNESS MACHINE

Calculation of Uncertainty

Sources of Uncertainty Type Ui Value Divisor Standard Uncertainty Remarks

U1 = SD/square root of 5 No.


Work piece A U1 0.1342 2.2361 0.060016
pieces

Uncertainty due to CRM B U2 0.5770 1.7321 0.333122 U2 = UNCERTAINTY DUE TO CRM

Calibration Uncertainty of OF U3 = UNCERTAINTY DUE TO MAC


B U3 0.9300 2.0000 0.465000
HARDNESS MACHINE

Square root of sum of squar


Combined Uncertainty 0.5751
individual standard uncerta

Combined relative Uncertain


Expanded Uncertainty 1.1503
factor (i.e.2 )
EXPANDED UNCERTAINTY of HARDNESS (HRB 90) ± 1.1503

EMS
Doc No : EMS / QF / 05.4.01 QUALITY FORMAT
Issue No: 1/ Issue Date :- 03/04/2014 Amend No. /Amend Date : - Page 1 of 1
Prepared by : Approved by : Issued by :
B/SAMPLE

Remarks

/square root of 5 No. of work

CERTAINTY DUE TO CRM/ROOT OF 3

CERTAINTY DUE TO MACHINE/2

root of sum of squares of


dual standard uncertainties

ed relative Uncertainty x Coverage


(i.e.2 )
1
y: