Вы находитесь на странице: 1из 1

Fuller® Automated Transmissions Fuller® Automated Transmissions

More time on the road More time on the road


TM TM

Fault Code Retrieval/Clearing Fault Code Index


AutoShift™ Gen2 AutoShift™ Gen2
Retrieving Fault Codes Fault Codes Description
1. Place the shift lever in neutral. 11 Shift Control
12 Transmission Controller
2. Set the parking brake. 14 Invalid Lever Position
16 Eaton Proprietary Link (EPL)
3. T urn the ignition key ON but do not start the engine. If the engine is
already running, you may still retrieve codes, however, do not engage 17 Start Enable Relay Coil
the starter if engine stalls. 25 No Codes
32 Switched System Voltage
4. To Retrieve Active Codes: Start with the key in the ON 2 TIMES
33 Battery Voltage Supply
position. Turn the key OFF and ON two times within
five seconds ending with the key in the ON position. 35 J-1939 Data Link
OFF ON
After five seconds, the service lamp begins flashing 41 Range Failed to Engage
two-digit fault codes. If no codes are active, the 42 Splitter Failed to Engage
service light will flash code 25 (no codes). 43 Range Valve
44 Inertia Brake Solenoid Coil
4 TIMES  Retrieve Inactive Codes: Start with the key in the
To
46 Splitter Valve
ON position. Turn the key OFF and ON four times
OFF ON within five seconds ending with the key in the ON 51 Rail Select Sensor
position. After five seconds, the service lamp begins 52 Gear Select Sensor
flashing two-digit fault codes. If no codes are active, 56 Input Shaft Speed Sensor
the service light will flash code 25 (no codes). 57 Main Shaft Speed Sensor
58 Output Shaft Speed Sensor
5. O
 bserve the sequence of flashes on the indicator lamp and record the
codes. A one or two second pause separates each store code, and the 61 Rail Select Motor
sequence automatically repeats after all codes have been flashed. 63 Gear Select Motor
65 Logic Power
Clearing Fault Codes 71 Stuck Engaged
72 Failed to Select Rail
1. S
 tart with the key in the ON position. Turn the key OFF 6 TIMES
73 Failed to Engage Gear
and ON six times within five seconds, ending with the
key in the ON position. 74 Failed to Synchronize
OFF ON
83 Shift Lever Missing
Note: If the codes have been successfully cleared, 91 Check of the Wiring Integrity
the service lamp will come on and stay on for five 92 Weak Voltage in System
seconds.
93 Loss of J1939 Communication
2. Turn the key OFF and allow system to power down.

©2006 Eaton Corporation · All rights reserved. Eaton Truck Components, Kilsyth, Victoria, 3137 Australia.
Printed in Australia. EA10353AU 10/07 www.roadranger.com

Вам также может понравиться