Вы находитесь на странице: 1из 29

20180802

SINE
NG
EL
EC
TR
IC
C
O

.,
LT
D
.
D.
, LT
C O.
IC
TR
C
LE
E

G
N
E
N
SI
Sineng Electric Co., Ltd.
No. 6 Hehui Road, Huishan District,214174,China.
Sineng Electric (India) Pvt Ltd.
Plot No. 56 & 57, Bommasandra-Jigani Link Road, Industrial Area, Excellent
PV Inverter Catalogue
+86 510 83583123 Bangalore, Karnataka, 560099, India. Sineng
www.si-neng.com Sales.India@si-neng.com
Pioneers in Solar Inverters
Contents

Company Introduction 01

As one of the leading inverter manufacturers in the world,Sineng has acquired fortune 500 company’s solar division and integarated Central Inverter Series 03-04
their advanced experience in inverter technology that has contributed to Sineng becoming top 5 solar inverter manufacturer globally.
System Solution 05-08
In order to providing proactive services and competitive solutions,Sineng localized solar inverter manufacturing and service in
Bangalore,which effectively maximize service availability and product performance. Specification 09-24

Featuring one of the widest portfolios of solar inverters ranging from single- and three-phase string inverters up to MW central invert-
1500V - EP-3250/3125/3000/2750/2500-HA-UD EP-2500-HA-OD
ers and central distributed inverters (Multi-MPPT) makes Sineng inverter suitable for the small residential photovoltaic systems right
up to multi-MW solar power plants. EP-2500-HA-OD/35 EP-1000/1250-HA

Till date,Sineng solar inverters are widely installed in large scale ground,hilly terrain,water surface,roofs of commercial and residen-
1000V - EP-1250-AI EP-2500-AI-OD EP-2500-AI-OD/35
tial buildings etc.

Sineng is helping people generate more energy around the world.

Central Distributed Inverter Series 25-26

System Solution 27-34

Specification 35-42

CP Inverter - CP-1000-B CP-1000-B-OD CP-2000-B-OD CP-2000-B-OD/35

Intelligent MPPT Optimizer - EJB-16-M4 EJB-24-M4

String inverter Series 43

System Solution 44

Specification 45-56

SP-60K-L SP-45K SP-40K SP-20K SP-5000 SP-3000

Copyright 2018 SINENG. All rights reserved.


01 Specifications subject to change without notice. 02
Central Inverter Series

1500V Central Solar Inverter 1000V Central Solar Inverter

EP-1000/1250-HA EP-2500-HA-OD

EP-1250-AI EP-2500-AI-OD EP-2500-AI-OD/35

EP-2500-HA-OD/35 EP-3125/3000/2850/2600-HA-UD

Feature

Advanced efficiency, high yield Industrial oriented design for harsh environment Grid friendly and support (L/HVRT, Active and reactive power control)
Good quality components, high reliability Anti-PID solution effectively prevent module PID effect Good quality components, high reliability

Copyright 2018 SINENG. All rights reserved.


03 Specifications subject to change without notice. 04
10MW/12.5MW typical block size System Solution

Centralized
Control Center Sienergy
Monitoring AC power cable
Intelligent Energy Grid Dispatch Center Grid
cloud
Cloud Platform
DC power cable
PC
Communication cable

Router
APP

Firewall

Recommended Application Scenarios

Core switch Large ground PV plant


10~35kV
Agricultural PV complementary power plant
Water area PV plant
……

Fiber Switch Fiber Switch


Transformer Transformer
12.5MVA 10MVA

Large block size, lower initial


investment, convenient O&M
SAU-100 SAU-100

Centralized connection to grid,good


3.125MWac 3.125MWac 3.125MWac 3.125MWac 2.5MWac 2.5MWac 2.5MWac 2.5MWac adaptability to grid without the risk
of resonance

Inverter

Built-in SVG function save the cost


of SVG device

DC Combiner
Reserved interface for
DC storage energy

Smart management platform with


PV module intelligent analysis and protection,
fault alarm, O&M information ect

block 1# block N#

Copyright 2018 SINENG. All rights reserved.


05 Specifications subject to change without notice. 06
5MW/6.25MW typical block size system solution

Centralized
Control Center Sienergy AC power cable
Monitoring
Intelligent Energy Grid Dispatch Center
cloud
Cloud Platform
DC power cable
PC
Communication cable

Router
APP

Firewall

Recommended Application Scenarios

Core switch
Large ground PV plant
10~35kV
Agricultural PV complementary power plant
Water area PV plant
……

Fiber Switch 6.25MVA Fiber Switch


Transformer Transformer 5MVA

Large block size, lower initial


investment, convenient O&M

SAU-100 SAU-100

Centralized connection to grid,good


adaptability to grid without the risk
of resonance

Inverter 3.125MWac 3.125MWac 2.5MWac 2.5MWac

Built-in SVG function save the cost


of SVG device

DC Combiner Reserved interface for


DC storage energy

Smart management platform with


intelligent analysis and protection,
PV module
fault alarm, O&M information ect

block 1# block N#

Copyright 2018 SINENG. All rights reserved.


07 Specifications subject to change without notice. 08
EP-3250/3125/3000/2750/2500-HA-UD Model EP-3250-HA-UD EP-3125-HA-UD EP-3000-HA-UD EP-2750-HA-UD EP-2500-HA-UD
EP series 1500V central solar inverter Input ( DC )
Max.PV input voltage 1500V 1500V 1500V 1500V 1500V

Max. input current 4079A 4106A 4023A 4034A 4034A

MPP voltage range for nominal power 935~1300V 893~1300V 875~1300V 800~1300V 800~1300V
More power generation Number of MPPT trackers 1 1 1 1 1
Max. efficiency 99%, Euro efficiency 98.7%
Number of DC inputs 16~24 16~24 16~24 16~24 16~24
Full power operation without derating at 50℃
1500Vdc PV system reduce power loss Output ( AC )
Rated AC output power 3250kW 3125kW 3000kW 2750kW 2500kW

Max. output power 3738kW 3594kW 3450kW 3163kW 3163kW

Rated grid voltage 660V 630V 600V 550V 550V

Grid voltage range 561~726V 536~693V 510~660V 468~605V 468~605V


Low system cost
Outdoor design without container Rated output current 2843A 2864A 2887A 2887A 2624A
Convenient for large block size PV plant
Max. output current 3270A 3294A 3320A 3320A 3320A
High DC/AC ratio up to 1.5
Rated grid freqency/range 50Hz±5Hz, 60Hz±5Hz 50Hz±5Hz, 60Hz±5Hz 50Hz±5Hz, 60Hz±5Hz 50Hz±5Hz, 60Hz±5Hz 50Hz±5Hz, 60Hz±5Hz

THDi <3% <3% <3% <3% <3%

DC current injection <0.5%In <0.5%In <0.5%In <0.5% In <0.5% In

Power factor(at norminal power) >0.99/-0.8~+0.8 >0.99/-0.8~+0.8 >0.99/-0.8~+0.8 >0.99/-0.8~+0.8 >0.99/-0.8~+0.8


High reliability
Capacitor life prediction technology Protection
DC Break plus current sensor for Circuit breaker
zone current monitoring and protection DC input protection Circuit breaker Circuit breaker Circuit breaker Circuit breaker
Key componet at front side, easy for maintenance AC output protection Circuit breaker Circuit breaker Circuit breaker Circuit breaker Circuit breaker

Overvoltage protection DC Type II/AC Type II DC Type II/AC Type II DC Type II/AC Type II DC Type II/AC Type II DC Type II/AC Type II

Leakege current monitoring Yes Yes Yes Yes Yes

Ground fault monitoring Yes Yes Yes Yes Yes

Grid monitoring Yes Yes Yes Yes Yes


Grid friendly
LVRT and HVRT function Insulation monitoring Yes Yes Yes Yes Yes
Active & reactive power dispatch Overheat protection Yes Yes Yes Yes
Yes
SVG function Yes Yes Yes Yes Yes

Anti-PID function Yes Yes Yes Yes Yes

Smoke detecting Yes Yes Yes Yes Yes

Efficiency
Max. efficiency 99.00% 99.00% 99.00% 99.00% 99.00%
Circuit EU efficiency 98.70% 98.70% 98.70% 98.70% 98.70%

General date
Self-consuming at runtime <3000W <3000W <3000W <3000W <3000W
DC breaker
Self-consuming in standby/night <200W/100W <200W/100W <200W/100W <200W/100W <200W/100W
Inverter Circuit AC contactor AC breaker

Protection level IP54 IP54 IP54 IP54 IP54


DC1

(1)
-

Temperature -30℃~+60℃ -30℃~+60℃ -30℃~+60℃ -30℃~+60℃ -30℃~+60℃


A
DC AC
AC Fan cooling
EMI DC/AC EMI B Cooling mode Fan cooling Fan cooling Fan cooling Fan cooling
Filter
Filter Filter (2)
C Altitude at full load 3000m 3000m 3000m 3000m 3000m

Display LCD LCD LCD LCD LCD


- +
DC18

Communication port RS485/Ethernet RS485/Ethernet RS485/Ethernet RS485/Ethernet RS485/Ethernet


DC SPD
Certificates and approvals (more available on request) IEC 62109, IEC 61727, IEC 61683, IEC 62116, IEC 60068, IEC 61000
DC breaker AC SPD
Dimensions (W×H×D) 2350×2153×1200mm 2350×2153×1200mm 2350×2153×1200mm 2350×2153×1200mm 2350×2153×1200mm

Weight 2500kg 2500kg 2500kg 2500kg 2500kg

(1) When ambient temperature is under -30℃, the inverter needs to configure with heater (optional)
(2) When above 3000m, the converter begins derating, contact us for derating parameters

Copyright 2018 SINENG. All rights reserved.


09 Specifications subject to change without notice. 10
EP-2500-HA-OD
EP Series 1500V Central Solar Inverter

Input parameters
Max. PV input voltage 1500V

Max. input current 2×1754A

MPP voltage range for nominal power 800~1300V


More power generation
Max. efficiency 99%, Euro efficiency 98.7% Number of MPPT trackers 2

Full power operation without derating at 50℃ Number of DC inputs 20~24


1500Vdc PV system reduce power loss Output parameters
Rated output power 2500kW

Max. output power 2750kW

Rated grid voltage 550V

Low system cost Grid voltage range 468~605V


IP54 container solution without house Max. output current 2×1443A
Auxiliary power supply and communication integrated
Rated grid frequency / range 50 Hz/45~55Hz, 60Hz/55~65Hz
Integrated reactive power compensation
High DC/AC ratio up to 1.5 Output current harmonic(at nominal power) <3%

Power factor at nominal power / range >0.99/0.8 lagging to 0.8 leading

Protection
DC input protection Circuit breaker
High reliability AC output protection Circuit breaker
Key components online monitoring
Overvoltage protection DC Type II/AC Type II
Redundancy design for cooling fans and
control power supply Leakege current monitoring Yes

Industry oriented design for harsh enviroment Ground fault monitoring Yes

Insulation monitoring Yes

Overheat protection Yes

Reactive power compensation Optional

Anti-PID function Optional


Grid friendly
Smoke detecting Yes
LVRT and HVRT function
Low harmonics and fast response for grid regulation Efficiency
Max. efficiency 99%

EU efficiency 98.70%

General date
Self-consuming at runtime <2500W

Self-consuming in standby <80W

Protection level IP54


Circuit (1)
temperature -30℃~+60℃

DC breaker Cooling mode Temperature controlled forced air cooling


Inverter Circuit AC contactor AC breaker Altitude at full load (2) 3000m

DC1
-

Display Touch screen


DC AC
AC
EMI DC/AC EMI
Filter Communication port RS485/Ethernet
Filter Filter

Certificates and approvals (more available on request) IEC 62109, IEC 61727, IEC 61683, IEC 62116, IEC 60068, IEC 61000
- +
DC12

A Dimensions (W×H×D) 2991×2890×2438mm


DC SPD B
DC breaker AC SPD C Weight 6500kg
Inverter Circuit AC contactor AC breaker

DC1
-

DC AC (1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
AC
EMI DC/AC
Filter
EMI (2) When above 3000m, the inverter begins derating, contact us for derating parameters
Filter Filter
- +
DC12

DC SPD
AC SPD

Copyright 2018 SINENG. All rights reserved.


11 Specifications subject to change without notice. 12
EP-2500-HA-OD/35
Central inverter integrated with MV transformer

Input (DC)
Max. PV input voltage 1500V

Max. input current 3508A

MPP voltage range for nominal power 800~1300V


More power generation
Inverter Max. efficiency 99%, Euro efficiency 98.7% Number of MPPT trackers 2
Full power operation without derating at 50℃ Number of DC inputs 20~24
1500Vdc PV system reduce power loss Output (AC)
Rated output power 2500kW
Max. output power 2750kW
Rated grid voltage 35kV
Low system cost Max. inverter output current 45.4A
IP54 container solution Integrated with MV transformer
Rated grid frequency / range 50 Hz/45~55 Hz, 60Hz/55~65 Hz
Auxiliary power supply and communication integrated
Output current harmonic(at nominal power) <3%
Integrated reactive power compensation
High DC/AC ratio up to 1.5 Power factor at nominal power / range >0.99/0.8 lagging to 0.8 leading

Protection
DC input protection Circuit breaker

AC MV output protection MV breaker


High reliability
Overvoltage protection DC Type II/AC Type II
Key components online monitoring
Leakege current monitoring Yes
Redundancy design for cooling fans and
control power supply Ground fault monitoring Yes
Industry oriented design for harsh enviroment Insulation monitoring Yes

Overheat protection Yes

Reactive power compensation Optional

Anti-PID function Optional

Smoke detecting Yes


Grid friendly
LVRT and HVRT function Efficiency
Low harmonics and fast response for grid regulation Inverter Max. efficiency 99%

Inverter EU efficiency 98.70%

General date
Dimensions (W×H×D) 6058×2890×2438mm

Weight 14t

Protection level IP54


Sineng Electric (India) Pvt Ltd.
Circuit temperature (1) -30℃~+60℃
Transfomer Oil-immerse transformer
DC breaker
Cooling mode Temperature controlled forced air cooling
Inverter Circuit AC contactor AC breaker
Altitude at full load(2)

DC1

3000m
-

DC AC
EMI DC/AC
AC
EMI
Display LCD
Filter
Filter Filter
Communication port RS485/Ethernet
Transformer MW breaker
- +
DC12

A
DC SPD B
DC breaker AC SPD C
(1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
(2) When above 3000m, the inverter begins derating, contact us for derating parameters
Inverter Circuit AC contactor AC breaker

DC1
-

DC AC
AC
EMI DC/AC EMI
Filter
Filter Filter
- +
DC12

DC SPD
AC SPD

Copyright 2018 SINENG. All rights reserved.


13 Specifications subject to change without notice. 14
EP-1250-HA
EP Series 1500V Central Solar Inverter

Input (DC)
Max. PV input voltage 1500V

Max. input current 1754A


More power generation MPP voltage range for nominal power 800V~1300V
Max. efficiency 99%, Euro efficiency 98.7%.
Number of MPPT trackers 1
1.1 Pn overload capacity at 45℃
Full power operation without derating at 50℃ Number of DC inputs 10~12

Output (AC)
Rated output power 1250kW

Max. output power 1375kW

Rated grid voltage 550V


Low system cost
Integrated DC power distribution function Grid voltage range 468V~605V
Integrated reactive power compensation 1443A
Max. output current
High DC/AC ratio up to 1.5
Rated grid frequency / range 50 Hz/45~55Hz, 60Hz/55~65Hz

Output current harmonic(at nominal power) < 3%

Power factor at nominal power / range >0.99/0.8 lagging to 0.8 leading

Protection
High reliability
Key components on line monitoring DC input protection Circuit breaker
Redundancy design for cooling fans and AC output protection Circuit breaker
power supply
Industry oriented design for harsh enviroment Overvoltage protection DC Type II/AC Type II

Leakege current monitoring Yes

Ground fault monitoring Yes

Insulation monitoring Yes

Overheat protection Yes


Grid friendly
LVRT and HVRT function Reactive power compensation Optional
Low harmonics and fast response for grid regulation Anti-PID function Optional
Efficiency
Max. efficiency 99%

EU efficiency 98.70%

General date
Self-consuming at runtime <1220W

Circuit Self-consuming in standby <40W

Protection level IP20


(1) ﹣30℃~+60℃
Temperature
DC breaker
Allowed humidity(non condensing) 0~95%
Inverter Circuit AC contactor AC breaker
Cooling mode Temperature controlled forced air cooling

DC1

Altitude at full load (2) 3000m


-

A
DC AC
AC Display Touch screen
EMI DC/AC EMI B
Filter
Filter Filter
C Communication port RS485/Ethernet

Certificates and approvals (more available on request) IEC 62109, IEC 61727, IEC 61683, IEC 62116, IEC 60068, IEC61000
- +
DC12

Dimensions (W×H×D) 1603×2050×725mm


DC SPD
Weight 1150kg
DC breaker AC SPD

(1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
(2) When above 3000m, the inverter begins derating, contact us for derating parameters

Copyright 2018 SINENG. All rights reserved.


15 Specifications subject to change without notice. 16
EP-1000-HA
EP Series 1500V Central Solar Inverter

Input (DC)
Max. PV input voltage 1500V

Max. input current 1403A


More power generation MPP voltage range for nominal power 800~1300V
Max. efficiency 99%, Euro efficiency 98.7% 1
Number of MPPT trackers
1.1 Pn overload capacity at 45℃
Full power operation without derating at 50℃ Number of DC inputs 8~10

Output (AC)
Rated output power 1000kW

Max. output power 1100kW

Rated grid voltage 550V


Low system cost
Integrated DC power distribution function Grid voltage range 468~605V
Integrated reactive power compensation Max. output current 1155A
High DC/AC ratio up to 1.5
Rated grid frequency / range 50 Hz/45~55 Hz, 60Hz/55~65Hz

Output current harmonic(at nominal power) <3%

Power factor at nominal power / range >0.99/0.8 lagging to 0.8 leading

High reliability Protection


Key components online monitoring DC input protection Circuit breaker
Redundancy design for cooling fans and AC output protection Circuit breaker
control power supply
Industry oriented design for harsh enviroment Overvoltage protection DC Type II/AC Type II

Leakege current monitoring Yes

Ground fault monitoring Yes

Insulation monitoring Yes

Overheat protection Yes


Grid friendly
Reactive power compensation Optional
LVRT and HVRT function
Low harmonics and fast response for grid regulation Anti-PID function Optional
Efficiency
Max. efficiency 99%

EU efficiency 98.70%

General date
Self-consuming at runtime <1220W

Circuit Self-consuming in standby <40W

Protection level IP20


(1) ﹣30℃~+60℃
Temperature

DC breaker Allowed humidity(non condensing) 0~95%

Inverter Circuit AC contactor AC breaker Cooling mode Temperature controlled forced air cooling

DC1

(2) 3000m
Altitude at full load
-

A
DC AC Touch screen
AC Display
EMI DC/AC EMI B
Filter
Filter Filter Communication port
C RS485/Ethernet
Certificates and approvals (more available on request) IEC 62109, IEC 61727, IEC 61683, IEC 62116, IEC 60068,IEC 61000
- +
DC10

Dimensions (W×H×D) 1603×2050×725mm


DC SPD
Weight 1020kg
DC breaker AC SPD

(1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
(2) When above 3000m, the inverter begins derating, contact us for derating parameters

Copyright 2018 SINENG. All rights reserved.


17 Specifications subject to change without notice. 18
EP-2500-AI-OD
EP Series 1000V Central Solar Inverter

Input (DC)
Max. PV input voltage 1000V

Max. input current 4844A

More power generation MPP voltage range for nominal power 600~850V
Max. efficiency 99%, Euro efficiency 98.7% Number of MPPT trackers 2
1.15 Pn overload capacity at 45℃
Number of DC inputs 16~24
Full power operation without derating at 50℃
Output (AC)
Rated output power 2500kW

Max. output power 2874kW

Rated grid voltage 415V


Low system cost
IP54 container solution without house Grid voltage range 340~480V
Auxiliary power supply and communication integrated 4000A
Max. output current
Integrated reactive power compensation
High DC/AC ratio up to 1.5 Rated grid frequency / range 50 Hz/45~55 Hz, 60Hz/55~65Hz

Output current harmonic(at nominal power) <3%

Power factor at nominal power / range >0.99/0.8 lagging to 0.8 leading

Protection
High reliability
DC input protection Circuit breaker
Key components online monitoring
Redundancy design for cooling fans and AC output protection Circuit breaker
control power supply
Overvoltage protection DC Type II/AC Type II
Industry oriented design for harsh enviroment
Leakege current monitoring Yes

Ground fault monitoring Yes

Insulation monitoring Yes

Overheat protection Yes


Grid friendly
Reactive power compensation Optional
LVRT and HVRT function
Low harmonics and fast response for grid regulation Anti-PID function Optional

Smoke detecting Yes

Efficiency
Max. efficiency 99%

EU efficiency 98.70%

General data
Self-consuming at runtime <3560W
Circuit
Self-consuming in standby <80W

DC breaker Protection level IP54


Inverter Circuit AC contactor AC breaker (1)
Temperature -30℃~+60℃

DC1
-

DC AC
AC Cooling mode Temperature controlled forced air cooling
EMI DC/AC EMI
Filter
Filter
Filter
Altitude at full load (2) 3000m

Display Touch screen


- +
DC12

A
DC SPD B
AC SPD
Communication port RS485/Ethernet
DC breaker C
Inverter Circuit AC contactor AC breaker Certificates and approvals (more available on request) IEC 62109, IEC 61727, IEC 61683, IEC 62116, IEC 60068, IEC 61000

DC1
-

DC AC Dimensions (W×H×D) 2991×2890×2438mm


AC
EMI DC/AC EMI
Filter
Filter Filter Weight 5050kg
- +
DC12

DC SPD
AC SPD
(1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
(2) When above 3000m, the inverter begins derating, contact us for derating parameters

Copyright 2018 SINENG. All rights reserved.


19 Specifications subject to change without notice. 20
EP-2500-AI-OD/35
Central inverter integrated with MV transformer

Input (DC)
Max. PV input voltage 1000V

Max. input current 4844

MPP voltage range for nominal power 600-850V


More power generation
Inverter Max. efficiency 99%,Euro efficiency 98.7% Number of MPPT trackers 2
1.1Pn overload capacity at 45℃ Number of DC inputs 16~24
Full power operation without derating at 50℃ Output (AC)
Rated output power 2500kW
Max. output power 2750kW
Rated grid voltage 35kV
Low system cost Max. inverter output current 45.4A
IP54 container solution Integrated with MV transformer
Rated grid frequency / range 50 Hz/45~55Hz, 60Hz/55~65 Hz
Auxiliary power supply and communication integrated
Output current harmonic(at nominal power) <3%
Integrated reactive power compensation
High DC/AC ratio up to 1.5 Power factor at nominal power / range >0.99/0.8 lagging to 0.8 leading

Protection
DC input protection Circuit breaker

AC MV output protection MV breaker


High reliability
Overvoltage protection DC Type II/AC Type II
Key components online monitoring
Leakege current monitoring Yes
Redundancy design for cooling fans and
control power supply Ground fault monitoring Yes
Industry oriented design for harsh enviroment Insulation monitoring Yes

Overheat protection Yes

Reactive power compensation Optional

Anti-PID function Optional

Smoke detecting Yes


Grid friendly
LVRT and HVRT function Efficiency
Low harmonics and fast response for grid regulation Inverter Max. efficiency 99%

Inverter EU efficiency 98.70%

General data
Dimensions (W×H×D) 6058×2890×2438mm

Weight 14t

Protection level IP54


Sineng Electric (India) Pvt Ltd.
Circuit temperature
(1) -30℃~+60℃

Transfomer Oil-immerse transformer


DC breaker
Cooling mode Temperature controlled forced air cooling
Inverter Circuit AC contactor AC breaker

DC1

Altitude at full load (2) 3000m


-

DC AC
AC LCD
EMI DC/AC EMI Display
Filter
Filter Filter
Transformer MW breaker
Communication port RS485/Ethernet
- +
DC12

A
DC SPD B
AC SPD C
(1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
DC breaker
(2) When above 3000m, the inverter begins derating, contact us for derating parameters
Inverter Circuit AC contactor AC breaker

DC1
-

DC AC
AC
EMI DC/AC EMI
Filter
Filter Filter
- +
DC12

DC SPD
AC SPD

Copyright 2018 SINENG. All rights reserved.


21 Specifications subject to change without notice. 22
EP-1250-AI
EP Series 1000V Central Solar Inverter

Input (DC)
Max. PV input voltage 1000V

Max. input current 2422A


More power generation MPP voltage range for nominal power 600~850V
Max. efficiency 99%, Euro efficiency 98.7% Number of MPPT trackers 1
1.15 Pn overload capacity at 45℃
Full power operation without derating at 50℃ Number of DC inputs 8~12

Output (AC)
Rated output power 1250kW

Max. output power 1437kW

Rated grid voltage 415V


Low system cost
Integrated DC power distribution function Grid voltage range 340~480V
Integrated reactive power compensation Max. output current 2000A
High DC/AC ratio up to 1.5
Rated grid frequency / range 50 Hz/45~55Hz, 60Hz/55~65Hz

Output current harmonic(at nominal power) < 3%

Power factor at nominal power / range >0.99/0.8 lagging to 0.8 leading

Protection
High reliability
Key components online monitoring DC input protection Circuit breaker
Redundancy design for cooling fans and control AC output protection Circuit breaker
power supply
Industry oriented design for harsh enviroment Overvoltage protection DC Type II/AC Type II

Leakege current monitoring Yes

Ground fault monitoring Yes

Insulation monitoring Yes

Overheat protection Yes


Grid friendly
LVRT and HVRT function Reactive power compensation Optional
Low harmonics and fast response for grid regulation Anti-PID function Optional
Efficiency
Max. efficiency 99%

EU efficiency 98.70%

General date
Self-consuming at runtime <1780W

Circuit Self-consuming in standby <40W

Protection level IP20


(1)
Temperature ﹣30℃~+60℃
DC breaker 0 - 95%
Allowed humidity(non condensing)
Inverter Circuit AC contactor AC breaker Temperature controlled forced air cooling

Cooling mode
DC1

(2)
Altitude at full load 3000m
-

A
DC AC
AC Display Touch screen
EMI DC/AC EMI B
Filter
Filter Filter RS485/Ethernet
C Communication port

Certificates and approvals (more available on request) IEC 62109, IEC 61727, IEC 61683, IEC 62116, IEC 60068,IEC 61000
- +
DC12

Dimensions (W×H×D) 2400×2000×750mm


DC SPD Weight 1570kg
DC breaker AC SPD

(1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
(2) When above 3000m, the inverter begins derating, contact us for derating parameters

Copyright 2018 SINENG. All rights reserved.


23 Specifications subject to change without notice. 24
Central Distributed Inverter Series

1000V Central Distributed Inverter 1000V Intelligent MPPT Combiner Box

CP-1000-B CP-1000-B-OD

EJB-16-M4 EJB-24-M4

CP-2000-B-OD CP-2000-B-OD/35

Feature

Distributed MPPT Optimizers,Centralized DC/AC solution Industrial oriented design for harsh environment Grid friendly and support (L/HVRT, Active and reactive power control)
Multiple-MPPTs function reduces mismatch loss Anti-PID solution effectively prevent PV module effect Good quality components, high reliability

Copyright 2018 SINENG. All rights reserved.


25 Specifications subject to change without notice. 26
Central Distributed Solution Focus On Lower LCOE String-level MPPT to improve power yield

String-level MPPT solution


DC combiner box with MPPT function,effectively reduce power loss of mismatch problem and improve yield

Intelligent MPPT combiner box with built-in DC-DC converter


Boost circuits improve DC voltage up to stable 800Vdc, higher efficiency and lower DC power loss

Higher AC output voltage


AC output voltage up to 520Vac, lower current compared with the same capacity inverter,effectively improve
efficiency

Working mode
In actual PV power generation system, such problems as dust covering, shade blocking, direct current line loss inconformity, module degradation, dip angle discrepancy
and other module mismatch are inevitable. I-V curved line of every module is difficult to keep the same. the traditional centralized power generation solution can't make
each string effectively work on its maximum power point, while the string MPPT centralized and distributed power generating solution can maximize the function of
everyone independent MPPT module.

Module A Dust

The power generation PV inverter combined with DC converter to Module B Shadow


increases 2%~ 5% realize energy shifting
Module C Normal
Lower system cost Perfect combination with tracking support DC combiner box Central Inverter

Better performance of the grid connection


Optimal matching with bifacial PV module
and output power quality
String A
Intelligent and central monitoring
management Traditional single MPPT central power
generating solution String B

String C
Sineng integrated the respective advantages of string inverter and central inverter, proposed the CP central distributed PV power generation
solution, which can increase the power generation efficiency and reduce the system cost.

Compared to the traditional central grid power station, DC combiner is replaced by the intelligent MPPT combiner. Each 1MW power generating Module A Dust
system has 48 independent MPPT units, which can effectively solve power generation losses because of dust covering, shade blocking, direct
current line loss inconformity, module degradation, dip angle discrepancy and other module mismatch and increase at least 2% power generation. Module B Shadow
Each power unit is improved from the traditional centralized 1 MW capacity to the centralized-distributed 2 MW capacity, with make simper network-
ing scheme and lower system cost. Module C Normal
Central Distributed
MPPT controller Inverter
Because the voltage from the intelligent MPPT combiner to the inverter is promoted above DC 800 V, the AC voltage from inverter to the transformer
is promoted to AC 520V, corresponding cost of AC/DC cable can be reduced over 30%; Each 2 MW square uses 2 MVA double split winding
transformer, to replace the two groups of 1 MVA double split winding transformer, and cost reduces about 30%; For smaller inverter room, the cost
is reduced by about 50%.
String A

The summarized energy by 48 optimization unit is concentrated transported to the grid through 1 MW inverter , which inherit the advantages of
String level MPPT central distributed power
centralized inverter such as high reliability, easy maintenance and management, and ensure the output power quality and grid-connected perfor- generation solution String B
mance are optimized.

String C

Copyright 2018 SINENG. All rights reserved.


27 Specifications subject to change without notice. 28
String-level P-V curve scanning,monitoring and diagnosis Intelligent management and grid friedly

Smart APP Message E-MAIL PC


String-level power
curve scanning to
find any abnormal
strings

Automatic I-V Intelligent O&M platform Internet


curve scanning
to identify
abnormal strings

Core switch
Automatic P-V curve
scanning records the
normal PV
characteristic curve

SAU-100

Built-in DSP28335
floating point processor RS485 RS485 RS485 RS485 RS485

Environment monitor Intelligent MPPT combiner box CP-1000-B Transformer

String-level protection makes String-level monitor Comprehensive monitoring and management for PV module, combiner box, inverter and transformer
sure system reliability and diagnosis
Full O&M experience including healthy condition diagnosis, trouble-shooting guidance, service management, asset management
Enhanced measures of safety protection. Power curve scanning helps to find any abnormal strings immediately. Convenient system configuration, friendly and easy SCADA interface
Standard DC breaker with active trip function Built-in high precision PV curve scanning function, perfor-
Support smart APP, PC and Tablets, convenient monitoring and maintaining whenever and wherever possible
for protection. mance comparable to professional instrument.
Electrical isolation between input and output, completely eliminate String characteristics curves are displayed on SCADA.
fatal failure.

Intelligence centralized monitoring

Intelligent Energy Cloud Platform


Module fault Fault diagnosis Comprehensive monitoring,diagnosis and control
String current abnormal Intelligent O&M platform based on expert
experience, Real-time warning,fault, and O&M
String-level monitoring for precise string fault location
Module cleaning
advices Optional wireless/ wired monitoring
Module derating analysis
Support remote monitoring and control

Data transmission
SAU-100
The data is collected, analyzed, uploaded by Friendly grid
smart logger developed by Sineng

Advantages of good quality grid with lower output harmonics and higher power factor

P-V curve scanning Centralized grid connection with distributed string-level MPP is more stale without harmonics resonance and current circulation
String P-V curves are collected by regular intervals Easy communication system, higher reliability and quick response
or backstage monitoring system
Intelligent MPPT combiner box Built-in high precision floating CPU Good grid adaptability with L/HVRT and reactive power support

Copyright 2018 SINENG. All rights reserved.


29 Specifications subject to change without notice. 30
DC storage solution, convenient for energy shifting and smooth output Perfect combination of central distributed inverter and solar tracking

The application of energy storage technology in PV power station can not only solve the problem of light abandoning, promote renewable energy Integrated power supply Optimized communication solution
dissipation, but also realize the smooth power fluctuation, peak shaving , frequency modulation and voltage regulation for renewable energy. It is an
MPPT combiner box provide DC power Tracking system shares the common communication cable to save cost. The SAU-100 can
important means to meet the large-scale access of renewable energy to the power grid. It is also a distributed energy system and intelligent electricity,
supply,saving cable. collect the wind information, radiation information,
and plays an important role in the energy Internet.
High safety protection with specialized GPS time information, power grid state and so on, and use the communication link of the
SPD protection. intelligent MPPT combiner box to notify each tracking support controller. When the wind
Specialized power module for tracking speed is abnormal, or the power supply network is abnormal, the system can get informa-
system to improve reliability. tion in time and lay
module flat for protection.

MPPT Combiner box Central distributed inverter Transformer Grid


PV module
Bidirectional DC/DC converter

Central Distributed Inverter

PV module Intelligent MPPT


Storage battery
Combiner Box

Grid

Power output power of inverter output power of PV

800VDC Redundant
power supply
output power of PV RS485 SAU-100

Time
Smooth output of PV plant Pn: rated power Higher DC/AC ratio abilility

Control box for tracking


Sineng Communication
power and
module control module

Battery Time(S)
AC output power
Improve the accuracy of prediction PV power Higher friendly grid

The DC energy storage scheme does not involve the related reporting and approval process of new grid connected equipment.
The storage energy access procedures are simple, the utilization of equipment is high, and the investment and land occupation of
the equipment are significantly reduced.
PV plant can be built in advance, and energy storage system will be increased at later stage to achieve smooth output.
Distributed energy storage solution adopts dispersed energy storage to avoid or reduce battery pack parallel connection and
prolong battery life.
The bidirectional converter is connected to the DC bus of the central distributed inverter. The DC bus voltage is stable, which
avoids the overvoltage shock from the power grid and reduces the failure rate of the bidirectional converter.

Copyright 2018 SINENG. All rights reserved.


31 Specifications subject to change without notice. 32
2MW/4MW typical block size system solution

Centralized
Control Center Sienergy AC power cable
Monitoring
Intelligent Energy Grid Dispatch Center
cloud
Cloud Platform
DC power cable
PC
Communication cable

Router
APP

Firewall

Recommended Application Scenarios

Core switch
Large ground PV plant
10~35kV
Agricultural PV complementary power plant
Water area PV plant
……

Fiber Switch 4MVA Fiber Switch


Transformer Transformer 2MVA

Large block size, lower initial


investment, convenient O&M

SAU-100 SAU-100

Centralized connection to grid,good


adaptability to grid without the risk
of resonance

Inverter CP-2000-B-OD CP-2000-B-OD CP-1000-B CP-1000-B

Built-in SVG function save the cost


of SVG device

DC Combiner Reserved interface for


DC storage energy

Smart management platform with


intelligent analysis and protection,
PV module
fault alarm, O&M information ect

block 1# block N#

Copyright 2018 SINENG. All rights reserved.


33 Specifications subject to change without notice. 34
CP-2000-B-OD
CP Series Central Distributed Solar Inverter

Input (DC)
Max. PV input voltage 1000V

Max. input current 2878A


More power generation MPP voltage range for nominal power 300~820V
Multiple MPPTs decreasing mismatch loss Max number of MPPT trackers 96
High DC input and AC output voltage decreasing cable line loss
Max number of DC inputs 24
High system efficiency with maximum inverter efficiency 99.1%
Output (AC)
Rated output power 2000kW

Max. output power 2200kW

Rated grid voltage 520V

Low system cost Grid voltage range 442~572V


IP54 container solution without house Max. output current 2442A
Auxiliary power supply and communication integrated 50 Hz/45~55Hz, 60Hz/55~65Hz
Rated grid frequency / range
High DC/AC ratio up to 1.5
Output current harmonic(at nominal power) <3%

Power factor at nominal power / range >0.99/0.8 lagging to 0.8 leading

Protection
DC input protection Circuit breaker

High reliability AC output protection Circuit breaker


Key components online monitoring Overvoltage protection DC Type II/AC Type II
Redundancy design for cooling fans and control power Leakege current monitoring Yes
supply Industry oriented design for harsh enviroment
Ground fault monitoring Yes

Insulation monitoring Yes

Overheat protection Yes

Reactive power compensation Optional

Anti-PID function Optional


Grid friendly
Smoke detecting Yes
LVRT and HVRT function
Low harmonics and fast response for grid regulation Efficiency
Max. efficiency 99.10%

EU efficiency 98.65%

General Data
Self-consuming at runtime <3000W

Self-consuming in standby <40W

Circuit Protection level IP54

temperature (1) -30℃~+60℃

DC breaker
Cooling mode Temperature controlled forced air cooling
-+
PV1

MPPT
Inverter Circuit AC contactor AC breaker Altitude at full load (2) 3000m
Combiner Box
PV16
-+

DC AC Display LCD
AC
EMI DC/AC EMI
Filter
Filter Filter Communication port RS485/Ethernet
PV192 PV177
- + -+

Certificates and approvals (more available on request) IEC 62109, IEC 61727, IEC 61683, IEC 62116, IEC 60068, IEC 61000
MPPT
A
Combiner Box
DC SPD B Dimensions (W×H×D) 2400×2590×2600mm
AC SPD C
DC breaker Weight 5000kg
-+
PV1

Inverter Circuit AC contactor AC breaker


MPPT
Combiner Box (1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
PV16
-+

DC AC
AC (2) When above 3000m, the inverter begins derating, contact us for derating parameters
EMI DC/AC EMI
Filter
Filter Filter
PV192 PV177
- + -+

MPPT
Combiner Box
DC SPD
AC SPD
Sineng Electric Co., Ltd.

Copyright 2018 SINENG. All rights reserved.


35 Specifications subject to change without notice. 36
CP-2000-B-OD/35
Central distributed inverter integrated with MV transformer
Input (DC)
Max. PV input voltage 1000V

Max. input current 2878A

More power generation MPP voltage range for nominal power 300~820V

Multiple MPPTs decreasing mismatch loss Max number of MPPT trackers 96


High DC input and AC output voltage decreasing cable line loss Max number of DC inputs 24
High system efficiency with maximum inverter efficiency 99.1%
Output (AC)
Rated output power 2000kW
Max. output power 2200kW
Rated grid voltage 35kV

Low system cost Max. inverter output current 36.2A


IP54 container solution Integrated with MV transformer Rated grid frequency / range 50 Hz/45~55Hz, 60Hz/55~65Hz
Auxiliary power supply and communication integrated Output current harmonic(at nominal power) <3%
High DC/AC ratio up to 1.5
Power factor at nominal power / range >0.99/0.8 lagging to 0.8 leading

Protection
DC input protection Circuit breaker

AC MV output protection MV breaker


High reliability Overvoltage protection DC Type II/AC Type II
String-level monitoring and diagnosis Leakege current monitoring Yes
Redundancy design for cooling fans and control power
Ground fault monitoring Yes
supply Industry oriented design for harsh enviroment
Insulation monitoring Yes

Overheat protection Yes

Reactive power compensation Optional

Anti-PID function Optional

Smoke detecting Yes


Grid friendly
LVRT and HVRT function Efficiency
Low harmonics and fast response for grid regulation Inverter Max. efficiency 99.10%

Inverter EU efficiency 98.65%

General data
Dimensions (W×H×D) 4708×2591×2438mm

Weight 14t

Protection level IP54


Circuit temperature (1)
Sineng Electric (India) Pvt Ltd.
-30℃~+60℃

Transfomer Oil-immerse transformer


DC breaker Temperature controlled forced air cooling
Cooling mode
-+
PV1

Inverter Circuit AC contactor AC breaker


Altitude at full load (2)
MPPT
Combiner Box 3000m
PV16
-+

DC AC
EMI DC/AC
AC
EMI Display LCD
Filter
Filter Filter

Transformer
Communication port RS485/Ethernet
PV192 PV177

MW breaker
- + -+

MPPT
A
Combiner Box
DC SPD B (1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
AC SPD
DC breaker C (2) When above 3000m, the inverter begins derating, contact us for derating parameters
-+
PV1

Inverter Circuit AC contactor AC breaker


MPPT
Combiner Box
PV16
-+

DC AC
AC
EMI DC/AC EMI
Filter
Filter Filter
PV192 PV177
- + -+

MPPT
Combiner Box
DC SPD
AC SPD

Copyright 2018 SINENG. All rights reserved.


37 Specifications subject to change without notice. 38
CP-1000-B
CP Series Central Distributed Solar Inverter Input (DC)
Max. PV input voltage 1000V

Max. input current 1439A

MPP voltage range for nominal power 300~870V

Max number of DC inputs 48

Max number of MPPT trackers 12

Output (AC)
Rated output power 1000kW

Max. output power 1100kW

Rated grid voltage 520V

More power generation Grid voltage range 442~572V


High DC input and AC output voltage decreasing cable line loss Max. output current 1221A
Multiple MPPTs decreasing mismatch losxs
Rated grid frequency / range 50Hz/45~55Hz, 60Hz/55~65Hz

High reliability Output current harmonic(at nominal power) < 3%


Key components online monitoring Power factor at nominal power / range >0.99/0.8 lagging to 0.8 leading
Redundancy design for cooling fans and control power supply
Protection
Industry oriented design for harsh enviroment
DC input protection Circuit breaker
Low system cost AC output protection Circuit breaker
Integrated DC power distribution function
Overvoltage protection DC Type II/AC Type II
Integrated reactive power compensation
High DC/AC ratio up to 1.5 Leakege current monitoring Yes

Ground fault monitoring Yes


Grid friendly Insulation monitoring Yes
LVRT and HVRT function
Overheat protection Yes
Low harmonics and fast response for grid regulation
Reactive power compensation Optional

Anti-PID function Optional

Efficiency
Max. efficiency 99.10%

EU efficiency 98.65%

General Data
Self-consuming at runtime <1000W

Self-consuming in standby <20W

Circuit Protection level IP20 (IP21 Optional)


(1)
Temperature ﹣30℃~+60℃

Allowed humidity(non condensing) 0~95 %

DC breaker Cooling mode Temperature controlled forced air cooling


(2)
-+
PV1

Inverter Circuit AC contactor AC breaker Altitude at full load 3000m


MPPT
Combiner Box Display LCD
PV16
-+

A
DC AC
AC Communication port RS485/Ethernet
EMI DC/AC EMI B
Filter
Filter Filter
C Certificates and approvals IEC 62109, IEC 61727, IEC 61683,
(more available on request) IEC 62116, IEC 60068, IEC61000
PV192 PV177
- + -+

MPPT Dimensions (W×H×D) 1205×2050×750mm


Combiner Box
DC SPD Weight 1100kg
DC breaker AC SPD

(1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
(2) When above 3000m, the inverter begins derating, contact us for derating parameters

Copyright 2018 SINENG. All rights reserved.


39 Specifications subject to change without notice. 40
EJB-16-M4/EJB-24-M4
Intelligent MPPT optimizer

Model EJB-16-M4 EJB-24-M4


Input (DC)
Max. PV input voltage 1000V 1000V

MPP voltage range for nominal power 300~820V 300~820V

Number of DC inputs 16 24

Maximum input power of each MPPT unit 27.5kW 44kW


More power generation
Rated input power of each MPPT unit 25kW 40kW
Equipped with 4 MPPT units
Higher DC voltage for lower power loss Number of MPPT 4 4

Number of strings per MPPT unit 4 6


High reliability Output (AC)
P-V curve scanning, monitoring the module status
Rated output voltage 820V 820V
Natural air cooling without fans for long life
Output voltage range 750~850V 750~850V

Easy O&M Max. output current 130A 188A


IP65 for outdoor use Protection
String monitoring, easy for checking abnormal strings
Input protection switch Yes Yes

Input over-current protection Yes Yes

Reverse polarity protection Yes Yes

String fault detection Yes Yes

String flowing backwards protection Yes Yes

DC surging protection Yes Yes

Output protection switch Yes Yes

Output over-current protection Yes Yes

General data
Max. efficiency 99.50% 99.50%

Degree of protection IP65 IP65

Temperature (1) ﹣30℃~+60℃ ﹣30℃~+60℃

Allowed humidity(non condensing) 0~100% 0~100%

System Application Cooling mode Natural air cooling Natural air cooling

Altitude at full load (2) 3000m 3000m

Communication port RS485 RS485


300~820V 820V
Dimensions (W×H×D) 900×800×270mm 1100×800×270mm

Weight 65kg 70kg

300~820V 820V 520V 10~35kV

CP-1000-B Transforemer Grid


300~820V 820V

PV Panel EJB-16-M4

Copyright 2018 SINENG. All rights reserved.


41 Specifications subject to change without notice. 42
String Inverter Series Intelligent communication solution of string inverter

Power
Plant type Recommended solution System diagram String inverter distribution cabinet Grid
Smart
Single phone
inverter
wireless
Transformer communi- Operating
cation terminal
data logger
solution

AC AC
Large commercial and industrial roof String inverter
combiner box combiner box Datalog
GPRS/WIFI
AC
Multiple cable
Smart
SP-45K SP-45K SP-45K inverters phone
wireless
communi-
Power distribution cabinet Grid
Capacity is normally larger than cation Operating
solution terminal
300kW,complex rooftop structure,many PV-panel PV-panel DC
small units,different direction,10kV high
voltage grid cable

String inverter
Com-
Control
Local
Residential distributed cabinet SAU-100 central
monitoring muni-
cation
Intelligent
Medium commercial and industrial roof O&M cable
RS485
communi- Power
SP-40K AC AC cation dispatch
combiner box combiner box solution

P
AC combiner box transformer Grid L
Small PV plant C
SP-40K SP-60K-L
String inverter
Control
SAU-100 central Local
monitoring
PV-panel PV-panel
Capacity is normally several hundreds Intelligent
kW, simple grid structure, SP-60K-L
O&M
convenient O&M, AC voltage 380V PLC
communi- Power
cation dispatch
solution

AC combiner box transformer Grid

Grid Grid Grid


Communication configuration
Residential roof 型号
RS485 PLC GPRS WIFI
Meter Meter Meter

SP-3000/5000 standard Optional Optional


SP-3000
SP-5000
SP-20K
SP-40K standard Optional
SP-60K-L

Capacity is normally 3~20kW,individual SP-45K standard Optional


PV-panel PV-panel PV-panel
residential rooftop with 220/380V AC
voltage

Copyright 2018 SINENG. All rights reserved.


43 Specifications subject to change without notice. 44
SP-60K-L
SP Series String Solar Inverter

Input (DC)
Max. PV input voltage 1000V

Max. input current 132A

Rated input voltage 600V


More power generation
MPP voltage range 250~900V
Max. efficiency 99%, Euro efficiency 98.60%
3 MPPTs for tracking maximum PV power MPP voltage range for nominal power 580~800V

Number of MPPT trackers 3

Max. number of PV strings per MPPT 4

Output (AC)
Rated output power 60kW

Low system cost Max. output power 66kW


Up to 12 PV strings
Rated grid voltage 400V
High DC/AC ratio for lower LCOE
Grid voltage range 340~440V

Max. output current 95A

Rated grid frequency / range 50Hz/45~55Hz, 60Hz/55~65Hz

Output current harmonic(at nominal power) <3%


High reliability
Power factor at nominal power / range >0.99/0.8leading to 0.8lagging
Cooling fan with IP68 protection level
String monitoring function, easy for quick trouble Protection
shooting
DC reverse connection protection Circuit breaker

Overvoltage protection DC Type II/AC Type II

Leakege current protection Yes

Grid monitoring Yes

Insulation monitoring Yes


Grid friendly
Anti-island protection Yes
Active power derating and reactive power adjustable
Low harmonics and fast response for grid regulation Efficiency
Max. efficiency 99.00%

EU efficiency 98.60%

General Data
Self-consuming in standby <1W

Protection level IP65


Circuit
Noise <60dB
(1)
Temperature ﹣30℃~+60℃
DC Fuse DC Switch DC Bus
MPPT1 Cooling mode Temperature controlled forced air cooling
PV1
-+

DC Altitude at full load (2) 3000m


EMI DC/DC
PV4
-+

Filter
Inverter Circuit AC relay Communication port Standard:RS485, Optional:GPRS
DC SPD Dimensions (W×H×D) 635×897×257mm
MPPT2 A
AC
-+
PV5

AC Weight 78kg
DC DC/AC EMI B
Filter
EMI DC/DC Filter
C
PV8
-+

Filter
(1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
(2) When above 3000m, the inverter begins derating, contact us for derating parameters
DC SPD MPPT3
PV9

DC
-

EMI DC/DC
AC SPD
PV12
-+

Filter

DC SPD

Copyright 2018 SINENG. All rights reserved.


45 Specifications subject to change without notice. 46
SP-45K
SP Series String Solar Inverter

Input (DC)
Max. PV input voltage 1100V

Max. input current 88A

Rated input voltage 760V


More power generation
MPP voltage range 200~1000V
Max. efficiency 99%, Euro efficiency 98.6%
4 MPPTs for tracking maximum PV power MPP voltage range for nominal power 510~850V

Number of MPPT trackers 4

Max. number of PV strings per MPPT 2

Output (AC)
Rated output power 45kW

Low system cost Max. output power 52.5kW


Power line communication save cable cost and civil work
Rated grid voltage 500V
High DC/AC ratio for lower LCOE
Grid voltage range 425~550V

Max. output current 60.8A

Rated grid frequency / range 50 Hz/45~55Hz, 60Hz/55~65Hz

Output current harmonic(at nominal power) <3%


High reliability
Power factor at nominal power / range >0.99/0.8 lagging to 0.8 leading
Natual cooling without fan for harsh environment
and long life Protection
String monitoring function, easy for quick trouble
DC reverse connection protection Yes
shooting
Overvoltage protection DC Type II/AC Type II

Leakege current protection Yes

Grid monitoring Yes

Insulation monitoring Yes


Grid friendly
Anti-island protection Yes
LVRT and HVRT function
Low harmonics and fast response for grid regulation Anti-PID function Yes

Efficiency
Max. efficiency 99.00%

EU efficiency 98.60%

General Data
Self-consuming in standby <3W
Circuit
Protection level IP65

Noise <35dB
DC Switch DC Bus
MPPT1 (1)
Temperature ﹣30℃~+60℃
PV1
-+

DC
EMI DC/DC
Cooling mode Natural cooling
PV2
-+

Filter

DC SPD Inverter Circuit AC relay Altitude at full load (2) 3000m


MPPT2
-+
PV3

DC Communication port Standard: RS485, Optional:PLC


EMI DC/DC
AC A
PV4
-+

Filter AC
DC/AC
Filter
EMI B Certificates and approvals (more available on request) IEC 62109, IEC 61727, IEC 61683, IEC 62116, IEC 60068, IEC 61000, EN 50530
Filter
DC SPD C
MPPT3
Dimensions (W×H×D) 910×572×285mm
PV5

DC
-

EMI DC/DC
Weight 58kg
-+
PV6

Filter

AC SPD
DC SPD MPPT4 (1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
PV7

DC (2) When above 3000m, the inverter begins derating, contact us for derating parameters
-

EMI DC/DC
-+
PV8

Filter

DC SPD

Copyright 2018 SINENG. All rights reserved.


47 Specifications subject to change without notice. 48
SP-40K
SP Series String Solar Inverter

Input (DC)
Max. PV input voltage 1100V

Max. input current 88A

Rated input voltage 620V


More power generation
Max. efficiency 99%, Euro efficiency 96% MPP voltage range 200~1000V
4 MPPTs for tracking maximum PV power MPP voltage range for nominal power 480~800V

Number of MPPT trackers 4

Max. number of PV strings per MPPT 2

Output (AC)
Rated output power 38kW
Low system cost Max. output power 42kW
Power line communication save cable cost and civil work
Rated grid voltage 400V
High DC/AC ratio for lower LCOE
Grid voltage range 340~440V

Max. output current 60.8A

Rated grid frequency / range 50 Hz/45~55Hz, 60Hz/55~65Hz

Output current harmonic(at nominal power) <3%


High reliability
Power factor at nominal power / range >0.99/0.8 lagging to 0.8 leading
Natual cooling without fan for harsh environment
and long life Protection
String monitoring function, easy for quick trouble
DC reverse connection protection Circuit breaker
shooting
Overvoltage protection DC Type II/AC Type II

Leakege current protection Yes

Grid monitoring Yes

Insulation monitoring Yes


Grid friendly
Anti-island protection Yes
Active power derating and reactive power adjustable
Low harmonics and fast response for grid regulation Anti-PID function Optional

Efficiency
Max. efficiency 99%

EU efficiency 98.60%

General Data

Circuit Self-consuming in standby <3W

Protection level IP65

DC Switch DC Bus Noise <35dB


MPPT1
(1)
PV1
-+

DC Temperature ﹣30℃~+60℃
EMI DC/DC
PV2
-+

Filter
Cooling mode Natural cooling
DC SPD Inverter Circuit AC relay
MPPT2 Altitude at full load (2) 3000m
-+
PV3

DC
EMI DC/DC A Communication port Standard:RS485, Optional:GPRS
AC
PV4
-+

Filter AC
DC/AC EMI B
Filter
Filter
C Certificates and approvals (more available on request) IEC 62109, IEC 61727, IEC 61683, IEC 62116, IEC 60068, IEC 61000, EN 50530
DC SPD MPPT3
PV5

DC Dimensions (W×H×D) 910×572×285mm


-

EMI DC/DC
-+
PV6

Filter
Weight 58kg
DC SPD AC SPD
MPPT4
(1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
PV7

DC
-

EMI DC/DC (2) When above 3000m, the inverter begins derating, contact us for derating parameters
-+
PV8

Filter

DC SPD

Copyright 2018 SINENG. All rights reserved.


49 Specifications subject to change without notice. 50
SP-20K
SP Series String Solar Inverter

Input (DC)
Max. PV input voltage 1000V

Max. input current 42.6A

Rated input voltage 620V

MPP voltage range for nominal power 280~820V

Number of MPPT trackers 2

More power generation Max. number of PV strings per MPPT 2


Max. efficiency 98.6%, Euro efficiency 98.4% Output (AC)
2 MPPTs for tracking maximum PV power 20kW
Rated output power

Max. output power 22kW

Rated grid voltage 400V

Grid voltage range 340~440V


High reliability Max. output current 31.9A
Natual cooling for harsh environment and long life
Rated grid frequency / range 50 Hz/45~55Hz, 60Hz/55~65Hz
String monitoring function, easy for quick trouble
shooting Output current harmonic(at nominal power) <3%

Power factor at nominal power / range >0.99/0.9 lagging to 0.9 leading

Protection
DC reverse connection protection Circuit breaker

Overvoltage protection DC Type II/AC Type III


Grid friendly Leakege current protection Yes
Active power derating and reactive power adjustable
Grid monitoring Yes
Low harmonics and fast response for grid regulation
Insulation monitoring Yes

Anti-island protection Yes

Anti-PID function Optional

Efficiency
Max. efficiency 98.60%

EU efficiency 98.40%

General Data
Self-consuming in standby <3W

Circuit Protection level IP65

Noise <30dB
(1)
Temperature ﹣30℃~+60℃

Cooling mode Natural cooling


DC Switch DC Bus
MPPT1 Altitude at full load (2) 3000m
PV1
-+

DC Inverter Circuit AC relay Communication port Standard: RS485; Optional: Wireless


EMI DC/DC
PV2
-+

Filter Certificates and approvals (more available on request) IEC 62109, IEC 61727, IEC 61683, IEC 62116, IEC 60068,IEC 61000, EN 50530
A
AC
AC Dimensions (W×H×D) 540×750×275 mm
DC SPD DC/AC EMI B
MPPT2 Filter
Filter
C Weight 45 kg
-+
PV3

DC
EMI DC/DC
(1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
PV4
-+

Filter
(2) When above 3000m, the inverter begins derating, contact us for derating parameters
DC SPD
AC SPD

Copyright 2018 SINENG. All rights reserved.


51 Specifications subject to change without notice. 52
SP-5K
SP Series String Solar Inverter

Input (DC)
Max. PV input voltage 600V

Max. input current 22A

Rated input voltage 360V

MPP voltage range 90~520V

MPP voltage range for nominal power 240~480V

More power generation Number of MPPT trackers 2


High conversion efficiency Max. number of PV strings per MPPT 1
Wide MPPT voltage range
Output (AC)
Rated output power 5000W

Max. output power 5000W

Rated grid voltage 220V


Safty and reliability Grid voltage range 180~276V
Natural cooling for longer life
Max. output current 24A
String monitoring function, easy for quick
trouble shooting Rated grid frequency / range 50 Hz/45~55Hz
IP65 protection level
Output current harmonic(at nominal power) <3%

Power factor at nominal power >0.99


Protection
DC reverse connection protection Yes
Smart and friendly Overvoltage protection Type II
Plug&Play installation
Leakege current protection Yes
Wifi & GPRS selectable
Grid monitoring Yes

Insulation monitoring Yes

Anti-island protection Yes

DC Switch Optional

Efficiency
Max. efficiency 98.10%

EU efficiency 97.30%

General Data
Circuit Self-consuming in standby <0.5W

Protection level IP65

Noise <25dB
(1)
Temperature -25℃~+60℃
DC Switch DC Bus Cooling mode Natural cooling
MPPT1
Inverter Circuit AC relays
Altitude at full load (2) 3000m
PV2 PV1

DC

EMI DC/DC
Filter Communication port Standard: RS232; Optional:Wifi,GPRS
L
-

AC
AC
DC/AC EMI Dimensions (W×H×D) 367×465×158 mm
Filter
Filter N
MPPT2
Weight 13.3 kg
PV4 PV3

DC PE

EMI DC/DC
Filter (1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
-

AC SPD (2) When above 3000m, the inverter begins derating, contact us for derating parameters

Copyright 2018 SINENG. All rights reserved.


53 Specifications subject to change without notice. 54
SP-3K
SP Series String Solar Inverter

Input (DC)
Max. PV input voltage 550V

Max. input current 13A

Rated input voltage 360V

MPP voltage range 90~520V

MPP voltage range for nominal power 240~440V

Number of MPPT trackers 1


More power generation
High conversion efficiency Max. number of PV strings per MPPT 1
Wide MPPT voltage range Output (AC)
Rated output power 3000W

Max. output power 3000W

Rated grid voltage 220V

Grid voltage range 180~276V


Safty and reliability Max. output current 14.5A
Natural cooling for longer life
IP65 protection level Rated grid frequency / range 50 Hz/45~55Hz

Output current harmonic(at nominal power) <3%

Power factor at nominal power >0.99


Protection
DC reverse connection protection Yes

Smart and friendly Overvoltage protection AC Type II


Plug&Play installation Leakege current protection Yes
Wifi & GPRS selectable
Grid monitoring Yes

Insulation monitoring Yes

Anti-island protection Yes

DC Switch Optional

Efficiency
Max. efficiency 97.50%

EU efficiency 97.00%

General Data
Circuit Self-consuming in standby <0.5W

Protection level IP65

Noise <25dB
(1)
Temperature -25℃~+60℃

DC Bus Cooling mode Natural cooling


Inverter Circuit AC relays
MPPT Altitude at full load (2) 3000m
DC Switch

AC L Communication port Standard: RS232; Optional:Wifi,GPRS


DC AC
EMI DC/DC DC/AC EMI
PV

Filter 302×362×118mm
Filter Filter N Dimensions (W×H×D)
-

PE Weight 7.6kg

AC SPD (1) When ambient temperature is under -30℃, the inverter needs to be configured with heater(optional)
(2) When above 3000m, the inverter begins derating, contact us for derating parameters

Copyright 2018 SINENG. All rights reserved.


55 Specifications subject to change without notice. 56

Вам также может понравиться