1. The maximum rented space in an Office building. (Planning & Designers Handbook, Max
Fajardo pg. 148)
a. 75% b. 80% c. 85% d. 60%
2. Minimum size of a private office. (Planning & Designers Handbook, Max Fajardo pg.
149)
a. 8 sqm b. 9 sqm c. 10 sqm d. 12 sqm
3. Satisfactory width of a dining table. (Planning & Designers Handbook, Max Fajardo
pg. 20)
a. 95 – 110 cm b. 90 – 120 cm c. 95 – 150 cm d. 90 – 100 cm
13. Rooms intended for any use, not provided with artificial ventilation system,
shall be provided with a windows with a total free area of openings equal to at
least 10% of the floor area of the room, provided that such opening shall be not
less than ______ sq. meter.? (NBC Sect 808)
a. 0.80 sqm c. 1.20 sqm
b. 1.00 sqm d. 1.80 sqm
14. Minimum height of carrier door. (Ref. Planning & Design, Max Fajardo, pg 338)
a. 3.10 mts c. 3.90 mts
b. 3.50 mts d. 4.30 mts
15. Which of the following is a good lightig device for a general production area
with the ceiling consisting soffit of a suspended slab?
a. Pendant Lighting (suspended CFL with housing)
b. Troffer Lighting (Flourescent lamps with soffit-mounted light box and
diffusers)
c. Industrial Lighting (suspended flourescent lamps with reflectors)
d. Pendant Lighting (suspendent incandescent lamps)
16. Least dimension of room for human habitation. (Sec 806, NBC)
a. 1.2m c. 2m
b. 1.5m d. 2.1m
17. Minimum size of room for human habitation. (Sec 806, NBC)
a. 4 sqm c. 6 sqm
b. 5 sqm d. 7.5 sqm
21. In residential, the table requirement per person for a crowded seating is
ranged from ________ cm on table perimeter. (Ref.: Planning & Design, Max Fajardo,
page 19)
a. 50 to 55cm c. 40 to 45cm
b. 60 to 65cm d. NOTA
22. In residential, the minimum clearance between wall and furniture is ______.
(Ref.: Planning & Design, Max Fajardo, page 31)
a. 2 to 4cm c. 8 to 10cm
b. 5 to 7cm d. 12 to 15cm
25. 5. On low buildings, the elders should not climb s stair more than one flight.
Likewise, ramp should not be more than ___ slope.(Ref.: Planning & Design, Max
Fajardo, pg 83)
a. 5 percent c. 8 percent
b. 10 percent d. 12 percent
26. In Offices, what is the suitable distance of desk from the front to the desk
behind it? (Ref.: Planning & Design, Max Fajardo, pg 139)
a. 1.50 mts c. 2.10 mts
b. 1.80 mts d. 2.50 mts
27. With reference to question#6, the distance should be increased to ___ when the
desks are in rows of two. (Ref.: Planning & Design, Max Fajardo, pg 139)
a. 1.50 mts c. 2.10 mts
b. 1.80 mts d. 2.50 mts
28. In Bus Terminals there are four types of platform loading. ______ is considered
as the most efficient type which requires a minimum front. The wide space at the
rear permits an easy maneuvering of the bus. (Ref. Planning & Design, Max Fajardo,
pg 332)
a. Parallel Loading c. Right Angle Loading
b. Radial Saw-tooth Loading d. NOTA
29. Bus Terminals are classified into four categories. ______ is usually in
downtown core accessible directly by local bus, taxi and auto. This type of
terminal includes long haul or package express services and provides greater number
of bus movements. (Ref. Planning & Design, Max Fajardo, pg 327).
a. Inter City Bus Terminal c. Airport City Terminal
b. Urban Suburban Commuter Terminal d. Suburban Inter Province Terminal
30. Other classified Bus terminal is a passenger collection and distribution center
or a rapid transit feeder station. It is characterized by a diversified bus route
and high turnover commuter type bus operation (Ref. Planning & Design, Max Fajardo,
pg 327)
a. Inter City Bus Terminal c. Airport City Terminal
b. Urban Suburban Commuter Terminal d. Suburban Inter Province Terminal
31. With reference to Image-A. The ramp breakover angle for slope should not be
greater than ___. (Ref.: Planning & Design, Max Fajardo, pg 181)
a. 8 degrees c. 12 degrees
b. 10 degrees d. 15 degrees
32. For Residential, a simple passage for back seated chair should have a minimum
clearance of ___. As shown in Image-B (Ref. Planning & Design, Max Fajardo, pg 15)
a. 40 cm c. 90 cm
b. 60 cm d. 100 cm
a. 160 cm c. 180 cm
b. 170 cm d. 190 cm
34. For Residential, a simple passage between low objects such as sofa and coffee
table, the pathway should have a minimum clearance of ___.(Ref. Max Fajardo, pg 15)
a. 40 cm c. 90 cm
b. 60 cm d. 100 cm
35. In human cone of vision, what is the angle of intense focus area? (Ref
https://sereaportfolio.wordpress.com/2013/02/20/02-environmental-studies-haji-
lane/)
a. 20 degrees c. 45 degrees
b. 30 degrees d. 60 degrees
36. An Apartment that is not more than 4 storeys. (Ref. Arch design 01. pg 3)
a. Apartelle c. Tenement
b. Condotelle d. Townhouse
37. A luxurious facilities for water vessels, yachts and lavish fine dining can be
found.(Ref. Arch design 01. pg 3)
a. Marina c. Promenade
b. Bay d. Corniche
38. Is an approach to architectural design that considers the entire range of
capacities and potentials of people and how they use buildings and products
throughout their lives. (Time-Savers Standards for Archl . Design Data 7TH Ed. p3)