iPASOLINK 100E
SECTION III MAINTENANCE
CONTENTS
CONTENTS ............................................................................................................................- 1 -
1. General.......................................................................................................................... 1-1
2. Precaution .................................................................................................................... 2-1
2.1 Maintenance and Operation Manual ....................................................................................... 2-4
2.1.1 Wrist Strap Connection.................................................................................................... 2-4
2.1.2 Maintenance Mode Setting (for the LCT Operation) ........................................................ 2-4
2.1.3 Manual Switch Operation ................................................................................................ 2-5
3. Test Sets and Accessories ......................................................................................... 3-1
4. Current Status .............................................................................................................. 4-1
4.1 Current Status......................................................................................................................... 4-1
5. Routine Maintenance ................................................................................................... 5-1
5.1 Meter Reading ........................................................................................................................ 5-1
5.2 Performance Monitoring ......................................................................................................... 5-3
5.2.1 PM Parameters ............................................................................................................... 5-3
5.2.1.1 PM Status Monitor Types ....................................................................................... 5-3
6. Corrective Maintenance .............................................................................................. 6-1
6.1 Alarm/Status ........................................................................................................................... 6-2
6.1.1 Alarm Management ......................................................................................................... 6-4
6.1.1.1 Alarm Class............................................................................................................ 6-4
6.1.2 Alarm and Status Indication Detail .................................................................................. 6-5
6.1.2.1 ODU Alarms & Status ............................................................................................ 6-5
6.1.2.2 MODEM Alarms & Status ...................................................................................... 6-6
6.1.2.3 ETH GRP Alarm..................................................................................................... 6-7
6.1.2.4 IDU Alarms & Status .............................................................................................. 6-7
6.1.2.5 IEEE802.3ah Alarm ............................................................................................... 6-9
6.1.2.6 TCN Alarms ........................................................................................................... 6-9
7. Control Items ................................................................................................................ 7-1
7.1 Loopback ................................................................................................................................ 7-2
7.1.1 Link OAM Loopback ........................................................................................................ 7-2
7.2 Equipment Maintenance ......................................................................................................... 7-5
Maintenance NWD-142958-01E
-2-
NWD-142958-01E Maintenance
-3-
Maintenance NWD-142958-01E
-4-
NWD-142958-01E Maintenance
General 1-1
1. GENERAL
This section provides information on routine and corrective maintenance for the
iPASOLINK used for 6 to 42 GHz Packet digital radio system.
Maintenance NWD-142958-01E
1-2 General
NWD-142958-01E Maintenance
Precaution 2-1
2. PRECAUTION
The maintenance personnel should report arrival and departure from a station to the
relevant station. The following precaution must be carefully observed during
maintenance.
Warning
1. The -48V DC power is superimposed on the centre conductor of the coaxial
cable between the IDU and the ODU. Connecting test equipment directly to
this terminal may damage it and touching the coaxial cable core may cause
electrical shock.
Caution
1. In a system using the optical interface, do not stare at the laser beam or look
at it directly with optical instruments. Otherwise, it may hurt your eyes (Class
1 laser product)
2. The surface of the IDU is hot in operation.
3. When replacing the IDU, turn off the IDU and disconnected all cables.
4. During maintenance, the IDU should be set to maintenance ON by the LCT.
5. While the CPU is initialized by the CPU RESET switch, alarm(s) status is
reset to normal. After initialized, the alarm information is properly provided
through relay contacts.
Maintenance NWD-142958-01E
2-2 Precaution
6. Information on the maintenance and the control such as Mute, CW, LB etc.
is released if the power is turned off.
7. If each setup item of NE SETUP or SYSTEM OPERATION is changed
during in operation, traffic will be momentarily interrupted.
8. After completing maintenance, restore all connections, manual control
settings to normal and confirm that all alarm LEDs are unlit.
9. After equipment start-up, allow the equipment to warm up at least 30
minutes.
NWD-142958-01E Maintenance
Precaution 2-3
Straight Type
Tighten the TNC-male connector of IF cable to the IDU with engage connector nut
only using fingers and holding the cable with another hand.
L-angle Type
Tighten the engage connector nut only for the L-angle connector also.
(Tightening Torque: 0.3 to 0.5 N-m (3 to 5kg. Cm))
If rotate other parts of the L-angle connector as illustrated left, it can cause connector
damage.
Maintenance NWD-142958-01E
2-4 Precaution
Procedure 2-1
Procedure 2-2
2. Confirm that the MAINT on the top of the LCT window becomes yellow.
NWD-142958-01E Maintenance
Precaution 2-5
3. And also confirm that the MAINT LED at the front of the equipment becomes
yellow.
RSTP Control
Procedure 2-3
Maintenance NWD-142958-01E
2-6 Precaution
8. The RSTP / MSTP Control window appears again. Confirm the parameters
displayed.
9. After finishing RSTP Control, click Maintenance button on the top of the LCT
window to exit maintenance mode.
NWD-142958-01E Maintenance
Precaution 2-7
(2) Timing Source Switch Control (This mode available when the Lock
Out is Off only)
In case that Lock Out Status is set to On, follow the Procedure 2-7 to change the
setting to Off and then follow the Procedure 2-8 to configure Timing Source
Switching.
Procedure 2-4
4. Select Timing Source Switch Control from the Protection Control sub
menu.
5. The Timing Source Switch Control window appears. Click desired Lock
Out to configure.
Maintenance NWD-142958-01E
2-8 Precaution
6. The Timing Source Switch Control box appears. Select Off from Lock Out.
7. Click OK button.
9. The Timing Source Switch Control window appears again. Confirm the
parameters displayed.
10. After finishing Lock Out Setting, click Maintenance button on the top of the
LCT window to exit maintenance mode.
NWD-142958-01E Maintenance
Precaution 2-9
Procedure 2-5
4. Select Timing Source Switch Control from the Protection Control sub
menu.
5. The Timing Source Switch Control window appears. Click the desired
Timing Source Switch Control to configure.
Click.
6. The Timing Source Switch Control box appears. Select specify switching
mode (Manual SW or Forced SW).
7. Click OK button.
Maintenance NWD-142958-01E
2-10 Precaution
10. The Timing Source Switch Control window appears again. Confirm the
parameters displayed.
11. Click Maintenance button on the top of the LCT window to exit maintenance
mode.
NWD-142958-01E Maintenance
Test Sets and Accessories 3-1
The test sets and special accessories listed in Table 3-1 are required for maintenance.
If recommended test sets and accessories are not available, equivalents may be used.
Maintenance NWD-142958-01E
3-2 Precaution
NWD-142958-01E Maintenance
Current Status 4-1
4. CURRENT STATUS
But it is just for viewing system status only you can not make any changes of all
items displayed on this window. (Such as modify, adding, masking alarms or items)
The Active Alarm tab displays all current alarms detected on the equipment
side.
You can download the current alarm list to LCT PC by clicking Save button
on the top left of the Active Alarm tab.
The Event Log tab displays all alarms and status detected when there is any
changed on the line card and configuration on equipment.
You can download the Event Status list to the LCT PC by clicking Save
button on the top left of the Event Log tab.
Maintenance NWD-142958-01E
4-2 Current Status
1. Click Save button of the Active Alarm tab or the Event Log tab.
NWD-142958-01E Maintenance
Current Status 4-3
3. The Save As window appears. Select the proper folder of the Local PC, and
then click Save button.
Maintenance NWD-142958-01E
4-4 Current Status
4. After finishing the export of log file, the Download Complete window
appears. Click Close button.
NWD-142958-01E Maintenance
Current Status 4-5
The ODU tab displays all alarm and status detected on ODU.
The IDU tab displays all alarms and status detected on IDU.
Maintenance NWD-142958-01E
4-6 Current Status
NWD-142958-01E Maintenance
Routine Maintenance 5-1
5. ROUTINE MAINTENANCE
This chapter provides the routine (annually) maintenance procedures to ensure the
satisfactory operation of the equipment. During routine maintenance, carefully
observe the precautions given in Chapter 2.
Procedure 5-1
Maintenance NWD-142958-01E
5-2 Routine Maintenance
Notes
1. If an abnormal indication appears, check Alarm/Status, performance monitor
and perform loopback test to distinguish sections of normal and alarmed.
2. RX LEVEL varies depending on received RF signal level.
3. Power Supply voltage at ODU varies depending of IF cable length between
the IDU and ODU.
NWD-142958-01E Maintenance
Routine Maintenance 5-3
5.2.1 PM Parameters
Performance Monitor Parameters can be measured from iPASOLINK.
Maintenance NWD-142958-01E
5-4 Routine Maintenance
NWD-142958-01E Maintenance
Routine Maintenance 5-5
Maintenance NWD-142958-01E
5-6 Routine Maintenance
NWD-142958-01E Maintenance
Routine Maintenance 5-7
Maintenance NWD-142958-01E
5-8 Routine Maintenance
NWD-142958-01E Maintenance
Routine Maintenance 5-9
Maintenance NWD-142958-01E
5-10 Routine Maintenance
NWD-142958-01E Maintenance
Corrective Maintenance 6-1
6. CORRECTIVE MAINTENANCE
Faults can be classified in to those that cause deterioration of the transmission quality
and those that interrupt the traffic due to a malfunction of the equipment. This
chapter explains the troubleshooting procedures for equipment faults and the
corresponding remedial methods. The purpose of troubleshooting malfunctioning
equipment is to restart the service by locating the faulty part and replacing it with a
spare.
The faults that cause deterioration quality are primarily originated by changes
occurred in the state of propagation. Therefore, if a decline in the transmission
quality or similar fakes place frequently, the link design will have to be reviewed.
Maintenance NWD-142958-01E
6-2 Corrective Maintenance
6.1 Alarm/Status
When an alarm event has occurred, at first, check alarm indication on the front of the
IDU. Continuously, connect the PC to the LOCAL jack on the LCT port mounted on
the IDU and check alarm/status indication.
A faulty part can be located by checking the ALARM LED indications and LCT
Alarm indications.
Alarm Report
When an alarm is detected, alarm notification is made to the user by lighting
up the LEDs on the rack, and reporting the alarm to user interface. The alarm
notification is also made to the user by an Office alarm, such as the station
alarm bell and lamps.
Web-LCT indication
The alarm LED indications faulty part can be located by checking the ALM
LED indicators and Web-LCT Alarm indications.
NWD-142958-01E Maintenance
Corrective Maintenance 6-3
Meter Reading
Maintenance NWD-142958-01E
6-4 Corrective Maintenance
Critical (CR) :
The Critical severity level indicates that a service affecting condition has occurred
and an immediate corrective action is required. Such a severity can be reported, for
example, when a managed object becomes totally out of service and its capability
must be restored.
Major (MJ):
The Major severity level indicates that a service affecting condition has developed
and an urgent corrective action is required. Such a severity can be reported, for
example, when there is a severe degradation in the capability of the managed object
and its full capability must be restored.
Minor (MN):
The Minor severity level indicates the existence of a non-service affecting fault
condition and that corrective action should be taken in order to prevent a more
serious (for example, service affecting) fault. Such a severity can be reported, for
example, when the detected alarm condition is not currently degrading the capacity
of the managed object.
Warning (WR):
The Warning severity level indicates the detection of a potential or impending
service affecting fault, before any significant effects have been felt. Action should be
taken to further diagnose (if necessary) and correct the problem in order to prevent it
from becoming a more serious service affecting fault.
NWD-142958-01E Maintenance
Corrective Maintenance 6-5
Maintenance NWD-142958-01E
6-6 Corrective Maintenance
NWD-142958-01E Maintenance
Corrective Maintenance 6-7
Maintenance NWD-142958-01E
6-8 Corrective Maintenance
NWD-142958-01E Maintenance
Corrective Maintenance 6-9
Maintenance NWD-142958-01E
6-10 Corrective Maintenance
NWD-142958-01E Maintenance
Control Items 7-1
7. CONTROL ITEMS
Following control items is available when the maintenance mode is on only. And be
careful during the operation on these control items. Because there is possibility to be
traffic affected during operation.
Loopback Control
Database Upload/Download
- FW Reset Control
Radio Control
License Management
Maintenance NWD-142958-01E
7-2 Control Items
Inventory Information
Performance Monitor
Offline Maintenance
7.1 Loopback
When executing the loopback control, set Maintenance Mode to ON and do not
release Maintenance Modes while controlling loopback.
NWD-142958-01E Maintenance
Control Items 7-3
Procedure 7-1
3. Expand the Loopback Control from the Maintenance Control sub menu.
4. Select the Link OAM Loopback from the Loopback Control sub menu.
5. The Link OAM Loopback Control window appears. Click Off at the
Loopback Status field.
6. The Link OAM Loopback Control (Main Board - Port01) box appears.
Click On for specified OAM Link Loopback Port.
Figure 7-3 Link OAM Loopback Control (Main Board - Port01) Box
Maintenance NWD-142958-01E
7-4 Control Items
8. The Link OAM Loopback Control window appears again. Confirm that the
status of Loopback Status is displayed On.
9. After finishing loopback test, click Maintenance button on the top of the LCT
window to exit maintenance mode.
NWD-142958-01E Maintenance
Control Items 7-5
Provisioning Clear
Use this function to clear Provisioning setting from Main Board.
Procedure 7-2
2. Select the Export (NE->Storage) Utility from the Equipment Utility sub
menu.
Maintenance NWD-142958-01E
7-6 Control Items
NWD-142958-01E Maintenance
Control Items 7-7
5. The Save As window appears. Select the specified directory on the specified
device (local PC) and then click Save button.
Maintenance NWD-142958-01E
7-8 Control Items
NWD-142958-01E Maintenance
Control Items 7-9
This function is used for downloading F/Ws from Local PC to the targets. (Main
Board, ODU)
This function is used to update the MODEM parameter file on the MODEM
section of the Main Board.
Importance:
1. Confirm that you have IDU Main Board Program File that is provided from
NEC.
2. Confirm the current version of IDU Main Board Program File from the IDU
tab of Equipment Inventory Information window.
3. Turn on the Maintenance Mode before downloading IDU Main Board
Program File. And do not release Maintenance Mode while downloading.
Maintenance NWD-142958-01E
7-10 Control Items
Procedure 7-3
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode on.
3. Select the Update (Storage->NE) Utility from the Equipment Utility sub
menu.
5. The source selection window appears. Select destination storage (Local PC)
from the Import File field and then click File icon button.
NWD-142958-01E Maintenance
Control Items 7-11
6. The file selection window appears. Select the Main Board firmware file and
then click Open (or OK) button.
Local PC
Maintenance NWD-142958-01E
7-12 Control Items
10. After the download is completed, the Update Complete! window appears.
Check the Program ROM Switching check box and then click OK button.
NWD-142958-01E Maintenance
Control Items 7-13
Note: If the check box of Program ROM Switching is not checked, you have to
execute Program ROM Switching later by manually. (For more detail
refer to 7.2.1.3 Program ROM Switching)
And use in the following case.
1. When suppose to download Program File data to NE only and update NE in
other days.
2. When suppose to update multiple NEs in one time.
3. When suppose to continue downloads another data and then executes the
update one time.
4. Program ROM will be switched to new version after equipment restart. You
can confirm running version in Equipment Inventory Information Window.
11. The Warning box appears. Click OK button. iPASOLINK will be restarted
automatically.
12. The Information box appears. Click OK button. The WebLCT will shutdown
automatically.
Maintenance NWD-142958-01E
7-14 Control Items
14. Select the Inventory (Equipment Inventory Information) from the LCT
menu.
16. After finishing Program File download, click Maintenance button on the top
of the LCT window to exit maintenance mode.
NWD-142958-01E Maintenance
Control Items 7-15
(b) ODU
Importance:
1. Confirm that you have ODU Program File that is provided from NEC.
2. Confirm the current version of ODU Program File from the ODU tab of the
Equipment Inventory Information window.
3. Turn on the Maintenance Mode before download ODU Program File. And do
not release Maintenance Mode while downloading.
Procedure 7-4
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode ON.
3. Select the Update (Storage->NE) Utility from the Equipment Utility sub
menu.
Maintenance NWD-142958-01E
7-16 Control Items
5. The Update (Storage->NE) Utility box (1/2) appears. Select the ODU from
drop-down list and then click Next button.
The source selection window appears. Select destination storage (Local PC) from
the Import File field and then click File icon button.
NWD-142958-01E Maintenance
Control Items 7-17
6. The file selection window appears. Select the ODU firmware file and then click
Open (or OK) button.
Local PC
Maintenance NWD-142958-01E
7-18 Control Items
10. After the download is completed, the Update Complete! window appears.
Check the Program ROM Switching check box and then click OK button.
NWD-142958-01E Maintenance
Control Items 7-19
Note: If the checkbox of Program ROM Switching is not checked you have to
execute Program ROM Switching later by manually. (For more detail
refer to 7.2.1.3 Program ROM Switching)
11. The Warning box appears. Click OK button. iPASOLINK will be restarted
automatically.
Maintenance NWD-142958-01E
7-20 Control Items
12. The Information box appears. Click OK button. The WebLCT will shutdown
automatically.
14. Select the Inventory (Equipment Inventory Information) from the LCT
menu.
16. After finishing Program File download, click Maintenance button on the top
of the LCT window to exit maintenance mode.
NWD-142958-01E Maintenance
Control Items 7-21
Importance:
Upload existing Configuration Data File.
Note:
1. Do not use the same folder between Exist Configuration Data File and Data
for Download that allows comparison of each Data.
2. When executing the Configuration Data download, set Maintenance Mode to
on and do not release Maintenance Modes while controlling download.
Procedure 7-5
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode on.
3. Select the Update (Storage->NE) Utility from the Equipment Utility sub
menu.
Maintenance NWD-142958-01E
7-22 Control Items
5. The source selection window appears. Select the specific Config Data Type
(Network Config, Equipment Config, Partial Equipment Config, User Config).
6. Select destination storage (Local PC) from the Import File field and then
click File icon button.
7. The file selection window appears. Select the Config Data file and then click
Open (or OK) button.
Local PC
NWD-142958-01E Maintenance
Control Items 7-23
8. The source selection window appears again. When selected source is other
than Partial Equipment Config, click OK button, and proceed to step 11.
Maintenance NWD-142958-01E
7-24 Control Items
NWD-142958-01E Maintenance
Control Items 7-25
13. The Update Complete! window appears after downloading. Then auto-revert
should be executed by clicking OK button.
14. The Information box appears. Click OK button. The WebLCT will shutdown
automatically.
16. Upload the Configuration Data File again and then acquire the Configuration
Data.
17. Confirm the latest Configuration Data running by comparing the newly
acquired Configuration Data to that acquired before download.
Maintenance NWD-142958-01E
7-26 Control Items
Importance:
1. Confirm specific Parameter File for MODEM was already acquired from
NEC.
2. Confirm specific Parameter File for MODEM.
3. When executing the MODEM Parameter Download, set Maintenance Mode
to ON and do not release Maintenance Modes while controlling Download.
Procedure 7-6
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode ON.
3. Select the Update (Storage->NE) Utility from the Equipment Utility sub
menu.
NWD-142958-01E Maintenance
Control Items 7-27
6. The source selection window appears. Select the destination storage (Local
PC) from the Import File field and then click File icon button.
Maintenance NWD-142958-01E
7-28 Control Items
7. The file selection window appears. Select the MODEM Parameter file and then
click Open (or OK) button.
Local PC
NWD-142958-01E Maintenance
Control Items 7-29
11. The Update Complete! window appears after downloading. Then auto-revert
should be executed by clicking the OK button.
12. After restarting, open the window of specific MODEM and then confirm the
latest MODEM Parameter Data running by comparing the confirmed parameter
of specific MODEM.
Maintenance NWD-142958-01E
7-30 Control Items
An SSL server certificate file that is supported in the iPASOLINK is a zip file.
This file must include public key and secret key as follows:
iPASOLINK-serverAAA.zip
|
+---- BBB.crt
+---- BBB.key
Procedure 7-7
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode ON.
NWD-142958-01E Maintenance
Control Items 7-31
5. The source selection window appears. Select the destination storage (Local
PC) from the Import File field and then click File icon button.
6. The file selection window appears. Select the SSL Server Certificate file and
then click Open (or OK) button.
Local PC
Maintenance NWD-142958-01E
7-32 Control Items
NWD-142958-01E Maintenance
Control Items 7-33
12. After finishing SSL Server Certificate download, click Maintenance button
on the top of the LCT window to exit maintenance mode.
Maintenance NWD-142958-01E
7-34 Control Items
Importance:
1. When executing the Program ROM Switching, set Maintenance Mode to ON
and do not release Maintenance Modes while controlling Switching.
Procedure 7-8
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode on.
3. Select the Program ROM Switching from the Equipment Utility sub
menu.
4. The Program ROM Switching window appears. Click the Main Board in
the Item field.
5. The Program ROM Switching (Main Board) box appears. Confirm the
information then click OK button.
NWD-142958-01E Maintenance
Control Items 7-35
7. The Information box appears. Click OK button. The WebLCT window will
shutdown automatically.
9. Select the Equipment Utility (Program ROM Switching) from the LCT
menu.
10. Confirm the Current version of the Main Board in the Program ROM
Switching window.
11. After finishing Program ROM Switching, click Maintenance button on the
top of the LCT window to exit maintenance mode.
Maintenance NWD-142958-01E
7-36 Control Items
Importance:
When executing the Program ROM Switching, set Maintenance Mode to ON and
do not release Maintenance Modes while controlling Switching.
Procedure 7-9
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode on.
3. Select the Program ROM Switching from the Equipment Utility sub
menu.
4. The Program ROM Switching window appears. Click the ODU No. in the
Item field.
NWD-142958-01E Maintenance
Control Items 7-37
8. After restarting, confirm the Current version of ODU in the Program ROM
Switching window.
Maintenance NWD-142958-01E
7-38 Control Items
Procedure 7-10
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode on.
5. The Shipment box appears. Select the Provisioning Clear from the
drop-down list and then click OK button.
NWD-142958-01E Maintenance
Control Items 7-39
8. The Information box appears. Click OK button The WebLCT will shutdown
automatically.
Maintenance NWD-142958-01E
7-40 Control Items
Procedure 7-11
2. Select the Date / Time setting from the Equipment Utility sub menu.
4. The Date / Time Setting box appears. Refer to the table below to assign a
proper value for each parameter accordingly.
NWD-142958-01E Maintenance
Control Items 7-41
7. The Date/Time Setting window appears again. Confirm the modified date
and time of the information displayed.
Maintenance NWD-142958-01E
7-42 Control Items
Reset control available only when Maintenance Mode is On. If Maintenance Mode is
Off, Reset control will return the error response.
NWD-142958-01E Maintenance
Control Items 7-43
Procedure 7-12
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode on.
3. Expand the H/W / F/W Reset Control from the Maintenance Control sub
menu.
4. Select the F/W Reset Control from the H/W / F/W Reset Control sub
menu.
5. The F/W Reset Control window appears. Click Main Board in the Item
field.
Main Board
6. The F/W Reset Control box appears. Confirm the information then click OK
button.
Maintenance NWD-142958-01E
7-44 Control Items
8. The Information box appears. Click OK button. The WebLCT window will
shutdown automatically.
11. After finishing Reset Control, click Maintenance button on the top of the
LCT window to exit maintenance mode.
NWD-142958-01E Maintenance
Control Items 7-45
Procedure 7-13
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode on.
3. Select the H/W / F/W Reset Control from the Maintenance Control sub
menu.
4. Select the F/W Reset Control from the H/W / F/W Reset Control sub
menu.
5. The F/W Reset Control window appears. Click ODU (No.1) in the Item
field.
ODU (No.1)
6. The F/W Reset Control box appears. Confirm the information then click OK
button.
Maintenance NWD-142958-01E
7-46 Control Items
9. The CPU Reset (ODU) starts automatically. Confirm the current status on the
ODU tab.
10. After finishing Reset Control, click Maintenance button on the top of the
LCT window to exit maintenance mode.
NWD-142958-01E Maintenance
Control Items 7-47
The function of each control is as follows (These windows are not available when
MAINT is OFF. Switch to Maintenance mode first is displayed).
If TX Power Control Mode selects ATPC Mode, execute temporally fix control
to transmit POWER. Select the value range described in ( ) of ATPC Range that
located in the Provisioning Menu (MODEM Function setting -> TX Power
Setting) for Transmit POWER. ATPC Manual Control available to select the
either Auto or Manual. If transmit POWER is required to fix control temporarily,
select Manual then select fixed value and it will be fixed until selecting Auto.
TX Mute Control
Despite the equipment configuration setting, forcing the “TX Mute Control” to
ON, the transmit power of the ODU will stop.
Notes
1. IF Mute Control is set to OFF and due to uncontrollable factors Mute OFF
does not work, Mute status will remain on.
2. When TX Mute is controlled by a remote control, it is possible to set the
automatic restoration time. Therefore, TX Mute Release Time is set.
3. TX Mute Release Time is set together with TX Mute Control by the item that
becomes effective only when TX Mute Control is done from a higher-level
device.
Maintenance NWD-142958-01E
7-48 Control Items
CW Control
The flat rate of the transmission modulation method of the control station in the
AMR mode is temporarily managed.
The modulation method can be set according to the target device regardless of
the AMR Range setting.
Under the 1+0 configuration, each Slot#/Slot# is individually controlled.
This control is done by exchanging request/answer of the control between remote
stations.
When the TX Modulation Manual Control setting is returned from Manual to
Auto, the fixed modulation method is returned to QPSK.
Performing this function (Manual Control), the Maintenance Mode becomes On.
However, in case of Auto setting and if Maintenance Mode is set to Off it will cancel
the “auto setting”.
Procedure 7-14
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode ON.
NWD-142958-01E Maintenance
Control Items 7-49
Click.
5. The MODEM Maintenance Control box appears. Assign a proper value for
each parameter.
Maintenance NWD-142958-01E
7-50 Control Items
10. After finishing Radio Control, click Maintenance button on the top of the
LCT window to exit maintenance mode.
NWD-142958-01E Maintenance
Control Items 7-51
Procedure 7-15
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode ON.
Click.
5. The MODEM Maintenance Control box appears. Assign a proper value for
each parameter.
Maintenance NWD-142958-01E
7-52 Control Items
NWD-142958-01E Maintenance
Control Items 7-53
10. After finishing Radio Control, click Maintenance button on the top of the
LCT window to exit maintenance mode.
7.2.3.3 CW Control
Procedure 7-16
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode ON.
Maintenance NWD-142958-01E
7-54 Control Items
Click.
5. The MODEM Maintenance Control box appears. Assign a proper value for
each parameter.
NWD-142958-01E Maintenance
Control Items 7-55
Maintenance NWD-142958-01E
7-56 Control Items
10. After finishing CW Control, click Maintenance button on the top of the LCT
window to exit maintenance mode.
Procedure 7-17
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode ON.
NWD-142958-01E Maintenance
Control Items 7-57
Click.
5. The MODEM Maintenance Control box appears. Assign a proper value for
each parameter.
Maintenance NWD-142958-01E
7-58 Control Items
NWD-142958-01E Maintenance
Control Items 7-59
7.2.4 Inventory
Inventory will display the iPASOLINK, information of H/W, FW in mounted
MODEM, Network information and Software License Key information.
Procedure 7-18
Maintenance NWD-142958-01E
7-60 Control Items
NWD-142958-01E Maintenance
Control Items 7-61
Maintenance NWD-142958-01E
7-62 Control Items
5. It is available to save the Inventory Information if you click the Export IDU
Inventory Information button.
NWD-142958-01E Maintenance
Control Items 7-63
7. The Save As window appears. Select the proper folder of local PC and then
click Save button.
9. Confirm that the Inventory Information File was saved in the selected folder.
Maintenance NWD-142958-01E
7-64 Control Items
Procedure 7-19
NWD-142958-01E Maintenance
Control Items 7-65
5. It is available to save the Inventory Information if you click the Export ODU
Inventory Information button.
Maintenance NWD-142958-01E
7-66 Control Items
7. The Save As window appears. Select the proper folder of local PC and then
click Save button.
NWD-142958-01E Maintenance
Control Items 7-67
9. Confirm that the Inventory Information File was saved in the selected folder.
Procedure 7-20
2. Select the S/W License Information from the Inventory sub menu.
Maintenance NWD-142958-01E
7-68 Control Items
NWD-142958-01E Maintenance
Control Items 7-69
6. The Save As window appears. Select the proper folder of local PC and then
click Save button.
Maintenance NWD-142958-01E
7-70 Control Items
8. Confirm that the License Information file is saved in the selected folder.
NWD-142958-01E Maintenance
Control Items 7-71
- PMON/RMON/FDB Clear
Procedure 7-21
2. Select the MODEM PMON Report from the PMON / RMON Report sub
menu.
Maintenance NWD-142958-01E
7-72 Control Items
Click.
4. Click MODEM1.
5. The MODEM PMON Report (1-day) window appears. Confirm the detail of
MODEM PMON Report.
NWD-142958-01E Maintenance
Control Items 7-73
7. The MODEM PMON Report (15-min) window appears. Confirm the 15-min
Data (all data of 7 days) that saved in NE.
Export CSV File button
Maintenance NWD-142958-01E
7-74 Control Items
10. The Save As window appears. Select the proper folder of local PC and then
click Save button.
11. After finishing the export of CSV file, the Download Complete window
appears. Click Close button.
12. Confirm that the MODEM PMON Report File was saved in the selected folder.
NWD-142958-01E Maintenance
Control Items 7-75
Procedure 7-22
2. Select the ETH RMON Report from the PMON / RMON Report sub menu.
3. The ETH RMON Report window appears. Confirm the Remote Network
Monitoring value that monitored for 15-minute and 1-day will be displayed.
Click
Maintenance NWD-142958-01E
7-76 Control Items
5. The ETH RMON Report (1-day) window appears. Confirm the detail of
RMON Report.
Click
NWD-142958-01E Maintenance
Control Items 7-77
10. The Save As window appears. Select the proper folder of local PC and then
click Save button.
Maintenance NWD-142958-01E
7-78 Control Items
11. After finishing the export of CSV file, the Download Complete window
appears. Click Close button.
12. Confirm that the ETH RMON Report File was saved in the selected folder.
NWD-142958-01E Maintenance
Control Items 7-79
Procedure 7-23
2. Select the VLAN Counter Report from the PMON / RMON Report sub
menu.
3. The VLAN Counter Report window appears. Confirm the VLAN Counter
Report value that monitored for 15-minute and 1-day will be displayed.
Maintenance NWD-142958-01E
7-80 Control Items
Procedure 7-24
2. Select the PMON / RMON / FDB Clear from the Maintenance Control
sub menu.
3. The PMON / RMON / FDB Clear window appears. Select the PMON /
RMON Clear radio button and then click Execute button.
NWD-142958-01E Maintenance
Control Items 7-81
7. Select the each PMON or ETH RMON Report sub menu from the PMON /
RMON Report of the LCT menu.
Procedure 7-25
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode on.
3. Select the PMON / RMON / FDB Clear from the Maintenance Control
sub menu.
Maintenance NWD-142958-01E
7-82 Control Items
4. The PMON / RMON / FDB Clear window appears. Select the FDB Table
Clear radio button and then click Execute button.
5. The FDB Table Clear box appears. Select the All radio button and then
click OK button.
NWD-142958-01E Maintenance
Control Items 7-83
Procedure 7-26
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode on.
3. Select the PMON / RMON / FDB Clear from the Maintenance Control
sub menu.
4. The PMON / RMON / FDB Clear window appears. Select the FDB Table
Clear radio button and then click Execute button.
Maintenance NWD-142958-01E
7-84 Control Items
5. The FDB Table Clear box appears. Select the VLAN ID radio button and
input the VLAN ID No., and then click OK button.
NWD-142958-01E Maintenance
Control Items 7-85
Procedure 7-27
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode on.
3. Select the PMON / RMON / FDB Clear from the Maintenance Control
sub menu.
4. The PMON / RMON / FDB Clear window appears. Select the FDB Table
Clear radio button and then click Execute button.
5. The FDB Table Clear box appears. Select the Port radio button and select
card name and Port No. from each drop-down list, and then click OK button.
Maintenance NWD-142958-01E
7-86 Control Items
NWD-142958-01E Maintenance
Control Items 7-87
It can set up individually each ODU, the Sub Band which can be set up is according
to the alphabet "A-H, J-N, P and R, X".
Notes
1. Before changing the Sub Band setting, it is required to set TX Mute to ON,
and also prevent any rewriting data in the ODU Flash ROM.
2. In case of ODU which does not support a Sub Band change and from a
higher order Sub Band. If a change setup is carried out, an ODU
classification is judged and a Sub Band change setup is not performed.
Procedure 7-28
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode on.
Maintenance NWD-142958-01E
7-88 Control Items
5. The Offline Maintenance Control box appears. Select the RF Sub Band
Select drop-down list and click the OK button.
Parameter Description
A-H At the left is the Sub Band information setting
J-N (One Alphabet character)
P
R
X
NWD-142958-01E Maintenance
Control Items 7-89
8. The Offline Maintenance Control window appears again. Confirm that the
Status was modified as same as the selection in the DADE Adjust field.
9. After finishing RF Sub Band Select, click Maintenance button on the top of
the LCT window to exit maintenance mode.
Maintenance NWD-142958-01E
7-90 Control Items
Procedure 7-29
1. Click Maintenance button on the top of the LCT window to turn maintenance
mode on.
NWD-142958-01E Maintenance
Control Items 7-91
Maintenance NWD-142958-01E
7-92 Control Items
8. After finishing Maintenance Test, the LB (LT, DM, or LM) Result window
appears. Confirm the parameters displayed.
NWD-142958-01E Maintenance
Control Items 7-93
Click Export CSV File button on the top of the ETH OAM LB / LT / DM
/ LM Control window.
Click Export CSV File button in the LB (LT, DM, or LM) Result
window.
Maintenance NWD-142958-01E
7-94 Control Items
11. The Save As window appears. Select the proper folder of local PC and then
click Save button.
History Information:
HistoryInfoExport-YYYYMMDDhhmmss.csv
Test Result:
TestResultInfoExport-LB(LT, DM, or LM)-YYYYMMDDhhmmss.csv
12. After finishing the export of CSV file, the Download Complete window
appears. Click Close button.
NWD-142958-01E Maintenance
Control Items 7-95
13. Confirm that the CSV File was saved in the selected folder.
Maintenance NWD-142958-01E
7-96 Control Items
Procedure 7-30
2. Select the Import License key from the S/W License Setup sub menu.
NWD-142958-01E Maintenance
Control Items 7-97
3. The Import License key window appears. Click the Setup button.
Maintenance NWD-142958-01E
7-98 Control Items
4. The Import License Key window appears then click File icon button.
5. Select the license key(s) to be applied in the Dialog box for file selection where
license key is located.
NWD-142958-01E Maintenance
Control Items 7-99
Maintenance NWD-142958-01E
Trouble Shooting 8-1
8. TROUBLE SHOOTING
Maintenance NWD-142958-01E
8-2 Trouble Shooting
START
YES
Connect the LCT to the IDU and
Is ALM NO
check ALARM/STATUS menu.
indicator on the IDU
Check every items whether
solid red ?
indicated status is alarm or normal.
YES
Is ALM NO
indicator
The IF cable
on the MODEM Card Is TX Input NO
type, Cable length and
blinking red? indicated normal? cable loss are used
standard NO
YES YES
Check the IF cable YES
connection and connectors Replace the Change the
whether the cable is open or ODU with IF cable to
short circuit. Is TX power of NO
a spare. standard.
the ODU indicated
normal?
YES
Turn
Turnoffoffthe
the"ODU
IDU,PWR
and “
switch
turnonon theagain.
IDU, and
turn on again.
Is ODU
NO CPU/Cable Open ALM
indicated
normal?
YES
Reset CPU of the ODU.
YES YES
Is TX power NO
Is ODU
vary with ATPC manual
ALM indicated
control?
normal?
YES
YES
Replace the ODU END Check the RX Replace the ODU with Replace
with a spare. section of the ODU. a spare, if TX power alarm the ODU
continues when temperature with a spare.
is improved.
NWD-142958-01E Maintenance
Trouble Shooting 8-3
START
YES
Connect the LCT to the IDU and
Is ALM NO check Current Status menu.
indicator on the IDU Check every items whether
solid red ? indicated status is Alarm or Normal.
YES
NO
Is ALM
indicator
on the MODEM Card
blinking red ? NO
Is RX Level
indicated Normal?
YES
YES
Check the IF cable connection
and connectors whether the Is RX LEVEL by
cable is open or short circuit. RSL monitor vary ath random
NO interval?
YES
NO Check fading or
Is ODUCPU
/Cable Open ALM indicated interference.
Reset CPU of the ODU.
Normal?
YES
YES NO YES
Replace the END Check the TX Replace the Check Antenna system
Set proper
ODU section of the ODU or Replace the ODU
frequency.
with a spare. ODU. with a spare. with a spare.
Maintenance NWD-142958-01E
8-4 Trouble Shooting
START
NO Is PWR LED on
the IDU solid green?
YES
Replacethe
Replace Fuse
IDU
with a spare.
in the IDU Connect the LCT to the IDU
Is ALM and check Current Status
NO NO
indicator on the IDU menu. Check every items
solid red ? whether indicated status is
Alarm or Normal
YES
NO
Is ALM indicator
blinking red ?
YES
NO A
Is AIS Generated
indicated Normal?
Check associated
YES
DTE.
Check associated
DTE at local site. YES
NO Is CH Usage
indicated Normal ?
NWD-142958-01E Maintenance
Trouble Shooting 8-5
Is ODU indicated NO
Normal?
YES
Check the section
of the ODU.
NO Is Module ALM NO
Is IDU indicated
Normal? of Main Board Indicated
Normal?
YES YES
Replace the IDU
with a spare.
NO
Is Module ALM
of Option Card Indicated
Normal?
YES
Replace the Option Card
with a spare.
NO
Is RDI indicated
Normal?
YES
Check the opposite
Equipment.
Select IF Loopback from
MODEM Loopback Control menu in the
Maintenance Control menu on the LCT.
NO
Check the section
of the ODU.
Is Input LOS NO
indicated Normal?
YES
Check associated DTE
and cable connection.
Check associated DTE and cable
connection at opposite site.
Maintenance NWD-142958-01E
8-6 Trouble Shooting
Check the name plate of the spare ODU. When the indicated items are coincided, the
ODU can be replaced.
Caution:
1. Do not remove/connect the IF cable with the IDU power ON. Turn the IDU
power OFF before connecting/disconnecting the IF cable, or equipment
may be damaged.
7 6toto1111GHz
GHz to 42
13 to 42GHz
GHz
Caution: Be careful that the surface of the ODU is hot during operation.
The mounting and demounting the ODU from/to antenna, refer to Installation in
Section II.
NWD-142958-01E Maintenance
Trouble Shooting 8-7
Procedure 8-1
(1) Removing
5. Loosen the four bolts fixing the ODU with a T type hexagonal driver.
Maintenance NWD-142958-01E
8-8 Trouble Shooting
(2) Mounting
1. When the ODU is used for vertical polarization, rotate the ODU so that the
plate marked V is on the top.
2. When the ODU is used for horizontal polarization, remove the guide pin
fixed on the plate marked V.
3. Insert the guide pin removed in step 2 behind of the plate marked H.
NWD-142958-01E Maintenance
Trouble Shooting 8-9
Note:
1. Be careful not to damage the flange and O-ring.
2. Be careful to tighten the four screws alternately and gradually.
6. Mount the spare ODU onto the bracket and tighten the four screws on the
ODU.
Maintenance NWD-142958-01E
8-10 Trouble Shooting
NWD-142958-01E Maintenance
Trouble Shooting 8-11
8.2.2 DU Replacement
The procedures for replacing IDU with a spare are given in the Procedure 8-3.
Caution:
1. Persons performing maintenance must take necessary steps to avoid
electro-static discharge which may damage the cards or cause error. Wear
a conductive wrist strap connected to the grounded (G) jack on the front of
the equipment shelf. This will minimize static build-up during maintenance
(see Figure 2-1 in Chapter 2).
2. Do not remove/connect the IF cable with the IDU power ON. Turn the IDU
power OFF before connecting/disconnecting the IF cable, or equipment
may be damaged.
(a) Removing
Procedure 8-2
1. Disconnect power supply cable from power supply connector. Disconnect the IF
cable, signal cables and the power cable, etc. in the following order.
1-1. Disconnect LAN signal cables from connector.
1-2. Disconnect IF cable from IF IN/OUT connector.
1-3. Disconnect ground cable from the ground terminal.
2. When mounting on the rack, Loosen screws and remove the IDU from the rack.
Then, remove the mount bracket, if necessary to reuse for new IDU.
(b) Mounting
Procedure 8-3
Maintenance NWD-142958-01E
8-12 Trouble Shooting
2. Install the IDU to the original position. When using the rack, mount to the rack
and tighten screws.
3. Reconnect the IF cables, signal cables and the power cable to the original
position in the following order.
4. Form the wiring, and fix the cables using cable binder to the mounting rack.
Notes:
1. Do not cross the cables on front of indicators used for maintenance.
2. Take suitable radius to wiring the IF cable. (e.g. 5D-FB: 45 mm)
NWD-142958-01E Maintenance
Trouble Shooting 8-13
Procedure 8-4
Maintenance NWD-142958-01E
8-14 Trouble Shooting
Procedure 8-5
5. Retrieve the current alarms and check if the ODU alarm is cleared. If the
alarm is not cleared, contact NEC for the appropriate maintenance support.
8.3.4.2 TX Power
This message indicates that TX power level of the ODU is lower than 3 dB.
Procedure 8-6
8.3.4.3 TX Input
This message indicates that TX IF signal level is out of range from -29 dBm ± 5 dB.
Procedure 8-7
8.3.4.4 RX Level
This message indicates that RX level is lower than -72dBm ~ -94dBm level (Alarm
detection level depends on modulation schemes and bit rates).
Procedure 8-8
NWD-142958-01E Maintenance
Trouble Shooting 8-15
Procedure 8-9
Procedure 8-10
1. Exchange the ODU with correct type or set correct modulation setting.
This step is the end of the procedure.
Procedure 8-11
Procedure 8-12
Maintenance NWD-142958-01E
8-16 Trouble Shooting
3. If the alarm is not cleared, contact NEC for the appropriate maintenance
support.
Procedure 8-13
3. Retrieve the current alarms, and check if the CLK FAIL alarm is cleared.
4. If the CLK FAIL alarm is detected yet, check whether any alarm of the
indicated port/line is cleared.
6. Retrieve the current alarms, and check if the CLK FAIL alarm is cleared. If
the alarm is not cleared, contact NEC for the appropriate maintenance
support.
Procedure 8-14
3. Retrieve the current alarms, and check if the CLK Drift alarm is cleared.
NWD-142958-01E Maintenance
Trouble Shooting 8-17
4. If the CLK Drift alarm is detected yet, check whether any alarm of the
indicated port/line is cleared.
6. Retrieve the current alarms, and check if the CLK Drift alarm is cleared. If
the alarm is not cleared, contact NEC for the appropriate maintenance
support.
8.3.5.4 LTI
This message indicates that the IDU does not synchronize with any reference clock
source. If this condition occurs, the problem is on the optical fiber/electrical cable or on
the far-end NE.
Procedure 8-15
3. Retrieve the current alarms, and check if the LTI alarm is cleared. If the
alarm is not cleared, contact NEC for the appropriate maintenance support.
This message indicates that received sync status message value is in unstable
condition. If this condition occurs, the problem is on the input cable or on the
external timing source.
Procedure 8-16
3. Retrieve the current alarms, and check if the alarm is cleared. If the alarm is
not cleared, contact NEC for the appropriate maintenance support.
Maintenance NWD-142958-01E
8-18 Trouble Shooting
This message indicates that a failure of the ETH LOS (Loss Of Signal) is detected
from the incoming signal on the indicated facility. If this condition occurs, the
problem is on the optical fiber or on the far-end NE.
Procedure 8-17
3. Retrieve the current alarms, and check if the LOS alarm is cleared. If the
alarm is not cleared, contact NEC for the appropriate maintenance support.
8.3.5.7 ETH TF
This message indicates that a failure has been detected in the installed SFP modules.
The possible cause is SFP module failure.
Procedure 8-18
2. Retrieve the current alarms, and check if the TF alarm is cleared. If the alarm
is not cleared, contact NEC for the appropriate maintenance support.
This message indicates that a failure has been detected in the port. The possible cause
is SFP type error or the port configuration error in the LCT.
Procedure 8-19
1. For the Ethernet port and STM-1 port, confirm their port configurations in
the LCT.
3. Retrieve the current alarms, and check if the SFP Type Mismatch alarm is
cleared.
NWD-142958-01E Maintenance
Trouble Shooting 8-19
4. If the SFP Type Mismatch alarm is detected yet, check whether the SFP type
of these ports is correct.
6. Retrieve the current alarms, and check if the SFP Type Mismatch alarm is
cleared. If the alarm is not cleared, contact NEC for the appropriate
maintenance support.
7. For other ports, check whether the SFP type of these ports is correct first.
8. If not, remove the SFP module, and insert the correct SFP module to
specified port.
9. Retrieve the current alarms, and check if the SFP Type Mismatch alarm is
cleared. If the alarm is not cleared, contact NEC for the appropriate
maintenance support.
This message indicates that a failure has been detected in the registered port. The
possible cause is removed of the SFP module.
Procedure 8-20
1. Pull out the SFP module, and reinsert it into the port.
2. Retrieve the current alarms, and check if the SFP Unequipped alarm is
cleared.
3. If the SFP Unequipped alarm is detected yet, confirm that the SFP module is
located in the specified port, if not, move it to the right port.
4. Retrieve the current alarms, and check if the SFP Unequipped alarm is
cleared.
6. Retrieve the current alarms, and check if the SFP Unequipped alarm is
cleared. If the alarm is not cleared, contact NEC for the appropriate
maintenance support.
Maintenance NWD-142958-01E
8-20 Trouble Shooting
This message indicates that a failure of Ethernet Link down is detected on the
indicated port. If this condition occurs, the problem is on the optical fiber or on the
far-end NE.
Procedure 8-21
3. Retrieve the current alarms, and check if the LAN LINK alarm is cleared. If
the alarm is not cleared, contact NEC for the appropriate maintenance
support.
Procedure 8-22
2. Retrieve the current alarms, and check if the ETH-OAM LOC alarm is
cleared.
5. Retrieve the current alarms, and check if the ETH-OAM LOC alarm is
cleared.
6. If the ETH-OAM LOC alarm is detected yet, check whether the MEG/MEP
configuration on the far-end NE is correct.
8. Retrieve the current alarms, and check if the ETH-OAM LOC alarm is
cleared. If the alarm is not cleared, contact NEC for the appropriate
NWD-142958-01E Maintenance
Trouble Shooting 8-21
maintenance support.
This message indicates that a failure of Mismerge is detected on the indicated MEP.
The possible cause is the unexpected ETH-CC frames received from far-end NE or
the MEG/MEP configuration error in the LCT.
Procedure 8-23
3. Retrieve the current alarms, and check if the ETH-OAM Mismerge alarm is
cleared.
6. Retrieve the current alarms, and check if the ETH-OAM Mismerge alarm is
cleared. If the alarm is not cleared, contact NEC for the appropriate
maintenance support.
This message indicates that a mismatch of the ETH-CC transmit period is detected
on the indicated MEG. The possible cause is the mismatch of the MEG configuration
between the far-end NE and local NE in the LCT.
Procedure 8-24
3. Retrieve the current alarms, and check if the ETH-OAM Unexpected Period
alarm is cleared.
Maintenance NWD-142958-01E
8-22 Trouble Shooting
6. Retrieve the current alarms, and check if the ETH-OAM Unexpected Period
alarm is cleared. If the alarm is not cleared, contact NEC for the appropriate
maintenance support.
This message indicates that a failure of the ETH-OAM RDI (Remote Defect
Indicate) is detected from the incoming ETH-CC frame on the indicated MEP. If this
condition occurs, the problem is an alarm detected at the peer MEP.
Procedure 8-25
2. Clear conditions that cause the alarm in the MEG that belongs to a peer
MEP.
3. Retrieve the current alarms, and check if the ETH-OAM RDI alarm is
cleared. If the alarm is not cleared, contact NEC for the appropriate
maintenance support.
8.3.5.15 Temperature
This message indicates that the temperature in the IDU is over the workable temperature.
This possible cause is that the room temperature is uncontrolled.
Procedure 8-26
1. Check if there is any problem in the air conditioner on the IDU room.
3. Retrieve the current alarms, and check if the Temperature alarm is cleared.
If the alarm is not cleared, contact NEC for the appropriate maintenance
support.
4. (Wait 1 hour at least after the room temperature is fallen down under the
workable temperature.)
NWD-142958-01E Maintenance
Trouble Shooting 8-23
This message indicates that mismatch exists between IDU configuration and installed
software license key. The possible cause is removal of the software license key from
the IDU by the software key allocator system.
Procedure 8-27
8.3.6.1 LOF
Procedure 8-28
8.3.6.2 Frame ID
Procedure 8-29
Maintenance NWD-142958-01E
8-24 Trouble Shooting
This message indicates “Radio signal degradation (High BER threshold detection)”.
Procedure 8-30
3. If the RX LEV metering value is correct, replace the IDU with a spare.
This message indicates “Radio signal degradation (Low BER threshold detection)”.
Procedure 8-31
2. If the RX LEV metering value is correct, replace the IDU with a spare.
Procedure 8-32
2. If the RX LEV metering value is correct, replace the IDU with a spare.
NWD-142958-01E Maintenance
Trouble Shooting 8-25
This message indicates “IF cable between IDU - ODU is in short condition”.
Procedure 8-33
3. If IF CABLE SHORT alarm is not cleared, replace the IDU with a spare.
MODEM port”.
Procedure 8-34
2. If the RX LEV metering value is correct, replace the IDU with a spare.
8.3.6.8 RDI
Procedure 8-35
3. Retrieve the current alarms, and check if the RDI alarm is cleared. If the
alarm is not cleared, contact NEC for the appropriate maintenance support.
Maintenance NWD-142958-01E
8-26 Trouble Shooting
8.3.6.9 UAE
Procedure 8-36
1. Check the current alarms, and if there are any other alarms, clear these
alarms at first according to the troubleshooting.
2. After clearing every alarm, retrieve the current alarm, and check if the UAE
is not cleared with any alarms, contact NEC for the appropriate maintenance
support.
Procedure 8-37
1. Set same AMR configuration as remote NE. Refer to operation manual for
detail.
8.3.6.11 Unlocked
Procedure 8-38
1. Check the equipment clock setting. Refer to operation manual for detail.
NWD-142958-01E Maintenance
Trouble Shooting 8-27
This message indicates that all of member ports belonged to the ETH Link
Aggregation group are down.
Procedure 8-39
This message indicates that Link OAM keep alive protocol timeout is detected. The
possible cause is in the opposite NE via Ethernet link, equipment configuration of
link OAM or failure.
Procedure 8-40
3. Retrieve the current alarms, and check if the Link OAM Down alarm is
cleared. If the alarm is not cleared, contact NEC for the appropriate
maintenance support.
This message indicates that the opposite NE via Ethernet link detects Ethernet link
fault in the receive side.
Maintenance NWD-142958-01E
8-28 Trouble Shooting
Procedure 8-41
3. Retrieve the current alarms, and check if the Remote Link Fault alarm is
cleared. If the alarm is not cleared, contact NEC for the appropriate
maintenance support.
This message indicates that the opposite NE via Ethernet link is under reboot
condition.
Procedure 8-42
3. Retrieve the current alarms, and check if the Remote Dying Gasp alarm is
cleared. If the alarm is not cleared, contact NEC for the appropriate
maintenance support.
This message indicates that a failure of hardware is detected in the opposite NE via
Ethernet link.
Procedure 8-43
2. Retrieve the current alarms and check if the Remote Critical Event alarm is
cleared. If the alarm is not cleared, contact NEC for the appropriate
maintenance support.
NWD-142958-01E Maintenance