Introduction
HyperWorks Desktop13.0.114_hotfix contains enhancements and bug fixes for HyperMesh,
HyperGraph, HyperView, MotionView, HyperCrash and NVH (Packaged Solution Offering). The details
are documented below.
Note: HyperWorks Desktop13.0.114_hotfix is a cumulative release. It should be installed on top of
HW 13.0.110 and includes HyperWorks Desktop13.0.113_hotfix.

HyperMesh
New Features and Enhancements
Connectors
 A new option has been added to the spot connectors. It uses normal direction of the closest link
to determine links. In certain situations with many small component patches like rib patterns,
wrong links were identified. With this option activated, the link determination follows a search
direction.
 For certain CWELD types the option “centered quad” has been added. If activated, a centered
quad is created on both sides of the CWELD around the projection points. The mesh is very
locally remeshed to satisfy this request. The quad size can precisely be defined.

HyperGraph
Resolved Issues
 In polar plots, the phase angle will no longer change when the reference value for magnitude is
unequal to 1 for dB-scaled curves.
 When different start- and end- index values are used in the same session, using the BuildPlots
panel to trim the curves during import of the curves could have been empty.

LS-Dyna Interface
Resolved Issues
 An application error occurred after import if the include file skip option was used and include file
of type TRANSFORM was present in the model
 In material type *MAT_GENERAL_SPRING_DISCRETE_BEAM a random number was added in
the GLCID field during import if the field was blank
 Deleting a cross section while in review mode lead to a crash

Nastran Interface
Resolved Issues
 File read issue with ANSA comments related to color and name
HyperWorks Desktop 13.0.114 Release Notes 1
 Import error related to BCPROP

Abaqus Interface
Resolved Issue
 Export error with *Beam Section property without HyperBeam section is fixed

MotionView
Resolved Issue
 Create Deformable Surface macro could not create closed surfaces.

HyperCrash
Resolved Issues
 The application crashed when deleting a both bolt connector if some rigid body were defined by
BOX in the model
 The application crashed if surfaces were referring to unresolved BOX
 XY data of curves could not be parametrized anymore
 Triangular elements were displayed as solid elements after merge operation if certain actions
were performed prior to merge: isolating a property with triangular elements or using advanced
review in the part replace report.
 The number of integration point were not exported for initial stress and initial plastic strain in
RADIOSS V13 user profile

NVH Packaged Solution Offering


New Enhancements
 Analysis Manager
o Reorganization of the GUI for editing Analysis items and Analysis Solution Definition
o Performance improvement in Analysis Manager in invoke, edit and apply
o Implementation of scroll bar in Analysis Manager for easy visualization of Analysis and
Solution definition
o Support of solver deck in Analysis Manager for Frequency Response Analysis
o Enhancement for auto recognition of PANELs for Grid and Panel Participation Requests
o Form of output request is ‘Phase’
o Enhancement in Modal Participation request to define system and component modal
participation
o Support for CMS and Modal Energy output request
o Implementation of Active Analysis Definition while saving and launching of Analysis
Manager
o Addition of Debug Section in Analysis Manager to define Debug parameters
o Support of subcase name in loading strength UI of Analysis Manager to allow spindle
loads definition in TPL file
 Batch Model Reduction
o Enhancement of GUI for visualization and review of modal parameters: number of grids,
number of modes, first frequency and last frequency
o Enhancement in the name of input solver deck generated from batch model reduction
with rep file name integrated into module name

HyperWorks Desktop 13.0.114 Release Notes 2


o Enhanced Batch Model Reduction SE organization with option to specify location for
saving the SE-result file before assigning it as module representation
o Automatic assignment of DMIGDV files
o Support of States (MPCs and SPCs) in batch model reduction
o Enhancement in batch model reduction in case of separate master and display rep files
for modules
 Batch Module Prepare
o Enhancement in handling detailed FE rep and display model rep in case display model is
exported into a separate file after batch prepare
o Option for damping validation
o Selector to auto select modules with assigned IDs but not validated
 Manual Module Prepare
o Enhancement to prepare and save detailed FE model and display model in case of
separate master and display rep files for modules
o Enhancement in damping tab with list of materials for damping review and assignment
 Connection Realization
o Enhancement in exporting owned LCS definition of connection in template CSV file
o Connection realization variations
 Single PBUSH
 RBE2-Coincident PBUSH-RBE2 (new enhancement)
 Single RBE2 (new enhancement)
 RBE2-Coincident RBE2 – RBE2
o Enhancement related to reconciliation of connection force ID and connector id saved in
xml file
o Support of connection name matching in connection mapping tool
 Network View
o Enhancement for export / import of Network View definition in template CSV file
o Option to reset all connection size to the select one
o Option to switch on/off module ID ranges

 Modal Assurance Criteria


o Enhancement in handling complex modal data
 Energy Distribution Analysis
o Support of NX-Nastran results in OP2 format
o Enhancement related to highlighting of selected contributors from display options in
graphics area
Resolved Issues
 Issue related to SPOINT component definition created for grounding of modal models
 Issue in going back to Assembly Browser on closing Edit Module window, incase connection
browser is opened after assembly browser
 Issue in connections related to node dependency and location after batch prepare
 Issue related to sorting of template list for loading point selection in a Frequency Response
solution type
 Issue in loading TPA configuration file
 Issues related to import / export of node mapping pairs in Modal Assurance Criteria
 Issue related to application error in Batch Prepare While Trying to Save a Write Protected
File/Folder
 Issues related to resizing of GUIs in Linux before vital buttons are seen
 Issues in Analysis Manager with large models (Volvo, JLR, etc)
o Black Strips on launching analysis manager
o Resize of analysis manager GUI on launch
 Issues related to incorrect warning message for re-position node when picking nodes to define
tagpoints
 Issue related to updating Connection switch Nodes Status
 Application error while trying to create Constraints in Prepare Module mode
 Application error in Analysis Manager while skipping modules

HyperWorks Desktop 13.0.114 Release Notes 3


HyperWorks Desktop
13.0.113 Release Notes

Introduction
HyperWorks Desktop13.0.113_hotfix contains enhancements and bug fixes for HyperMesh,
HyperGraph, HyperView, MediaView, Model Identification Tool and NVH (Packaged Solution Offering).
The details are documented below.
Note: HyperWorks Desktop13.0.113_hotfix is a cumulative release. It should be installed on top of
HW 13.0.110 and includes HyperWorks Desktop13.0.112_hotfix.

HyperMesh
New Features and Enhancements
General
 Within the browser include view, a new include file export option to control comments is
available.
CAD
 CATIA v5-6R2015 (R25)
 PTC Creo 2.0 M140 and 3.0 M030
 SolidWorks 2015 on Windows and Linux (2014 on MAC)
o There is a known third-party library issue where reading certain SolidWorks 2015 files
may crash the application. Please exhibit caution and save your work before reading
any SolidWorks 2015 files.

Resolved Issues
General
 Crash related to binary file save for models containing incorrect hierarchy.
CAD
 Resolved a JT reader issue where certain solid geometries were not editable after import into
HM.
Connectors
 Absorption of hexa seam and area connectors in conjunction with the usage of the “consider
single element cluster” option have been improved.
 The feature angle is no longer updated to 46 degrees after certain solid absorptions occur.
 The seam and area hexa adhesive realization types for OptiStruct and Nastran will no longer
generate RBE2 elements, only RBE3 elements, in the case of a direct projection.

Graphics
 Application was crashing while reflecting rigid elements.
 “By Face” selection for large number of elements is showing performance issues.
 Application crashes while using “By Face” selection after masking elements.
 Improved show/hide performance for groups.
HyperWorks Desktop 13.0.114 Release Notes 4
HyperView
New Feature and Enhancement
 Support of PamCrash 2014

Resolved Issues
 HyperView 3Dconnexion support while animating on Windows has been fixed.
 Display of element marks under Preferences->Options ->Visualization was not working.
 View synchronization of windows was not working properly for certain models.
 Application crash when viewing stress results on a frequency response model with complex
corner data.
 Unexpected hang of HV when model file or h3d contains assembly information with circular
referencing (e.g. Assembly 1 is both parent and child of Assembly2).
 Issue with HyperView running separate concurrent sessions on a multiple GPU system under a
Linux system was fixed. This also resolves issues with Display Manager running HyperView with
multiple concurrent sessions.

HyperGraph
Resolved Issues
 In complex plots the conversion from real/imaginary to phase/magnitude for db-scaled complex
curves with a reference value will calculate the correct magnitude.
 Notes attached to dB-scaled complex curves no longer disappear at the moment a reference
value is assigned to the dB-scaling.
 Notes which are attached to a dB-scaled phase/magnitude complex curve with a reference value
now show the corresponding y-axis value when the expression {y} is used and no longer the
unscaled source value.
 Notes attached to the magnitude of complex curves will keep their attachment point when a
session is saved and reloaded.
 Complex curves based on math references for dB-scaled curves with a reference value were
scaled twice in previous builds. This issue is fixed.
 In the Build Plots panel, the pop-up window for X-requests now supports the same filter
features as for Y-requests.
 Performance for reader metadata support, which is required to use the Comparison and/or
Highlight Source Entity tools has been improved for files which contain millions of
curves. Specifically:
o For files with less than 300,000 metadata sets, we read the metadata in by default
o For files with more than 300,000 metadata sets we do not read metadata.
o If the user wants to read the metadata for files with more than 300,000 metadata sets,
or skip the reading totally the limit can be adjusted by setting an environment variable
HG_METADATA_LIMIT = <limit number of metadata sets>. There will be a performance
penalty if this setting is utilized with a higher limit.
o For HyperGraph 14.0 we intend to make this environment variable obsolete.
 In 13.0, when saving a template after reading a Dyna file that had labels for IDs, both the label
and ID information would be saved in the template file. This caused overlay issues, since the
template tried to match both Label and ID. The behavior has been reverted back to the pre-
13.0 behavior, wherein only the Label information, and not the actual ID, is saved in the
template. The ID now gets added as an attribute of the curve as metadata.

HyperWorks Desktop 13.0.114 Release Notes 5


o If the user wants to load a session/report created with the 13.0 default setting into
13.0.113 he has either set the environment variable DYNA_REQUEST_TYPE to NAME_ID
or delete the ID’s manually out of the requests in the session/report file.

LS-Dyna Interface
Resolved Issue
 Include files with long names are now written out in master file during export.
 Problem reading multiple d3eigv files

RADIOSS Interface
Resolved Issue
 Application crashed during export if the model contained corrupted array.

PamCrash Interface
New Feature and Enhancement
 Support of PamCrash 2014.

OptiStruct Interface
New Features and Enhancements
 Added AMSES Amplification Factor support in CMSMETH card.
 Create Contacts by Property is available, user can now assign BCPROP to BCBODY.
 Added support of output request for component modal synthesis & modal energy outputs.

Nastran Interface
Resolved Issues
 Include files with long names are now written out in master file during export.
 Application error related to an Include export from include browser view.
 Include files with unsupported cards are now organized to respective includes.

Abaqus Interface
Resolved Issues
 For Nastran to Abaqus conversion, if PbeamL, Pbeam, Pbar or Pbarl has a hyperbeam section
assigned, during conversion the relation is lost. The relation maintained during conversion.
 Duplicate property in different include leads to component property lose during import. This has
been fixed.
 Performance of Nastran to Abaqus conversion has been improved.

HyperWorks Desktop 13.0.114 Release Notes 6


Samcef Interface
New Features and Enhancements
 Users can define real number to define the time step of a non-linear analysis.
 Between the initial and the final time step, intermediate times could be defined.

MediaView
Resolved Issue
 If a video contains negative time values the correct time is now displayed in the Animation
Control Panel and not Undeformed or Undefined.

HyperCrash
New Features and Enhancements

 Provided the ability to convert parallelogram cross section (/SECT/PARAL) to circular cross
section (/SECT/CIRCLE) through the change subtype functionality in the section panel.
 Updated property type 8, 13 and 25 as per Radioss V12.0.210.
 Updated sensor of type interface (/SENSOR/INTER) as per Radioss V12.0.210.

Resolved Issues
 Connection extraction was failing when some of the connections needed to be unrealized after
extraction process.
 Rigid bodies defined with cylindrical or spherical box were corrupted in replace, export selection
or update operation.
 /DAMP and /DAMP/INTER were not correctly implemented as per the Radioss V12.0.210
manual.
 Rigid body with master node defined on an element and with Icog=3 or 4 were incorrectly
reported as error.
 Switching on detailed mode slowed down the application when many circular beam
property/section were defined in the model.
 Updating adhesive, welding lines and other continuous connection defined on more than 2
layers was not possible.

NVH Packaged Solution Offering


New Features and Enhancements
 Support of RPM based forces in Transfer Path Analysis Utility
 Enhancement in the connection realization logic in Analysis Manager for realized connections
with no change in State or Property

Resolved Issues
 XML import performance issue related to Job Manager GUI
 Issue related to handling of damping modification in ascii file generated for CMS-SE
 Issue related to template change in the existing Analysis definition. The value from the old
template are not cleared and shown even after loading the new template
 Issue related to incompatible display representation getting when using alternative master
representation
HyperWorks Desktop 13.0.114 Release Notes 7
 Issue in MAC utility in handling complex data

Model Identification Tool


New Features and Enhancements
 Support umlaut characters in spd file
This release includes support for umlaut characters in spd file. MIT now can read the files with
umlaut characters and can be used in fitting.

 Documentation enhancements
With this release, we have enhanced our documentation with better explanation. The
enhancements are as follows.
1. The description of the models in the help is improved. Provided better explanation for all
the rubber and hydro bushing parameters.
2. Documented fitting process. Added documentation for static curves, friction parameters.
3. Added documentation for calculating dynamic stiffness and loss angle. Explained Analyze
process in details and its purpose.
4. Included explanation for how static stiffness derived from stiffness curve.

 Matplotlib live fitting monitor enhnacements.


Added intuitive text boxes for live fitting monitor and gives user an idea of what is happening in
the fitting process for every step.

 MIT batch mode using python scripts.


MIT batch mode supported using python scripts in windows and Linux.

Resolved issues

 Analyze and Fitting results mismatch.


There was a mismatch with fitted results and analyse results. This is fixed in this release.

 Erros while analysing the bushing


Tk errors while analysing the hydro mount bushing is fixed in this release.

 MIT help doesn't come up even after clicking "Help" button in MIT dialog
Invoking help from MIT gui has an issue and it is fixed.

 MIT decode report is not working in linux


Creating pdf report from GBS file is not working in Linux and it is fixed.

 Improved initial guess values of GBS and OPT files


Input gbs and opt files are modified with better initial guess values for global optimisation.

 Hydromount fit does not use OPT


Fixed an issue with fitting code which is not using user provided opt file.

 Rotational Z direction Models ignore user GBS/OPT


Fixed an issue with fitting code which is not using user provided gbs and opt files for TZ
direction.

 Flex disk models units display in HG is not correct at the vertical axis
Fixed an issue with units for rotational direction bushing test files, those are showing mm
instead of degrees.

 Equations for rubber bushing and hydromount bushnigs in GUI are incorrect
Modified the images for rubber and hydro mount bushings in MIT gui.

HyperWorks Desktop 13.0.114 Release Notes 8


 The algorithm we use to derive the cubic polynomial from the static stiffness data can cause
parts of the cubic to have negative stiffness.
Now we are prompting with a warning message at the time of loading spd file.

 Rotational direction plots are displaying units as m instead of degrees.


This issue if fixed with proper units display while plotting the test data in HG.

 Parameter EPSILON in GBS is unused and needs to be removed.


Now the epsilon is not writing out in GBS file. GBS reader and writer has been modified to fix
this issue and all the input files are changed accordingly.

 Parameters in different order in GBS and OPT files.


Now parameters are in same order across the input and output files of MIT code.

 Input SPD to MIT and Input SPD to FIT tool do not match.
Now input and output spd files are in the same order. spd writer code change has fixed this
issue.

 Input SPD to MIT and Input SPD to FIT tool do not match.
Now input and output spd files are in the same order. spd writer code change has fixed this
issue.
 The algorithm we use to derive the cubic polynomial from the static stiffness data can cause
parts of the cubic to have negative stiffness. Now we warn the user while loading the test data
in to MIT tool.

HyperWorks Desktop 13.0.114 Release Notes 9


HyperWorks Desktop
13.0.112 Release Notes

Introduction
HyperWorks Desktop13.0.112_hotfix contains enhancements and bug fixes for HyperMesh,
HyperGraph, HyperCrash and NVH (Packaged Solution Offering). The details are documented below.
Note: HyperWorks Desktop13.0.112_hotfix is a cumulative release. It should be installed on top of
HW 13.0.110.

HyperMesh
New Features and Enhancements
CAD
 Support of NX 10.0 (native reader)

Resolved Issues
General
 Resolved an issue where reading .hm files would reverse the order of geometric entities in the
databaseNew component creation with in Assembly hierarchy
 Node picking while doing a quick model rotation has been resolved
 Updates to the 3Dconnexion spacemouse support for HyperMesh has been updated with the
following changes/fixes:
1. The rotation speed handling has been updated to work directly through the driver
settings
2. Consistency in the way both products handle similar sized models
3. 3Dconnexion driver button mapping support updated for HyperMesh
4. Supporting newer wireless spacemouse devices from 3Dconnexion
NOTE: Minimum driver requirement is 3DxWare 10.2.3.

HyperView
Resolved Issues
General
 Updates to the 3Dconnexion spacemouse support for HyperView has been updated with the
following changes/fixes:
1. The rotation speed handling has been updated to work directly through the driver
settings
2. Consistency in the way both products handle similar sized models
3. 3Dconnexion driver button mapping support updated for HyperView
4. Supporting newer wireless spacemouse devices from 3Dconnexion
NOTE: Minimum driver requirement is 3DxWare 10.2.3.

HyperWorks Desktop 13.0.114 Release Notes 10


HyperGraph
Resolved Issues
 The mismatch of types and requests in Dyna binout file for abstat_cpm airbag results has been
fixed.
 Even when the “Autofit Plot” option in the Flexible Report panel was switched off all plots
besides the first plot on the first page where auto-fitted. Now the option works as expected.
 When fit was performed in 13.0.110 on a plot either during curve import or via the 2D View
Controls for some curves the axis min and max values were exactly like curve end points values
and not nicely rounded. This hotfix brings back the 13.0 behavior.

LS-Dyna Interface
Resolved Issue
 An issue in the Dyna reader prevented HyperMesh from reading includes if the path was defined
with back slash (\).

HyperCrash
Resolved Issue
 All the curves referenced in a material law or property could be lost if those curves were
reviewed before saving the modification.

NVH Packaged Solution Offering


Resolved Issue
 Fixed a regression issue in NVH network view functionality in 13.0.111, where tagpoint symbols
and owning module arrows are not showing, and module and connection information is not
displayed in the message window when hovering with mouse

HyperWorks Desktop 13.0.114 Release Notes 11


HyperWorks Desktop
13.0.111 Release Notes

Introduction
HyperWorks Desktop13.0.111_hotfix contains enhancements and bug fixes for HyperMesh, HyperView,
HyperGraph, HyperCrash and NVH (Packaged Solution Offering). The details are documented below.
Note: HyperWorks Desktop13.0.111_hotfix is a cumulative release. It should be installed on top of
HW 13.0.110.

HyperMesh
New Features and Enhancements
CAD

 Enhanced the IGES @PropertyAsGroup option to additionally support files coming from ANSA
14.X and later
 Added JT support to the cadassm utility

Connectors
 New realization method “hexa (tapered T)” is added for Ls-Dyna user profile

Resolved Issues

CAD

 Resolved a problem where certain degenerate surfaces were being written to IGES files
 Improved the reliability of NX metadata import for surface edges under certain conditions where
metadata was previously being lost

General

 New component creation with in Assembly hierarchy


 Resolved a performance issue when deleting surfaces with the “delete associated solids” option
enabled
 Resolved an application error with the FBD Export Manager when exporting FBD Displacement
or Resultant Force and Moment results
 Resolved crashes with the *createentity, *createentitysameas and *setvalue commands when
an invalid syntax is used
 Resolved crashes when the -nomenuset option was used at HM startup

Meshing

 Resolved multiple issues in the quality index panel that could potentially lead to crashes. These
crashes often showed up after performing editing operations in the quality index panel, and
then performing element remeshing in the automesh panel.
 The quality index panel node and element optimize operations have been fixed to honor
component boundaries
 Resolved a crash when performing solid map operations on second order elements

HyperWorks Desktop 13.0.114 Release Notes 12


 Resolved a performance issue that would occasionally appear to hang the application when
performing element-based re-meshing when geometry was present

NVH

 Fixed an issue with the “MPC Creation Between Cavities” tool (*acm_mpc_create API) where
patched holes were not properly being considered

HyperView
New Features and Enhancements

 The text CornerData will be displayed in the legend title if the result plot is generated using
such data. Previous versions of HV did not provide this information in the legend.

 Video Overlay Enhancements:

Significant improvements have been made to the video overlay (Image Planes) functionality in this
release of HyperView. It is now possible to achieve a good overlay of Model and Video/Image by a
multiple point alignment scheme or by providing the properties of the camera that was used to
capture the image.

The multi-point alignment method has been added as a new tab under the 2D Image Plane section
and it works by allowing the user to pick points (pairs of pixels in the image and corresponding
nodes in the model). A minimum of seven points are required as input. It is also recommended that
points are picked at different depths and preferably towards the center of the image/video. The GUI
will show a dynamically updating error value to indicate to the user the quality of the selected
points. HyperView will then use the points to adjust the model size and orient it in the appropriate
view so that a good alignment is achieved between the model and the image/video.

In addition to the multi-point alignment method, one can also now input the camera position and
camera properties such as focal length, sensor height, if it is available, through the views entity in
the browser. This provides a more direct way of achieving alignment between model and image. A
new projection type under views called Lens has been added for this purpose.

Resolved Issue
 Last load case missing in H3D containing envelope of all load cases.

HyperGraph
Resolved Issue
 For some ISO files, units for acceleration was picked up as m/sec2 when the units were in g’s.
This has been fixed now.

OptiStruct Interface
Resolved Issue
 Regular and Formula sets are now retained as is during import and export
 Abaqus to OptiStruct conversion issue related to OptiStruct CBUSH local system assignment
when converting CONN3D elements from Abaqus.

HyperWorks Desktop 13.0.114 Release Notes 13


Nastran Interface
Resolved Issue
 Sequential export of CQUAD elements

LS-Dyna Interface
New Enhancements
The cross section entity is newly introduced in 13.0.111. The following keywords are mapped to this
entity: *DATABASE_CROSS_SECTION_SET; *DATABASE_CROSS_SECTION_PLANE. These keywords
were supported prior to 13.0.111 but were mapped to a different entity (Group). Upon import the
following behavior is implemented:

 Solver deck: these keywords will be automatically mapped to the new entity without loss
 Legacy HyperMesh file: these keywords will be mapped from the old to the new entity without
loss
Note: As this entity is newly introduced in 13.0.111, a HyperMesh file saved in 13.0.111 cannot be read back in
prior versions without loss. The keywords mapped to these new entity will be lost. To reduce the risk of data loss it
is recommended to:

 Uninstall prior 13.0 versions after installing this hotfix


 Export the solver deck if data needs to be exchanged between 13.0.111 and prior versions

 Full support of *DEFINE_BOX_LOCAL


 New entity for *DATABASE_CROSS_SECTION:
o Resolved ID renumbering upon import that occurred if a cross section shared the same
ID as a contact for example.
o Offset defined in *INCLUDE_TRANSFORM is now taken into account
o Enhanced graphical representation and review for cross sections
 Improved performance and accuracy of the tied contact status check (nodes tied / untied from
model checker)
 In the find attached subpanel a checkbox allows to take into account tied contacts in the search
for connected elements
 I/O support of encryption for *DEFINE_CURVE

Resolved Issues
 *DEFINE_TABLE is not be listed in the curve editor anymore
 The transformation applied through *NODE_TRANSFORM were not applied in the correct
sequence

RADIOSS Interface
New Enhancements
Two entities are newly introduced: CrossSection and Box. The following keywords are mapped to
these entities:
 CrossSection: /SECT; /SECT/CIRCLE; /SECT/PARAL
 Box: /BOX/RECTA (RADIOSS)
Some of the keywords listed above were already supported prior to 13.0.111 but were mapped to a
different entity. Upon import the following behavior is implemented:

 Solver deck: these keywords will be automatically mapped to the new entity without loss
HyperWorks Desktop 13.0.114 Release Notes 14
 Legacy HyperMesh file: these keywords will be mapped from the old to the new entity without
loss
Note: As these entities are newly introduced in 13.0.111, a HyperMesh file saved in 13.0.111 cannot be read back
in prior versions without loss. The keywords mapped to these new entity will be lost. To reduce the risk of data
loss it is recommended to:

 Uninstall prior 13.0 versions after installing this hotfix


 Export the solver deck if data needs to be exchanged between 13.0.111 and prior versions

 User scripts pointing to the old entity for /SECT can be updated to create the new CrossSection
entity by adding the following lines are the end of the script:
set path [hm_info -appinfo SPECIFIEDPATH
hm_scripts_dir]//radioss//sections//ConvertOldSectionKeywordsToNewCrosssectionKeywords.tcl
source $path;
 Full support of /BOX/RECTA:
o This keyword is supported through the introduction of a new entity (BOX)
o Support both the old and new format (RADIOSS V11 and after) of this keyword
o Autofit function allows to automatically compute the size of the box based on the content
that is displayed
o Resolve the renumbering that occurred in both import and export of set of BOX
 Full support for /SECT/PARAL and /SECT/CIRCLE:
o Support import, creation and modification of these new type of sections
o Resolved ID renumbering upon import that occurred if a cross section shared the same
ID as a contact for example
o Enhanced graphical representation and review for cross sections
 In the find attached subpanel a checkbox allows to take into account tied contacts in the search
for connected elements

HyperCrash
Resolved Issues
 The cross section type /SECT/PARAL and /SECT/CIRCLE were translated if a single node
belonging to the element sets referred in those cross sections was selected for move. The
condition has been modified such that the cross section will be moved only if all the nodes of
the elements referred in the cross section are selected for move.
 When extracting connections from the model if a connection was found to contain more than 1
part but these parts used the same property/material then some of extracted elements were
deleted from the model
 The statistic panel in the LS-Dyna profile showed incorrect information
 Organizing entities using the function “move entities to include” in the right click contextual
froze the session

NVH Packaged Solution Offering


New Features and Enhancements
Analysis Manager
 Reorganization of GUI for easy visualization and handling of multiple analysis definitions
 Loading strength definition using CSV/UNV/DAT files
 Support enhanced infrastructure for module STATE definitions (MPCs and SPCs)
 Option to toggle between selection / restore modal parameter modification option for reduced
models

HyperWorks Desktop 13.0.114 Release Notes 15


Batch Model Reduction
 Capability to create CMS and CDS SE for a control volume assigned to a parent module
 Allows dependent points to be used as CMS SE attachment (A-set orC-set) points which are
Automatically converted to independent points by OptiStruct
 Check and correct connection type tagpoints mis-identified as plot type when determining
attachment point set

Bath Module Prepare


 Option to export coarse display model into a separate file after batch prepare
 Option to load the whole model or just the module last prepared in batch prepare and manual
prepare

Assembly and ID management enhancement


 Saving and rendering of LP representation definitions in template csv file
 Locking of node ID outside module ID range
 Entry field for locking tagpoint with specified ID in the edit tagpoint dialog

Module States
 Option to define multiple state sets and multiple states to each state set
 Support for state definition with multiple MPCs and SPCs for each state set
 Support for selecting enhanced states in Analysis Manager

XML file path replacement


 Automatic mapping of modified and/or missing XML file paths and folders

Job Manager
 Entry field for run options is Job Submission GUI

Normal modes template


 Option to specify Eigen Value Solution type: AMSES, LANCOZ, AMLS
 Option to specify normal mode extraction for fluid modes
 Option to set on/off element checking criteria

Transfer Path Analysis


 Performance improvement in Spindle Loads TPA

Equivalent Radiated Power


 New utility to post process results of exterior structure-borne radiated sound
 Post processing of broadband noise in terms of octave / 1/3 octave, 1/6 octave, etc.

Resolved Issues
 Issue in two-step TPA for multiple subcases in Force File having different frequency ranges
 Issue related to application error during batch mesh coarsening in case where representation
file already had 2D plotels elements
 Issue related to automatic change of Connection location type to Custom Location
 Issue related to Application Error while defining loading strength in General Frequency Response
Process Manager

HyperWorks Desktop 13.0.114 Release Notes 16


 Issue related to METHOD card creation in Transfer Function Solver deck from Traditional TPA
Process Manager
 Issue related to unrealization of realized connections while trying to apply Analysis States
without choosing option to realize connections
 Issues related to duplicate elements creation after batch prepare for certain model files
 Issue related to Transfer Path Analysis in TF-Unv / Force-PCH and TF-Unv / Force-Unv format
files
 Issue related to HM crash when running Batch Prepare and file (write protected with matching
name) exist in export
 Issue related to disappearing Analysis Definition
 Issue related to xml import failure after small modification
 Issue related to assignment of CMS-H3D as representation to a module (Volvo specific)

HyperWorks Desktop 13.0.114 Release Notes 17