Вы находитесь на странице: 1из 27

iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

XFINITY 5600 PRO SATA III SSD

2.5-inch SATA III SSD


IDX56P11, IDX56P21, IDX56P31, IDX56P41, IDX56P51

M.2 2280 SATA III SSD


IDX56P12, IDX56P22, IDX56P32, IDX56P42, IDX56P52

Product Datasheet

Rev 1.2

June 2018

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
Product and specifications of this document is confidential and subject to change without prior notice
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

Revision History

Date Version Changes compared to previous issue


Feb 26, 2018 1.0 Initial Release

Jun 25, 2018 1.1 Modify Block Diagram

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

Table of Contents

1. Introduction ................................................................................... 5
1.1 General Description .................................................................. 5
1.2 Performance ............................................................................ 5
1.3 Key Features ............................................................................ 5
2. Part Numbering .............................................................................. 6
3. Functional Description ................................................................... 6
3.1 Error Detection and Correction ................................................ 7
3.2 Wear-Leveling ........................................................................... 7
3.3 Bad Blocks Management........................................................... 7
3.4 Mean Time between Failures (MTBF) ....................................... 7
3.5 Endurance ................................................................................. 8
3.6 Transfer Mode ......................................................................... 8
3.7 Density Information ................................................................. 8
4. Power Characteristics ..................................................................... 9
4.1 Supply Voltage ......................................................................... 9
4.2.1 SATA 2.5 SSD ........................................................................ 9
4.2.2 SATA M.2 SSD ...................................................................... 10
5. Support ATA Commands ............................................................... 10
6. S.M.A.R.T. .................................................................................... 14
7. Block Diagram .............................................................................. 15
8. Product Images ............................................................................ 16
9. Densities ...................................................................................... 16
10. SSD Pin Assignment .................................................................... 17
10.1 SATA 2.5 SSD Pin Assignment ............................................... 17
10.2 SATA 2.5 SSD Pin Connector Assignments ............................. 18
XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

10.3 SATA 2.5 SSD Power Pin Descriptions ................................... 18


10.4 SATA M.2 SSD Pin Assignments ............................................ 19
10.5 SATA M.2 Pin Descriptions ................................................... 20
11. System Power Requirement ....................................................... 22
11.1 SATA 2.5 SSD ............................................................................ 22
11.2 SATA M.2 SSD .......................................................................... 22
12. Environment Specifications ........................................................ 22
12.1 Reliability .............................................................................. 23
12.2 Performance ........................................................................ 23
12.3 Endurance Rating ................................................................. 24
13. Physical Dimension Specifications .............................................. 24
13.1 SATA 2.5 SSD ......................................................................... 24
13.2 SATA M.2 SSD ....................................................................... 24
14. Mechanical Form Factor.............................................................. 25
14.1 Mechanical Form Factor SATA 2.5 SSD .................................. 25
14.2 Mechanical Form Factor SATA M.2 SSD ................................ 26
15. Important Notes and Warnings .................................................. 27

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

1. Introduction

This product datasheet describes the functional, performance, mechanical, and specifications for the
iNDORCE XFINITY 5600 PRO SATA SSD (Solid State Drive).

1.1 General Description

The XFINITY 5600 PRO SATA SSD is designed to effectively use the SATA interface during READ and WRITE
while providing bandwidth-focused performance. SSD technology enables instant boot times, faster
application load times, reduced power consumption and extended reliability.

1.2 Performance

The measured performance may vary for a number of reasons. The main factors affecting drive
performance are the density of the drive and the interface of the host. In addition, overall system
performance can affect measured drive performance. When comparing drives, it is recommended that all
system variables remain the same, only the drives being tested can be different.

1.3 Key Features


◼ Compact design: JEDEC Compliant.
◼ Unformatted Capacities: 128GB, 256GB, 512GB, 1TB, 2TB.
◼ Maximum performance: Sequential read up to 560MB/s, write up to 520MB/s. (Highest density)
◼ Operating temperature: 0 oC to 70oC.
◼ Compliant with Serial ATA Revision 3.2.
◼ Compatible with SATA 1.5Gbps, 3Gbps and 6Gbps interface.
◼ Enhanced endurance by dynamic and static wear-leveling.
◼ Hardware LDPC ECC correction engine.
◼ Support S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) ATA feature set.
◼ Support Native Command Queuing (NCQ) command.
◼ Supports TRIM Command.
◼ Bad block management.
◼ Support DEVSLP mode.
◼ Support RAID protection.
◼ Sudden power off recovery.
◼ RoHS & CE & FCC certification.

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

2. Part Numbering

Part number decoder with example part number

ID X 56 M 3 1
Form Factor
iNDORCE 1 = 2.5-inch 7mm
2 = M.2 NGFF (2280)
3 = mSATA (Half Size)
4 = mSATA (Full Size)
T = TRENTUM 5 = M.2 NVMe (2280)
Consumer Grade 6 = U.2
X = XFINITY
Enterprise Grade Drive Density
0 = 64GB
I = INTELOGY 1 = 128GB
Industrial Grade 2 = 256GB
3 = 512GB
4 = 1TB
5 = 2TB
56 = 5600
0℃ - 70℃
57 = 5700
-20℃ - 80℃
M = MST
58 = 5800 Designed with Endurance
-40℃ - 85℃ P = PRO
Designed with Performance
U = UTM
Designed with Heavy Application

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

3. Functional Description

3.1 Error Detection and Correction

The XFINITY 5600 SERIES contains Low Density Parity Check (LDPC) of Error Correction Code (ECC) circuitry,
which is for increasing data reliability while reading raw data inside a flash chip. LDPC error-correction
technology, is able to meet output error rate requirements with much higher raw bit error rates, and thus can
greatly extend the usable P/E cycles of NAND flash memory.

3.2 Wear-Leveling

Wear leveling allows data writes to be evenly distributed over the storage media. More precisely, wear
leveling is an algorithm by which the controller in the storage device re-maps logical block addresses to
different physical block addresses in the solid-state memory array.

3.3 Bad Blocks Management

Bad Blocks are blocks that contain one or more invalid bits whose reliability are not guaranteed. The Bad
Blocks may be presented while the SSD is shipped, or may generate during the life time of the SSD. When the
Bad Blocks is detected, it will be flagged, and not be used anymore. The SSD implement Bad Blocks
management and replacement, Error Correct Code to avoid data error occurred. The functions will be enabled
automatically to transfer data from Bad Blocks to spare blocks, and correct error bit. After the reserved block
less than 10 of each channel, the SSD will be locked, and cannot be read and written anymore. Host can send a
vendor ATA command to unlock the SSD for backup data or system from SSD.

3.4 Mean Time between Failures (MTBF)

Failure Rate: The total number of failures within an item population, divided by the total number of life units
expended by that population, during a particular measurement interval under stated condition.
Mean Time between Failures (MTBF): A basic measure of reliability for repairable items: The mean number of
life units during which all parts of the item perform within their specified limits, during a particular
measurement interval under stated conditions.

Product Condition MTBF (Hours)


2.5”/M.2 SATA SSD Telcordia SR-332 GB, 25°C >1,500,000

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

3.5 Endurance

◼ Data Retention: 10 years.


◼ Wear-Leveling Algorithm: Support
◼ Bad Blocks Management: Support.
◼ Error Correct Code: Support.

3.6 Transfer Mode

◼ 2.5”/M.2 SATA SSD support following transfer mode:


◼ Serial ATA I 1.5Gbps
◼ Serial ATA II 3.0Gbps
◼ Serial ATA III 6.0Gbps

3.7 Density Information

Density Cylinders Heads Sectors Sectors in LBA Mode


128GB 16,383 16 63 250,069,680
256GB 16,383 16 63 500,118,192
512GB 16,383 16 63 1,000,215,216
1TB 16,383 16 63 2,000,409,264
2TB 16,383 16 63 4,000,818,528

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

4. Power Characteristics

4.1 Supply Voltage

Parameter Specification
Input Voltage 2.5”: 5V ± 5% / M.2: 3.3V±5%
Maximum Ripple 100mV (peak to peak), 0 to 30 MHz
Maximum Supply Rise Time 100ms

4.2 Operating Power Consumption

Operating power consumption is measured while the 5600PRO 3D NAND SATA SSD is continuously
processing sequential read and write commands (tested separately) for at least 1 minute.

Note: The power and current values in the following table are measured by Ulink standard test program
and equipment. The Read/Write use the H2test tool.

4.2.1 SATA 2.5 SSD

Test 128GB 256GB 512GB 1TB 2TB

Write 1.1W 1.5W 1.55W 1.8W 2W

Read 0.97W 0.97W 1.01W 1.01W 1.3W

Idle 0.8W 0.8W 0.8W 0.8W 0.8W

DEVSLP 2mW 2mW 2mW 2mW 2mW

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

4.2.2 SATA M.2 SSD

Test 128GB 256GB 512GB 1TB 2TB

Write 1.1W 1.5W 1.55W 1.8W 2W

Read 0.97W 0.97W 1.01W 1.01W 1.3W

Idle 0.8W 0.8W 0.8W 0.8W 0.8W

DEVSLP 2mW 2mW 2mW 2mW 2mW

5. Support ATA Commands


ATA Command Set summarizes the ATA command set with the paragraphs that follow
describing the individual commands and the task file for each.

Command Name Code Subcode / Page


General Feature Set
NOP 00h
Data Set Management 06h
Trim 01h
Recalibrate 1Xh
Read Sectors 20h
Read Sectors (w/o retry) 21h
Read Sectors Ext 24h
Read DMA Ext 25h
Read Native Max Address Ext 27h
Read Multiple Ext 29h
Read Log Ext 2Fh
Log Directory 00h
Extended Comprehensive SMART Error Log 03h
Device Statistics Logs 04h
List of supported log pages 00h
General Statistics 01h

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

General Errors Statistics 04h


Transport Statistics 06h
SSD Statistics 07h
Extended SMART Self-test Log 07h
NCQ Error Log 10h
SATA Phy Event Counters Log 11h
Identify Device Data Log 30h
List of Supported Pages 00h
Copy of IDENTIFY DEVICE Data 01h
Capacity 02h
Supported Capabilities 03h
Current Settings 04h
ATA Strings 05h
Security 06h
Serial ATA 08h
Write Sectors 30h
Write Sectors Ext 34h
Write DMA Ext 35h
Set Max Address Ext 37h
Write Multiple Ext 39h
Write DMA FUA Ext 3Dh
Write Log Ext 3Fh
Selective Self-Test log(SMART) 09h
Host Specific(SMART) 80h-9Fh
SCT Command/Status(SCT) E0h
SCT Data Transfer(SCT) E1h
Read Verify Sectors 40h
Read Verify Sectors (w/o retry) 41h
Read Verify Sectors Ext 42h
Write Uncorrectable Ext 45h
Pseudo-UECC with logging 55h
Read FPDMA Queued 60h
Write FPDMA Queued 61h

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

Command Name Code Subcode / Page


Seek 7xh
Execute Device Diagnostic 90h
Initialize Drive Parameters 91h
Download Microcode 92h
Download with offsets and save microcode for immediate
and future use. 03h
Download (without offsets) and save microcode 07h

Download with offsets and save


0Eh/0Fh
microcode for future use / Activate downloaded microcode
SMART B0h
Read Data D0h
Read Thresholds D1h
Enable/Disable Attr Autosave D2h
Save Attribute Values D3h
Exec Off-line Immediate D4h
Execute Off-Line routine
Execute Short Self-test routine (Off- Line)

Execute Extended Self-test routine (Off-Line)


Abort Off-Line Self-test routine
Execute Short Self-test routine (Captive)

Execute Extended Self-test routine (Captive)


Read Log Sector
Write Log Sector
Enable Operations
Disable Operations
Return Status
Sanitize Device B4h
Sanitize Status Ext 00h
Crypto Scramble Ext 11h
Block Erase Ext 12h
Overwrite Ext 14h
Sanitize Freeze Lock Ext 20h
Read Multiple C4h
Write Multiple C5h
Set Multiple Mode C6h

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

Command Name Code Subcode / Page


Read DMA C8h
Read DMA (w/o retry) C9h
Write DMA CAh
Write DMA (w/o retry) CBh
Write Multiple FUA Ext CEh
Standby Immediate E0h
Idle Immediate E1h
Standby E2h
Idle E3h
Read Buffer E4h
Check Power Mode E5h
Sleep E6h
Flush Cache E7h
Write Buffer E8h
Flush Cache Ext EAh
Identify Device ECh
Set Features EFh
Security Set Password F1h
Security Unlock F2h
Security Erase Prepare F3h
Security Erase Unit F4h
Security Freeze Lock F5h
Security Disable Password F6h
Read Native Max Address F8h
Set Max Address F9h
Set Max Set Password 01h
Set Max Lock 02h
Set Max Unlock 03h
Set Max Freeze Lock 04h

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

6. S.M.A.R.T.

The following table defines the specifics of the S.M.A.R.T.

ID Item Threshold
01 Read Error Rate 0
05 Physical Bad Block Count when run-time 0
09 Power-On Hours 0
0C Power-On Count 0
Uncorrectable UNC Sector Count When Read/Write
A0 0
A1 Number of Pure Spare Block 0
A3 Number of Initial Invalid Block 0
A4 Total Erase Count TLC 0
A5 Maximum Erase Count TLC 0
A6 Minimum Erase Count TLC 0
A7 Average Erase Count TLC 0
94 Total Erase Count SLC 0
95 Maximum Erase Count SLC 0
96 Minimum Erase Count SLC 0
97 Average Erase Count SLC 0
A9 Remain Life Percentage 0
B1 Total wearlevel count 50
B5 Total program fail count 0
B6 Total Erase fail count 0
C0 Sudden Power-off Count 0
C2 Temperature 0
C4 Uncorrectable Error Count 16
C7 UltraDMA CRC Error Count 50
E8 Remain free Space(%) 0
Host Total LBAs Written (each write unit = 32MB)
F1 0
F2 Host Total LBAs Read (each read unit = 32MB) 0
F5 Flash Total Units Written TLC (each write unit = 32MB) 0

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

7. Block Diagram

XFINITY 5600 PRO SATA 2.5/M.2 SSD consists of below functional blocks. The advanced architecture is
optimized to provide highest data reliability and transfer performance.

ROM Cache

Microcontroller
SATA
Host SATA 6G
Device Interface

LDPC
DMA Engine
Engine
Flash
Interface

Flash Interface

Flash Memory

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

8. Product Images

2.5”SATA III SSD M.2 NGFF SSD

9. Densities

iNDORCE PID DENSITY


XFINITY 5600 PRO 2.5 SSD 128GB 128GB
XFINITY 5600 PRO 2.5 SSD 256GB 256GB
XFINITY 5600 PRO 2.5 SSD 512GB 512GB
XFINITY 5600 PRO 2.5 SSD 1TB 1TB
XFINITY 5600 PRO 2.5 SSD 2TB 2TB
XFINITY 5600 PRO M.2 SSD 128GB 128GB
XFINITY 5600 PRO M.2 SSD 256GB 256GB
XFINITY 5600 PRO M.2 SSD 512GB 512GB
XFINITY 5600 PRO M.2 SSD 1TB 1TB
XFINITY 5600 PRO M.2 SSD 2TB 2TB

Notes: 1 GB = 1,000,000,000 Byte

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

10. SSD Pin Assignment


10.1 SATA 2.5 SSD Pin Assignment Layout

S1 P1
1

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

10.2 SATA 2.5 SSD Pin Connector Assignments

Pin# Assignment Description


S1 GND Ground Signal
S2 A+
Differential Signal Pair A
S3 A-
S4 GND Ground Signal
S5 B-
Differential Signal Pair B
S6 B+
S7 GND Ground Signal

10.3 SATA 2.5 SSD Power Pin Descriptions

Pin# Assignment Description


P1 V3.3 3.3V Power, No Connect
P2 V3.3 3.3V Power, No Connect
P3 DEVSLP Device Sleep Pin
P4 GND Ground Signal
P5 GND Ground Signal
P6 GND Ground Signal
P7 V5.0 5V Power
P8 V5.0 5V Power
P9 V5.0 5V Power
P10 GND Ground Signal
P11 DAS Device Activity Signal
P12 GND Ground Signal
P13 V12 12V Power, No Connect
P14 V12 12V Power, No Connect
P15 V12 12V Power, No Connect

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

10.4 SATA M.2 SSD Pin Assignments Layout

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

10.5 SATA M.2 Pin Descriptions

Pin# Assignment Description Pin# Assignment Description

1 GND Ground 39 GND Ground

2 3.3V Supply pin 40 N/A N/A


SATA differential
3 GND Ground 41 SATA-B+ signals
4 3.3V Supply pin 42 N/A N/A
SATA differential
5 N/A N/A 43 SATA-B- signals
6 N/A N/A 44 N/A N/A

7 N/A N/A 45 GND Ground

8 N/A N/A 46 N/A N/A


SATA differential
9 GND Ground 47 SATA-A- signals
Status indicators via
10 DAS/DSS LED 48 N/A N/A
SATA differential
11 GND Ground 49 SATA-A+ signals
12 Module key 50 N/A N/A

13 Module key 51 GND Ground

14 Module key 52 N/A N/A

15 Module key 53 N/A N/A

16 Module key 54 N/A N/A

17 Module key 55 N/A N/A


Reserve for MFG Manufacturing
18 Module key 56 data data line
19 Module key 57 GND Ground

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

Pin# Assignment Description Pin# Assignment Description


Reserve for MFG Manufacturing
20 N/A N/A 58 Clock clock line
21 GND Ground 59 Module key

22 N/A N/A 60 Module key

23 N/A N/A 61 Module key

24 N/A N/A 62 Module key

25 N/A N/A 63 Module key

26 N/A N/A 64 Module key

27 GND Ground 65 Module key

28 N/A N/A 66 Module key

29 N/A N/A 67 N/A N/A

30 N/A N/A 68 SUSCLK(I)(0/3.3V) N/A

31 N/A N/A 69 GND Ground

32 N/A N/A 70 3.3V Supply pin

33 GND Ground 71 GND Ground

34 N/A N/A 72 3.3V Supply pin

35 N/A N/A 73 GND Ground

36 N/A N/A 74 3.3V Supply pin

37 N/A N/A 75 GND Ground

38 DEVSLP(I) Device Sleep, Input

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

11. System Power Requirement

11.1 SATA 2.5 SSD

Parameter Symbol Min Typ Max Unit Remark


Supply voltage VCC 4.5 5.0 5.5 V
Read/Write power PW - 2 - W RMS value
Standby power PS - 0.8 - W RMS value
DEVSLP mode Pd 0.002 W

11.2 SATA M.2 SSD

Parameter Symbol Min Typ Max Unit Remark


Supply voltage VCC 3.14 3.3 3.46 V
Read/Write power PW - 2 - W RMS value
Standby power PS - 0.8 - W RMS value
DEVSLP mode Pd 0.002 W

12. Environment Specifications

Type Value
Operating 0oC to 70oC
Temperature Non-Operating -40oC to 85oC
Operating 40oC,8% to 90%, noncondensing
Humidity
Non-Operating 40oC,8% to 93%, noncondensing
Operating N/A
Vibration Non-Operating 5–800Hz at 4.02 gRMS
Operating 1500G/0.5msec
Shock Non-Operating 1500G/0.5msec

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

12.1 Reliability

Type Value
Data Retention 10 years @ 25oC

Endurance Enhanced global dynamic and static wear-leveling algorithm

MTBF (@ 25oC) 1 1,500,000 hours

Notes:
The Mean Time Between Failures (MTBF) is calculated using a prediction methodology, Telcordia SR-332,
which based on reliability data of the individual components in the SSD. It assumes nominal voltage, with all other parameters
within specified range.

12.2 Performance

Type Value
Host Interface Speed SATA 3.0 Gb/s and SATA 6.0 Gb/s
Sequential Read: up to 540MB/s
Sequential Write: up to 480MB/s
128GB
Random Read [4KB]: up to 82,000 IOPS
Random Write [4KB]: up to 75,000 IOPS
Sequential Read: up to 550MB/s
Sequential Write: up to 490MB/s
256GB
Random Read [4KB]: up to 90,000 IOPS
Random Write [4KB]: up to 82,000 IOPS
Sequential Read: up to 560MB/s
Sequential Write: up to 500MB/s
Data Transfer Rate 512GB
Random Read [4KB]: up to 90,000 IOPS
Random Write [4KB]: up to 85,000 IOPS
Sequential Read: up to 560MB/s
Sequential Write: up to 520MB/s
1TB
Random Read [4KB]: up to 92,000 IOPS
Random Write [4KB]: up to 85,000 IOPS
Sequential Read: up to 560MB/s
Sequential Write: up to 520MB/s
2TB
Random Read [4KB]: up to 92,000 IOPS
Random Write [4KB]: up to 85,000 IOPS

Notes:
The performance may vary according to different product capacity and platform.

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

12.3 Endurance Rating

Capacities Endurance TBW


128GB 70TB
256GB 100TB
512GB 200TB
1TB 400TB
2TB 500TB

13. Physical Dimension Specifications

13.1 SATA 2.5 SSD

Type Value
Form factor SATA 2.5 inch
Length 100.00 mm +/- 0.15mm
Width 69.85 mm +/- 0.15mm
Thickness 7 mm +/- 0.1mm
Mounting Screws M3x0.5 non-self-tapping or thread forming
Maximum Screw
3.5mm (0.138”)
Penetration
Screw Torque
4kgf-cm/7kgf-cm
(nominal/max)

13.2 SATA M.2 SSD


Type Value
Form factor M.2_ NGFF
Length 80.00 mm +/- 0.15mm
Width 20.00 mm +/- 0.15mm
Thickness MAX 3.5 mm

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

14. Mechanical Form Factor

14.1 Mechanical Form Factor SATA 2.5 SSD (Units in mm)

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

14.2 Mechanical Form Factor SATA M.2 SSD (Units in mm)

Scale enlarged is to show the detail, it is not the actual size of the form factor

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation
iNDORCE XFINITY 5600 PRO SATA SSD Product Datasheet

15. Important Notes and Warnings

TUL Corporation. (“TUL") general policy does not recommend the use of its products in life support applications, as
failure or malfunction of the product may directly threaten life or injury. Without limiting the foregoing, TUL shall
not be liable for any loss, injury or damage resulting from the use of its products in any of the following
applications:

- Control devices of automotive vehicles, trains, ship and transport equipment


- Special applications such as military related equipment, nuclear reactor control and aerospace
- Disaster prevention and crime prevention security system
- Medical related equipment, including medical measuring equipment or device

Therefore, when using iNDORCE branded products in life support systems or other applications that may cause
damage, injury or loss of life, the product should only be included in systems with appropriate redundancy, fault
tolerance or backup capabilities. Users of iNDORCE branded products in Life Support or other such applications are
responsible for all risks associated with such use and agree to indemnify and protect TUL and its affiliates in
accordance with the terms and conditions of sale in the order confirmation. It is protected from damage.
By its nature, security measures can be circumvented. TUL cannot and does not guarantee that unauthorized
personnel will not access the data, and TUL does not undertake any guarantees to the fullest extent permitted by
law.

This document and related materials are for reference only and are subject to change without notice. TUL assumes
no responsibility for any errors or representations that may arise from the furnishing, performance or use of this
document or related materials. In the event that TUL or its authorized representative does not sign a written
agreement, TUL expressly disclaims any express or implied warranties and indemnities that may or may be
associated with this document and related materials, and any user or related material in this document agrees to
this. Class files and related materials. Disclaimer is a prerequisite for receipt and use. Each user of this document
expressly disclaims all warranties and warranties of any kind with respect to this document and/or related
materials, whether express or implied, including but not limited to any warranties of merchantability or fitness for a
particular purpose or infringement. Implied guarantee. Any TUL and its affiliates under any contract, negligence,
strict liability or other lawful or fair use of liability theory, income or profits or other incidental, punitive, indirect,
special or consequential damages, including but not limited to any TUL and Personal injury or death of its affiliates,
property damage, loss of data or purchase of alternative products, technology or services.
No part of this document may be reproduced, transmitted, transcribed, stored or translated in any form or by any
means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise. , with prior written consent from
the TUL official.

All parts of the TUL documentation are protected by copyright law and all rights are reserved. iNDORCE and the
iNDORCE logo are registered trademarks or trademarks of TUL Corporation or its affiliates in Taiwan and/or other
countries. All other trademarks are the property of their respective owners. Performance depends on your
hardware and software components and configuration. Product specifications are subject to change without
notice. The displayed image may differ from the actual product. Not all products are available in all regions of the
world.

© 2018 TUL Corporation or its affiliates. all rights reserved.

XFINITY 5600 PRO SATA SSD TUL Corporation, reserves the right to change products or specifications without notice.
©2018 TUL Corporation

Вам также может понравиться