JOB NO. 0241014.030.

032
JOB NAME CanAm- Tru Grit Taylor Way
SUBJECT Total dynamic head
CALC BY RLB DATE 4/25/2017
CHK BY KMS DATE 5/3/2017

Friction Loss Calculator for Water in Full Pipe Flow Hazen-Williams Equation

Hazen-Williams Equation:

V = k*C*Rh0.63S0.54 where S=hf/L; Q=V*A; Rh=D/4


and k=1.381 for English units (ft and seconds)
or k=0.85 for SI units (m and seconds)

Rearranged to solve for head loss in English units:

hf = 10.4[Q1.85/(C1.85*D4.87)]*L

where hf = friction loss in feet of head, Q = flow rate in gallons per minute,
C = Hazen-Williams coefficient for pipe roughness, D = pipe inner diameter in inches,
and L = total equivalent piping length in feet.

Total equivalent head loss through pretreatment system


hL
Friction loss 5.3 (ft)
Gravity head loss 12.7 (ft)
Total Dynamic Head total = 18.0 (ft)
7.8 (psi)
FRICTION LOSSES
Enter values for flow rate, pipe inner diameter and pipe roughness factor

Q= 68 (Operating Flow Rate, gallons per minute)


D= 2 (inches)
C= 150 PVC
L= 64 (ft) length, see calculation on separate sheet

The spreadsheet will calculate the corresponding pressure drop:


hf = 5.3 (ft)
velocity = 6.9 (ft/sec)

GRAVITY LOSS
Gravity Head (hg) = g(z2-z1)
where, g = specific wt of water (62.4 lb/ft3), z1 = starting (upstream) elevation, z2 = final elevation

z2 = 22.0 ft
z1 = 9.3 ft
hg = 12.7 ft

\\edmdata01\projects\241\014\R\Taylor Way Egr Rpt\Appendices\Appendix D_calcs\Lift Station Pump Sizing_DRAFT_KMS_rlb 1 of 6


Pipe Fittings - Equivalent Pipe Lengths, pump discharge

Equivalent Feet of Pipe

Nominal Pipe Tee, Tee, Side Insert PVC Male-Female Globe Valve Angle Valve Gate Valve Check
Size (Inches) Straight Pipe (ft) 90o Elbow 45o Elbow Through Outlet Coupling Insert Adapters (fully open) (fully open) (fully open) Valve
4 1 10.1 5.4 6.7 22.0 4.0 9.0 112 57 2.3 25
6 1 15.2 8.1 10.1 32.0 6.3 14.0 168 84 3.4 40
8 1 20.0 10.6 13.3 38.0 ---- ---- 225 115 4.6 50

CALCULATOR - INSERT NUMBER OF EACH

Nominal Pipe Tee, Tee, Side Insert PVC Male-Female Globe Valve Angle Valve Gate Valve Check
Size (Inches) Straight Pipe (ft) 90o Elbow 45o Elbow through Outlet Coupling Insert Adapters (fully open) (fully open) (fully open) Valve
2 22.0 5 1
2-1/2
3
4
6
8
Equivalent Ft 22.0 27.5 0 0 0 0 0 0 0 0 14 63.5
TOTAL

s:\sharedoc\000examples\environ\Lift Station Pump Sizing_DRAFT_KMS_rlb RPT-equiv length 5/5/2017


Table of Hazen-Williams Coefficients

Material C
Plastic (PVC, PE) 140-150
Steel, new unlined 140
Copper 130-140
Galvanized iron 120
Cast Iron :
New, unlined 130
10 yr. old 107-113
20 yr. old 100
30 yr. old 90
Brick Sewer 100
Corrugated Steel Pipe 60

s:\sharedoc\000examples\environ\Lift Station Pump Sizing_DRAFT_KMS_rlb


RPT-C Values 5/5/2017
Pump Selected:
GOULDS WS05
JOB NO. 0241014.030.032
JOB NAME CanAm- Tru Grit Taylor Way
SUBJECT Pump Vault Sizing
CALC BY RLB DATE
CHK BY KMS DATE

Objective: To calculate manhole diameter

Assumptions:
Total Dynamic Head (TDH) Calculations: Lift Station Pump Sizing Documents
Total= 18.00 ft
Pump Flow Rate at TDH from Pump Curve: 68 gpm
0.15 cfs
Solutions:
Size Pump Vault:

Overflow Pipe Invert (assumed) 11.77 ft


Pump on el. 11.3 ft Pump Intake 9.3 ft
Pump off el. 9.8 ft Bottom 8.8 ft
PS rim el. 14.0 ft Total depth 5.2 ft
Pump Height 1.6 ft
Total width needed for pump, 6" between pump and walls 24 in 2 ft
Total width needed for pump, rail retrieval 30.1 in 2.5 ft

Determine Pump run time based on Manhole Diameter:

Active
Active storage Pump Run
Type 2 Manhole Diameter Area Storage
volume Time
Depth
in ft ft2 ft ft3 min
48 4 12.6 1.5 18.8 2.1
54 4.5 15.9 1.5 23.9 2.6
60 5 19.6 1.5 29.5 3.2
72 6 28.3 0.0 0.0 0.0

The lift station will be a 54" Type 2 Manhole, with a depth of about 5 feet.