Gen Motor Datasheet BF8M1015 (1500 min-1 / 50 Hz)

Engine
Type
BF8M1015C ‚ ‚ ‚ ‚ ‚
BF8M1015CP ‚ ‚ ‚
Speed [min-1] 1500 1500 1500 1500 1500 1500 1500 1500
Net frequency [Hz] 50 50 50 50 50 50 50 50
Power standard COP PRP LTP
Power level G1 G3 G1 G2 G3 G1 G2 G3
Exhaust emission standard -- -- -- -- -- -- -- --
General
Aspiration turbo, CAC turbo, CAC turbo, CAC
No of cylinders 8 8 8 8 8 8 8 8
Configuration V V V
Injection system BOSCH inline pump BOSCH inline pump BOSCH inline pump
Displacement [l] 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9
Bore [mm] 132 132 132 132 132 132 132 132
Stroke [mm] 145 145 145 145 145 145 145 145
Compression ratio 16.5 16.5 16.5 16.5 16.5 16.5 16.5 16.5
Mean effective pressure [bar] 16.2 19.4 18.6 19.7 21.9 20.5 22.7 24.0
Piston speed [m/s] 7.26 7.26 7.26 7.26 7.26 7.26 7.26 7.26
Rotation (looking at flywheel) counter clock wise counter clock wise counter clock wise
No of teeth on flywheel ring gear 167 167 167 167 167 167 167 167
Governor performance
Speed droop (static) mech. gov. [%] ! ! ! ! ! ! ! !
Speed droop (static) electr. gov. (EMR/GAC) [%] 0 0 0 0 0 0 0 0
Governing standards
to ISO 8528 Parts 1 and 5 G2 G2 G2
Moment of inertia
Engine without flywheel [kg m2] 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Flywheel (standard genset spec.) [kg m2] 2.26 2.26 2.26 2.26 2.26 2.26 2.26 2.26
Max. step load acceptance, 1st step [%] ! ! 70 65 60 ! ! !
Sound power at full load, incl. cooling system5 [dB(A)] 118.5 ! 119.5 119.5 119.5 119.5 119.5 119.5
Sound press. (1m average, full load), incl. cool. syst. [dB(A)] 104 ! 105 105 105 105 105 105
Weight
Engine dry, w/o cooling system [kg] 1060 1060 1060 1060 1060 1060 1060 1060
Engine with cooling system [kg] 1240 1265 1265 1265 1300 1265 1270 1300
Lubrication system
Oil specification see operation manual see operation manual see operation manual
Oil consumption (as % of fuel consumption) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Oil capacity (sump) [l] 45 45 45 45 45 45 45 45
Min. oil pressure (warning) [bar] 3 3 3 3 3 3 3 3
Min. oil pressure (shut down) [bar] 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7
Max. permissible oil temperature (oil pan) [°C] 130 130 130 130 130 130 130 130
Output
Gross output1 [kW] 333.0 399.0 380.0 402.0 448.0 418.0 459.0 490.0
Fan reduction [kW] 10.7 14.1 10.7 10.7 14.1 10.7 9.3 14.1
Net flywheel1 [kW] 322.3 384.9 369.3 391.3 433.9 407.3 449.7 475.9
Electrical output2 [kVA] 375 447 429 455 510 479 528 559
Fuel System
Fuel consumption
25% load3 [l/h] 22.3 26.7 25.0 26.2 30.0 26.7 29.1 31.5
50% load3 [l/h] 40.6 49.9 46.7 48.8 56.4 50.5 55.5 61.8
75% load3 [l/h] 60.4 74.5 69.7 73.3 84.9 75.8 84.0 93.2
100% load3 [l/h] 80.9 102.1 94.3 99.6 118.7 103.5 117.5 131.3
25% load [g/kWh] 224 224 220 218 224 214 212 215
50% load [g/kWh] 204 209 205 203 210 202 202 211
75% load [g/kWh] 202 208 204 203 211 202 204 212
100% load [g/kWh] 203 214 207 207 221 207 214 224
Max. suction head of fuel feed pump [m] 2 2 2 2 2 2 2 2

© 2004 1
Gen Motor Datasheet BF8M1015 (1500 min-1 / 50 Hz)

Engine
Type
BF8M1015C ‚ ‚ ‚ ‚ ‚
BF8M1015CP ‚ ‚ ‚
Speed [min-1] 1500 1500 1500 1500 1500 1500 1500 1500
Net frequency [Hz] 50 50 50 50 50 50 50 50
Power standard COP PRP LTP
Power level G1 G3 G1 G2 G3 G1 G2 G3
Exhaust emission standard -- -- -- -- -- -- -- --
Cooling System
General engine cooling data
Max. perm. coolant outlet temperature [°C] 103 103 103 103 103 103 103 103
Max. perm. flow resistance (cool. syst. and piping) [bar] 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35
Max. temperature of coolant (warning) [°C] 105 105 105 105 105 105 105 105
Max. temperature of coolant (shutdown) [°C] 108 108 108 108 108 108 108 108
Temperature at which thermostat starts to open [°C] 83 83 83 83 83 83 83 83
Temperature at which thermostat is fully open [°C] 95 95 95 95 95 95 95 95
Delivery of coolant pump [m3/h] 20.8 20.8 20.8 20.8 20.8 20.8 20.8 20.8
Min. pressure before coolant pump [bar] 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Temperature at CAC outlet at standard conditions [°C] 50 50 50 50 50 50 50 50
DEUTZ cooling system
Coolant capacity (engine) [l] 21 21 21 21 21 21 21 21
Coolant capacity (incl. cooling unit) [l] 99 102 102 102 116 102 102 116
Air to boil (max. permissible cool. air temp. at fan) [°C] 59 54 55 52 49 52 54 49
Fan power consumption4 [kW] 10.7 14.1 10.7 10.7 14.1 10.7 9.3 14.1
Cooling air flow [m3/h] 24120 33120 24120 24120 33120 24120 32940 33120
Air pressure loss 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
Heat Balance
Heat dissipation (engine radiator)6 [kW] 184 214 202 211 237 202 223 237
Heat dissipation (CAC)6 [kW] 73 101 94 103 125 94 109 124
Heat dissipation (convection) [kW] 26 32 30.5 32.5 36 ! 37 40
Inlet / Exhaust Data
Max. intake depression (Switch setting) [mbar] 50 50 50 50 50 50 50 50
Combustion air volume [m3/h] 1524 1709 1663 2092 1848 1953 1909 2002
Max. exhaust back pressure [mbar] 50 50 50 50 50 50 50 50
Max. exhaust gas temperature [ºC] 460 535 485 510 560 515 540 600
Exhaust gas flow (at above temp) [m3/h] 3934 4870 4395 4765 5377 5375 5410 6012
Exhaust flange / pipe diameter [mm] 100 118 100 100 118 100 100 118
Electrical System
Voltage [V] 24 24 24 24 24 24 24 24
Starter [kW] 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4
Alternator output [A] 55 55 55 55 55 55 55 55
Batteries (minimum capacity, cold start limit -5°C) [Ah] 2 x 143 2 x 143 2 x 143

! Data under examination


1Ratings in accordance with ISO 3046.
2Ratings in accordance with ISO 8528, based on alternator efficiency of 93% to 94%.
3At calorific value 42700 kJ/kg + 5 %, density 0.835 kg/dm3, temperature 280 K.
4Technical data and max. permissible torque for fan drive see data sheet.
5Sound power values measured in accordance with ISO 6798.
6The heat quantities are valid for the dimensioning of the cooling system. They are given for the engine with the highest fuel consumption.
For further information see ELTAB / Pocket book.
For further application guidance see DEUTZ Installation Manual.
All data are provided for informational purposes only and are subject to amendment.