Mega-Guard AMS:
LUB. OIL MAIN ENGINE
1 9
PRESSURE LOW OVER SPEED
Alarm and Monitoring System
LUB. OIL OIL MIST
2 10
HIGH TEMPERATURE DETECTOR ALARM Tank Gauging
FUEL OIL START FUEL OIL
3
LOW PRESSURE STANDBY PUMP
11
Extension Alarm System for UMS
FUEL OIL START LUB. OIL
4
HIGH TEMPERATURE STANDBY PUMP
12 LED alarm indication for digital inputs
5
COOLING WATER
HIGH TEMPERATURE
BILGE WATER
LEVEL HIGH
13 LCD alarm/value indication for analog inputs
6
FUEL OIL LEAK
INJECTION PIPE
BILGE LEVEL
PUMP A RUNNING
14 LED alarm indication in cabins for UMS
7
FUEL OIL LEAK BILGE LEVEL
15
Maximum 192 digital inputs
FLY WHEEL PUMP B RUNNING
8
FUEL TANK BUNKER TANK
16
Maximum 96 analog inputs
LEVEL LOW LEVEL HIGH
Maximum 96 serial link inputs
STOP
ACK.
HORN Power supply voltage: 19~32Vdc
SYSTEM ON FAULT World wide service network
Class type approved (UMS)
Features
The Mega-Guard Alarm and Monitoring System (AMS) is
LUB. OIL MAIN ENGINE
1
PRESSURE LOW OVER SPEED
9 the perfect solution for small vessels. The Mega-Guard AMS
supports both manned and unmanned machinery space
LUB. OIL OIL MIST applications.
2 10
HIGH TEMPERATURE DETECTOR ALARM
3
FUEL OIL START FUEL OIL
11
The Alarm Panel is the main component of the AMS and this
LOW PRESSURE STANDBY PUMP panel contains 16 digital inputs with a text window and LED
FUEL OIL START LUB. OIL alarm indication. This stand-alone panel communicates with
4 12
HIGH TEMPERATURE STANDBY PUMP other Alarm Panels and with the Group Alarm Panel on bridge
via a redundant Ethernet network. The Group Alarm Panel
Alarm Panel
ACK.
STOP The Mega-Guard AMS can also be expanded with an
HORN
Extension Alarm System for unmanned machinery space
notation (UMS). In this case the EAS Operator Panel is
SYSTEM ON FAULT required for Attended/Unattended selection, on duty selection
and patrol timer functions. An EAS 3 LED Panel is installed in
cabin's and public spaces in order to call the on duty engineer
in case an alarm is coming.
Alarm Panel
The Alarm Panel supports 16 potential free alarm contacts
(digital inputs) and 2 alarm inhibition inputs. Alarm Panels
are interconnected by a redundant Ethernet network. Ring
Ethernet wiring is fully supported by the Mega-Guard AMS.
The Alarm Panel is equipped with an Alarm LED for each
input channel and an Acknowledge and Stop Horn pushbutton.
A text sheet with channel description for each channel is
inserted from the top. Background illumination will shine
Rear view Alarm Panel
2
Ta n k g a u g i n g a n d m o n i t o r i n g
Capacity
STOP
ACK.
The Mega-Guard AMS has the following maximum I/O HORN
configuration:
SYSTEM ON FAULT
192 digital inputs (12x Alarm Panel).
96 analog inputs (4x 24ch Analog Input I/O Module).
96 serial link inputs.
A maximum of 4x EAS Operator Panels and a maximum of
4x Group Alarm Panels are supported.
This unit is used for Attended/Unattended selection and Patrol Timer On/Off ENGINE ROOM ALARM
selection (via keyswitch). This unit is applied in case it is not allowed to execute
SYSTEM ON
these functions on the EAS Operator Panel. The Watch Entrance Unit is
bulkhead mounted near the entrance of the engine room.
Timer Reset Units LAMP
ACCEPT
This unit is used in order to reset the patrol timer. TEST
Timer Reset Units are bulkhead mounted on various locations in engine room.
EAS Control Processor
This unit takes care of the communication in between the EAS 3 LED Panels,
Watch Entrance Unit and the Timer Reset Units. The EAS Control Processor
is mounted on DIN rail and is installed inside a console; close to the
EAS Operator Panel.
3
Mega-Guard Alarm and Monitoring System
Ethernet Ethernet
A B
Bridge
AUXILIARY
3 FIRE 11
MACHINERY
5 BILGE ALARM 13
6 14
7 15
8 16
STOP
ACK.
HORN
SYSTEM ON FAULT
AUTOMATION TECHNOLOGY
ETH
MAIN
c
SYSTEM ON
FAILURE
AMS
NODE XX
TIMER KEY. SW. ON/OFF
ATTENDED INPUT
UNATTENDED INPUT
GND
ATTENDED OUTPUT
UNATTENDED OUTPUT
TIMER ON/OFF
di 9
di 10
di 11
gnd12
do 13
do 14
di 15
TIMER
ON
TIMER
ATTENDED
WATCH
ON
WATCH
TIMER
EXPIRED
CHIEF
ENG.
1st
2nd
ENG.
3rd
Panel
TIMER OUTPUT do 16 UNATTENDED GEA
OFF OFF ENG. ENG.
RESET INPUT di 17
BARCODE LABEL
ETH GND gnd18
B/U TIMER EXPIRED do 19
PRODUCT LABEL
G.E.A. INPUT di 20
Watch Timer
5 c STOP HORN INPUT di 21
HORN
6 no G.E.A. OUTPUT do 22
7 r+ gnd23 STOP
ADDRESS
ACK.
8 r- RESISTOR AUTOMATION TECHNOLOGY
gnd24 HORN
LUB. OIL OIL MIST LUB. OIL OIL MIST LUB. OIL OIL MIST LUB. OIL OIL MIST
2 10 2 10 2 10 2 10
HIGH TEMPERATURE DETECTOR ALARM HIGH TEMPERATURE DETECTOR ALARM HIGH TEMPERATURE DETECTOR ALARM HIGH TEMPERATURE DETECTOR ALARM
FUEL OIL START FUEL OIL FUEL OIL START FUEL OIL FUEL OIL START FUEL OIL FUEL OIL START FUEL OIL
3 11 3 11 3 11 3 11
LOW PRESSURE STANDBY PUMP LOW PRESSURE STANDBY PUMP LOW PRESSURE STANDBY PUMP LOW PRESSURE STANDBY PUMP
FUEL OIL START LUB. OIL FUEL OIL START LUB. OIL FUEL OIL START LUB. OIL FUEL OIL START LUB. OIL
4 12 4 12 4 12 4 12
HIGH TEMPERATURE STANDBY PUMP HIGH TEMPERATURE STANDBY PUMP HIGH TEMPERATURE STANDBY PUMP HIGH TEMPERATURE STANDBY PUMP
COOLING WATER BILGE WATER COOLING WATER BILGE WATER COOLING WATER BILGE WATER COOLING WATER BILGE WATER
5 13 5 13 5 13 5 13
HIGH TEMPERATURE LEVEL HIGH HIGH TEMPERATURE LEVEL HIGH HIGH TEMPERATURE LEVEL HIGH HIGH TEMPERATURE LEVEL HIGH
FUEL OIL LEAK BILGE LEVEL FUEL OIL LEAK BILGE LEVEL FO FO GEN. FO FO GEN. FUEL OIL LEAK BILGE LEVEL FUEL OIL LEAK BILGE LEVEL
6 14 6 14 START LUB OIL SERVICE START LUB OIL SERVICE 6 14 6 14
INJECTION PIPE PUMP A RUNNING INJECTION PIPE PUMP A RUNNING BATTERY
BUNKER DAY
TANK TANK
SERVICE
BATTERY
BUNKER DAY
TANK TANK
SERVICE INJECTION PIPE PUMP A RUNNING INJECTION PIPE PUMP A RUNNING
TANK TANK BATTERY TANK TANK BATTERY
FUEL OIL LEAK BILGE LEVEL FUEL OIL LEAK BILGE LEVEL FUEL OIL LEAK BILGE LEVEL FUEL OIL LEAK BILGE LEVEL
7 15 7 15 7 15 7 15
FLY WHEEL PUMP B RUNNING FLY WHEEL PUMP B RUNNING FLY WHEEL PUMP B RUNNING FLY WHEEL PUMP B RUNNING
FRESH PS SB FRESH PS SB
RADIO SEWAGE EMERG. RADIO SEWAGE EMERG.
WATER BALLAST BALLAST WATER BALLAST BALLAST
FUEL TANK BUNKER TANK FUEL TANK BUNKER TANK BATTERY TANK BATTERY BATTERY TANK BATTERY FUEL TANK BUNKER TANK FUEL TANK BUNKER TANK
TANK TANK TANK TANK TANK TANK
8 16 8 16 8 16 8 16
LEVEL LOW LEVEL HIGH LEVEL LOW LEVEL HIGH LEVEL LOW LEVEL HIGH LEVEL LOW LEVEL HIGH
SYSTEM ON FAULT SYSTEM ON FAULT SYSTEM ON FAULT SYSTEM ON FAULT SYSTEM ON FAULT SYSTEM ON FAULT
AUTOMATION TECHNOLOGY AUTOMATION TECHNOLOGY AUTOMATION TECHNOLOGY AUTOMATION TECHNOLOGY AUTOMATION TECHNOLOGY AUTOMATION TECHNOLOGY
Alarm Panel Alarm Panel LCD Operator Panel LCD Operator Panel Alarm Panel Alarm Panel
A A A A
B 1 13 B B 1 13 B
C C C C
A A A A
B 2 14 B B 2 14 B
C C C C
A A A A
B 3 15B B 3 15B
C C C C
A A A A
B 4 16 B B 4 16 B
C C C C
A A A A
B 5 17 B B 5 17 B
C C C C
A A A A
ALARM CONTACT WIRING ALARM CONTACT WIRING ALARM CONTACT WIRING ALARM CONTACT WIRING
B 6 18 B B 6 18 B
C C C C
A A A A
B 7 19 B B 7 19 B
C C C C
A A A A
B 8 20 B B 8 20 B
C C C C
A A A A
B 9 21 B B 9 21 B
C C C C
A A A A
B 10 22 B B 10 22 B
C C C C
A A A A
B 11 23 B B 11 23 B
C C C C
A A A A
B 12 24 B B 12 24 B
C C C C
24 Ch. 24 Ch.
Analog Input I/O Module Analog Input I/O Module