S10 225 55 110 160 200 275 2 2 110 ... 127 } 3RT10 64-6AF36 5.7
220 ... 240 } 3RT10 64-6AP36
265 75 132 160 250 330 2 2 110 ... 127 } 3RT10 65-6AF36
220 ... 240 } 3RT10 65-6AP36
3RT10 7 .
300 90 160 200 250 330 2 2 110 ... 127 } 3RT10 66-6AF36
220 ... 240 } 3RT10 66-6AP36
S12 400 132 200 250 400 430 2 2 110 ... 127 } 3RT10 75-6AF36 9.1
220 ... 240 } 3RT10 75-6AP36
500 160 250 355 400 610 2 2 110 ... 127 } 3RT10 76-6AF36
NSB0605g
S10 225 55 110 160 200 275 2 2 96 ... 127 } 3RT10 64-6NF36 5.7
200 ... 277 } 3RT10 64-6NP36
265 75 132 160 250 330 2 2 96 ... 127 } 3RT10 65-6NF36
200 ... 277 } 3RT10 65-6NP36
300 90 160 200 250 330 2 2 96 ... 127 } 3RT10 66-6NF36
200 ... 277 } 3RT10 66-6NP36
S12 400 132 200 250 400 430 2 2 96 ... 127 } 3RT10 75-6NF36 9.1
200 ... 277 } 3RT10 75-6NP36
500 160 250 355 400 610 2 2 96 ... 127 } 3RT10 76-6NF36
200 ... 277 } 3RT10 76-6NP36
For further voltages, see page 3/37. 1) As an option, the 3RT10 54-1 contactor (55 kW)
For accessories, see page 3/42. can also be supplied with bar connections
For spare parts, see page 3/64. instead of box terminals. No additional charge
is made. At the 8th digit of the Order No.,
For technical data, see page 3/104, 3/120. replace the "1" with "6", e.g. 3RT10 54-6. ..
For int. circuit diagrams, see page 3/148.
For dimension drawings, see page 3/220.
S12 400 132 200 250 400 430 1 1 96 ... 127 } 3RT10 75-6PF35 9.1
200 ... 277 } 3RT10 75-6PP35
500 160 250 355 400 610 1 1 96 ... 127 } 3RT10 76-6PF35
200 ... 277 } 3RT10 76-6PP35
3RT10 56
Solid-state operating mechanism · with AS-Interface
and remaining lifetime indication
S6 115 37 55 75 110 160 1 1 96 ... 127 } 3RT10 54-1QF35 3.5
200 ... 277 } 3RT10 54-1QP35
150 45 75 90 132 185 1 1 96 ... 127 } 3RT10 55-6QF35 3.1
200 ... 277 } 3RT10 55-6QP35
185 55 90 110 160 215 1 1 96 ... 127 } 3RT10 56-6QF35
200 ... 277 } 3RT10 56-6QP35
S10 225 55 110 160 200 275 1 1 96 ... 127 } 3RT10 64-6QF35 5.7
200 ... 277 } 3RT10 64-6QP35
NSB0611g 265 75 132 160 250 330 1 1 96 ... 127 } 3RT10 65-6QF35
200 ... 277 } 3RT10 65-6QP35
300 90 160 200 250 330 1 1 96 ... 127 } 3RT10 66-6QF35
200 ... 277 } 3RT10 66-6QP35
S12 400 132 200 250 400 430 1 1 96 ... 127 } 3RT10 75-6QF35 9.1
200 ... 277 } 3RT10 75-6QP35
500 160 250 355 400 610 1 1 96 ... 127 } 3RT10 76-6QF35
200 ... 277 } 3RT10 76-6QP35
For further voltages, see page 3/37. 1) As an option, the 3RT10 54-1 contactor (55 kW)
For accessories, see page 3/42. can also be supplied with bar connections
For spare parts, see page 3/64. instead of box terminals. No additional charge
is made. At the 8th digit of the Order No.,
For technical data, see page 3/104, 3/120. replace the "1" with "6", e.g. 3RT10 54-6. ..
For int. circuit diagrams, see page 3/148.
For dimension drawings, see page 3/220.
Application
AC and DC operation The contactors are suitable for (AC-1) or as contactors, for The accessories for the SIRIUS
(size S3) use in any climate. They are example in variable-speed 3RT10 contactors can also be
UC operation (AC/DC) safe from touch to DIN VDE drives which normally only have used here.
(sizes S6 to S12) 0106 Part 100. to carry the current.
IEC 60 947, EN 60 947 3RT14 contactors are used for
(VDE 0660) switching resistive loads
For further voltages, see page 3/37. For spare parts, see page 3/63. For int. circuit diagrams, see page 3/148.
For accessories, see page 3/42. For technical data, see page 3/122. For dimension drawings, see page 3/218.
For further voltages, see page 3/37. For description, see page 3/28. 1) Size S00:
For accessories, see page 3/41. For int. circuit diagrams, see page 3/148. Coil voltage tolerance
For spare parts, see page 3/62. For dimension drawings, see page 3/223. at 50 Hz: 0.8 ... 1.1 x Us
at 60 Hz: 0.85 ... 1.1 x Us
For technical data, see page 3/130.
2) Required conductor cross-section 10 mm2.
For further voltages, see page 3/37. 1) Required conductor cross-section 10 mm2.
For accessories, see page 3/41.
For spare parts, see page 3/62.
For technical data, see page 3/130.
For description, see page 3/28.
For int. circuit diagrams, see page 3/148.
For dimension drawings, see page 3/223.
Size S0
25 11 40/35 3) 24 V, 50 Hz C 3RT15 26-1AB00 – 0.36
110 V, 50 Hz } 3RT15 26-1AF00 –
3RT15 1.-2 . . . .
230 V, 50 Hz } 3RT15 26-1AP00 –
Size S2
40 18.5 55/50 24 V, 50 Hz B 3RT15 35-1AB00 – 0.93
110 V, 50 Hz B 3RT15 35-1AF00 –
230 V, 50 Hz } 3RT15 35-1AP00 –
DC operation · DC solenoid system
nsb0069
Size S00
9 4 18/16 DC 24 V } 3RT15 16-1BB40 } 3RT15 16-2BB40 0.25
3RT15 26-1 . . . . DC 220 V } 3RT15 16-1BM40 } 3RT15 16-2BM40
12 5.5 22/20 DC 24 V } 3RT15 17-1BB40 } 3RT15 17-2BB40 0.25
DC 220 V } 3RT15 17-1BM40 } 3RT15 17-2BM40
Size S0
20 11 40/35 3) DC 24 V } 3RT15 26-1BB40 – 0.59
DC 220 V B 3RT15 26-1BM40 –
nsb0068
Size S2
40 18.5 55/50 DC 24 V } 3RT15 35-1BB40 – 1.56
DC 220 V C 3RT15 35-1BM40 –
For further voltages, see page 3/37. 1) For changing polarity; 3) Required conductor cross-section 10 mm2.
For accessories, see page 3/41. not suitable for reversing.
For spare parts, see page 3/62. 2) Size S00:
For technical data, see page 3/132. Coil voltage tolerance
For int. circuit diagrams, see page 3/148. at 50 Hz: 0.8 ... 1.1 x Us
at 60 Hz: 0.85 ... 1.1 x Us
For dimension drawings, see page 3/223.
Size S0
0
}
ns
3RT16 47-1A . 01
Size S3
16 - 30 28 - 50 36 - 60 48 - 84 1 NO 24 V, 50 Hz B 3RT16 47-1AB01 1.93
110 V, 50 Hz B 3RT16 47-1AF01
230 V, 50 Hz } 3RT16 47-1AP01
nsb0071
For further voltages, see page 3/37. 1) Coil voltage tolerance: 0.85 ... 1.1 x Us.
For accessories, see page 3/43. 2) For size S3: 55 °C.
For technical data, see page 3/134.
For wiring diagram, see page 3/152.
For dimension drawings, see page 3/224.