Вы находитесь на странице: 1из 5

Contactors and Contactor Assemblies

Contactors for Switching Motors or Resistive Loads (AC-1)


3TG10 miniature contactors,
hum-free
Contac tors and Contactor Assemblies

Selection and ordering data

Ratings Main Rated control DT Order No. Weight Pack.


Utilization category contacts supply voltage Us approx.
AC-1 AC-2 and AC-3
Switching resistive load
at 55 °C
Opera- Ratings of Opera- Ratings of Design
tional three-phase tional three-phase
current Ie loads at current Ie motors at

Ns2sym02
ns2sym01
at 400 V 50 Hz 400 V at 400 V 1) 50 Hz 400 V
A kW A kW NO NC PG 101 1 unit kg Units
With screw connections
for screwing and snapping onto 35 mm standard mounting rail
AC operation
3TG10 ..-0 20 13 8.4 4 4 – 230 V, 45 ... 450 Hz } 3TG10 10-0AL2 0.15 10
110 V, 45 ... 450 Hz } 3TG10 10-0AG2
24 V, 45 ... 450 Hz } 3TG10 10-0AC2

3 1 230 V, 45 ... 450 Hz } 3TG10 01-0AL2 0.15 10


110 V, 45 ... 450 Hz A 3TG10 01-0AG2
24 V, 45 ... 450 Hz } 3TG10 01-0AC2

DC operation
20 13 8.4 4 4 – DC 24 V } 3TG10 10-0BB4 0.15 10
nsb0124 3 1 DC 24 V } 3TG10 01-0BB4
With tab connectors 6.3 x 0.8 mm
for screwing and snapping onto 35 mm standard mounting rail
AC operation
3TG10 ..-1 16 10 8.4 4 4 – 230 V, 45 ... 450 Hz } 3TG10 10-1AL2 0.14 10
110 V, 45 ... 450 Hz A 3TG10 10-1AG2
24 V, 45 ... 450 Hz A 3TG10 10-1AC2

3 1 230 V, 45 ... 450 Hz } 3TG10 01-1AL2 0.14 10


110 V, 45 ... 450 Hz A 3TG10 01-1AG2
24 V, 45 ... 450 Hz A 3TG10 01-1AC2

DC operation
16 10 8.4 4 4 – DC 24 V A 3TG10 10-1BB4 0.14 10
nsb0125 3 1 DC 24 V A 3TG10 01-1BB4

Accessories

For contactor Design DT Order No. Weight Pack.


approx.
Max. rated operational Max.
current Ie/AC-1 conductor
(at 55 °C) cross-sections
of contactors
Type A mm2 PG 101 1 unit kg Units
Links for paralleling (star jumpers)
3-pole, without terminal 1)
3TG10 16 – } 3RT19 16-4BA31 0.004 1
Star jumpers can be
reduced by one pole
3-pole, with terminal 1)
3TG10 40 25 } 3RT19 16-4BB31 0.013 1
4-pole, with terminal 1)
3TG10 50 25 A 3RT19 16-4BB41 0.02 1

For technical data, see page 3/179. 1) The links for paralleling can be reduced by one
For description, see page 3/200. pole.
For internal circuit diagrams, The rated operational currents are valid for each
pole.
see page 3/203. The links for paralleling are insulated.
For position of terminals, see page 3/207.
For dimension drawings, see page 3/239.

3/164 Siemens NS K · 2002


Contactors and Contactor Assemblies
Contactors for Switching Motors
3TF68 and 3TF69 vacuum contactors,
3-pole

Selection and ordering data

Size Ratings Auxiliary Rated control DT Order No. Price Weight


Utilization category contacts supply voltage Us 1) approx.
AC-1 AC-2 and AC-3 (up to 55 °C)
Opera- Opera- Ratings of three-phase Design
tional tional motors at 50 Hz and

NS2SYM01
curr. Ie curr. Ie

Ns2sym02
(at 4°C) at 400 V 230 V 400 V 500 V 690 V 1000 V
A A kW kW kW kW kW NO NC PG 101 1 unit kg
AC operation 2) 3)
Auxiliary and control conductors: screw connections
Main conductor: bar connections
3TF68 14 700 630 200 335 434 600 – 4 4 200-240 V, 50/60 Hz } 3TF68 44-0CM7 15
110-132 V, 50/60 Hz } 3TF68 44-0CF7

700 630 200 335 434 600 600 4 4 200-240 V, 50/60 Hz } 3TF68 44-8CM7 15.5
110-132 V, 50/60 Hz B 3TF68 44-8CF7

910 820 260 450 600 800 – 4 4 200-240 V, 50/60 Hz } 3TF69 44-0CM7 19
110-132 V, 50/60 Hz } 3TF69 44-0CF7

910 820 260 450 600 800 800 4 4 200-240 V, 50/60 Hz C 3TF69 44-8CM7 19.5
nsb0128 110-132 V, 50/60 Hz C 3TF69 44-8CF7
DC operation · DC economy circuit
Auxiliary and control conductors: screw connections
Main conductor: bar connections
14 700 630 200 335 434 600 – 3 3 DC 24 V C 3TF68 33-1DB4 16.9
700 630 200 335 434 600 600 3 3 DC 24 V C 3TF68 33-8DB4 16.9
910 820 260 450 600 800 – 3 3 DC 24 V C 3TF69 33-1DB4 20.9
910 820 260 450 600 800 800 3 3 DC 24 V C 3TF69 33-8DB4 20.9

Reversing contactors included in delivery: 3TC44 17-4A..

3TB50 to 3TB56 contactors


3-pole, with DC solenoid system

Selection and ordering data

Size Ratings Auxiliary Rated control DT Order No. Price Weight


Utilization category contacts supply voltage Us 1) approx.
AC-1 AC-2 and AC-3 (up to 55 °C)
Opera- Opera- Ratings of three-phase Design
tional tional motors at 50 Hz and
curr. Ie curr. Ie
(at 40°C) at 400 V 230 V 400 V 500 V 690 V
A A kW kW kW kW NO NC PG 101 1 unit kg
DC operation · DC solenoid system
3TB50 Auxiliary and control conductors: screw connections
Main conductor: bar connections
6 170 110 37 55 75 90 2 2 DC 24 V } 3TB50 17-0BB4 4

8 230 170 55 90 110 132 2 2 DC 24 V } 3TB52 17-0BB4 6.8

10 325 250 75 132 160 200 2 2 DC 24 V B 3TB54 17-0BB4 12.5

12 425 400 115 200 255 355 2 2 DC 24 V C 3TB56 17-0BB4 19.2

NSB0619g

For accessories, see page 3/172. 1) For further voltages, see page 3/171. this protective circuitry is not required. It might be
For spare parts, see page 3/174. 2) Surge suppression integrated: damaged by voltage peaks and harmonics genera-
For technical data, see page 3/179. fitted with varistor. ted, possibly followed by phase-to-phase short-
3) For EMC, see description on page 3/199. circuits.
For description, see page 3/199. Optionally, therefore, the contactors can be supp-
For internal circuit diagrams, 3TF68/69 vacuum contactors are supplied with lied without integrated surge suppression.
see page 3/203, 3/204. integrated surge suppression for the main conduc- No additional charge is made.
For position of terminals, see page 3/207. ting paths (for description, see page 3/199). In ope- In this case the Order No. must be supplemented
For dimension drawings, see page 3/240. ration in circuits with DC choppers, frequency with "-Z" and the order code "A02".
converters, variable-speed drives, for example,
For recyclable packaging, see Part 17.

Siemens NS K · 2002 3/165


Contactors and Contactor Assemblies
Contactor Assemblies for Switching Motors
3TD68 contactor assemblies
for reversing

Selection and ordering data

Size Ratings Auxiliary Rated control DT Order No. Price Weight


AC-3 utilization category contacts supply voltage Us 1) approx.
per direc-
tion of
rotation
Opera- Ratings of Design
tional three-phase motors at 50 Hz and
curr. Ie
at 400 V 230 V 400 V 500 V 690 V 1000 V
A kW kW kW kW kW NO NC PG 101 1 unit kg
Complete 3TF contactor assemblies
AC operation
14 630 200 335 434 600 – 4 4 200-240 V, 50/60 Hz D 3TD68 04-2CM7 41

For motor protection, overload relays for individual mounting must be ordered
separately according to Part 4.

3TE contactor assemblies


for star-delta starting

Selection and ordering data

Size Ratings Rated control DT Order No. Price Weight


AC-3 utilization category supply voltage Us 1) approx.
Opera- Ratings of three-phase motors
tional at 50 Hz and
curr. Ie
at 400 V 230 V 400 V 500 V 690 V 1000 V
A kW kW kW kW kW PG 101 1 unit kg
Complete 3TF contactor assemblies, dead interval of up to 10 s on reversing
AC operation
Without main conducting path connection between line and delta contactors

14 1090 315 630 800 1000 – 230/220 V, 50 Hz } 3TE68 04-5CP0 54

For motor protection, overload relays for individual mounting must be ordered
separately according to Part 4.

For technical data, see page 3/179. 1) For further voltages, see page 3/171.
For description, see page 3/200.
For circuit diagrams, see page 3/204.
For dimension drawings, see page 3/242.

3/166 Siemens NS K · 2002


Contactors and Contactor Assemblies
Contactors for Special Applications
3TK1 contactors, 4-pole (4 NO),
for switching resistive loads (AC-1)

Selection and ordering data

Ratings Auxiliary con- Rated control DT Order No. Price Weight


AC-1 utilization category tacts supply voltage Us approx.

Operational Ratings of Design


current Ie three-phase loads
up to 690 V (p.f. = 0.95) at
(at 40 °C) 230 V 400 V 690 V 1000 V
A kW kW kW kW NO NC PG 101 1 unit kg
AC operation
Screw connection
Screw mounting
3TK13 200 75 130 225 205 2 2 220-230 V, 50 Hz } 3TK10 42-0AP0 4.4
230-240 V, 50 Hz } 3TK10 42-0AU0
110/120 V, 50/60 Hz } 3TK10 42-0AF0
24 V, 50 Hz } 3TK10 42-0AB0

250 90 165 280 200 2 2 220-230 V, 50 Hz } 3TK11 42-0AP0 4.4


230-240 V, 50 Hz } 3TK11 42-0AU0
110/120 V, 50/60 Hz } 3TK11 42-0AF0
24 V, 50 Hz } 3TK11 42-0AB0

300 110 195 340 325 2 2 220-230 V, 50 Hz } 3TK12 42-0AP0 6.7


230-240 V, 50 Hz } 3TK12 42-0AU0
nsb0136 110/120 V, 50/60 Hz } 3TK12 42-0AF0
24 V, 50 Hz } 3TK12 42-0AB0

350 130 230 395 370 2 2 220-230 V, 50 Hz } 3TK13 42-0AP0 6.7


230-240 V, 50 Hz } 3TK13 42-0AU0
110/120 V, 50/60 Hz } 3TK13 42-0AF0
24 V, 50 Hz } 3TK13 42-0AB0

550 205 360 620 510 2 2 220-230 V, 50 Hz 1) } 3TK14 42-0AP0 17.2


230-240 V, 50 Hz } 3TK14 42-0AU0
110/120 V, 50/60 Hz } 3TK14 42-0AF0

800 300 525 905 575 2 2 220-230 V, 50 Hz 1) } 3TK15 42-0AP0 17.2


230-240 V, 50 Hz D 3TK15 42-0AU0
110/120 V, 50/60 Hz } 3TK15 42-0AF0

1000 375 655 1135 – 2 2 220-230 V, 50 Hz 1) } 3TK17 42-0AP0 18.0


230-240 V, 50 Hz } 3TK17 42-0AU0
110/120 V, 50/60 Hz } 3TK17 42-0AF0

For accessories and spare parts, 1) At 60 Hz: 240 V.


see page 3/176.
For technical data, see page 3/179, 3/194.
For description, see page 3/201.
For internal circuit diagrams,
see page 3/205.
For position of terminals, see page 3/208.
For dimension drawings, see page 3/243.

Siemens NS K · 2002 3/167


Contactors and Contactor Assemblies
Contactors for Special Applications
3TC contactors
for switching DC voltage

Selection and ordering data

Size Ratings Auxiliary Rated control DT Order No. Price Weight


DC-3 and DC-5 utilization categories 1) contacts supply voltage approx.
2) Us
Opera- Ratings of Design
tional DC motors at
curr. Ie 6)
110 V 220 V 440 V 600 V 750 V 1200 V 1500 V

A kW kW kW kW kW kW kW NO NC PG 101 1 unit kg
3TC44 to 3TC56 2-pole contactors · operational current Ie up to 440 V
3TC44 DC operation · for screwing and snapping onto 35 mm standard mounting rail
2 32 2.5 5 9 9 4 – – 2 2 DC 24 V } 3TC44 17-0AB4 1.1
DC 110 V } 3TC44 17-0AF4
DC 220 V } 3TC44 17-0AM4
DC operation · screw mounting
nsb0137 4 75 6.5 13 27 38 45 – – 2 2 DC 24 V } 3TC48 17-0AB4 4.0
DC 110 V } 3TC48 17-0AF4
3TC48 DC 220 V } 3TC48 17-0AM4

8 220 3) 20 41 82 110 110 – – 2 2 DC 24 V } 3TC52 17-0AB4 8.7


DC 110 V } 3TC52 17-0AF4
DC 220 V } 3TC52 17-0AM4

12 400 35 70 140 200 250 – – 2 2 DC 24 V C 3TC56 17-0AB4 19.5


DC 110 V C 3TC56 17-0AF4
DC 220 V C 3TC56 17-0AM4
nsb0138 AC operation · for screwing and snapping onto 35 mm standard mounting rail
3TC52 2 32 2.5 5 9 9 4 – – 2 2 230/220 V 4), 50 Hz } 3TC44 17-0BP0 0.7
110 V, 50 Hz } 3TC44 17-0BF0
AC operation · screw mounting
4 75 6.5 13 27 38 45 – – 2 2 230/220 V 4), 50 Hz } 3TC48 17-0BP0 3.0
110 V, 50 Hz } 3TC48 17-0BF0

8 220 3) 20 41 82 110 110 – – 2 2 230/220 V 4), 50 Hz } 3TC52 17-0BP0 7.2


110 V, 50 Hz } 3TC52 17-0BF0
nsb0139

12 400 35 70 140 200 250 – – 2 2 230/220 V 4), 50 Hz } 3TC56 17-0BP0 12.3


110 V, 50 Hz C 3TC56 17-0BF0
3TC74 single-pole contactors · operational current Ie up to 750 V
3TC74 DC operation
12 400 35 70 140 200 250 – – 4 4 DC 24 V } 3TC74 14-0EB 9.8
DC 110 V B 3TC74 14-0EF
AC operation
12 400 35 70 140 200 250 – – 4 4 230/220 V 5), C 3TC74 14-1CM 9.8
50 Hz

nsb0140
3TC78 2-pole contactors · operational current Ie up to 1500 V
3TC78 DC operation
12 400 35 70 140 200 250 400 500 4 4 DC 24 V C 3TC78 14-0EB 20
DC 110 V C 3TC78 14-0EF
AC operation
12 400 35 70 140 200 250 400 500 4 4 230/220 V 5), C 3TC78 14-1CM 20
50 Hz
For further rated control supply voltages Us see page 3/171.

nsb0141

For accessories, see page 3/172. 1) For the permissible load for the DC-1 utilization 6) The following rated operational currents are per-
For spare parts, see page 3/177. category, see page 3/197. mitted for plugging with 3TC44 to 3TC56 con-
For technical data, see page 3/179. 2) The auxiliary switch complement cannot be alte- tactors:
For description, see page 3/201. red on DC-operated contactors. Contactor Rated operational voltage
For internal circuit diagrams, 3) At > 600 V: Ie = 170 A. Type 110 V, 220 V 440 V
see page 3/206. 4) Coil voltage tolerance at 220 V:
0.85 to 1.15 x Us. 3TC44 32 A 7A
For position of terminals, see page 3/208. 3TC48 75 A 75 A
For dimension drawings, see page 3/245. 5) Upper tolerance range limit at 230 V: 3TC52 170 A 170 A
1.14 x Us. 3TC56 400 A 400 A

3/168 Siemens NS K · 2002