Вы находитесь на странице: 1из 16

HITACHI

Ultra Long Life


AVRLA Lead Acid Batteries
for Energy Storage Solutions
HITACHI
AVRLA Lead Acid Batteries
The flexible power storage solution
LL-AN / LL-AS longlife batteries designed for energy storage with daily charge- / discharge
cycle.
For domestic and industrial applications

Outstanding cycle life at 70% DoD


LL50AN12: 3,000 cylces
LL400AN12: 3,000 cycles
LL1500AS8: 4,500 cycles

Up to 17 years of operation

Proven and secure technology

Fully recyclable

Maintenance free

Optimized for PV systems

Easy to install

Track record of more than 40 MWh installed capacity since 2000

2
For sun, wind and other renewable energies

LL50AN12 LL400AN12 LL1500AS8

Capacity (C10) 50 Ah 400 Ah 1,500 Ah

Voltage 12 V 12 V 8V

Nominal energy (C10) 600 Wh 4,800 Wh 12,000 Wh

220 kg 485 kg
Weight 27 kg
(32 kg / cell) (115 kg / cell)

Dimensions
Height 350 mm 265 mm 473 mm
Width 175 mm 369 mm 506 mm
Length 166 mm 1,178 mm 871 mm

Cycle life with DoD 70% 3,000 3,000 4,500

DoD 70% max. 70% max. 70% max.

3
LL-AN series
Domestic and small industrial solutions

4
LL-AN series
Technical data

LL50AN12 LL400AN12 Condition

Rated Voltage 12 VDC 12 VDC

Rated Capacity @ 25°C 50 Ah (C10) 400 Ah (C10) 10.8 VDC / 1.8 V per cell

Weight: 27 kg 220 kg (32 kg / cell)

Plastic Case / Cover UL94V-0 UK94V-0

Internal Resistance 6 mΩ / cell 0.33 mΩ / cell approx.

Terminal Type Bolt M6 Bolt M6

Temperatures
Charge 0 - 40 °C 0 - 40 °C
Discharge -15 - 40 °C -15 - 40 °C
Storage -15 - 40 °C -15 - 40 °C

Charging Voltage 14.52 VDC 14.52 VDC 25 °C


(2.42 V / cell) (2.42 V / cell)

14.70 VDC 14.70 VDC 20 °C


(2.45 V / cell) (2.45 V / cell)

Range 15.3 - 14.1 VDC 15.3 - 14.1 VDC 0 °C - 40 °C

Temperature Coefficient: -30 mV / °C -5 mV / °C per cell at 14.52 V; 25 °C

Service Life @ 25°C With 70% DoD


Cycles 3,000 3,000 and controlled
Years 10 -12 10 -12 charge / discharge

Horizontal Horizontal Very important for long


Mounting Orientation
(Terminals sideways) (Terminals sideways) service life

Dimensions
LL50AN12 LL400AN12
369 mm 1,178 mm

265 mm

350 mm 175 mm

166
mm

5
LL-AN series
Discharge Capacity Ratings
LL50AN12
Ambient Effective Effective Effective
Discharge Nominal
Tempera- C-Rate Capacity Discharge Discharge
Current Capacity
ture DoD 70% Energy Time
25°C 0.05 C 2.5 A 55 Ah 38.5 Ah 460 Wh 15.4 h

25°C 0.10 C 5.0 A 50 Ah 35.0 Ah 416 Wh 7.0 h

25°C 0.17 C 8.5 A 43 Ah 30.1 Ah 361 Wh 3.54 h

25°C 0.25 C 12.5 A 38 Ah 26.6 Ah 319 Wh 2.13 h

25°C 0.60 C 30.0 A 30 Ah 21.0 Ah 252 Wh 0.7 h

5°C 0.05 C 2.5 A 50 Ah 35.0 Ah 420 Wh 14.0 h


5°C 0.10 C 5.0 A 45 Ah 31.5 Ah 378 Wh 6.3 h
5°C 0.17 C 8.5 A 39 Ah 27.3 Ah 328 Wh 3.21 h
5°C 0.25 C 12.5 A 35 Ah 24.5 Ah 294 Wh 1.96 h
5°C 0.60 C 30.0 A 27 Ah 18.9 Ah 227 Wh 0.63 h

LL400AN12
Ambient Effective Effective Effective
Discharge Nominal
Tempera- C-Rate Capacity Discharge Discharge
Current Capacity
ture DoD 70% Energy Time
25°C 0.05 C 20 A 440 Ah 308 Ah 3,696 Wh 15.4 h

25°C 0.10 C 40 A 400 Ah 280 Ah 3,360 Wh 7.0 h

25°C 0.17 C 68 A 344 Ah 241 Ah 2,892 Wh 3.54 h

25°C 0.25 C 100 A 304 Ah 213 Ah 2,556 Wh 2.13 h

25°C 0.60 C 240 A 240 Ah 168 Ah 2,016 Wh 0.7 h

5°C 0.05 C 20 A 400 Ah 280 Ah 3,360 Wh 14 h


5°C 0.10 C 40 A 364 Ah 255 Ah 3,060 Wh 6.38 h
5°C 0.17 C 68 A 313 Ah 219 Ah 2,628 Wh 3.2 h
5°C 0.25 C 100 A 277 Ah 194 Ah 2,328 Wh 1.94 h
5°C 0.60 C 240 A 218 Ah 153 Ah 1,836 Wh 0.64 h

6
LL-AN series
Discharge Current vs. Discharge Time
LL50AN12

14.0 h

12.0 h

10.0 h

8.0 h

6.0 h

4.0 h

2.0 h

0.0 h
2.5 A 5.0 A 8.5 A 12.5 A 30.0 A

Optimal discharge current is 5 A or less. This will result in discharge times of 7 hours or more.
DoD max. is 70 %. Ambient temperature: 25°C.

! Do not discharge the battery below 10.2 VDC


The maximum discharge current is 30 A

LL400AN12

14.0 h

12.0 h

10.0 h

8.0 h

6.0 h

4.0 h

2.0 h

0.0 h
20 A 40 A 68 A 100 A 240 A

Optimal discharge current is 40 A or less. This will result in discharge times of 7 hours or more.
DoD max. is 70 %. Ambient temperature: 25°C.

! Do not discharge the battery below 10.2 VDC


The maximum discharge current is 240 A

7
LL-AN series
Charge Characteristic
Full Charge for daily charging
LL- AN series
2.45 V

2.40 V

2.35 V
Charging Voltage

2.30 V Duration to keep at


2.42 V / cell
(14.52 V / 25°C)
2.25 V

2.20 V

2.15 V

2.10 V
0.0 h 1.0 h 2.0 h 3.0 h 4.0 h 5.0 h 6.0 h 7.0 h 8.0 h
Charging Time

Charging current should be set between 5 A and 10 A (for LL50AN12) / 40 A and 80 A (for LL400AN12)

Equalizing Charge every 14 days


LL-AN series
2.45 V

2.40 V

2.35 V
Charging Voltage

2.30 V 13.0 h
Duration to keep at 2.42 V / cell
2.25 V (14.52 V / 25°C)

2.20 V

2.15 V

2.10 V
0.0 h 2.0 h 4.0 h 6.0 h 8.0 h 10.0 h 12.0 h 14.0 h 16.0 h
Charging Time

Charging current should be set between 5 A and 10 A (for LL50AN12) / 40 A and 80 A (for LL400AN12)

8
LL-AN series
Lifetime Characteristic

LL-AN series

8,000

7,000
Lifetime (cycles)

6,000

5,000

4,000

3,000

2,000
30% 40% 50% 60% 70%
Depth of Discharge

Discharge Current 5.0 A (LL50AN12) / 40.0 A (LL400AN12)


Charging Method Multistep charging
Temperature 25°C
Charge / Discharge 102%
Orientation Terminal sideways

9
LL-AN series
Example systems

2 in series 2 in series
Configurations 24 V Systems 2 in series
2 times parallel 3 times parallel

Number of batteries 2 4 6
Nominal Energy (C10) 1.2 kWh 2.4 kWh 3.6 kWh
LL50AN12

Net Energy (70% DoD) 0.84 kWh 1.68 kWh 2.52 kWh
Peak Charge Current 10 A 20 A 30 A
Peak Discharge Current 20 A 40 A 60 A
Weight 54 kg 108 kg 162 kg
Cycle with 70% DoD 3,000 3,000 3,000
Estimated life 10 - 12 years 10 - 12 years 10 - 12 years
Energy output over life time 2,550 kWh 5,100 kWh 7,650 kWh
Number of batteries 2 4 6
Nominal Energy (C10) 9.6 kWh 19.2 kWh 28.8 kWh
LL400AN12

Net Energy (70% DoD) 6.72 kWh 13.44 kWh 20.16 kWh
Peak Charge Current 80 A 160 A 240 A
Peak Discharge Current 160 A 320 A 480 A
Weight 440 kg 880 kg 1,320 kg
Cycle with 70% DoD 3,000 3,000 3,000
Estimated life 10 - 12 years 10 - 12 years 10 - 12 years
Energy output over life time 20,160 kWh 40,320 kWh 60,480 kWh

4 in series 4 in series
Configurations 48 V Systems 4 in series
2 times parallel 3 times parallel

Number of batteries 4 8 12
Nominal Energy (C10) 2.4 kWh 4.8 kWh 7.2 kWh
LL50AN12

Net Energy (70% DoD) 1.68 kWh 3.36 kWh 5.04 kWh
Peak Charge Current 10 A 20 A 30 A
Peak Discharge Current 20 A 40 A 60 A
Weight 108 kg 216 kg 324 kg
Cycle with 70% DoD 3,000 3,000 3,000
Estimated life 10 - 12 years 10 - 12 years 10 - 12 years
Energy output over life time 5,100 kWh 10,200 kWh 15,300 kWh
Number of batteries 4 8 12
Nominal Energy (C10) 19.2 kWh 38.4 kWh 57.6 kWh
LL400AN12

Net Energy (70% DoD) 13.44 kWh 26.88 kWh 40.32 kWh
Peak Charge Current 80 A 160 A 240 A
Peak Discharge Current 160 A 320 A 480 A
Weight 880 kg 1,760 kg 2,640 kg
Cycle with 70% DoD 3,000 3,000 3,000
Estimated life 10 - 12 years 10 - 12 years 10 - 12 years
Energy output over life time 40,320 kWh 80,640 kWh 120,960 kWh

10
LL1500AS8
Industrial solutions and island grids

11
LL1500AS8
Technical data

LL1500AS8 Condition

Rated Voltage 8 VDC

Rated Capacity @ 25°C 1,500 Ah (C10) 7.2 VDC (1.8 VDC / cell)

Weight: 485 kg (115 kg / cell)

Plastic Case / Cover UL94V-0

Internal Resistance 0.3 mΩ / cell approx.

Terminal Type Bolt M6

Temperatures
Charge 0 - 40 °C
Discharge -15 - 40 °C
Storage -15 - 40 °C

Charging Voltage 2.42 V / cell 25 °C

2.45 V / cell 20 °C

Range 10.2 - 9.4 VDC 0 °C - 40 °C

Temperature Coefficient: -30 mV / °C at 14.52 V; 25 °C

Service Life @ 25°C


With 70% DoD and controlled
Cycles 4,500 charge / discharge
Years 15 -18

Horizontal
Mounting Orientation Very important for long service life
(Terminals sideways)

Dimensions
LL1500AS8
506 mm 871 mm

473 mm

12
LL1500AS8
Discharge Characteristic
Discharge Capacity Ratings
Ambient Effective Effective Effective
Discharge Nominal
Tempera- C-Rate Capacity Discharge Discharge
Current Capacity
ture DoD 70% Energy Time

25°C 0.10 C 150 A 1,500 Ah 1,050 Ah 8,400 Wh 7.0 h


25°C 0.16 C 240 A 1,200 Ah 840 Ah 6,720 Wh 3.5 h
25°C 0.23 C 345 A 1,050 Ah 735 Ah 5,880 Wh 2.1 h
25°C 0.40 C 600 A 600 Ah 420 Ah 3,360 Wh 0.7 h

5°C 0.10 C 150 A 1,250 Ah 875 Ah 7,000 Wh 5.8 h


5°C 0.16 C 240 A 1,000 Ah 700 Ah 5,590 Wh 2.9 h
5°C 0.23 C 345 A 833 Ah 583 Ah 4,660 Wh 1.7 h
5°C 0.40 C 600 A 480 Ah 336 Ah 2,688 Wh 0.6 h

Discharge Current vs Discharge Time

7.0 h

6.0 h

5.0 h

4.0 h

3.0 h

2.0 h

1.0 h

0.0 h
150 A 240 A 345 A 600 A

Optimal discharge current is 150 A or less. This will result in discharge times of 7 hours or more.
DoD max. is 70 %. Ambient temperature: 25°C.

! Do not discharge the battery below 6.8 VDC


The maximum discharge current is 600 A

13
LL1500AS8
Lifetime Characteristic / Example systems
8,000

7,000
Lifetime (cycles)

6,000

5,000

4,000

3,000

2,000
30% 40% 50% 60% 70%
Depth of Discharge
Discharge Current 150.0 A
Charging Method Multistep charging
Temperature 25°C
Charge / Discharge 102%
Orientation Terminal sideways

3 in series 3 in series
Configurations 24 V Systems 3 in series
2 times parallel 3 times parallel

Number of batteries 3 6 9
Nominal Energy (C10) 36.0 kWh 72.0 kWh 108.0 kWh
LL1500AS8

Net Energy (70% DoD) 25.2 kWh 50.4 kWh 75.6 kWh
Peak Charge Current 300 A 600 A 900 A
Peak Discharge Current 600 A 1,200 A 1,800 A
Weight 1,455 kg 2,910 kg 4,365 kg
Cycle with 70% DoD 4,500 4,500 4,500
Estimated life 15 - 18 years 15 - 18 years 15 - 18 years
Energy output over life time 113,400 kWh 226,800 kWh 340,200 kWh

6 in series 6 in series
Configurations 48 V Systems 6 in series
2 times parallel 3 times parallel

Number of batteries 6 12 18
Nominal Energy (C10) 72.0 kWh 144.0 kWh 216.0 kWh
LL1500AS8

Net Energy (70% DoD) 50.4 kWh 100.8 kWh 151.2 kWh
Peak Charge Current 300 A 600 A 900 A
Peak Discharge Current 600 A 1,200 A 1,800 A
Weight 2,910 kg 5,820 kg 8,730 kg
Cycle with 70% DoD 4,500 4,500 4,500
Estimated life 15 - 18 years 15 - 18 years 15 - 18 years
Energy output over life time 226,800 kWh 453,600 kWh 680,400 kWh

14
LL1500AS8
Charge Characteristic
Full Charge for daily charging
LL1500AS8
2.45 V

2.40 V

2.35 V
Charging Voltage

2.30 V Duration to keep at


2.42 V / cell
(9.68 V / 25°C)
2.25 V

2.20 V

2.15 V

2.10 V
0.0 h 1.0 h 2.0 h 3.0 h 4.0 h 5.0 h 6.0 h 7.0 h 8.0 h
Charging Time

Charging current should be set between 150 A and 300 A.

Equalizing Charge every 14 days


LL1500AS8
2.45 V

2.40 V

2.35 V
Charging Voltage

2.30 V 13.0 h
Duration to keep at 2.42 V / cell
2.25 V (9.68 V / 25°C)

2.20 V

2.15 V

2.10 V
0.0 h 2.0 h 4.0 h 6.0 h 8.0 h 10.0 h 12.0 h 14.0 h 16.0 h
Charging Time

Charging current should be set between 150 A and 300 A.

15
HID EuropE
EnErgy SolutIonS

HID Europe is an engineering company focused on high quality energy storage. We


provide bespoke solutions for energy producers/utilities, communities and all methods
of renewable energy implementation.

We only use proven products and components that guarantee sustainability, and state of
the art environmental responsibility.

the relationship with our customers and partners is built on trust and long-term partner-
ships. We promise the best individual service and support with every product we sell.

HeAD OFFICe SALeS OFFICe

HID-Europe gmbH + Co. Kg HID-Europe gmbH + Co. Kg


Diekstraat 13 Adolf-Dembach-Str. 12
D - 25870 norderfriedrichskoog / Germany D - 47829 Krefeld / Germany

e-mail info@hid-europe.de e-mail info@hid-europe.de


phone +49 2151 48449-00 phone +49 2151 48449-00
fax +49 2151 48449-99 fax +49 2151 48449-99

www.hid-europe.de
www.energycontainer.com

Вам также может понравиться