Вы находитесь на странице: 1из 5

HRC/CHK-LST-GT-ENG

Check List for the Main Geotechnical Consultant

S Item References
r.
1.N Property Details To be Filled by Client
o.

Project Name To be Filled by Client

Project Address To be Filled by Client

2. Detail of the Structure Includes height abutting the boundries of the


plot
North side To be Filled by Client
West side To be Filled by Client
South Side To be Filled by Client
East Side To be Filled by Client
No. of Basement To be Filled by Client
Height of each basement To be Filled by Client
3. Soil Investigation Details

Boring methods Double tube for boring


No. of Bore holes Total – 12 Boreholes
7 Borehole (BH-1 to BH-7) within Tower Area

Spacing of bore holes Approx. 15m to 25m


Terminated Depth of Boreholes BH-1, BH-4, BH-6, BH-7 - 25.0m Depth
BH-2 - 20.0m Depth
BH-3 – 21.0m Depth
BH-5 – 25.5m Depth
GWL (m) Approx. 5.8m to 6.5m Below Ground
Testing Laboratory Not NABL Accredited
4. Foundation
Type of proposed foundation
Solid Raft

Depth of Footing /raft


pile termination
Raft Depth = 2500 mm + 500mm (pedestal)

Load Calculation / Maximum Pressure from SAFE outputs - 164


contact pressure t/m2
Maximum Pressure from Plaxis Outputs – 168
t/m2
SBC estimated 300 t/m2
Sub-grade Elastic Modulus 1,70,000 t/m3
Settlement/ 12mm.
Differential settlement

Uniform /Differential settlement <L/400, Within permissible settlement


4.1 Raft Foundation
Bottom level of raft -17.45m from Ground level --- For Tower
area.

-15.95m from Ground level --- For Non-


Tower area.

Minimum clearance between


outermost basement retaining To be filled by Client
wall and compound wall
Size 106m X 48m
Thickness 2500 mm + 500mm (pedestal) -- For
Tower Area

1000mm ---- For Non Tower Area


Depth To be filled by structural consultant
Modulus of Subgrade Reaction
Zoned Spring Constant
Based on FE analysis
Modelling of Soil for raft
foundation Yes

Anchors details Rock anchors of 45Ton capacity will be


provided at 2.0m c/c.
4.2 Pile Raft NA
Sharing of load by raft and piles NA
Pile cap rest on strata NA

Pile raft design NA


Foundation settlement and NA
pressure measurement
4.3 Pile Foundation NA
Type, diameter, spacing NA
Socket depth NA
Foundation settlement and NA
pressure measurement
4.4 Lateral load analysis NA
Pile load test NA
Initial
Routine
Any other Field test / conducted
/ recommended
4.5 Uplift capacity of foundation
Based on wind pressure No uplift pressure encountered. Refer
Maximum & Minimum Base pressure sheet
provided as per safe analysis results.
Based on GWL Refer calculations provided for Non Tower
area.
Based on earthquake No uplift pressure encountered. Refer
Maximum & Minimum Base pressure sheet
provided as per safe analysis results.
If rock anchors are used are they To be filled by structural consultant
grouted after installation and
stressing? Or Passive anchor
Whether pressure release pipes To be filled by structural consultant
have been used?
5 Shoring Arrangement
Has a shoring system been Yes
installed
Type (touching piles C/C spacing Touching Piles
Secent pile / diaphragm wall)
Size and Depth 300mm Dia @ 400mm C/C (Micro-Piles)
Achors if required Yes

GWL -

7 Retaining wall ( If any) To be filled by structural consultant


8 Submission of final report In advance to authority should reach the
minimum 5 days before

Вам также может понравиться