Technical Specifications

Type Pointek CLS 100 Pointek CLS 200 Pointek CLS 300
Probe
Process connection NPT / BSPT NPT / BSPT / JIS / San. NPT / BSPT / JIS
Connection size 3/4 – 1 inch 3/4 – 1 – 1- 1/4 – 1-1/2 inch 3/4 – 1 – 1-1/4 – 1-1/2 inch
Wetted parts AISI 316L / PVDF AISI 316L / PPS / PVDF*** AISI 316L / PFA / Ceramics*
Min. probe length (mm/inch)
- rod version 100/4 100/4 350/14
- rope/cable version — 350/14 500/20
Max. probe length (mm/inch)
- rod 100/4 5500/216 1000/40
- rope — 35000/1378 25000/985
Max. tensile force (kg/lbs) — 180/296 1900/4188
Pressure range (bar/PSI)** FV-10/146 FV- 25/365 (10/146) FV-35/511
- High pressure version (optional) — — FV-100/1460
Temperature range °C (°F)
- Standard-version -40/100 (-40/212) -40/125 (-40/257) -40/200 (-40/392)
- HT- version — — -40/400 (-40/752)
Min. dielectric constant (εr) 1.5 1.5 1.5
Measurement frequency 5.5 mHz max. 5.0 mHz max. 600 kHz max.
Switch point repeatability 2 mm / 0.08” 2 mm / 0.08” product dependent
Hysteresis 2 mm / 0.08” 2 mm / 0.08” product dependent
Electrostatic Discharge Protection according to CE according to CE according to CE, additional 55 kV on the probe
Enclosure version ABS impact proof Aluminum Aluminum
Epoxy coated — yes yes
NEMA / Type / IP-rating 4 / 4X / IP65 4 / 4X / IP65 4 / 4X / IP65
Cable inlet 1 pc. 1/2“ NPT 2 pcs. 1/2“ NPT 2 pcs. 1/2“ NPT
Cable version (22 AWG) 4-conductor cable — —
Polyester Cable length 1.0 m / 3.3 ft — —
Power supply
Universal — 12 – 250 Vac/dc 12 – 250 Vac/dc
24 Vdc 10-30 Vdc — —
Max. Power consumption 0.6VA / 0.6 Watt 2VA / 2 Watt 2VA / 2 Watt
Wiring connections max. 2.5 mm2 max. 2.5 mm2 max. 2.5 mm2
Temperature range °C (°F)
- operation -40/85 (-40/185) -40/85 (-40/185) -40/85 (-40/185)
- storage -40/85 (-40/185) -40/85 (-40/185) -40/85 (-40/185)
Signal detection
Failsafe Operation high or low high or low high or low
Signal indicators (LEDs)
- power green green green
- probe adjustment yellow yellow yellow
- output states red red red
Adjustments
- time delay on/off selectable — 1 – 60 sec. 1 – 60 sec.
- sensitivity yes yes yes
Output{s}
Relay
- contact selectable NC/NO — SPST SPST
- selectable fail safe
(energized/de-energized) — yes yes
- max. contact load — 5A / 30Vdc 5A / 30Vdc
- max. contact load Cos phi =1 — 8A / 250Vac 8A / 250Vac
- max. switch capacity — 2000VA / 150 Watt 2000VA / 150 Watt
- min. contact load — 10mA / 5Vdc 10mA / 5Vdc
Solid State (NPN / PNP trans.)
- galvanically isolated output yes yes yes
- polarity sensitive no no no
- max. load 2 VA 2 VA 2 VA
- max. switch voltage 28/40 Vac/dc 250 Vac/dc 250 Vac/dc
- max. load current 100 mA 100 mA 100 mA
Current (Alarm) output
- 4/20 or 20/4 mA (2-wire) yes — —
Approvals
- Standard CE, EN 61326 CE, EN 61326 CE, EN 61326
- Cenelec / ATEX / FM / CSA IS & DIP XP & DIP XP & DIP
- Overspill protection WHG (Germany) WHG (Germany) WHG (Germany)
- Marine (ENV 1, 2 & 5) Lloyd’s Register Lloyd’s Register Lloyd’s Register

* Ceramics is applicable for the Pointek CLS 300 high temperature version
** Pressure rating is temperature dependent, contact Siemens Milltronics for the rating curves ***Optional material

For detailed drawings, wiring diagrams and further specifications on the Pointek CLS series, please consult our web site. Specifications subject to change without notice.
Teflon is a registered trademark of E.I Du Pont de Nemours and Company. Kynar is a registered trademark of Atofina Chemicals, Inc. Ryton is a registered trademark of Phillips Petroleum Company.

www.siemens-milltronics.com
7ML1996-5AT03 Printed in Canada
Reliability Beyond Measure
Pointek® Capacitance Point Level Sensors
Accurate and Reliable
Point Level Detection
Pointek CLS sensors provide accurate and
reliable level detection even in the most
challenging applications or environments.
They are field-proven performers in major
industries worldwide:
■ Chemical ■ Water and Wastewater
■ Petrochemical ■ Milling, Grain
■ Aggregate ■ Food Processing
■ Cement ■ Power Generation

A Configuration for Every Application


The modular design offers a full line of probe styles,
configurations, process connections, extensions and
approvals, giving you maximum flexibility to suit your
particular application.There’s a model to meet virtually
any application requirement.

Pointek CLS 100: Compact instrument for constricted


spaces

Pointek CLS 200: For high and low level alarms in most
applications

Pointek CLS 300: For heavy duty use in extreme


temperatures, high or low pressures, harsh chemicals,
or abrasive materials

Typical Applications
Solids: Granulates, Flour, Corn, Grain, Clinker, Gravel,
Coal, Fly-Ash, Sand, Plastic Pellets, Cement

Liquids: Water, Oil, Liquified Gas, Chemicals, Milk,


Acids, Bitumen, Caustics, Foam

Slurries: Adhesives, Pulp Stock, Glucose, Sludge,


Drilling Mud

Interfaces: Vapor Gas and Liquified Oil, Water and Oil,


Liquid and Foam
Pointek Performance Advantages
Quality Construction, Superior Performance

✔ Accurate, reliable level detection, even with changing material properties


✔ Unaffected by material build-up
✔ Broad range of lengths, mounting options and probe configurations
✔ Models available for virtually any application, including extreme temperatures,
pressures, and material loading

✔ Easy to install and calibrate; cost-effective setup using LED verification


✔ Economical – replace paddle switches, tuning forks and other switches to
reduce stocking, maintenance and replacement costs.This single technology
design can be used in a variety of applications, eliminating the need for multiple
switch technologies

✔ Quality construction, with all electronic circuits fully potted in epoxy resin for
protection against shock, vibration, humidity and condensation

✔ Connect to PLC or control system


✔ Low cost of ownership; excellent price-to-performance ratio
✔ Low maintenance, with corrosion resistant construction and no moving parts
✔ Full safety approvals include ATEX, FM, CSA, Lloyd’s Register, and WHG;
suitable for hazardous areas, marine applications and overfill protection

SensGuard Solution for Extreme Conditions SensGuard


With a SensGuard in place, Pointek CLS 100 and 200 instruments can Cover
Tank Wall
be removed for checking or for use elsewhere without interrupting the
process or emptying the vessel. Made of PPS (polyphenylene sulphide),
the SensGuard protects the probe from chemicals and abrasion. It is
available with a 3⁄4 inch NPT or 1 inch BSPT process connection. Pointek CLS100
Pointek CLS 100 Series
High Accuracy and Repeatability

Pointek CLS 100 is a 2-wire level detection


instrument specially designed for small


Impact resistant ABS
enclosure with a rigid
and constricted spaces. conduit entry

With a very short insertion length of 100 mm (4 in.)


and a minimum process connection of 3⁄4 inch, it can
be installed in tight spaces such as a pharmaceutical
small batch tank, flow pipeline system, transport
truck, or an oil lubrication pump reservoir. Compact
construction, combined with high performance and
low cost, make the Pointek CLS 100 an effective,
economical solution for these applications. It offers

Stainless steel
more performance than mechanical devices such enclosure with
integrated cable
as paddle switches or conventional capacitance
sensors, at a comparable price. It offers a current
shift (4/20 or 20/4) and solid state switch output for
direct PLC connection. Model options available:

■ Intrinsically Safe
■ Dust Ignition Proof ▲ Pointek CLS 100 is available in two NEMA 4X/IP65
■ General Purpose approved enclosure types to meet specific industrial
wiring practices.

▲ ▲
Pointek CLS 100 instruments provide high The Pointek CLS 100 does not need to penetrate this
and low level detection in a 30 cm (11.8”) plastic vessel for reliable point level detection in this
diameter fully automatic epoxy resin turbulent liquid process.
potting system.

▲ The Pointek CLS 100 is


very compact to fit in
small and constricted
spaces.
Pointek CLS 200 Series
High Performance, Many Applications

Choose from a wide range of configurations, including rigid rod,


sanitary and cable sensor models, with a selection of different
process connections, extensions and approvals. Features include:

■ Modular design with many configurations


■ Electronics housed in epoxy-coated aluminum enclosure
rated IP65/NEMA 4
■ Immune to material build-up around the
mounting section
■ Universal power supply
galvanically isolated
■ Stainless steel orTeflon®
(PFA) coated stainless steel
wetted parts, and Kynar®
(PVDF) or Ryton® (PPS) probe
body materials are chemical
resistant
■ Suitable for hazardous areas
■ Thermal isolator available for extreme temperature applications
where the electronics need to be separated from the sensing probe
■ A relay and solid state output for direct pump control, turning
the pump on when material level reaches the setpoint; a practical
solution for overfill protection

Standard Model Sanitary Models Extended Models


The standard model Sanitary versions for the Extended range (cable
is suitable for point food and pharmaceutical and rigid rod) models
level detection appli- industries feature a stan- can be used for point
cations requiring a dard sanitary tri-clamp level and interface
rigid rod. With a process connection. They detection in liquids and
short insertion meet industry require- solids. Cable extensions
length of just 100 ments for temperatures are protected by a Kynar
mm (4 in.), it max- exceeding 125°C (257°F). (PVDF) jacket, with
imizes tank capacity Wetted parts are manu- lengths up to 35 m
and can readily be factured from 316L (115 ft.) for applications
used in small stainless steel and where it is not possible
diameter pipes. Ryton (PPS) or optional to penetrate the tank
Kynar (PVDF) which are wall near the bottom.
both 3A compliant and Rigid rod lengths are
food grade safe. Units available up to 5.5 m
are designed to operate (18 ft.). An adjustable
in clean-in-place (CIP) sliding process mount
applications in the food is available to adjust the
industry. position of the sensor.
Pointek CLS 300 Series
Harsh, Heavy Duty Applications

Even in the harshest conditions, Pointek CLS 300


provides accurate, reliable level detection.
Whether the material is crushed stone, flour, petrochemicals, pulp,
foam, pellets, or oil and water in a separator, this instrument can be
readily configured for the application. It’s designed for:

■ Extreme temperatures up to 400°C (752°F)


■ High pressure (-1 to +100 bar (1460 psi)) or full vacuum
■ Low or high conductive materials
■ Abrasive materials
■ High material-loading conditions up to 1900 kgs (4200 lbs.)
■ Corrosive or volatile chemicals and hazardous areas

Modular Design for Maximum Application Flexibility


Fully potted
transmitter is
unaffected by
condensation, dust
Explosion/flame or vibration
proof epoxy
coated enclosure
with two cable
gland/conduit inlets
Thermal isolator
eliminates effect
of process
temperature

With its explosion-proof enclosure and patented


Standard probes
have PFA-coated Active-Shield technology, Pointek CLS 300 is not
active shield for Ceramic-isolated affected by changes in vapor concentration,
applications up to active shield for
highly abrasive or material build-up, dust or condensation near the
200°C (392°F)
high-temperature gland section. Its heavy duty design, large-
applications up to diameter rod and sturdy construction make it
400°C (752°F)
robust in tough conditions, but sensitive enough
High tensile strength for reliable level detection even in low dielectric,
cable/rope light materials. A built-in electrostatic discharge
(1900 kg/4188 lbs.)
with maximum
circuit allows for effective measurement on
Removable and
adjustable rod length of 25 m (82 ft.) fly-ash or plastic pellets. All wetted parts are
is removable and made of stainless steel and Teflon (PFA) or
adjustable
ceramics to provide high chemical resistance.
Butterfly plate Tensile weight
significantly improves
The modular design features a universal power
for a stable
switchpoint cable/rope supply with one universal electronics and a wide
repeatability in installation range of process connections and probe
relatively low
dielectric materials configurations, including rigid rod and flexible
(εr<4.0) cable versions.
Innovative Technology for
Performance You Can Trust
Inverse-Frequency They are easy to install and can
Technology be mounted in any position.The
switchpoint can be easily adjusted
Pointek instruments are unlike any
when required; for example, the unit
other capacitance switches on the
can be quickly calibrated to neglect
market.Their unique frequency-based
air and initiate an alarm when any
technology ensures accurate, reliable,
material contacts the tip. Setup is
and repeatable level detection that
easy with verification by three
consistently outperforms conventional
built-in LED indicators: material
devices. Other systems measure
status (probe covered/uncovered),
voltage drop or current flow and are
power status, and output status
affected by changes in material
(switch-point reached).
properties. Pointek sensors monitor
the effect of capacitance based on
frequency change. Because even Active-Shield Technology
small level changes create large
Special technology features and
changes in frequency, the result is
rugged construction of the Pointek
better resolution and accuracy.This
CLS 300 offer outstanding perform-
innovative approach to capacitance
ance in heavy duty applications with
technology provides repeatable level
extreme temperatures and pressures,
detection you can trust.
as well as corrosive or abrasive con-
ditions.The 300 series is built for
Sensitive-Tip Probes harsh applications; for that reason, the
The Pointek CLS 100 and 200 models electronics are located in the housing
incorporate a high frequency oscillator rather than the probe. Its patented
with the sensor encapsulated in the Active-Shield technology isolates the
probe tip.The sensitive tip is a very active shield portion of the probe
accurate and repeatable switchpoint. from an active measurement section
The probe is unaffected by material (the sensor).The sensor signal is
connected to the active shield portion
build-up or material changes resulting
of the probe, effectively eliminating
from humidity or moisture, unlike many
the electrical potential difference
conventional devices that can’t cope
between the shield and the measure-
with material property changes in low
ment section. As a result, the shield
dielectric materials like oil, powders, portion of the probe (near the process
grains, or flour. Pointek instruments connection) is not affected by changes
operate independently of the tank or in vapor concentration, material build-
pipe wall and do not require an up, dust or condensation.This means
external reference electrode in a non- reliable, accurate level detection, even
conductive vessel such as concrete in harsh conditions.
or plastic.They can even be mounted
outside a non-conductive (glass
or plastic) tank to detect through
the wall the presence or absence
of material.

Вам также может понравиться