Pumping Stations have been planed to be installed at the two intake locations on the
approximately 500 m apart and three other intermediate / terminal lifting station at
the prominent discharge locations of the conveyance main spreaded over a total
length of 36 KM upto the terminal lifting station at Salua from the common intake
collector wall shall be located inbetween the terminal station and common intake
point with one at Kultikri 12 KM from the common intake point at Dherachera and
The intake Pump House shall be provided at the specified locations over the river
intake well of ‘D’ shaped double compartment construction to facilitate common use
of surface / subsurface water from the single well in application with the separate
All the pumping station shall be in operation for a duration of 20 hrs. a day for
supplying the required net flow of clear water through the conveyance main
including the intermediate outflow required from the respective offtake terminal at
the lifting stations. Off take terminals have also been considered to be provided at all
The system will cause intermittent increase / reduction of flow at various sections the
conveyance main from the intake to terminals which has been taken care of by
resizing of the conveyance main/branch at the respective input / off take terminal
1. Layout of the proposed river intake Pumping Station 1 & 2 at Dherachera and Kalrui.
General:
The design of the Raw / Clear Water pumping machinery for the stations have been
carried out considering daily total requirement of net raw / clear water flow of 15
MGD plus 10% extra for wastage i.e. 3750 m 3/hr (1040 LPS) including all off-take
discharge from the inter-mediate / terminal lifting stations in order to maintain the
requisite quantum of supply at the respective terminal ends as indicated in Table A1.
These demands of clear water flow from the intake / intermediate / terminal stations
shall be met by running suitable no of pumps at the intake and intermediate / terminal
stations corresponding to the combined total discharge of the intake stations and
manner:-
1. Full working capacity of the pumps at each intake station @ 1875 m 3/hr (520
LPS)
ii) Common discharge at the down stream main leading to inter mediate
station 2 @ 3500 m3/hr (970 LPS)
3. Full working capacity of pumps at the inter mediate stations 2 towards:
ii) Common discharge at the down stream main leading to terminal station
@ 3250 m3/hr (900 LPS)
iii) Branch discharge of Air base supply at Kolaikunda @ 375 m3/hr (104
LPS)
iv) Branch discharge of Army base at Salua @ 125 m3/hr (35 LPS)
While designing the pump sets and the duty points, necessity for stand by pump has been
considered to negotiate any emergency situation due to pump break down or repair down
time etc. So that station flow requirement at the respective branch / main distribution are not
hampered by any means. Scope of having adequate flexibility in application of pumps under
various working conditions without any sacrifice to the station flow requirement, have also
been considered for optimizing the number of pumps depending on the flow capacity of the
Working and stand by combination of pumps in a distribution group has been considered
such that minimum one working pump shall be provided for any distribution branch upto
375 m3/hr (104 LPS) and min 2 working pumps shall be provided for any other distribution
branch or common main having discharge capacity 500 m3/hr (139 LPS) and above to take
care of widely varying flow condition in the major distribution branch main from the
Capacity design and regulation of flow to the collector well / U/G storage reservoir:
Collector wells of the intake pump house has been designed based on 30 minutes detention
period for the total station flow capacity so as to ensure uniform and steady flow to the VT
pumps after initial draw down in the well, at a velocity below 1 m/sec at the suction inlet,
there by ensuring operation of pumps free from vortex, cavitation and vibration ultimately
U/G storage reservoir for the intermediate / terminal lifting stations have also been designed
based on 1 hr detention period for the total station flow capacity such that adequate steady
depth of water could be ensured for flooded suction to the dry pit pumps causing there by
Isolation valves shall be provided for regulating the flow to the common intake well of the
intake station as well as to the each and individual dry pit pump from the U/G storage
reservoir of the intermediate / terminal lifting station. Sluice valves with long spindle drive
and manual head stock gearing arrangement shall provided with all the Radial Collector inlet
port inside the well for controlling the inflow to the well and shall be operated from the
lower tier below the pump floor as and when necessary to ensure easy maintenance and
Sluice valves shall also be provided for regulation of flow to the dry pit pumps at the
intermediate / terminal lifting station. These valves shall be electric actuator driven and shall
be fitted with all the individual dry pit pumps for isolating the pump suction from the
reservoir water as and when necessary to facilitate easy maintenance and breakdown repair
of the pumps at the pump floor level well below the minimum water level of the reservoir.
V.T. Pumps:
The pumps shall be vertical turbine type, solid shaft, flange mounted motor driven. Installed
capacity of the pumps for each intake station has been designed with 2 pump working and 1
pump as stand by. The pumps shall be L.T. Motor driven with FASD / soft starter.
The pumps shall be multistage design with modified radial / mixed flow character istics and
discharge co-axial with the shaft. The pumps shall have semi open impellers with self water
lubrication and discharge head assy shall be suitable for above floor discharge.
Centrifugal Pump:
The pumps shall be horizontal, solid shaft, foot mounted, motor driven centrifugal pump.
Installed capacity of the pumps lave been so designed that the total pumps at the
intermediate / terminal station for the respective distribution group shall be provided
including working and standby. Working and standby combination of pumps at the
intermediate / terminal station shall be as indicated in Table A1. The pumps shall be HT/LT
The pumps shall be horizontal / radial split casing, multistage design, side / end suction and
The velocity in the pump delivery branch station shall be restricted with 2.5 m/sec and that
in the conveyance main shall be limited to 1 m/sec ever under highest flow condition. Each
pump delivery shall have one Reflux valve to prevent water hammer due to backflow during
sudden slopping / power failure etc. each pump branch line shall also be fitted with one
Butterfly Valve and Dismantling joint for additional protection to the back flow and
providing easy dismantling facility of the internal piping system of the internal piping
system at the pump house for maintenance and repair. Butterfly valves to the pipe lines of
600 mm dia and above shall be of electric actuator driven type. RE joints shall be provided
with the pump delivery branch to minimize the effect of vibration on the supporting
structure.
Suitable size Butterfly valve at the common header and pressure release valve at the
Pump common header shall be generally multipices construction and radial tee / ‘Y’ joint
design and all the pump delivery branches excepting the further one in a group shall be
connected across with the common header leaving its rear end to connect with the further
pump delivery branch and front end with the rising main.
Table A1 List of Pump Houses
Intermediate 2 Hatigeria 250 (70) 3250 - 1083 (300) HSC 3 W + 1S 670 KW - - 1000 13 For distribution to
(900) PHED WB
250(70) - HSC 1W + 1S 90KW 300 10 - - (Khesiyari Block)
Terminal Salua 1750 - 875(243) - HSC 2W+1S 320 750 10 - - For Railway and
(486) Industry supply at
Kharagpur
1000 500(139) - HSC 2W+1S 150 600 6 - - For own use of
(278) - IIT Kharagpur
375 - 375(104) - HSC 1W+1S 90 400 12 - - For Air base
(104) Supply at
Kalaikunda
125 (35) - 125(35) - HSC 1W+1S 22 200 2 - - For Army base
supply at Salua.