Вы находитесь на странице: 1из 28

The Next Generation in

Gas Chromatography:

-- Agilent 7890A GC

LSCA Fast RGA

Page 1 30 Jan, 2007


A tradition of GC Firsts…

and …

7890A GC Flexibility

Page 2 March, 2007


The Next Generation in Gas Chromatography

7890A GC 5975C GC/MS

7890A GC Flexibility

Page 3 March, 2007


All The Elements for Perfect Chemistry

Performance
Performance
&&Reliability
Reliability
Continuous evolution of the GC & GC/MS platforms

Improved
Improved
Productivity
More from your GC&GC/MS without changing methods
Productivity

Capillary Flow
Capillary Flow
Technology
Technology Solve difficult applications problems easily

Unmatched GC/MS
Unmatched GC/MS
Performance
Performance
Sensitivity you can use

Exceptional
Exceptional
Flexibility
Flexibility
Perform more analyses on a single GC

7890A GC Flexibility

Page 4 March, 2007


Performance & Innovation and technology
Reliability continue to evolve with the
new 7890A GC and 5975C
GC/MSD platforms to
improve performance and
reliability … customers
have come to expect this
from Agilent for over 40
years.
LSCA Fast RGA

Page 5 30 Jan, 2007


5th Generation Electronic Pressure Control (EPC)
7890A GC
3rd, 4th Generation EPC
-- 0.01 psi The only GC to regulate
-- Diffusion bonded plate (2D) pressure to 0.001 psi
-- one cable The only EPC regulating
-- three gas connectors pressure to 1/1000 psi
-- “credit card” size

6890N GC
1st, 2nd Generation EPC
-- 0.1 psi
-- cables 5th Generation EPC
-- gas lines & connectors - Metal injection molded (3D)
-- large size - Digital signal pathways

5890 GC
… improved reliability and precision

7890A GC Flexibility

Page 6 March, 2007


Why 0.001 psi Matters!
-- Key to even better Retention Time Locking (RTL)
6.624 (target RT)
Response 6.624
6.641
200000 6.619 “Agilent worries
190000 about the 3rd
180000
decimal, so I don’t
170000
have to worry about
160000
the 1st or 2nd
150000
140000
decimal point…”
130000 - Pharma (USA)
0.97 psi 0.963 psi 0.96 psi
120000
110000 Column 1
100000 at 1.000 psi
90000
80000
Time
6.58 6.59 6.60 6.61 6.62 6.63 6.64 6.65 6.66 6.67 6.68 6.69

7890A GC Flexibility

Page 7 March, 2007


Retention Time Locking (RTL)

Retention times match from column-to-column and


instrument-to-instrument

GC 1
SSL/FPD Column 1

GC 1
SSL/NPD Column 2

GC 2
PTV/µECD Column 1

GC/MS Column 3

7890A GC Flexibility

Page 8 March, 2007


Key Similarities: 6890N vs. 7890A

Feature Advantage/Benefit

Same inlets, detectors, oven Methods compatible


Automation: methods transfer 6890 Æ 7890

Same RT/Area performance Methods compatible

Same column & supplies Low cost of ownership

Similar look & feel (keypad) Low cost of training

… but improved capability and performance

7890A GC Flexibility

Page 9 March, 2007


Improved Productivity New features that increase
laboratory productivity …
without changing current
chromatographic run
methods.

LSCA Fast RGA

Page 10 30 Jan, 2007


Faster Cycle Time…. Without Changing Method During “Run”

Pre-Run Chromatographic Post-Run Post-Run


ALS Set-Up 3min Run 42 min Bake-Out 33min Cool-Down 4min

Total Run Time 82 min

Same Method with New Productivity Features


ALS Chromatographic Backflush Faster Cool-
Overlap 1min Run 42 min 7 min Down 3 min

Total Run Time 53 min

… > 30% saving in cycle time per analysis

7890A GC Flexibility

Page 11 March, 2007


Agilent ChemStations “Backflush Ready” for 7890A

… easy operation that automatically runs as part of your method


7890A GC Flexibility

Page 12 March, 2007


Customer Quotes – Benfits of Backflushing
Faster Cycle “Shorter bake-out time. Not in area of peaks of interest, so
Times implementation cost is low… could extend column lifetime.”
– Europe (Environmental)
“Saves us time, no change to Retention Time (of peaks of
interest), easy to implement.”
– UK (Environmental)

Eliminate “Prevent carryover between samples. HUGE!” – USA (Enviro)


Carryover “Keep column in good condition, reduce re-runs (ghost peaks).”
– USA (Environmental)

Reduce “Backflush will save source cleaning on MSD, keep column


Operating cleaner, save time.”
and – USA (Forensics)
Maintenance
“R&D could use time savings, but less maintenance is more
Costs
important.”
- Japan (Food)

7890A GC Flexibility

Page 13 March, 2007


Lab Monitor & Diagnostic Software – A New Approach

What’s the approach?

– Continuously monitors a single or multiple Agilent GC or GC/MS systems


in real time to alert you maintenance needs and instrument problems
… before they happen

Benefits:
– Keep instruments in top running condition
– Optimize consumables utilization
– Help meet regulatory or internal quality standards
– Store all maintenance documentation in a single location
– Notification of the status for pre-set limits

… improve uptime and increase instrument utilization


7890A GC Flexibility

Page 14 March, 2007


Lab Monitor and Diagnostic Software
Monitors instrument status, chromatographic quality and track
supplies usage to flag problems … before they happen

NGA ANALYZER

“Lab at a Glance”:
a predictive monitor
to give the scientist
SULFUR ANALYZER
“peace of mind”
!

7890A GC Flexibility

Page 15 March, 2007


Agilent Support Solutions

Instrument Self-Service Outsourced Service


and Support and Support

Lab Monitor & Diagnostic SW

Cooperative Support

Intelligent Repair

Intelligent Connections

… new service product choices for your laboratory


7890A GC Flexibility

Page 16 March, 2007


Turn Top Inlet Sealing System

- Fast/Easy Split/Splitless Inlet Maintenance

… changing liners has never been easier

7890A GC Flexibility

Page 17 March, 2007


Exceptional Flexibility Expanded capabilities let
you perform more analyses
on a single GC

LSCA Fast RGA

Page 18 30 Jan, 2007


Agilent’s Recent Acquisition: SCD & NCD
Sulfur and Nitrogen Chemiluminescence Detectors

… all about sensitivity and selectivity


7890A GC Flexibility

Page 19 March, 2007


7890A: GC Platform for the Future…
More Flexibility
Feature Agilent 6890N Agilent 7890A

Detectors 2 3
(3rd Detector = TCD)

Signals 2 4

Auxiliary Modules 1 (Aux EPC Only) 2 (Aux EPC and/or PCM)

PCM Module 1 channel 2 channels (incl BPR)

7890A GC Flexibility

Page 20 March, 2007


Comprehensive Refinery Gas Analysis in 6 min

propane
pA

2-methyl-2-butene
1600

ethane

propylene

1,3-butadiene
1400

i-butane
n-butane
methane

t-2-butene

c-2-butene
cyclopropane
1200

ethylene

1-butene
propadiene

c-2-pentene
t-2-pentene
1000

acetylene

i-butene

n-pentane
i-pentane
800

1-pentene
600

propyne
400
C6+

200 FID Channel


0
0 1 2 3 4 5 6 7 min
25 uV

N2
3500
3000
2500
2000 TCD Channel

methane
1500
Carry gas: He
CO2

1000

CO
O2
500
0
H2

0 1 2 3 4 5 6 7 min
25 uV
500
400
300
methane

200
3rd TCD Channel
100
0 Carry gas: N2
-100
0 1 2 3 4 5 6 7 min

… three detector analysis


7890A GC Flexibility

Page 21 March, 2007


Back-Pressure Regulation for HSS/Gas Sampling

Example: Residual Solvents Analysis


• Reduce atmospheric pressure variation at vent
• High back pressure increases sample in loop

… increased Precision and Sensitivity


7890A GC Flexibility

Page 22 March, 2007


GC & GC/MS Data Systems

• GC ChemStation
• GC/MS ChemStation
• GC/MS ChemStation & ECM
• EZChrom Elite
• Agilent OL system
• Partners’ software
OL
nt
i le
Ag

… choose a data system that best meets your need

7890A GC Flexibility

Page 23 March, 2007


Agilent GC Supplies and J&W Scientific Columns

• 7890 / 5975 Specifications • Stringent quality and testing


determined with Agilent supplies specifications to ensure column
– Pre-cleaned, plasma treated for consistency and performance
cleaner baselines • Full product line for all GC
– Proprietary manufacturing applications
eliminates leaking • New GS-OxyPLOT column for trace
• Convenient, easy to use packaging oxygenate analysis
also keeps supplies clean till used

Other
Supplier’s
O-Ring

Agilent Non-Stick
O-Ring

7890A GC Flexibility

Page 24 March, 2007


Continual Evolution of the Product Portfolio

Capilla
Pur

TCD
Co

uECD
FID
… the largest breadth of integrated

ge P

D
NPD
ol

ry S/S

FP
Vo

on

ack

D
lat

SW

FP
consumables, products, and
Co
ile

L
PT

ed

ed

DW
sI

lum
V

nc
Va nle

ed
lve SD
n
services in the industry

ha

nc
s
t
M

En

ha
Hig D
SC

En
hP
res D
Cha sI NC
nne nle Detectors
t Inlets
l Pa ners
ALS
rtne
rs el Part
nn
-8 Cha

ALS-100 Agilent In-Oven Capillary Flow


GC & GC/MS Flow Control Technology
CTC OEM Samplers System Applications
-12
adSpace Che
He -70 Data Systems mS
p ace EZ tati
on Capillary Flow Technology
adS p Solution &
EC Z hCro
He Tra hrm
& Flow Control Ag om Eli
te -Backflush
rge ile
rs

Pu nt
-Quickswap
ne

LM log

OL
rt

AA//DD
C

An

S
Chhaan

D
Pa

TD
rs

-Heartcutting
SW
a
rtne
l
ne

nnnnneel

Coon
C
Forward PCM
n

ellPP
ha

n
1s

Ou

-Detector Splitter
l Pa

vveer
C

2s
SP

Paaarrttn

t
C

r
SP

teerr
nne

t
rtnneerrss
Aux EP

-GCXGC Modulator
BPR

ss
ers
Ch a

Aftermarket: Consumables & Services

7890A GC Flexibility

Page 25 March, 2007


… the most widely applicated GC & GC/MS Platforms in the industry

7890A GC Flexibility

Page 26 March, 2007


Channel Partner: Solution Highlights
Custom Solutions and Analyzers: (global or regional partners)
AC/PAC: e.g. DHA, Reformulyer and full line of HPI analyzers
Wasson: e.g. specialized valved analyzers, process application and full line of analyzers
SSI: e.g. DHA and HPI applications
JAS: e.g. process and on-line applications
SRA: micro-GC solutions, e.g explosion proof housing u-GC; u-GC coupling to 5975 MSD
Extended Functions and Capabilities:
Ultra Fast GC: GERSTEL - Modular accelerated column heater (MACH)
Multi Purpose Sampler (MPS): GERSTEL: based on CTC with following accessories:
Automatic Liner Exchange (ALEX)
stir bar extraction system (TWISTER) and thermal desorption (TDS)
automated solid phase extraction (SPE)
AED: JAS
MS-DIP: SIM Direct Insertion Probe for 5975 MSD (DIP)
GC QQQ on 5975 MSD: Chromtech
Pyrolyzer: Quantum Analytics
Special Services:
Rental, Lease: Quantum Analytics (N. America only)

… check out CP web sites for more details


7890A GC Flexibility

Page 27 March, 2007


The Next Generation 7890A GC

• Expanded chromatographic capabilities


• Improved retention time locking precision
• Faster cycle times without changing chromatographic run methods
• Innovative software to simplify routine maintenance
• Extended flexibility

7890A GC Flexibility

Page 28 March, 2007

Вам также может понравиться