Вы находитесь на странице: 1из 109

Plant:

Location of port:

Clinker output 6000 TPH


Elevation: 250 Meter
Barometric pres: 10020 mmwg
Duct diameter 2.35 Meter
Area 4.3391071429 Meter²
Ambient Temperture 25 °C
Process Temperture 374 °C
Static Pressure -483 mmwg
Pitot tube Factor 0.84
static pressure at fan outlet 100 mmwg
Density of gas calculation

Air constituents %Vol


Oxygen 70
Carbon di oxide 30
Carbon mono oxide 10
Nitrogen 22

Density of gas 1.99002 kg/Nm^3


0.54 Kg/m^3

Dynamic pressure measurement

Avarage dynamic pressure 8.92 mmwg

Velocity 15.122177621 m/sec


Volume flow 236220.296150454 m^3/hr
Volume flow 91994.3021462004 Nm^3/hr
Mass flow 127558.959921245 kg/hr
Clinker Rate 6000000 kg/hr
Specific mass flow 0.0212598267 Kg/Kg Clinker
Specific gas flow 0.0153323837 Nm³/Kg Clk

Fan Efficiency determination

Fan Total Pressure 583 mmwg


Compressibility coefficient 2.5
Absorbed power 1000 KW
Air power 938.1931974671 KW
Shaft power 970 KW
Fan efficiency 96.7209481925
Voltage rating 100
Current 200
Power factor 0.85
Power 29444
Air power/0.80 1172.7414968338 KW
Power saving -202.7414968338 KW
FAN FLOW MEASUREMENT
P SHAFT Pabs -(Fixed losses + Copper losses + Stray load loss @ 3% of motor absorbed power)
OW MEASUREMENT