Вы находитесь на странице: 1из 4

TM

GROW TH

G
Associates

GROW TH
G

Associates
Growth Associates

Growth Associates
Office Address :
131, IInd Floor, Opp. PNB, B.T. Ganj,
Roorkee - 247 667,
Distt. Haridwar (Uttarakhand)
Telefax-01332-261499
Mob. : 9760212499
E-mail : sales@growthassociates.in
Customer Care No.: +91-9634570602

www.growthassociates.in Complete Environmental Testing Solution


Environmental Test Chamber, Thermal Shock Chamber, Corrosion Test Chamber
Rain Chamber, Dust Chamber, Walk-in Chamber, Vibration Test System, Cord Room
1 COMBINED ENVIRONMENTAL TEST CHAMBER 3 DUST TEST CHAMBER G
TM

GROW T
Associa
tes
H

TECHNICAL SPECIFICATIONS TM
TECHNICAL SPECIFICATIONS
GROW TH
Test Space Capacity : 50 lts to 8000 lts

G
Test Space Capacity : 216 lts to 8000 lts
Associates

Temperature Range : -70°C to +125 °C ±1°C Temperature Range : 5°C above ambient
Temp. Accuracy : ±1°C to +75°C ±1°C
Humidity Range : 20% to 97%, ±3%RH Power Supply : 230 V ±10%, 1 Phase,
Dew Point Range : +4°C to +85°C 50Hz, A.C. Or 415 V ±10%,
Climatic Range : +25°C to +85°C 3 phase-neutral, 50 C/s. A.C.
Rate of change of temp. : 1°C/minute, 5°C Features : Dust agitation mechanism to
and 10°C/minute satisfy IS 9000 and JSS 55555.
Altitude : 1 Lakh Feet Vacuum system with Rotameter, etc...
Vibration : Sinusoidal/Random to satisfy ingression prevention as per IS
Features : ON-OFF/ PID type controllers OR Dual loop 2147(IP) and IS 10236. ON-OFF type controllers.
Microprocessor programmer, Recorder. Air Performance : Conforms to IS 9000, JSS 55555 and IS 2147,
cooled/water cooled, sealed/open type CFC Free IS 10236 specifications.
refrigeration system.
Performance : Conforms to IS 9000, JSS 55555, 50101, IEC 68,
MIL-STD-202, 810, 883, DEF-STD-133
specifications

2 THERMAL SHOCK CHAMBER


G 4 HUMIDITY TEST CHAMBER
TECHNICAL SPECIFICATIONS
TM
GR
Associates

TECHNICAL SPECIFICATIONS
OW TH

Test Space Capacity : 27 lts to 216 lts


Test Space Capacity : 50 lts to 8000 lts
TM

G
GROW TH
Temperature Range : -70°C to +200°C ±1°C Associates
TM

Temperature Range : -65°C to +125°C ±1°C

G
GROW TH
Associates
TM

G
GROW TH
Associates

Humidity Range : 20% to 97%, ±3%RH


Dew Point Range : +4°C to +85°C Temp. Accuracy : ±1°C
Climatic Range : +25°C to +85°C Humdity Range : 20% to 97%, ±3%RH
Recovery Time : 5 minutes as per MIL 883 Dew Point Range : +4°C
Method 1010.2 Rate of change of temp. : 1°C/minute, 5°C
Power Required : 230 V ±5%, 1 Phase, and 10°C/minute
50 Hz AC/ 415 V ±5%, 3 Phase-Neutral, Features : ON-OFF/ PID type controllers or Dual loop
50 Hz. AC. microprocessor programmer, recorder. Air
Features : ON-OFF/ PID type controllers or Microprocessor cooled/water cooled/sealed/open type
programmer, Recorder. Air cooled/water cooled, refrigeration system.
sealed/open type CFC Free refrigeration system. Performance : Conforms to IS 9000, JSS 55555, 50101, IEC 68,
Performance : Conforms to IS 9000, JSS 55555, 50101, IEC 68, MIL-STD-202, 810, 883, DEF-STD-133
MIL-STD-202, 810, 883, DEF-STD-133 specifications
specifications
5 RAIN TEST CHAMBER
7 BUMP TEST SYSTEM

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS


Test Space Capacity : 216 lts to 8000 lts Platform Size (mm) : 1000 x 1000
Performance : Conforms to IS 9000, JSS 55555 and Payload Capacity (Kg) : 1000
IS 2147, IS 10236 specifications. Pulse Acceleration (g) : 2-50 (300*)
Power Supply : 230 V ±10%, 1 Phase, Pulse Duration (mS) : 3-18
50Hz, A.C. Or 415 V ±10%, Pulse Shape : Half-Sine
3 phase-neutral, 50 C/s. A.C. Bump Rate (Bumps/sec) : 1-3 TM

GROW TH

G
Drop Height (mm) : 50 (300*) Associates
TM

GROW TH Machine Weight (Kg) : 3200

G
Associates

Machine Dimension (mm) : 1600x1600x1000


Utilities to be provided : Dry filter air 6-8 bar, Power supply 415VAC±10%,
3-phase, 50/60 Hz
Pneumatic Internal
W TH Load Support : Mains Input Over & Under Voltage, Phase fail,
TM

RO
GAs
G

sociates

Operator safety during pad change

6 SALT SPRAY TEST CHAMBER


8 VIBRATION TEST SYSTEM

TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS G
TM
Sine Force KgF (lbf) : 200 (440)
Test Space Capacity : 420 lts to 2000 lts
GROW
TH
Random Force KgF (lbf) : 140 (308)
Associ
ates

Temperature Range : +35°C to +60°C ±1°C


Shock Force Kgf (lbf) : 400 (880)
Humidity : Saturated Condition
Fog Collection : 0.5ml to 3ml per hour. Armature Diameter mm (in) : 140 (5.5)
Power Required : 230 V ±5%, 1 Phase, Peak Acceleration g (m/sec2): 60 (588) W
TH
tes
RO cia
50 C/s AC/ 415 V ±5%, Peak Velocity m/sec (in/sec) : 1.4 (55)
TM
o
G ss

G
A

3 Phase, 50 C/s AC Pk-Pk Displacement mm (in) : 25.4 (1)


Control System : PID type or programmable
Armature Resonance Hz (±5%) : 3500
microprocessor based control
system for cyclic chamber. Useful Frequency Range Hz : DC-4200
Features : CFC Free semi-sealed/open type refrigeration Max. Static Payload
system, microprocessor based programmable Capacity kg (lb) : 20 (44)
control system. Trunnion Mounting : Provided
Performance : Conforms to IS 9000, IS 5528, IS 6910, ASTM B
117, JIS 2371
Customer Care WHY
ENVIRONMENTAL
& Services TESTING
Environmental testing is a mandatory
requirement because it involves safety and reliability -
not only of products but also of life. Market
reputations are gained or lost because of
Customer service is not merely creating relations, it is oriented
performance.
towards customer delight. Every customer is an individuals, hence
special to us. When we are delighted to serve our customer, our For some manufacturers environmental testing
customers too find our service delightful. is a customer's demand that must be fulfilled. Others
Our committed towards customer service developing trust : undertake it to support warranty agreements.
Quality of service, knowledge, expertise, courtesy and promptness- Some manufacturers offer extended
these are teh hallmarks on which we develop trust actually begins even warranties on their products, especially to remain
before the sale. Each customer receives personal attention, and we
competitive.
make ourselves available at any time should our services be required.
Extended services : Growth Associates offers This can be prevented. Where there is no
comprehensive Annual Maintenance Contact (AMC) beyond teh pressure to prove long-term reliability, manufactures
warranties. Our promptness saves the money and time of the customer. are tempted to regard environmental testing as an
Some of the highlist of extended services includes : High Quality unnecessary cost or a hindrance.
customer support 24 hrs x 7 days "Service hot-line" Installation adn
Commission Operation and parts warranty application guidance.
These manufactures should realize that the
cost of environmental testing is their negligible
Training Programme.
compared to the cost of failures in the field and
Original spares easy reach : Our website contains al information about compared to the cost of failures in
the company and products listing and their specifications, technology
updates and current news. Just fill up the feedback form and get
the field adn a permanent loss
immediate response. of credibility in the
market.
Design and Development : Do you have a specify product in mind? Draw
out the specifications and hand them over to our nearest sales
representatives.

Вам также может понравиться