Вы находитесь на странице: 1из 1

Wind load on as per MBMA 2006 (STP Shed)

Building input:
Location Jabalpur
Length L 30.386 m 99.69 ft
Width B 15.886 m 52.12 ft
Bay spacing 5m 16.40 ft
Clear eave hight 5.136 m 16.85 ft
Roof slope 1 in 10 m
Roof slope 2.862 degree

Basic wind speed 39.00 m/sec 87.24 mile/hr


Building use category II
Encloser condition of the building Enclose
Exposer category B
Velocity pressure exposer coefficient Kz 0.90
Topography factor Kzt 1.00
Directionality factor Kd 0.85
Importance factor I 1.00
Velocity pressure qh 0.71 kN/sqm 14.91 Psf

Wind direction perpendicular to the ridge

Case-A Positive internal pressure (0 & 180 deg)


Location (GCpf-GCpi) Load (kN/m) -3.1 kN/m -2.0 kN/m
Wind ward wall 0.22 0.8
Wind ward Roof -0.87 -3.1 0.8 kN/m -1.7 kN/m
Lee ward Roof -0.55 -2.0
Lee ward Wall -0.47 -1.7
End walls -0.63 -2.2

Case-B Negetive internal pressure (0 & 180 deg)


Location (GCpf-GCpi) Load (kN/m) -1.8 kN/m -0.7 kN/m
Wind ward wall 0.58 2.1
Wind ward Roof -0.51 -1.8 2.1 kN/m -0.4 kN/m
Lee ward Roof -0.19 -0.7
Lee ward Wall -0.11 -0.4
Lee ward Wall -0.27 -1.0

Wind direction parallal to the ridge codition

Case-A Positive internal pressure (90 & 270 deg)


Location (GCpf-GCpi) Load (kN/m) -3.1 kN/m -3.1 kN/m
Wind ward wall 0.22 0.8
Wind ward Roof -0.87 -3.1 0.8 kN/m -1.7 kN/m
Lee ward Roof -0.87 -3.1
Lee ward Wall -0.47 -1.7
END walls -0.63 -2.2

Case-B Negetive internal pressure(90 & 270 deg)


Location (GCpf-GCpi) Load (kN/m) -1.8 kN/m -1.8 kN/m
Wind ward wall 0.58 2.1
Wind ward Roof -0.51 -1.8 2.1 kN/m -0.4 kN/m
Lee ward Roof -0.51 -1.8
Lee ward Wall -0.11 -0.4
End walls -0.27 -1.0

Вам также может понравиться