Академический Документы
Профессиональный Документы
Культура Документы
Gas Phase
Stream Qg (m3/h) Qg (mmscf/day) Temperature,T (C) P (atm)
1 87.38 0.0742288709 25 40
2 89.48 0.0760128104 51.97 54.28
3 96.83 0.0822565985 51.97 39.28
4 0.1941 0.000164887 51.97 39.28
6 3495 2.9689849385 25 3
8 2444 2.0761657195 74.4 5
9 2336 1.9844202622 50 4.864
10 185.3 0.1574114189 49.8 3
12 17150 14.5688388253 67.93 2
14 22820 19.3854753349 120.7 2
16 4341 3.6876576875 -14.11 2
18 2043 1.7355182344 83.36 5.848
19 1750 1.4866162067 25 5.712
20 802 0.6812949701 136 17.1
21 628.2 0.5336527434 44.74 16.96
22 289.8 0.2461836438 159.2 50
27 464.9 0.394930214 130.7 39.28
28 255.8 0.2173008147 228.2 88.62
29 200.9 0.1706635405 120 88.48
30 110.6 0.0939541443 216.1 200.1
31 101.3 0.086053841 175 200
36 676.7 0.5748532497 117.5 22
40 2147 1.8238657118 78.6 2
44 10620 9.021636637 150 2.66
46 914.9 0.7772029528 217.1 6.54
47 854.1 0.7255536584 175 6.404
48 355.5 0.3019954637 336.8 20.94
49 1068 0.9072606336 171.1 20.94
50 213.5 0.1813671772 171.1 20.94
51 854 0.7254687089 171.1 20.94
52 867.1 0.736597093 175 20.8
53 353.2 0.3000416253 323.7 68.02
54 262.8 0.2232472795 170 67.88
55 116 0.0985414171 304.5 200.4
56 100.4 0.0852892955 226.5 200.3
Multiphase
Stream Qtotal (m3/h) Qtotal (bbl/day) Temperature,T (C) P (atm)
34 588.8 88885.248 118.6 25.14
35 605.1 91345.896 120 25
38 686.2 103588.752 97.67 5.34
39 652 98425.92 90 5
43 413.3 62391.768 150 5.66
Min Diameter (in) Max Diameter (in)
3.0425100164 6.8032592189
3.0423115422 6.8028154172
3.2849080352 7.3452776666
1.5447898498 3.4542551151
3.6497548411 8.1610999259
3.165648218 7.0786046083
1.3677340092 3.0583462198
2.8549312286 6.3838202982
1.3628689739 3.0474676701
1.3957033496 3.1208875661
2.4346033435 5.4439385742
2.4286434732 5.4306118992
1.9100788675 4.2710661901
1.752119448 3.9178581904
1.752119448 3.9178581904
1.0968549658 2.452642265
1.032657465 2.3090922892
1.032657465 2.3090922892
Liquid Flow Rate (m3/h) Gas Flow Rate (m3/h) Z Factor Min Diameter (in) Max Diameter (in)
31.01 557.8 1 6.455463968 14.4348562588
30.81 574.3 1 6.617569965 14.7973362876
26.6 659.6 1 13.0979119229 29.2878214229
26.7 625.3 1 12.7005198444 28.3992257217
25.42 387.9 1 8.5713836837 19.166196578
Pressure (psia) Minimum Velocity Required (ft/s)
587.84
797.69888
577.25888
577.25888
44.088
73.48
71.481344
44.088
29.392 31.7
29.392 48.71
29.392
85.942208
83.943552
251.3016
249.24416
734.8
577.25888
1302.35952
1300.30208
2940.6696
2939.2
323.312
29.392
39.09136 18.32
96.11184
94.113184
307.73424
307.73424
307.73424
307.73424
305.6768
999.62192
997.56448
2945.0784
2943.6088
HEX Stream Type T supply (C) T target (C) Flow Rate (kgmole/h)
E-101 8 to 9 Hot 74.4 50 428.6
E-102 18 to 19 Hot 83.36 25 408.5
E-103 20 to 21 Hot 136 44.74 408.5
E-301 28 to 29 Hot 228.2 120 551.1
E-302 30 to 31 Hot 216.1 175 555.1
E-501 38 to 39 Hot 97.67 90 1226
E-701 46 to 47 Hot 217.1 175 2565
E-703 53 to 54 Hot 325 170 490.5
E-704 55 to 56 Hot 304.5 226.5 490.5
E-706 57 to 58 Hot 184.3 175 490.5
E-104 25 to 26 Cold 124.2 175 800
E-401 34 to 35 Cold 118.6 120 1690
E-601 42 to 43 Cold 78.69 150 1077
E-702 47 to 48 Cold 171.1 175 490.5
300
250
Shifted temperature
200
150
100
50
0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Cummulative delta h
Average Heat Capacity (kJ/kmol*C) FCp (kW/K) ΔH T supply (shifted) T target (shifted)
36.595 4.3568380556 106.3068 69.4 45
36.425 4.1332256944 241.2151 78.36 20
37.4 4.2438611111 387.2948 131 39.74
40.555 6.2082945833 671.7375 223.2 115
41.18 6.3497272222 260.9738 211.1 170
83.385 28.397225 217.8067 92.67 85
39.555 28.1829375 1186.502 212.1 170
44.88 6.1149 947.8095 320 165
46.18 6.292025 490.778 299.5 221.5
64.39 8.7731375 81.59018 179.3 170
76.665 17.036666667 865.4627 129.2 180
83.95 39.409861111 55.17381 123.6 125
87.205 26.088829167 1860.394 83.69 155
41.39 5.6393875 21.99361 166.1 170
Hot Stream
Col d Stream
ve delta h
hot stream
cold stream
HEX Stream Type T supply (C) T target (C) Flow Rate (kgmole/h)
E-101 8 to 9 Hot 74.4 50 428.6
E-102 18 to 19 Hot 83.36 25 408.5
E-103 20 to 21 Hot 136 44.74 408.5
E-301 28 to 29 Hot 228.2 120 551.1
E-302 30 to 31 Hot 216.1 175 555.1
E-501 38 to 39 Hot 97.67 90 1226
E-701 46 to 47 Hot 217.1 175 2565
E-703 53 to 54 Hot 325 170 490.5
E-704 55 to 56 Hot 304.5 226.5 490.5
E-706 57 to 58 Hot 184.3 175 490.5
E-104 25 to 26 Cold 124.2 175 800
E-401 34 to 35 Cold 118.6 120 1690
E-601 42 to 43 Cold 78.69 150 1077
E-702 47 to 48 Cold 171.1 175 490.5
350
300
250
Actual Temperature
200
150
100
50
0
0 500 1000 1500 2000 25
Cummulati
Average Heat Capacity (kJ/kmol*C) FCp (kW/K) ΔH T supply (shifted) T target (shifted)
36.595 4.3568380556 106.3068 69.4 45
36.425 4.1332256944 241.2151 78.36 20
37.4 4.2438611111 387.2948 131 39.74
40.555 6.2082945833 671.7375 223.2 115
41.18 6.3497272222 260.9738 211.1 170
83.385 28.397225 217.8067 92.67 85
39.555 28.1829375 1186.502 212.1 170
44.88 6.1149 947.8095 320 165
46.18 6.292025 490.778 299.5 221.5
64.39 8.7731375 81.59018 179.3 170
76.665 17.0366666667 865.4627 129.2 180
83.95 39.4098611111 55.17381 123.6 125
87.205 26.0888291667 1860.394 83.69 155
41.39 5.6393875 21.99361 166.1 170
Hot Strea m
Col d Stream
Cummulative delta h
hot stream
cold stream