Вы находитесь на странице: 1из 3

COLUMN LATERAL TIES CALCULATOR (USING SEISMIC PROVISION)

Note: For main bars, please see tabulation or STAAD Results.


COLUMN TYPICAL COLUMN DETAILS
FLOOR FLOOR DIMENSION LATERAL TIES
LEVEL DESIGNATION D1 (mm) D2 (mm) SIZE (mm) SPACING

GROUND 1 @ 50 MM, 12 @ 75 MM, REST


0 - 6.9 350 500 12
FLOOR UP TO MIDHEIGHT @ 150 MM

SECOND 1 @ 50 MM, 7 @ 75MM, REST


6.9-10.7 350 500 12
FLOOR UP TO MIDHEIGHT @ 150 MM

2 @ 50 MM, 7 @ 75MM, REST


10.7-14.5 THIRD FLOOR 350 500 12
UP TO MIDHEIGHT @ 150 MM

FOURTH 3 @ 50 MM, 7 @ 75MM, REST


14.5-18.3 350 500 12
FLOOR UP TO MIDHEIGHT @ 150 MM

Note: For main bars, please see tabulation or STAAD Results.


COLUMN TYPICAL COLUMN DETAILS
FLOOR FLOOR DIMENSION LATERAL TIES
LEVEL DESIGNATION D1 (mm) D2 (mm) SIZE (mm) SPACING

RAMP 1ST 1 @ 50 MM, 10@ 85 MM, REST


0 - 6.9 250 250 12
LANDING UP TO MIDHEIGHT @ 100 MM
PROVISION)
Main Bar: 25
Unsupported Length: 3.35
for Lo: for spacing along Lo: Number of LT along hoop: Within Midheigth
D1 D2 L/6 D1/4 D2/4 6db 7 pcs 6db
350 500 558 450 87.5 125 150 100 150 150
Use Lo= 559 Use So = 87.5 Use S= 150

Main Bar: 16
Unsupported Length: 3.45
for Lo: for spacing along Lo: Number of LT along hoop: Within Midheigth
D1 D2 L/6 D1/4 D2/4 6db 10 pcs 6db
250 250 575 450 62.5 62.5 96 100 96 150
Use Lo= 575 Use So = 62.5 Use S= 96

Вам также может понравиться