Orona 3G

1020
Machine-room above solutions
With the latest
lates t direct drive (Gearless) technology.
technology.
Orona 3G
1020
The base solution with machine-room and latest technology.

General specifications
Load / Capacity 320-450-630 kg
4-6-8 persons
Speed 1 m/s
Maximum travel 45 m
Maximum floors served 16 floors
Entrances 1 front 2 open through 2 front & side
Drive system Direct Gearless
Controller ARCA II controller, low energy microprocessor
Door types Automatic side-opening Automatic centre-opening
Clear door opening 700 800 900
Door height 2000 2100
Car dimensions Standard car dimensions
Internal car height 2100 2200
Aesthetic solutions C1 C2 C3 C4
Standard Optional

Aesthetic solutions See the ‘Design and Accessibility’ brochure for a full range of aesthetic solutions.

C1 C2 C3 C4

Options See the ‘Orona 3G Options’ brochure for a full range of available options.

ECO-EFFICIENCY DESIGN AND


Automatic car lighting turn off ACCESSIBILITY
Efficient lighting EN 81-70 accessible car
Landing illumination control Photoelectric curtain

ADAPTABILITY CONTROL AND


Wide-framed door SAFETY
Lift well enclosures Collective controls
Reduced headroom Pre-opening doors
Accessible space bellow the pit Teleservice system
Automatic rescue system
Layout
1 ENTRANCE 2 ENTRANCES (OPEN THROUGH) VERTICAL SECTION

AH AH

PL2       )
      1
      (

      M
      C
      H

      H        C
      F AC       F        H AC        C
       F        F

PL PL1       P
      U
      H

      U       C
      P       H
2 ENTRANCES (FRONT & SIDE)       H

AH

AC

WIDE-FRAMED DOOR DETAIL

       2
       L
       C P
       H F
       F
PL

PL1       F
      H

(1) HCM - minimum 2000 mm

Standard dimensions
LOAD / LIFT SHAFT *
CAR
CAPACITY SIDE-OPENING DOORS CENTRE-OPENING DOORS

Q AC FC PL ENTRANCES AH1 FH2 AH FH3 HF HUP


PERSONS LOAD WIDTH DEPTH CLEAR OPENING ACCESSIBILITY No. OF ENTRANCES WIDTH DEPTH WIDTH DEPTH PIT HEADROOM

1 1350 1300
1325 1600
4 320 kg 825 1100 700 2x1800 1500 1400 3400
2x90 0 1450 1350
1 1500 1450 3400
1500 1800
(3000) 5
6 450 kg 1000 1250 800 2x180 0
1650 1550
2x90 0 1625 1500 1000 3400
(850)4
1 1650 1600
1600 2000 3400
1100 1400 900 2x1800 1800 1700
(3000) 5
2x90 0 1725 1650
8 630 kg
1 1500 1450
1700 2000
1200 1250 900 2x1800 1650 1550 3400
2x90 0 1825 1575
1 ) Accessible space below the pit (counterweight with safety gear) add 50 mm to AH 4 ) HF reduced pit optional 850 mm
2 ) Shaft depth with door tracks projecting 60 mm on the landing 5 ) HUP minimum for internal car height (HC) 2100 mm (HUP=HC+1300)
3 ) Shaft depth with door tracks projecting 40 mm on the landing HUP reduced headroom optional (HUP=HC+900)
* Minimum plumb measurements
MACHINE-ROOM
A traditional configuration simplifies lift
maintenance.
DRIVE
Compact, quiet, gearless, energy
efficient, speed controlled permanent
magnet electric motor.

NEW GENERATION
OF DOORS
Compact permanent magnet motor for fast, TRACTION ROPES
accurate and quiet door operation giving the
They replace the traditional steel wire ropes.
most advanced performance. Advanced door
Owing to their lighter weight, longer lifespan
opening and photoelectric curtain.
and greater flexibility, they make it possible
to use a more compact machine with a more
efficient and ecofriendly motor.

AUTOMATIC
RESCUE SYSTEM
With floor level indication to ensure fast,
 .
   a
   t efficient and safe evacuation of
   a
    d
   r passengers in the event of an emergency.
   e
    h
   t
   o
As an option, the system can incorporate
   r
   o
    / a fully-automatic rescue device to
    d
   n
   a
   s
evacuate passengers in OPTIMISED
   n
   o
    i
   t
the event of a power failure. PASSENGER UNIT
   a
   c
    fi
    i
   c
   e
Saves space, reduces weight, improves
   p
   s
   r
safety, and improves the installation
   e
   t
    l
   a
process.
   o
   t
   e
   m
    i
   t
   y
   n
   a
   t
TWO-WAY
   a
   t
    h
COMMUNICATIONS
   g
    i
   r
   e
Between the lift and the emergency
    h
   t
   s
24-hour Service Call Centre according to
   e
   v EN 81-28 (optional).
   r
   e
   s
   e
   r
   a
   n
   o
   r ACCESSIBLE SPACE
    O
   ;
   y
    l
   n
BELOW THE PIT
   o
   s Adapts the lift to suit buildings which have
   e
   s
   o
   p
   r an accessible space below the pit (optional).
   u
   p
   n
   o
    i
   t
   a     5
   m   -
   r
   o
    5
    f     0
    /
   n
    i
    l     2
   a
   r     1
   e     4
   n     4
   e
   g   -
   r     0
   o
    f     2
   s     0
    i     1
   n
   o
    i
   t
   a
   c
    i
Orona 3G   -
    G
    3
   a

1020
    l
    b    n
   u    o
   p
   s
   r
    i
    h ECO-EFFICIENCY ADAPTABILITY DESIGN AND CONTROL AND     O
    T     ©
ACCESSIBILITY SAFETY

Вам также может понравиться