NASH AT3006 e You Want I

r t
Two Stage Vacuum Pump

he

•
W a n t It
vi c e W
Consider these facts:
• The power industry in North America

Ser
still relies on large coal plants

u
Yo
• The resurgence of nuclear power in Se
Increase your dry air

•
North America and globally will r vic en
e Wh
increase demand for exhauster
packages with greater capacity
capacity without
• Natural gas prices have risen by a Service Locations increasing your
factor of four in the past three years
Birmingham, Alabama power usage
Based on these needs, the AT3006 vacuum Cleveland, Ohio
pump was created to deal with the Houston, Texas
increased air in-leakage. St. Peters, Missouri
Vancouver, Washington
Proven Performance:
The AT06 cone has been used in the All Nash Service Centers are
AT706, AT1006 and AT2006 for over ten ISO 9001:2000 Certified
years, and is now available in our largest
AT model, the AT3006.

A trial pump was built and tested at a Gardner Denver


Gardner Denver Nash facility. The test Engineered Products Div.
results showed an increase in dry air 9 Trefoil Drive
capacity of up to 25% in the high vacuum Trumbull, CT 06611 U.S.A.
range without an increase in power usage. phone: 800 553 NASH
+1 203 459 3900
The AT3006 offers higher operating effi- fax: +1 203 459 3988
ciency than the AT3004, and with today's nash@gardnerdenver.com NASH AT3006
energy costs, efficiency is an important www.GDNash.com
factor for our customers. Two Stage
Liquid Ring
AT3006-DM-1063B-1108
©2008 All Rights Reserved
Vacuum Pump
Printed on recycled paper
1) Can you hold condenser vacuum with one pump?
A 20% Capacity Increase Can:
2) Have you changed pump bearings in the last ten years? • Lower condenser backpressure
3) Is your condenser exhauster packing leakage acceptable?
• Lower dissolved oxygen levels
• Improve plant heat rate
4) Would a 20% increase in vacuum pump capacity be a bad thing?

If you answered “no” to any of these questions, you should consider a Inlet Saturation Performances
Nash overhaul of your condenser exhauster vacuum pump 30” Hg Barometer
60°F Seal Water - 7.5°F Subcool

Benefits A Nash Pump


120
450 RPM
100
Better than new performance Overhaul Includes:

Volume - SCFM at
the Inlet Pressure
80
Avoidance of costly breakdowns AT3006E
60
Extended plant life • Tear down and rebuild by AT3004E
40
Certified Nash warranty Nash certified technicians 20
Peace of mind
0
• Replace cones with newly 1 1.5 2
Inlet Pressure - Inches of Mercury Absolute
2.5

patented design, providing 80


a 20% capacity increase 500 RPM
• Reset clearances for 60

Volume - SCFM at
AT2006E

the Inlet Pressure


improved performance
40
• Retest to HEI standards AT2004E

20

• Replace bearings before they


reach their designed B-10 0
1 1.5 2 2.5

life (100,000 hrs) Inlet Pressure - Inches of Mercury Absolute

40

• Replace packing and first 30


690 RPM

Volume - SCFM at
AT1006E
stage lantern gland

the Inlet Pressure


• Repipe lantern gland flushing 20
AT1004E

10
• Replace interstage check
valve clapper 0
1 1.5 2 2.5
Inlet Pressure - Inches of Mercury Absolute