Академический Документы
Профессиональный Документы
Культура Документы
Circuit Protectors
08 Low Voltage Current-Limiting Fuses
CIRCUIT PROTECTORS
Measuring Instruments, Arresters, Transducers
09 Power Factor Controllers
Power Monitoring Equipment (F-MPC)
CP-V type
AC Power Regulators Circuit protectors
10 Noise Suppression Filters
Control Power Transformers
LOW
VOLTAGE
EQUIPMENT BLC, CR and CS types
Up to 600 Volts Super Rapid Fuses
Page
Circuit Protectors CP31F, 32F, 33F............................................................................................... 08/1
CP31, 31D, 32D............................................................................................... 08/5
CP31P, 32P, 33P.............................................................................................. 08/8
CP51B, 52B, 53B............................................................................................. 08/14
CP31E, 32E, 33E, 34E, CP31V, 32V, 33V, 34V............................................... 08/19
Low Voltage Fuses General information.......................................................................................... 08/25
Current-limiting fuses
AFaC, BaC................................................................................................... 08/26
FCF, FCK..................................................................................................... 08/29
Super rapid fuses
BLC, CR, CS................................................................................................ 08/31
MINIMUM ORDERS
Orders amounting to less than ¥10,000 net per order will
be charged as ¥10,000 net per order plus freight and
other charges.
■ Description
FUJI's compact and high-performance
CP-F series circuit protectors incorporate
FUJI's advanced technology.
Their thin sizes make them ideal for use
as AC/DC line switches in office and
industrial equipment. KKD09-078 KKD09-079 KKD09-095
08
Main contact Auxiliary switch/W Alarm switch/K
ON
Ratings of auxiliary and alarm
switches
21 20 30
Standard type (Type W, K)
OFF 13 11 12
250V AC Resistive load: 1A
Inductive load: 0.5A
125V AC Resistive load: 3A
Inductive load: 1A TRIP
60V DC Resistive load: 1A 21 20 30
Inductive load: 0.5A
13 11 12
30V DC Resistive load: 2A
Inductive load: 1A Number of auxiliary and alarm switches mountable
Minimum permissible load 1-pole 2-pole 3-pole
For low level circuit (Type W1, K1) LINE W or W1: At right-pole
24V DC 1mA K or K1: At left-pole
W, W1 W+W or
12V DC 2mA K or K1 W1+W1 WW or W1 W1: At right-pole
6V DC 5mA ON (Select ON ON
K+W or and center-pole
one K1+W1 WK or W1 K1:
switch)
Aux. switch at right -pole
K or K1 W or W1 and alarm switch at left-pole
LOAD
3.5
AF92-559
5000 ø3.5
4000
3000
46.6
2000
2
1 9.8
1000
21.6
0 1 2 3 4 5 6 7 8 9 10
Pulse time (ms)
Pulse time
■ Characteristic curves
Long time delay tripping type Medium time delay tripping type Instantaneous tripping type
AC circuit only AC/DC circuit AC/DC circuit
180 180
180 120
120 120
90 90
90 60
60 50 60
50 40 AC 50
40
Minute
40 30
Minute
30
Minute
30 20
20 20
10
10 8 DC 10
8
8 6 6
6 4
4 4
2 2
2
1 1
Max. value
1 40
Operating time
40
Operating time
40
Operating time
20 Max. value
20 Max. value 20 Min. value
10 10
10 8
8 6 8
6 6
4 4
4
Max. total fault
Max. total fault 2
Second
clearing time 2
Second
2
Second
Long time delay with inertia delay device Ambient temperature compensation
AC circuit only
60 at 40˚C
50
40
30
20
10
Scale factor of operating time (%)
Minute
8
6
4
2
1
40
160 Ref. temp.: 40˚C
Max. value 120
Operating time
20
10 100
8
6
4
80
2 Min. value 60
1
0.8
Second
0.6
0.4
40
0.2
0.1
0.08 Max. total fault
0.06 clearing time
0.04
-10 0 10 20 30 40 50 60
0.02
Ambient temp. (˚C)
0.01
0.006
1 1.5 2 3 4 5 6 7 8 910 15 20 40 60 80 100
■ Versions
Operating CP31F (1-pole) CP32F (2-pole) CP33F (3-pole)
characteristic Type Type Type
Without inertia Long time CP31FS/씲 CP32FS/씲 CP33FS/씲
delay device Medium time CP31FM/씲 CP32FM/씲 CP33FM/씲
Instantaneous CP31FI/씲 CP32FI/씲 CP33FI/씲
With inertia delay Long time CP31FS/씲D CP32FS/씲D CP33FS/씲D
device Medium time CP31FM/씲D CP32FM/씲D CP33FM/씲D
Instantaneous — — —
With standard Long time CP31FS/씲W CP32FS/씲W CP33FS/씲W
auxiliary switch Medium time CP31FM/씲W CP32FM/씲W CP33FM/씲W
Instantaneous CP31FI/씲W CP32FI/씲W CP33FI/씲W
With standard Long time CP31FS/씲WD CP32FS/씲WD CP33FS/씲WD
auxiliary switch and Medium time CP31FM/씲WD CP32FM/씲WD CP33FM/씲WD
inertia delay device Instantaneous — — —
With standard Long time CP31FS/씲K CP32FS/씲K CP33FS/씲K
alarm switch Medium time CP31FM/씲K CP32FM/씲K CP33FM/씲K
Instantaneous CP31FI/씲K CP32FI/씲K CP33FI/씲K
With standard Long time CP31FS/씲KD CP32FS/씲KD CP33FS/씲KD
alarm switch and Medium time CP31FM/씲KD CP32FM/씲KD CP33FM/씲KD
inertia delay device Instantaneous — — —
With auxiliary switch Long time CP31FS/씲W1 CP32FS/씲W1 CP33FS/씲W1
for low level circuit Medium time CP31FM/씲W1 CP32FM/씲W1 CP33FM/씲W1
Instantaneous CP31FI/씲W1 CP32FI/씲W1 CP33FI/씲W1
With auxiliary switch Long time CP31FS/씲W1D CP32FS/씲W1D CP33FS/씲W1D
for low level circuit Medium time CP31FM/씲W1D CP32FM/씲W1D CP33FM/씲W1D
and inertia delay device Instantaneous — — —
With alarm switch Long time CP31FS/씲K1 CP32FS/씲K1 CP33FS/씲K1
for low level circuit Medium time CP31FM/씲K1 CP32FM/씲K1 CP33FM/씲K1
Instantaneous CP31FI/씲K1 CP32FI/씲K1 CP33FI/씲K1
With alarm switch Long time CP31FS/씲K1D CP32FS/씲K1D CP33FS/씲K1D
for low level circuit Medium time CP31FM/씲K1D CP32FM/씲K1D CP33FM/씲K1D
and inertia delay device Instantaneous — — —
Note : 씲 Enter the rated current in the 씲 mark of the type number. 0.1A: 0.1, 0.3A; 0.3, 0.5A: 0.5 ------ 30A: 30
■ Dimensions, mm
1-pole 2-pole 3-pole
Mounting rail
35mm width IEC standard
ON
TRIP TRIP TRIP
indicator indicator
63
45
OFF
67
56
54
54
54
5
24.5
12 29.5 47 8.1 65 4
Mounting rail
35mm width IEC standard
27
Auxiliary 5
17.5max. Auxiliary 35 max. 52.5 max.
Auxiliary terminal M3.5
terminal M3.5
terminal M3.5 With Aux. switch
With Aux. switch
or alarm switch With Aux. switch
Auxiliary
Auxiliary Auxiliary terminal M3.5
terminal M3.5 terminal M3.5
With Aux. switch
With Aux. switch With Aux. switch ON
or alarm switch or alarm switch
TRIP
50.7
67
56
63
OFF
5
24.5
8.1 65 4
Panel drilling
54
54
54
■ Description
The CP31 and CP32 have a similar
functions to a molded case circuit
breaker and they can be used for
normal switching ON and OFF
operations while breaking both
overload and short-circuit currents. SH-956 SM-1392
They are available in two time-current
versions—an instantaneous and a Standard type With auxiliary switch Rail mounting
time-delay version. A suitable type
should be selected to match the ■ Time-delay tripping type
thermal and permissible current
requirements. Rated CP31 (1-pole) CP31D CP32D
These are recommended for sequential current Front mounting Rail mounting (1-pole) (2-pole)
(A) Type Type Type Type
control circuits, motor control circuits,
solenoid-operated valves, heaters and 0.3 CP31/0.3 CP31/0.3X CP31D/0.3 CP32D/0.3
solid-state applications. 0.5 CP31/0.5 CP31/0.5X CP31D/0.5 CP32D/0.5
1 CP31/1 CP31/1X CP31D/1 CP32D/1
■ Features 2 CP31/2 CP31/2X CP31D/2 CP32D/2
• Excellent arc interruption 3 CP31/3 CP31/3X CP31D/3 CP32D/3
5 CP31/5 CP31/5X CP31D/5 CP32D/5
Since the arc extinguisher uses a 7 CP31/7 CP31/7X CP31D/7 CP32D/7
loop blow-out system the arc is 10 CP31/10 CP31/10X CP31D/10 CP32D/10
rapidly extinguished. 15 CP31/15 CP31/15X CP31D/15 CP32D/15
• Highly visible handle indication ON 20 CP31/20 CP31/20X CP31D/20 CP32D/20
shows red and OFF or TRIP blue. 25 CP31/25 CP31/25X CP31D/25 CP32D/25
• When positioned at ON the operating 30 CP31/30 CP31/30X CP31D/30 CP32D/30
handle is completely housed inside
the molded case and does not
protrude.
This helps to prevent erroneous
operation. ■ Typical applications Time-delay tripping type
• Trip-free mechanism These CP31 and CP32 protectors are • Control circuits
• Also available with auxiliary switch used for normal on-off switching of the • Solenoid valves and motor circuits
SPDT. power supply while also providing • Heater circuits
• Two time-current versions— overload protection of the load circuits.
instantaneous operation and a time Instantaneous tripping type
delay type. Select the model best • Semiconductor circuits 08
suited to your protection needs. • SCR (Silicon controlled rectifier)
• CP31D and CP32D types are of front and triac circuits
and rail dual mounting. • Computer peripheral equipment
■ Type number nomenclature
Arc Loop
grid blow-out CP 3 1 ■ ■ / ■ X W DC
conductor
Basic type Applied circuit
Blank: AC
Frame size DC : DC
3: 30A
Optional accessory
Number of poles Blank: Without auxiliary switch
1: 1-pole W: With auxiliary switch
2: 2-pole (CP32D)
SM-1384
Mounting and connection (CP31 only)
Rated breaking capacity * Blank: Front mounting
Blank: 2.5kA at 250V AC front connection
ON OFF 1.5kA at 50V DC X: Rail mounting
(TRIP) D: 1kA at 250V AC
1kA at 50V DC Rated current
Auxiliary 0.3: 0.3A 7: 7A
swich Operating characteristics 0.5: 0.5A 10: 10A
Blank: Time-delay tripping 1: 1A 15: 15A
I: Instantaneous tripping 2: 2A 20: 20A
S: Long time-delay tripping (AC circuit only) 3: 3A 25: 25A
5: 5A 30: 30A
SH-956
* One and the same CP31D and CP32D can be used for both front mounting and rail mounting.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice 08/5
Circuit Protectors
CP31, CP31D, CP32D
10
Rated insulation voltage 250V AC, 50V DC 250V AC, 50V DC 6
4
(Ui) 2
Rated operational voltage 250V AC, 50V DC 250V AC, 50V DC
1
(Ue) 40
Rated current 0.3, 0.5, 1, 2, 3, 5, 7, 0.3, 0.5, 1, 2, 3, 5, 20
10, 15, 20, 25, 30A 7, 10, 15, 20, 25, 30A Time delay
Operating time
20
6 tripping type
4
Rated breaking 2500A at 250V AC 1000A at 250V AC 2
capacity 1500A at 50V DC 1000A at 50V DC Long time delay
1 tripping type
Second
0.6
Operating characteristic Time-delay tripping Time-delay tripping 0.4 Instantaneous
Instantaneous tripping Instantaneous tripping 0.2 tripping type
Max. total fault
Long time delay tripping Long time delay tripping 0.1 cleaning time
0.06
0.04
Ambient temperature –10˚C to +60˚C –10˚C to +60˚C 0.02
Dielectric strength 2000V AC 1min. 2000V AC 1min. 0.01
0.006
1 1.5 2 3 4 6 8 10 20 30 40 60 80 100
Mechanical durability 10000 operations 6000 operations
Electrical durability 10000 operations 6000 operations Multiple of rated current
200
Main contact Auxiliary contact Auxiliary contact ratings 160 Ref. temp.: 40°C
120
ON Resistive load: 1A 100
20 250V AC 80
21
Inductive load: 0.5A 60
30 Resistive load: 3A 40
125V AC
Inductive load: 1A
OFF or Trip 20
Resistive load: 1A -10 0 10 20 30 40 50 60
21 50V DC
30
Inductive load: 0.5A Ambient temp. (°C)
Resistive load: 2A
30V DC
Inductive load: 1A
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog
08/6 Information subject to change without notice
Circuit Protectors
CP31, CP31D, CP32D
■ Dimensions, mm
● CP31 ● CP31/W ● CP31/X
Front mounting type With auxiliary switch Rail mounting type
ON ON ON
54
46
60
64
54
46
60
64
OFF OFF OFF
5
8 max 21 8 21 max 21
25 6.5 65 25 max 10 55 6.5 65
6.5 65 3.5 (TH35-7.5AL)
11 (TH35-15AL)
Auxiliary
Panel
Panel terminal
M3.5 drilling
drilling
Mounting rail length: 900mm
54
54
Type Material Mounting pitch
7
(Screw size)
ø4.5 12 ø4.5 12
2-M4 (ø5) 2-M4 (ø5)
TH35-7.5AL Aluminium 200mm (M5)
Mass: Approx. 100g TH35-15AL Aluminium 400mm (M5)
Clamp TS-XT
12 Panel
Terminal M4 27.5 12 Terminal M4 27.5 Terminal
Mounting rail width Mounting rail width (25.5) M3
35mm IEC standard 35mm IEC standard
ON ON
ON
54
46
64
54
46
60
64
OFF OFF
(47)
54
46
62
70
OFF
5
max 21 8 max 21
25 6.5 65 6.5 65
25
3.5 (TH35-7.5AL) 3.5 (TH35-7.5AL) 25 4 Aux.swich
9
11 (TH35-15AL) 11 (TH35-15AL) max.
Auxiliary terminal
M3.5 6.5 60
Mounting hole Mounting hole 5
for front 25.5
for front
mounting mounting
54
54
R2 or less
7
C
47
62
L
ø4.5 12 ø4.5 12
2-M4 (ø5) 2-M4 (ø5)
Panel drilling Panel drilling
2-ø4
Mass: Approx. 100g Panel cutting
08
● CP32D ● CP32D/W
Front mounting/Rail mounting type With auxiliary switch Size of conductors
Mounting rail
width 35mm
Mounting rail
width 35mm
Type of Main Auxiliary
IEC standard IEC standard terminal terminal terminal
25 Terminal M4 27.5 25 Terminal M4 27.5
Terminal screw* M4 M3.5
Connectable 1.25–5.5mm2 1.25–2mm2
wire sizes
54
46
64
54
46
64
54
7
ø4.5 ø4.5
■ Ordering information
37
2-M4 (ø5) 37
2-M4 (ø5) Specify the following:
Panel drilling Panel drilling
1. Type number
Mass: Approx. 200g
■ Description
CP-P circuit protectors are ideal for
electronic circuit protection. The space
required per pole is approximately 30%
less than that for CP-E models allowing
significant space savings. Application at
any one of 12 rated currents in the range
0.3A to 25A is possible. CP-P circuit
protectors have been approved by CP31P CP32P CP33P CP31P-R
KKD09-086 KKD09-083 KKD09-099 AF99-297
and TÜV Standards.
■ Features
• The mounting space is approximately
■ Specifications
30% less than that required with CP-E
models, and the width per pole has Type CP31P CP32P CP33P CP31P-R
been reduced by approximately 15%.
• Conforms to IEC Standards. (Conforms Pole 1-pole 2-pole 3-pole 1-pole
to CE markings.) Rated insulation voltage (Ui) 250V AC 50/60Hz, 65V DC
• and TÜV approved.
• Operated with an easy-to-use toggle Rated operational voltage (Ue) 240V AC, 60V DC
handle. Rated current 0.3, 0.5, 0.75, 1, 2, 3, 5, 7.5, 10, 15, 20, 25A
• Male tab soldering, and right angle
terminals are available. Rated breaking capacity 1000A at 240V AC
■ Standards 1000A at 60V DC
(File No.E96846) Operating characteristic Long time delay, Medium time delay
TÜV (IEC)(R9750278) Short time delay, Instantaneous tripping
■ Accessories
● Auxiliary switch (Type W)
Tripping mechanism Hydraulic-magnetic
This switch is used for indicator lamp or Ambient temperature -10˚C to +60˚C
control circuit.
● Alarm switch (Type K) Electrical durability 10000 operations
This switch can be connected to a Terminals Main circuit Tab Right angle
warning lamp or buzzer to indicate when Auxiliary circuit Soldering Right angle
the circuit protector has been tripped.
Accessories Auxiliary switch (W, W1) Available
Auxiliary and alarm switches for low level Alarm switch (K, K1) Available
circuit are also available on request. Mass (Approx.) 40g 85g 130g 40g
(Type W1, K1)
■ Versions
Operating CP31P (1-pole) CP32P (2-pole) CP33P (3-pole)
characteristic Type Type Type
Applied circuit AC Long time CP31PS/ ■ CP32PS/ ■ CP33PS/ ■
Medium time CP31PM/ ■ CP32PM/ ■ CP33PM/ ■
Short time CP31PF/ ■ CP32PF/ ■ CP33PF/ ■
Instantaneous CP31PI/ ■ CP32PI/ ■ CP33PI/ ■
Applied circuit DC Long time CP31PS/ DC■ CP32PS/ DC■ CP33PS/ DC■
Medium time CP31PM/ DC■ CP32PM/ DC■ CP33PM/ DC■
Short time CP31PF/ DC■ CP32PF/ DC■ CP33PF/ DC■
Instantaneous CP31PI/ DC■ CP32PI/ DC■ CP33PI/ DC■
With standard Long time CP31PS/ W■ CP32PS/ W■ CP33PS/ W■
auxiliary switch Medium time CP31PM/ W■ CP32PM/ W■ CP33PM/ W■
Short time CP31PF/ W■ CP32PF/ W■ CP33PF/ W■
Instantaneous CP31PI/ W■ CP32PI/ W■ CP33PI/ W■
Applied circuit DC Long time CP31PS/ WDC■ CP32PS/ WDC■ CP33PS/ WDC■
Medium time CP31PM/ WDC■ CP32PM/ WDC■ CP33PM/ WDC■
Short time CP31PF/ WDC■ CP32PF/ WDC■ CP33PF/ WDC■
Instantaneous CP31PI/ WDC■ CP32PI/ WDC■ CP33PI/ WDC■
With standard Long time CP31PS/ K■ CP32PS/ K■ CP33PS/ K■
alarm switch Medium time CP31PM/ K■ CP32PM/ K■ CP33PM/ K■
Short time CP31PF/ K■ CP32PF/ K■ CP33PF/ K■
Instantaneous CP31PI/ K■ CP32PI/ K■ CP33PI/ K■
Applied circuit DC Long time CP31PS/ KDC■ CP32PS/ KDC■ CP33PS/ KDC■
Medium time CP31PM/ KDC■ CP32PM/ KDC■ CP33PM/ KDC■
Short time CP31PF/ KDC■ CP32PF/ KDC■ CP33PF/ KDC■
Instantaneous CP31PI/ KDC■ CP32PI/ KDC■ CP33PI/ KDC■
With auxiliary switch Long time CP31PS/ W1■ CP32PS/ W1■ CP33PS/ W1■
for low level circuit Medium time CP31PM/ W1■ CP32PM/ W1■ CP33PM/ W1■
Short time CP31PF/ W1■ CP32PF/ W1■ CP33PF/ W1■
Instantaneous CP31PI/ W1■ CP32PI/ W1■ CP33PI/ W1■
Applied circuit DC Long time CP31PS/ W1DC■ CP32PS/ W1DC■ CP33PS/ W1DC■
Medium time CP31PM/ W1DC■ CP32PM/ W1DC■ CP33PM/ W1DC■
Short time CP31PF/ W1DC■ CP32PF/ W1DC■ CP33PF/ W1DC■
Instantaneous CP31PI/ W1DC■ CP32PI/ W1DC■ CP33PI/ W1DC■
With alarm switch Long time CP31PS/ K1■ CP32PS/ K1■ CP33PS/ K1■
for low level circuit Medium time CP31PM/ K1■ CP32PM/ K1■ CP33PM/ K1■
Short time CP31PF/ K1■ CP32PF/ K1■ CP33PF/ K1■ 08
Instantaneous CP31PI/ K1■ CP32PI/ K1■ CP33PI/ K1■
Applied circuit DC Long time CP31PS/ K1DC■ CP32PS/ K1DC■ CP33PS/ K1DC■
Medium time CP31PM/ K1DC■ CP32PM/ K1DC■ CP33PM/ K1DC■
Short time CP31PF/ K1DC■ CP32PF/ K1DC■ CP33PF/ K1DC■
Instantaneous CP31PI/ K1DC■ CP32PI/ K1DC■ CP33PI/ K1DC■
Notes : Enter the rated current in the mark of the type number. 0.3A: 0.3, 0.5A: 0.5 ------ 25A: 25
■ Enter the main circuit terminal in the ■ mark.
CP3 1 P M / 0.3 W DC P
■ Characteristic curves
AC circuit
Long time delay (S) Medium time delay (M) Ambient temperature compensation
at 25˚C at 25˚C 300
1000 1000
200
Scale factor of operating time (%)
100 100
Max. value Ref. temp.: 25˚C
100
10 10 Max. value 80
60
Operating time (sec.)
1 1
40
Min. value
.1 .1
-10 0 10 20 25 30 40 50 60
.01 .01 Min. value
Ambient temp. (˚C)
.001 .001
100 200 300 400 500 600 700 800 9001000 100 200 300 400 500 600 700 800 9001000
Multiple of rated current (%) Multiple of rated current (%)
100 100
10 10
Operating time (sec.)
Operating time (sec.)
1 Max. value 1
.1 .1 Max. value
.01 .01
Min. value
Min. value
.001 .001
100 200 300 400 500 600 700 800 9001000 100 200 300 400 500 600 700 800 9001000
Multiple of rated current (%) Multiple of rated current (%)
■ Characteristic curves
DC circuit
Long time delay (S) Medium time delay (M)
at 25˚C at 25˚C
1000 1000
100 100
.1 .1
Min. value
.01 .01
Min. value
.001 .001
100 200 300 400 500 600 700 800 9001000 100 200 300 400 500 600 700 800 9001000
Multiple of rated current (%) Multiple of rated current (%)
100 100
10 10
Operating time (sec.)
Max. value
1 1
Max. value
.1 .1
.01 .01
08
■ Dimensions, mm
1-pole 2-pole 3-pole
32
32
20
20
20
16 16 16
With auxiliary
With auxiliary or alarm switch
or alarm switch With auxiliary Series trip
Series trip or alarm switch Aux. terminal (for aux. switch)
Series trip Main terminal Main terminal Thickness: 1 Width: 2.8
Thickness: 0.8, width: 6.3 Main terminal Main terminal Thickness: 0.8 Width: 6.3 Aux. terminal (for alarm)
Main terminal Thickness: 0.8 Width: 6.3 Thickness: 0.8 Width: 6.3
Thickness: 0.8 Width: 6.3 Aux. terminal Thickness: 1 Width: 2.8
Thickness: 1 Width: 2.8 Aux. terminal Main terminal
Thickness: 1, width: 2.8 Thickness: 0.8 Width: 6.3
42
42
42
42
42
42
View from back View from back View from back
50 16.9 50 16.9
3.5
3.5
7.8
8 3 8 3
LINE LINE
P
15.4
P
35
35
LOAD LOAD
8.7
38 38
42 5 42
32±0.2
20±0.2
20±0.2
20±0.2
+0.4 +0.4
+0.4
ø14 0 ø14 0
ø14 0
■ Dimensions, mm
Soldering terminal 1-pole 2-pole 3-pole
(With auxiliary terminal)
16.4 max. 32.6 max. 49 max.
16.9
Main terminal Thickness: 0.8 ø13.6 ø13.6 ø13.6
3
3.4
LINE
2.8
7.9
13.6
15.4
35.2
42
32
8.7
20
LOAD
38 16 16 16
4 43.6
1.2
12.5 min.
5.1
8
Printed board
1.2
5.1
Aux. terminal
7.9
0.5
1.25
15.4
35.2
8.7
3.4
1
2.85
5 1.2
4-ø1.9 Bracket
Not suppled.
Prease prepare it on
customer's side.
Right angle terminal
(With auxiliary terminal) 16.4 max. 0.8
16.9
Main terminal Thickness: 0.8 ø13.6 4
3 Panel drilling
3.4
12.5 08
1.2
LINE
6.25
9.6
13.6
12.5
35.2
15.2
42
32
7.6
20
1.2
9-ø1.9
LOAD
45.4
38
Handle center
42
13.6
5
35.2
4
1.2
1.2 0.5
0.8
5 45.4
4
A
A
1.2
50.4
■ Features
• Available with ratings from 0.3A to 50A.
• Conforms to IEC Standards. (Conforms
to CE markings.)
• and TÜV approved.
• Rated breaking capacity of 1,500A at
240V AC.
• Stud terminals used. CP51B CP52B CP53B
KKD09-084 KKD09-092 KKD09-096
■ Standards
(File No.E96846)
TÜV (IEC)(R9750278)
■ Accessories ■ Specifications
● Auxiliary switch (Type W)
This switch is used for ON-OFF lamp Type CP51B CP52B CP53B
indicator or control circuit. Pole 1-pole 2-pole 3-pole
● Alarm switch (Type K)
This switch can be connected to a Rated insulation voltage (Ui) 250V AC 50/60Hz, 65V DC
warning lamp or buzzer to indicate when
Rated operational voltage (Ue) 240V AC, 60V DC
the circuit protector has been tripped.
Rated current 0.3, 0.5, 0.75, 1, 2, 3, 5, 7.5, 10, 15, 20, 25, 30,
Auxiliary and alarm switch for low level 40, 50A
circuit are also available on request.
(Type W1, K1) Rated breaking capacity 1500A at 240V AC
1000A at 60V DC
Operating characteristic Long time delay, Medium time delay
Ratings of auxiliary and alarm Short time delay, Instantaneous tripping
switches
Tripping mechanism Hydraulic-magnetic
Standard type (Type W, K)
Ambient temperature -10˚C to +60˚C
250V AC Resistive load: 3A
Inductive load: 2A Electrical durability 10000 operations
125V AC Resistive load: 3A Terminals Main circuit Round stud
Inductive load: 2A Auxiliary circuit Soldering
30V DC Resistive load: 3A
Accessories Auxiliary switch (W, W1) Available
Inductive load: 2A
Alarm switch (K, K1) Available
C NO NC
OFF C NO NC
TRIP
C NO NC
C NO NC
■ Versions
Operating CP51B (1-pole) CP52B (2-pole) CP53B (3-pole)
characteristic Type Type Type
Applied circuit AC Long time CP51BS/ CP52BS/ CP53BS/
Medium time CP51BM/ CP52BM/ CP53BM/
Short time CP51BF/ CP52BF/ CP53BF/
Instantaneous CP51BI/ CP52BI/ CP53BI/
Applied circuit DC Long time CP51BS/ DC CP52BS/ DC CP53BS/ DC
Medium time CP51BM/ DC CP52BM/ DC CP53BM/ DC
Short time CP51BF/ DC CP52BF/ DC CP53BF/ DC
Instantaneous CP51BI/ DC CP52BI/ DC CP53BI/ DC
With standard Long time CP51BS/ W CP52BS/ W CP53BS/ W
auxiliary switch Medium time CP51BM/ W CP52BM/ W CP53BM/ W
Short time CP51BF/ W CP52BF/ W CP53BF/ W
Instantaneous CP51BI/ W CP52BI/ W CP53BI/ W
Applied circuit DC Long time CP51BS/ WDC CP52BS/ WDC CP53BS/ WDC
Medium time CP51BM/ WDC CP52BM/ WDC CP53BM/ WDC
Short time CP51BF/ WDC CP52BF/ WDC CP53BF/ WDC
Instantaneous CP51BI/ WDC CP52BI/ WDC CP53BI/ WDC
With standard Long time CP51BS/ K CP52BS/ K CP53BS/ K
alarm switch Medium time CP51BM/ K CP52BM/ K CP53BM/ K
Short time CP51BF/ K CP52BF/ K CP53BF/ K
Instantaneous CP51BI/ K CP52BI/ K CP53BI/ K
Applied circuit DC Long time CP51BS/ KDC CP52BS/ KDC CP53BS/ KDC
Medium time CP51BM/ KDC CP52BM/ KDC CP53BM/ KDC
Short time CP51BF/ KDC CP52BF/ KDC CP53BF/ KDC
Instantaneous CP51BI/ KDC CP52BI/ KDC CP53BI/ KDC
With auxiliary switch Long time CP51BS/ W1 CP52BS/ W1 CP53BS/ W1
for low level circuit Medium time CP51BM/ W1 CP52BM/ W1 CP53BM/ W1
Short time CP51BF/ W1 CP52BF/ W1 CP53BF/ W1
Instantaneous CP51BI/ W1 CP52BI/ W1 CP53BI/ W1
Applied circuit DC Long time CP51BS/ W1DC CP52BS/ W1DC CP53BS/ W1DC
Medium time CP51BM/ W1DC CP52BM/ W1DC CP53BM/ W1DC
Short time CP51BF/ W1DC CP52BF/ W1DC CP53BF/ W1DC
Instantaneous CP51BI/ W1DC CP52BI/ W1DC CP53BI/ W1DC
With alarm switch Long time CP51BS/ K1 CP52BS/ K1 CP53BS/ K1
for low level circuit Medium time CP51BM/ K1 CP52BM/ K1 CP53BM/ K1
Short time CP51BF/ K1 CP52BF/ K1 CP53BF/ K1 08
Instantaneous CP51BI/ K1 CP52BI/ K1 CP53BI/ K1
Applied circuit DC Long time CP51BS/ K1DC CP52BS/ K1DC CP53BS/ K1DC
Medium time CP51BM/ K1DC CP52BM/ K1DC CP53BM/ K1DC
Short time CP51BF/ K1DC CP52BF/ K1DC CP53BF/ K1DC
Instantaneous CP51BI/ K1DC CP52BI/ K1DC CP53BI/ K1DC
Note : Enter the rated current in the mark of the type number. 0.3A: 0.3, 0.5A: 0.5 ------ 50A: 50
CP5 1 B M / 0.3 W DC
Rated current
0.3: 0.3A 2: 2A 10: 10A 30: 30A
0.5: 0.5A 3: 3A 15: 15A 40: 40A
0.75:0.75A 5: 5A 20: 20A 50: 50A
1: 1A 7.5: 7.5A 25: 25A
■ Characteristic curves
AC circuit
Long time delay (S) Medium time delay (M) Ambient temperature compensation
300
at 25˚C at 25˚C
1000 1000
200
Scale factor of operating time (%)
100 100
Ref. temp.: 25˚C
Max. value 100
10 Max. value 80
10
60
Operating time (sec.)
1 1 40
.1 .1
-10 0 10 20 25 30 40 50 60
Min. value Min. value
.01 .01 Ambient temp. (˚C)
.001 .001
100 200 300 400 500 600 700 800 9001000 100 200 300 400 500 600 700 800 9001000
Multiple of rated current (%) Multiple of rated current (%)
100 100
10 10
Operating time (sec.)
Operating time (sec.)
1 Max. value 1
Max. value
.1 .1
.01 .01
Min. value
Min. value
.001 .001
100 200 300 400 500 600 700 800 9001000 100 200 300 400 500 600 700 800 9001000
Multiple of rated current (%) Multiple of rated current (%)
■Characteristic curves
DC circuit
Long time delay (S) Medium time delay (M)
at 25˚C at 25˚C
1000 1000
100 100
Max. value
10 10 Max. value
Operating time (sec.)
.1 .1
.01
Min. value .01 Min. value
.001 .001
100 200 300 400 500 600 700 800 9001000 100 200 300 400 500 600 700 800 9001000
Multiple of rated current (%) Multiple of rated current (%)
100 100
10 10
Operating time (sec.)
Max. value
1 1
Max. value
.1 .1
.01 .01
Min. value
Min. value
.001 .001
100 200 300 400 500 600 700 800 9001000 100 200 300 400 500 600 700 800 9001000
Multiple of rated current (%) Multiple of rated current (%)
08
■ Dimensions, mm
1-pole 2-pole 3-pole
4.45
19 19 19
4.45
52.5
52.5
52.5
M3 Depth 5 M3 Depth 5 M3 Depth 5
With auxiliary
With auxiliary With auxiliary or alarm switch
or alarm switch or alarm switch Aux. terminal (for aux. switch)
Aux. terminal Aux. terminal Thickness: 1 Width: 2.8
Series trip Thickness: 1 Width: 2.8 Series trip Thickness: 1 Width: 2.8 Aux. terminal (for alarm switch)
Series trip Thickness: 1, width: 2.8
63.5
63.5
63.5
18.3
7
18.3
17
P
15.4
49.5
P
49.5
8.7
18.3
18.3
M5 Stud
5 6
M5 Stud
+0.4 +0.4
Line side 38.4 0
57.6 0
Line side
4.35
+0.4
4.35
±0.2 ±0.2
4.35
+0.4
0
52.5±0.2
52.5±0.2
0
52.5±0.2
36.9
36.9
36.9
■ Description
CP-E, CP-V circuit protectors have been
specially developed for computers,
communication equipment and
peripheral applications. In these
situations power irregularities can lead to Socket
serious and expensive damage, and CP-S2
reliable protective equipment is required. SM-1393 SM-1376 SM-1382
CP32E
FUJI circuit protectors meet this need. CP31E with socket CP31V Rail mounting
These protectors are available with
ratings from 50mA to 30A. They are
widely used in FA, office machinery, ■ Specifications
communication equipment and industrial Type CP31E, V CP32E, V CP33E, V CP34E, V
computer-controlled equipment. They
are also suitable for extremely severe Pole 1-pole 2-pole 3-pole 4-pole
service since they can withstand Rated insulation voltage (Ui) 250V AC 50/60Hz, 65V DC
mechanical shocks up to 981m/s2. Rated operational voltage (Ue) 250V AC 50/60Hz, 60V DC
■ Features Rated current 0.05, 0.1, 0.25, 0.5, 0.75, 1, 2, 2.5, 3, 5, 7.5
• Available in instantaneous, short time, 10, 15, 20, 25, 30A
medium time and long time delay Rated breaking capacity 1000A at 250V AC
types, thus making them suitable for a 1000A at 60V DC
wide range of electronic applications. Operating characteristic Long time delay, Medium time delay
• Also available in types having inertia Short time delay, Instantaneous tripping
delay characteristics. These do not trip Tripping mechanism Hydraulic-magnetic
due to inrush current. Ambient temperature –10˚C to +60˚C
• For internal circuits, series trip, shunt Electrical durability 10000 operations
trip, relay trip and switch types are
Terminals Main circuit Tab, screw, printed board
available. Auxiliary circuit Tab, printed board
• Circuit protectors with an auxiliary and
Accessories Auxiliary switch (W, W1) Available
alarm switch are also available.
Alarm switch (K, K1) Available
• Single pole to 3-pole CP types can be Inertia delay device (D) Available
operated with a single handle. Handle
Mass (Approx.) 60g 120g 180g 240g
holes are easily made in panels.
• Widths down to 19mm.
Ratings of auxiliary and alarm switches Inertia delay characteristics
■ Standards
: CP-E, CP-V (File No. E96846), Resistive load: 3A
(File No. E83461 for switch type), Socket 250V AC
Inductive load: 2A 12000
08
CP-S (E96846SP, E83461, LR67978 Resistive load: 5A
(CSA C22.2 No.14)) 125V AC
Scale factor of rated current (%)
the circuit protector has been tripped. extremely large inrush current flows.
This inertia delay device is designed to 0 1 2 3 4 5 6 7 8 9 10
Auxiliary (W1) and alarm (K1) switch for prevent the circuit protector from Pulse time [ms]
low level circuit are also available on operating erroneously due to such inrush • Scale factor of the rated current (%)
request. current and to carry out an interruption
within the prescribed operating Peak value of pulse current
× 100
characteristics in the face of an Rated current for protector
overcurrent.
For instance, the following graph • Waveform of pulse current:
Sinusoidal wave or parabolic pulse
explains that the protector does not
operate even when a pulse current of
Peak
approx. 18 times (peak value) rated value of
current with a pulse width of 8ms flows. pulse current
Pulse time
■ Versions
Internal circuit Operating CP31E (1-pole) CP32E (2-pole) CP33E (3-pole) CP34E (4-pole)
characteristics Type Type Type Type
Series trip type Long time CP31E/ CP32E/ CP33E/ CP34E/
Medium time CP31EM/ CP32EM/ CP33EM/ CP34EM/
Short time CP31EF/ CP32EF/ CP33EF/ CP34EF/
Instantaneous CP31EI/ CP32EI/ CP33EI/ CP34EI/
Series trip type Long time CP31E/ D CP32E/ D CP33E/ D CP34E/ D
With inertia delay device Medium time CP31EM/ D CP32EM/ D CP33EM/ D CP34EM/ D
Short time CP31EF/ D CP32EF/ D CP33EF/ D CP34EF/ D
Instantaneous — — — —
Series trip type Long time CP31E/ W CP32E/ W CP33E/ W CP34E/ W
With auxiliary switch Medium time CP31EM/ W CP32EM/ W CP33EM/ W CP34EM/ W
Short time CP31EF/ W CP32EF/ W CP33EF/ W CP34EF/ W
Instantaneous CP31EI/ W CP32EI/ W CP33EI/ W CP34EI/ W
Series trip type Long time CP31E/ WD CP32E/ WD CP33E/ WD CP34E/ WD
With auxiliary switch Medium time CP31EM/ WD CP32EM/ WD CP33EM/ WD CP34EM/ WD
and inertia delay device Short time CP31EF/ WD CP32EF/ WD CP33EF/ WD CP34EF/ WD
Instantaneous — — — —
Series trip type Long time CP31E/ K CP32E/ K CP33E/ K CP34E/ K
With alarm switch Medium time CP31EM/ K CP32EM/ K CP33EM/ K CP34EM/ K
Short time CP31EF/ K CP32EF/ K CP33EF/ K CP34EF/ K
Instantaneous CP31EI/ K CP32EI/ K CP33EI/ K CP34EI/ K
Series trip type Long time CP31E/ KD CP32E/ KD CP33E/ KD CP34E/ KD
With alarm switch Medium time CP31EM/ KD CP32EM/ KD CP33EM/ KD CP34EM/ KD
and inertia delay device Short time CP31EF/ KD CP32EF/ KD CP33EF/ KD CP34EF/ KD
Instantaneous — — — —
Shunt trip type Long time CP31E2/ CP32E2/ CP33E2/ CP34E2/
Medium time CP31E2M/ CP32E2M/ CP33E2M/ CP34E2M/
Short time CP31E2F/ CP32E2F/ CP33E2F/ CP34E2F/
Instantaneous CP31E2I/ CP32E2I/ CP33E2I/ CP34E2I/
Shunt trip type Long time CP31E2/ D CP32E2/ D CP33E2/ D CP34E2/ D
With inertia delay device Medium time CP31E2M/ D CP32E2M/ D CP33E2M/ D CP34E2M/ D
Short time CP31E2F/ D CP32E2F/ D CP33E2F/ D CP34E2F/ D
Instantaneous — — — —
Relay trip type Long time CP31E3/ CP32E3/ CP33E3/ CP34E3/
(Current trip) Medium time CP31E3M/ CP32E3M/ CP33E3M/ CP34E3M/
Short time CP31E3F/ CP32E3F/ CP33E3F/ CP34E3F/
Instantaneous CP31E3I/ CP32E3I/ CP33E3I/ CP34E3I/
Relay trip type Long time CP31E3/ D CP32E3/ D CP33E3/ D CP34E3/ D
With inertia delay device Medium time CP31E3M/ D CP32E3M/ D CP33E3M/ D CP34E3M/ D
Short time CP31E3F/ D CP32E3F/ D CP33E3F/ D CP34E3F/ D
Instantaneous — — — —
Switch type CP31E4/30 CP32E4/30 CP33E4/30 CP34E4/30
Switch type CP31E4/30W CP32E4/30W CP33E4/30W CP34E4/30W
With auxiliary switch
Relay trip type CP31E5/30 CP32E5/30 CP33E5/30 CP34E5/30
(Shunt trip)
Dual coil type Long time CP31E6/ CP32E6/ CP33E6/ CP34E6/
Medium time CP31E6M/ CP32E6M/ CP33E6M/ CP34E6M/
Short time CP31E6F/ CP32E6F/ CP33E6F/ CP34E6F/
Instantaneous CP31E6I/ CP32E6I/ CP33E6I/ CP34E6I/
Dual coil type Long time CP31E6/ D CP32E6/ D CP33E6/ D CP34E6/ D
With inertia delay device Medium time CP31E6M/ D CP32E6M/ D CP33E6M/ D CP34E6M/ D
Short time CP31E6F/ D CP32E6F/ D CP33E6F/ D CP34E6F/ D
Instantaneous — — — —
Notes: Enter the rated current in the mark of the type number.
0.05A: 0.05, 0.1A: 0.1, 0.25A: 0.25......30A: 30
• When ordering types with auxiliary switch (W1) or alarm switch (K1), add suffix to type number.
■ Versions
Internal circuit Operating CP31V (1-pole) CP32V (2-pole) CP33V (3-pole) CP34V (4-pole)
characteristics Type Type Type Type
Series trip type Long time CP31V/ CP32V/ CP33V/ CP34V/
Medium time CP31VM/ CP32VM/ CP33VM/ CP34VM/
Short time CP31VF/ CP32VF/ CP33VF/ CP34VF/
Instantaneous CP31VI/ CP32VI/ CP33VI/ CP34VI/
Series trip type Long time CP31V/ D CP32V/ D CP33V/ D CP34V/ D
With inertia delay device Medium time CP31VM/ D CP32VM/ D CP33VM/ D CP34VM/ D
Short time CP31VF/ D CP32VF/ D CP33VF/ D CP34VF/ D
Instantaneous — — — —
Series trip type Long time CP31V/ W CP32V/ W CP33V/ W CP34V/ W
With auxiliary switch Medium time CP31VM/ W CP32VM/ W CP33VM/ W CP34VM/ W
Short time CP31VF/ W CP32VF/ W CP33VF/ W CP34VF/ W
Instantaneous CP31VI/ W CP32VI/ W CP33VI/ W CP34VI/ W
Series trip type Long time CP31V/ WD CP32V/ WD CP33V/ WD CP34V/ WD
With auxiliary switch Medium time CP31VM/ WD CP32VM/ WD CP33VM/ WD CP34VM/ WD
and inertia delay device Short time CP31VF/ WD CP32VF/ WD CP33VF/ WD CP34VF/ WD
Instantaneous — — — —
Series trip type Long time CP31V/ K CP32V/ K CP33V/ K CP34V/ K
With alarm switch Medium time CP31VM/ K CP32VM/ K CP33VM/ K CP34VM/ K
Short time CP31VF/ K CP32VF/ K CP33VF/ K CP34VF/ K
Instantaneous CP31VI/ K CP32VI/ K CP33VI/ K CP34VI/ K
Series trip type Long time CP31V/ KD CP32V/ KD CP33V/ KD CP34V/ KD
With alarm switch Medium time CP31VM/ KD CP32VM/ KD CP33VM/ KD CP34VM/ KD
and inertia delay device Short time CP31VF/ KD CP32VF/ KD CP33VF/ KD CP34VF/ KD
Instantaneous — — — —
Shunt trip type Long time CP31V2/ CP32V2/ CP33V2/ CP34V2/
Medium time CP31V2M/ CP32V2M/ CP33V2M/ CP34V2M/
Short time CP31V2F/ CP32V2F/ CP33V2F/ CP34V2F/
Instantaneous CP31V2I/ CP32V2I/ CP33V2I/ CP34V2I/
Shunt trip type Long time CP31V2/ D CP32V2/ D CP33V2/ D CP34V2/ D
With inertia delay device Medium time CP31V2M/ D CP32V2M/ D CP33V2M/ D CP34V2M/ D
Short time CP31V2F/ D CP32V2F/ D CP33V2F/ D CP34V2F/ D
Instantaneous — — — —
Switch type CP31V4/30 CP32V4/30 CP33V4/30 CP34V4/30
Switch type CP31V4/30W CP32V4/30W CP33V4/30W CP34V4/30W
With auxiliary switch
Notes: Enter the rated current in the mark of the type number.
0.05A: 0.05, 0.1A: 0.1, 0.25A: 0.25......30A: 30
• When ordering types with auxiliary switch (W1) or alarm switch (K1), add suffix to type number.
08
■ Ordering information
Specify the following:
1. Type number
(Including rated tripping voltage)
■ Dimensions, mm
● Series trip and switch types
Tab terminal
CP31E, CP31E4 CP31V, CP31V4 1-pole 2-pole 3-pole 4-pole
53 19 max. 38.5 max. 57.5 max. 76.5 max.
53
φ 15 φ 15 φ 15 φ 15
6
7 9 11.5
6
LINE
7 9 11.5
LINE
39
39
*2
*2
42
*1
*1
42
26.5
26.5
LOAD
LOAD
Screw terminal
Panel drilling
53 18 max.
1-pole 2-pole 3-pole 4-pole
5 6 42 3.3 2-ø4 4-ø4 4-ø4 4-ø4
Line side
LINE
42 ±0.2
26.5±0.2
Load side
19 ±0.2 19 ±0.2 19 ±0.2 56.4 ±0.2
LOAD
Main terminal M4 × 8
Thickness: 0.8
Width: 6.3
● Shunt trip type Socket for rail mounting (CP-E/Series trip and switch types)
Tab terminal
1-pole 2-pole
(78) 19 Main 38
28 (32) terminal 19
6
LINE M4
21
29
21
LINE
10
C 21
LOAD
NO 20 C
LINE
21 08
77
84
93
NC 30
NO 20
LOAD
NC 30
● Relay trip type (CP-E only) LOAD
Tab terminal
Circuit protector 30 30
LINE
15
20
19
Mounting rail
35mm width IEC standard
10
LOAD
Terminal arrangement
Common
51
51
51
51
NO
NC
■ Characteristic curves
AC circuit
Long time dealy (S) Medium time delay (M) Short time delay (F)
at 25˚C at 25˚C at 25˚C
1000 1000 1000
Max. value
10 10 10
Max. value
1 1 1 Max. value
Min. value
0.1 0.1 0.1
Min. value
AC circuit DC circuit
Instantaneous (I) Long time delay Medium time delay (M)
at 25˚C at 25˚C at 25˚C
1000 1000 1000
Max. value
10 10 10
Operating time (sec.)
Max. value
1 1 1
Min. value
0.001 0.001 0.001
100 200 300 400 500 600 700 800 900 1000 100 200 300 400 500 600 700 800 900 1000 100 200 300 400 500 600 700 800 900 1000
Multiple of rated current (%) Multiple of rated current (%) Multiple of rated current (%)
DC circuit
Short time delay (F) Instantaneous (I)
at 25˚C at 25˚C
1000 1000
100 100
Ambient temperature compensation
10 10
Operating time (sec.)
300
Scale factor of operating time (%)
200
1 Max. value 1
Ref. temp.: 25˚C
100
0.1 0.1 Max. value 80
60
Min. value
0.01 0.01
40
Min. value
0.001 0.001
100 200 300 400 500 600 700 800 900 1000 100 200 300 400 500 600 700 800 900 1000
-10 0 10 20 25 30 40 50 60
Multiple of rated current (%) Multiple of rated current (%) Ambient temp. (˚C)
■ Description
FUJI low voltage current-limiting fuses
are designed to give protection to power
supply and distribution circuits and
equipment such as motor starter and
semiconductors.
AF97-635,634
Since they can be supplied in a variety
of types and ratings any circuit BLC, CR and CS type
capacities can be accurately matched. Super Rapid Fuses
FUJI current-limiting fuses have a high These fuses are used exclusively for the
interrupting capacity and will prevent protection of semiconductors, thyristors
thermal and mechanical damage from and silicon diodes. Since their total
heavy short circuits. clearing I2t is very small protective
coordination with semi-conductors is
very easily carried out.
■ Rated current:
BLC type: 12 – 140 Amps
CR type: 30 – 600 Amps
CS type: 40 – 4700 Amps
For further information see page 08/31.
AF97-635,634
■ Quick selection table (CS fuse: Typical value)
AFaC and BaC type current-limiting Series Voltage Interrupting capacity rms sym (kA) Application
fuses 20 35 50 100 200
These fuses have a high interrupting
capacity of 100kA at 600V AC or DC AFaC 600V AC DC 3 to 100 Amps General use
and are suitable for power and control BaC 125 to 200 Amps
circuits. The fuse is a plug-in type, and 250 to 400 Amps
it can easily be replaced by removing a
FCF 500V AC 1 to 60 Amps General use
screw cap.
■ Rated current: 3 – 400 Amps FCK 500V AC 3 to 600 Amps
For further information see page 08/26. BLC 550V AC 12 to 140 Amps Semi-
CR2L(S) 250V AC 10 to 600 Amps conductor
protection
CR6L 600V AC 20 to 600 Amps
CS5F 500V AC 40 to 1500 Amps
CS10F 1000V AC 80 to 1500 Amps
CS15F 1500V AC 450 to 1250 Amps
AF97-642
08
FCF and FCK type current-limiting
fuses
These fuses are provided with special
links with low-temperature melting
characteristics, and are suitable for
general power circuits because of their
high interrupting capacity and good
current-limiting performance.
They are available in two types, a
center-blade type and a solid ferrule
type, with an insulated fuse body of high
quality porcelain.
■ Rated current: 1 – 600 Amps
For further information see page 08/29.
base, screw cap, fuse link and adapter Rear bushing Terminal (load)
can easily and safely be replaced by Thickness of mounting plate: 3.2mm or less
Beae
AF90-316
08
AF97-644
■ Characteristic curves
Melting time-current characteristic Permissible time-current characteristic Current-limiting characteristic
Minute
Minute
Time
Second
Second
BLA040 40 50 10 27 16 47
A
BLA060 60 50 10 27 20 62
B
B
D
D
A
D1
K
Type A B B1 C D D1 øE G H K L M M1 Y1 Y2 Mass
(max.) (max.) (g)
L (Load) AFaC-3 to 30 34 42 55 46.5 24 22 5 78.5 10 32 M5 18 24 22 22 100
G
45˚
(2-ø14)
A
E
F
B
K
G
Type A B C D E F G H K øL Mass
C
209 max
102 max
160 Panel drilling
Panel drilling 102 max
139.5 max
M12×30 2-PF1/4
139.5 max
4-M6 (2-ø26)
103
83
103
83
51
70
15
90
140 140
140
160 209 max
( ) :In the case the steel plate is used PF1/4(ø13)
■ Description
FCF and FCK HRC fuses use a SD-240 AF97-643
specially designed low-temperature FCF series fuse-link FCK series fuse-link Blown fuse indicator
melting element, a feature of 'dual
element' fuses. There is no fuse
deterioration due to overcurrent excellent thermal and mechanical
phenomena such as rush current at the characteristics and is packed in silica
time of motor starting and they also sand which prevents arcing. Thus
feature time-lag operation there are no fears of explosion or
characteristics. They operate rapidly production of noxious gases. The
and positively in the face of destructive FCF's link end is a solid ferrule-type
short circuit currents. Since they are and available in 1 – 60 Amps ratings. T-7
current-limiting fuses with a high The FCK is a center blade-type and
capacity of 50kA (FCF types: 1 – 60 available in 3 – 600 Amps ratings. ■ Ordering information
Amps) they are suitable for many types The fuse links for the 75 Amps FCK Specify the following:
of power and control circuits. The fuse and larger sizes are provided with a 1. Type number
link is housed in a ceramic barrel with blown fuse indicator.
0
5
ø2
ø1
3 FCF2-3
5 FCF2-5
13.5 13.5
10 FCF2-10 16.5 16.5
15 FCF2-15 50
75
20 FCF2-20
30 FCF2-30
40 FCF2-40 Mass: 20g Mass: 80g
50 FCF2-50
60 FCF2-60
● Fuse-link
Note: Minimum ordering quantity FCK2-3 to 600
Fuse-link: 100 pcs.
E C
FCK series
08
Rated Interrupting Fuse-link
D
current capacity
(A) (kA) Type
B A B
3 35 FCK2-3
5 FCK2-5
10 FCK2-10
15 FCK2-15
20 FCK2-20
30 FCK2-30 Type A B C D E Mass (g)
FCK2-3 to 30 50 15 ø19.8 13 66.5 35
40 FCK2-40 FCK2-40 to 60 75 19 ø24.9 16 96 95
50 FCK2-50 FCK2-75, 100 95 25 ø31 20 122.5 180
60 FCK2-60 FCK2-125 to 200 110 35 ø45 30 148.5 470
FCK2-250 to 400 120 50 ø63 40 170 1100
75 FCK2-75 FCK2-500, 600 145 60 ø75 50 205 2000
100 FCK2-100
125 FCK2-125
150 FCK2-150
200 FCK2-200
250 FCK2-250
300 FCK2-300
400 FCK2-400
500 FCK2-500
600 FCK2-600
Note: Minimum ordering quantity
Fuse-link: 100 pcs.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice 08/29
Low Voltage Fuses
FCF and FCK types
■ Characteristic curves
● FCF type ● FCK type
Melting time-current characteristic Melting time-current characteristic
Minute
Minute
Second
Time
Second
Current (A)
Second
Time
Second
Time
Current (A)
Current (A)
■ Description
The FUJI BLC, CR and CS types are
extremely reliable fuses which have
been specially developed to provide
protection for silicon diodes and
thyristors and are suitable for inverters
using semiconductors or transformers- SD-36 SM-388 SI-431 SI-429
rectifiers. FUJI Super Rapid Fuses are BLC CR2L CS5F CS10F
designed with a very small total I 2 t
value which gives them a high speed
interrupting action in the face of semiconductors short or circuits fail the • High interrupting capacity of 200kA
abnormal currents. sound elements will be quickly isolated at 1000V AC
In addition the arc voltage generated at from the fault circuits. • The CS type is provided with a blown
the time of interruption has a low value fuse indicator. An alarm contact
so that faults will not influence related ■ Features block (1NO or 1NC) can also be
electric machinery and equipment. • The total clearing I 2t is small and the attached.
These fuses can carry out the semiconductor circuit is completely
protection of many types of circuits protected. ■ UL recognized: CR2L/UL,CR2LS/UL,
rating from the semiconductor • Since the peak arc voltage at the CR6L/UL
overcurrents to destructive short- time of interruption is low damage to (File No. E92312)
circuiting faults-i.e. when the other equipment does not occur. CSA certificated: CR2LS/UL
(File No. LO4000-4090)
TÜV: CR2LS/UL (10-100A),
CR2L/UL (150-350A)
(Rep. No. E9450643E02)
CR6L/UL (50-300A)
(Rep. No. E9560543E02)
■ Specifications
Rated Rated Peak Max. Watt Fuse-link Rated Rated Peak Max. Watt Fuse-link
current voltage arc interrupting I2t loss current voltage arc interrupting I2t loss
voltage (Amp ×sec.)
2
voltage (Amp2×sec.)
× 103 Type × 103 Type
(A) (V) (W) (A) (V) (W)
12 550V 1550 0.09 5.1 BLC012-1 10 250V Max. 0.04 1.2 CR2LS-10
20 AC 1550 0.27 8.5 BLC020-1 20 AC 500 0.17 3.0 CR2LS-20
23 1550 0.39 10 BLC023-1 30 0.35 4.0 CR2LS-30
45 1380 1.8 19 BLC045-1 50 0.85 6.0 CR2LS-50
75 1250 5 32 BLC075-1 75 2.3 9.0 CR2LS-75 08
90 1250 11.5 38 BLC090-1 100 4.0 12.0 CR2LS-100
120 1200 33 51 BLC120-1 20 600V Max. 0.14 4.0 CR6L-20
140 1200 100 59 BLC140-1 30 AC 1200 0.35 7.0 CR6L-30
30 250V Max. 0.35 4.0 CR2L-30 50 1.8 9.0 CR6L-50
50 AC 500 0.85 6.0 CR2L-50 75 3.0 12.5 CR6L-75
75 2.3 9.0 CR2L-75 100 7.0 15 CR6L-100
100 4.0 12.0 CR2L-100
125 6.5 14.0 CR2L-125 150 18 22.0 CR6L-150
140 7.0 16.0 CR2L-140 200 30 34.0 CR6L-200
150 9.5 18.0 CR2L-150 250 70 37.0 CR6L-250
175 13 21.0 CR2L-175 300 95 40.0 CR6L-300
200 17 23.0 CR2L-200 350 150 45.0 CR6L-350
225 22 26.0 CR2L-225 400 200 55 CR6L-400
260 27 30.0 CR2L-260 500 390 60 CR6L-500
300 38 35.0 CR2L-300 600 700 70 CR6L-600
325 49 37.0 CR2L-325 Interrupting capacity
350 60 37.0 CR2L-350 CR2LS . 100kA at 250V AC
400 103 39.0 CR2L-400 CR6L .... 100kA at 600V AC
450 140 46.0 CR2L-450
500 160 48.0 CR2L-500
550 200 51.0 CR2L-550
600 215 56.0 CR2L-600
Interrupting capacity
BLC ...... 100kA at 550V AC
CR2L .... 100kA at 250V AC
C
øD
øD øD
A
A
E
A
B
B
ød ød ød Mounting hole a × b
H F
G
BLC023-1 23 50 10 13 14 Violet 12
BLC045-1 45 50 10 27 20 White 62 A
BLC075-1 75 63 6 34 5 Silver 120
BLC090-1 90 63 6 34 8 Red 120 Type A B C D E a×b F G H Mass
BLC120-1 120 63 6 47 8 Yellow 120
BLC140-1 140 63 6 47 8 Light red 215 CR2L-30 80 58 18 21.5 37 9×11 90 1.5 26.5 42g
CR2L-50
Note: The BLC type fuse link requires a holder in use. The size of the CR2L-75 80 58 20 30.5 44 9×11 90 3 32.5 100g
holder differs according to the fuse ratings. Select the most suitable CR2L-100
one after referring to the Table on page 08/40. CR2L-125
For drawings see page 08/28.
CR2L-140
CR2L-150
CR2L-175
CR2L-200 85 60 25 33.5 47 11×13 93 3.2 33.5 130g
CR2L-225
■ Ordering information CR2L-260
Specify the following: CR2L-300
1. Type number CR2L-325
CR2L-350 95 70 30 42 54 11×13 98 4 39 220g
■ Type number nomenclature CR2L-400
CR2L-450
BLC 012-1
CR2LS-10 56 42 12 18.5 34.5 6.5×8.5 78 2 25 28g
Rated current: 12 to 140A
CR2LS-20
Plug-in type super rapid fuse CR2LS-30
CR2LS-50
CS 10F-1000 -P/ UL CR2LS-75
UL recognized (CR2L, CR2LS, CR6L) CR2LS-100
CSA certificated (CR2LS) 08
TÜV (CR2LS, CR2L, CR6L) ● CR2L-500 to -600
84 70
2-fuse connected parallel
31
28
Note: The dimensions of the fuses with suffix. UL are the same as those of the
standard ones.
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice 08/33
Low Voltage Fuses
BLC, CR and CS types
Super Rapid Fuses
■ Dimensions, mm
● CR6L-20, CR6L-30, CR6L-50 ● CR6L-75 to 300 B
● CR6L-350 to 600
62 84 B
D
18.5 47
ø37
46.5
30
54
28
ø17.5
C
12
E
27
34.5
18
25 88 F
Blown indication
74 fuse (G type)
8
Blown indication
fuse (G type)
2
G
76 C
Mass: 42g A A
7
Blown fuse
indicator
D
D
7
84 max.
C
54.5
N.P.
30
A
A
30
72
A B
A B
72 51
2-MIO M
Mass: 800g
7
Alarm contat block
M10
7
max.77
Minute
54.5
N.P.
72
40
H
L
Time
5
72 ø15
86
158
Second
Voltage Type H L Mass (g)
500V CS5F-1000-P 51 69 1900
CS5F-1200-P
1000V CS10F-800-P 74 92 2420
CS10F-1000-P
CS10F-1250-P
1500V CS15F-900-P 105 123 3100 Current (A)
CS15F-1250-P
Time
Alarm
5
contat
block 107
M10
108 89.5
Second
08
40
72
ø15 72
Current-limiting characteristic
Max. Let-through current (Peak value) kA
■ Characteristic curves
CR2L, CR2LS CR6L
Melting time-current characteristic Melting time-current characteristic
CR6L-100
CR6L-150
CR6L-200
CR6L-250
CR6L-300
CR6L-350
CR6L-400
CR6L-500
CR6L-600
CR6L-20
CR6L-30
CR6L-50
CR6L-75
Minute
Minute
Time
Time
Second
Second
Minute
CR6L-100
CR6L-150
CR6L-200
CR6L-250
CR6L-300
CR6L-350
CR6L-400
CR6L-500
CR6L-600
CR6L-20
CR6L-20
CR6L-20
CR6L-20
CR6L-30
CR6L-50
CR6L-75
Time
Time
Second
Second
Available current (Sym, rms) I eff. (kA) Available current (Sym, rms) I eff. (kA)
■ Characteristic curves
CS1F CS2F
Melting time-current characteristic Melting time-current characteristic
Minute
Minute
Time
Time
Second
Second
Minute
Time
Time
Second
Second
08
Available current (Sym, rms) I eff. (kA) Available current (Sym, rms) I eff. (kA)
■ Characteristic curves
CS5F CS8F
Melting time-current characteristic Melting time-current characteristic
Minute
Minute
Time
Time
Second
Second
Current ( × 10A)
Current ( × 103A)
Minute
Time
Time
Second
Second
Current ( × 10A)
Current ( × 103A)
■ Characteristic curves
CS10F CS15F
Melting time-current characteristic Melting time-current characteristic
Minute
Minute
Time
Time
Second
Second
Current ( × 10A)
Current ( × 103A)
Minute
Time
Time
Second
Second
08
Current ( × 10A)
Current ( × 103A)
■ Operating indication
● Blown fuse indication Fig. 1 Fig. 3
FUJI Super Rapid Fuses are available
in BLC, CR and CS types. These types
have different methods of indicating a
blown fuse.
● BLC type
A blown fuse is indicated by the color
tip on the ferrule of the fuse being Alarm contact block
ejected as shown in Fig. 1. This can be AHX2905, 2915
seen through the window of the fuse
SD-36
holder. BLC type
● CR type
CS10F
This fuse does not have a blown Fig. 2 Line
SM-385
■ Fuse holder for BLC type fuse Fuse link Rated Base Screw cap Adaptor
FUJI BLC fuses require special current Surface Rear ring
holders. Select the most suitable one connection connection
which corresponds to the rated current Type (A) Type Type Type Type
of the fuse.
BLC012-1 12 AFa30 Ba30 Pa30 R20
Dimensions: See page 08/28. BLC020-1 20 AFa30 Ba30 Pa30 –
BLC023-1 23 AFa30 Ba30 Pa30 –
BLC045-1 45 AFa60 Ba60 Pa60 –
BLC075-1 75 AFa100 Ba100 Pa100 R75
BLC090-1 90 AFa100 Ba100 Pa100 –
BLC120-1 120 AFa200 Ba200 Pa200 –
BLC140-1 140 AFa200 Ba200 Pa200 –
SD-36 AF88-439
Method of application Remarks: The 'a' is a coefficient where the regulation of the AC input voltage is taken into account. This
Semiconductor rectifier equipment has is a=1.1 in case of voltage regulation ±10%.
a variety of rectifier circuits. Taking the
3-phase bridge rectifier circuit as an Fig. 2 Element current and line current
example – Fig. (a) and (b) as shown in Wire connection Wiring diagram Element fuse method Line fuse method
the following. type Element current Ia Line current I
Although the number of fuses used in
the line fuse method (a) is half the Id
Id
Ia Ia = __ I =d
number used in the element fuse Single-phase bridge I √2
method (b), the fuses must have a = 0.707d
larger current capacity.
I Id Id 2
Ia = __ I = Id
3-phase bridge Ia √3 3
= 0.577dI = 0.816dI
Ia Id Id__
I I = Ia =
3-phase, double star 2√ 3
= 0.289dI
● Rated current The I2t data for silicon diodes or Let-thru peak current (Instantaneous):
The current values in fuses in the line thyristor elements are normally given in 11,600 Amps
fuse system and the element fuse their respective catalogs. If the A 2S Let-thru R.M.S. current
system are different. Obtain the data is not given in their catalog obtain 11,600 ÷ 1.7 = 6,800 Amps
correct current value from the table on the value in the following manner. If This example clearly shows that while
page 08/41 (Fig. 2). protection is needed for a 250V, 150A a 100kA (rms, sym) current is
When selecting the rated current of a (Io) diode having a maximum allowable available, the fuse limits the current let-
fuse choose a fuse having an peak half sine wave current of 2700A, it thru to 6,800 Amperes (rms, sym).
amperage rating greater than the is important that the fuse has a total I 2 t
current which flows in the semi- value lower than that of the diode.
conductor if the load is continuous and Peak let-thru current
a fixed current. Calculation (Actual short-circuit current)
If the current which flows in the
Peak current of first half cycle
semiconductor is greater than the rated Maximum I2t diode = ( 1 Peak )2 0.0167 of available peak current
current of the fuse connect the fuses in 2
(AC component)
parallel. However, in this case, if the = ( 2700 )2 0.0167
2 Short circuit current that
numbers of fuses arranged in parallel would pass without current-
are 'n', then the I2t value of the fuse will = 30,400A2 Sec. limiting fuse.
be n2·I2t and n2 times the I2t value of DC component
one fuse. This should be taken into From the table (Page 08/38), the fuse
Current
consideration when protective with a total I2t nearest to 30,400A2 Sec.
coordination is taken into account. is the 260 Ampere fuse (CR 2L-260).
In the case of the circuit where the load
rapidly varies the fuse element will ■ Interrupting current
suffer from mechanical deterioration The rated interrupting current of the
and be damaged by thermal stress. fuse must exceed the maximum value Time
In loads of this type the deterioration (Symmetrical RMS value) of the M A
characteristics of the fuse must be estimated circuit fault current.
closely considered. T
M:Melting time
Moreover if the fuse current – time ■ Peak arc voltage A :Arcing time
characteristics of the fuse selected is In the case of the current-limiting fuse T :Total clearing time
less than the overload characteristics an arc voltage (overvoltage) is
of the semiconductor element then generated at the time of interruption
Let-thru peak current(Amperes)-Peak
=1
Pf
However, if the semiconductor element It is necessary to check that this peak Available
nt
has a large capacity then protective arc voltage does not exceed the 105,000
rre
cooperation is very difficult to arrange. semiconductor's maximum (Non- cu
ak
The fuses are used to isolate the repetitive peak) reverse voltage value.
pe
2
■ Total clearing I t value does not exceed the allowable
in
e
The total clearing I 2 t of fuse is a very 1/2 cycle surge current of the
bl
la
Since the user's product information, specific use application, and conditions of use are all outside of Fuji Electric FA
Components & Systems'control, it shall be the responsibility of the user to determine the suitability of any of the
products mentioned for the user's application.
Except to the extent otherwise provided for in the Conditions of Sale issued by Fuji Electric FA, Fuji Electric FA
warrants that the Fuji Electric FA products identified in this catalog shall be free from significant defects in materials
and workmanship provided the product has not been: 1) repaired or altered by others than Fuji Electric FA; 2) subjected
to negligence, accident, misuse, or damage by circumstances beyond Fuji Electric FA's control; 3) improperly operated,
maintained or stored; or 4) used in other than normal use or service. This warranty shall apply only to defects appearing
within one (1) year from the date of shipment by Fuji Electric FA, and in such case, only if such defects are reported
to Fuji Electric FA within thirty (30) days of discovery by purchaser. Such notice should be submitted in writing to Fuji
Electric FA at 5-7, Nihonbashi Odemma-cho, Chuo-ku, Tokyo, Japan. The sole and exclusive remedy with respected to
the above warranty whether such claim is based on warranty, contract, negligence, strict liability or any other theory,
is limited to the repair or replacement of such product or, at Fuji Electric FA's option reimbursement by Fuji Electric
FA of the purchase price paid to Fuji Electric FA for the particular product. Fuji Electric FA does not make any other
representations or warranties, whether oral or in writing, expressed or implied, including but not limited to any
warranty regarding merchantability or fitness for a particular purpose. Except as provided in the Conditions of
Sale, no agent or representative of Fuji Electric FA is authorized to modify the terms of this warranty in writing or orally.
In no event shall Fuji Electric FA be liable for special, indirect or consequential damages, including but not limited to,
loss of use of the product, other equipment, plant and power system which is installed with the product, loss of profits
or revenues, cost of capital, or claims against the purchaser or user of the product by its customers resulting from
the use of information, recommendations and descriptions contained herein. The purchaser agrees to pass on to its
customers and users, in writing at the time inquiries and orders are received by buyer, Fuji Electric FA's warranty as set
forth above.
Circuit Protectors
08 Low Voltage Current-Limiting Fuses
LOW
VOLTAGE
EQUIPMENT BLC, CR and CS types
Up to 600 Volts Super Rapid Fuses
INDIVIDUAL CATALOG
from D&C CATALOG 20th Edition 08 INDIVIDUAL CATALOG
from D&C CATALOG 20th Edition
01 02 03 04 05 06 07 08 09 10 11 12
08
5-7, Nihonbashi Odemma-cho, Chuo-ku, Tokyo, 103-0011, Japan
URL http://www.fujielectric.co.jp/fcs/eng