HITACHI OIL-FREE SCREW COMPRESSOR

Russian Federation Canada


OIL FREE SCREW
Germany
Korea
SINGLE STAGE / TWO STAGE
U.S.A
China Japan
India
Mexico
Thailand Philippines
Philippine
Viet Nam
Malaysia
Singapore
Indonesia

Australia

Asia & Oceania India Singapore Europe


Australia Hitachi India Pvt. Ltd. Hitachi Asia Ltd. Germany
Hitachi Australia Pty Ltd. Units 304-306, 3rd Floor, ABW Elegance (Industrial Components & Equipment Hitachi Europe GmbH
Level 8, 123 Epping Road, Macquarie Tower, Jasola District Centre, New Delhi Group) (Industrial Components & Equipment
Park NSW 2113 110 025, India 24 Jurong Port Road Group)
TEL : +61 (2) 9888-4100 TEL : +91 (11) 4060-5252 #03-05 CWT Distripark Am Seestern 18 (Euro Center)
FAX : +61 (2) 9888-4188 FAX : +91 (11) 4060-5253 Office Block D-40547 Düsseldorf
Singapore 619097 TEL : +49 (211) 5283 0
China Indonesia TEL : +65-6305-7400 FAX : +49 (211) 5283 649
Hitachi (China) Ltd. (Beijing office) Hitachi Asia Ltd. (Jakarta Office) FAX : +65-6305-7401
18th Floor Beijing Fortune Building Menara BCA 38th Floor Suite #3804 & Russian Federation
5 Dong San Huan Bei Lu Chao Yang 3805 JI.M.H Thamrin No.1 Jakarta 10310 Thailand Hitachi, Ltd. (Moscow Office)
District, Beijing 100004 TEL : +62 (21) 2358-6757 Hitachi Asia (Thailand) Co., Ltd. Millenium House, 12, Trubnaya, Moscow
TEL : +86 (10) 6590-8111 FAX : +62 (21) 2358-6755 18th Floor, Ramaland Building, 952 103045
FAX : +86 (10) 6590-8110 Rama IV Road Bangrak, Bangkok 10500 TEL : +7 (095) 787-4022, -4020
(Shanghai Office) Malaysia TEL : +66 (2) 632-9292 FAX : +7 (095) 787-4021
(Hitachi (Shanghai) Trading Co., Ltd.) Hitachi Asia (Malaysia) Sdn. Bhd. FAX : +66 (2) 632-9299
(Industrial Equipment Systems Division) Suite 17.3, Level 17, Menara IMC Latin America
12th Floor, Rui Jin Building No. 205, (Letter Box No.5) No. 8 Jalan Sultan Viet Nam Mexico
Maoming Road (S) Shanghai, 200020 Ismail, 50250, Kuala Lumpur Hitachi Asia Ltd. Hitachi Mexico, S.A. de C.V.
TEL : +86 (21) 6472-1002 TEL : +60 (3) 2031-8751 (Ho Chi Minh City Office) Andres Bello No.10 Piso 10
FAX : +86 (21) 6472-4990 FAX : +60 (3) 2031-8758 4th Floor, The Landmark, 5B Ton Duc Col. Chapultepec Polanco
(Guangzhou Office) Thang Street District 1, Ho Chi Minh City 11560, Mexico, D.F.
3406, Office Tower, CITIC Plaza 233 Philippines TEL : +84 (8) 829-9725 TEL : +52 (55) 5282-9040
TianHe North Road, Guangzhou 510613 Hitachi Asia Ltd. (Philippines Office) FAX : +84 (8) 829-9729 FAX : +52 (55) 5282-9042
TEL : +86 (20) 3891-2737 17th Floor Oledan Square (Ha Noi Office)
FAX : +86 (20) 8752-1301 6788 Ayala Avenue, Sun Red River Bldg., 5th Floor, North America
Makati City, Philippines 1226 23 Phan Chu Trinh Street U.S.A.
Hitachi East Asia Ltd.(Hong Kong Office) TEL : +63 (2) 886-9018 Hoan Kiem District, Hanoi Hitachi America, Ltd.
4th Floor, North Tower World Finance FAX : +63 (2) 887-3794 TEL : +84 (4) 933-3123 (Industrial Components & Equipment
Centre, Harbour City, Canton Road, Tsim FAX : +84 (4) 933-3125 Division)
Sha Tsui, Kowloon Hong Kong. 50 Prospect Avenue, Tarrytown,
TEL : +852 2735-9218 New York, 10591-4698
FAX : +852 2735-6793 TEL : +1(914) 332-5800
FAX : +1(914) 332-5555
Taiwan Hitachi Asia Pacific Co., Ltd (Charlotte Office)
3rd Floor, Hung Kuo Building No. 167 (Industrial Components & Equipment
Tun-Hwa North Road, Taipei (105) Division)
Taiwan 6901 Northpark Blvd., Charlotte, NC 28216
TEL : +886 (2) 2718-3666 TEL : +1(704) 494-3008
FAX : +886 (2) 2718-8180 FAX : +1(704) 494-3809

Products described in this catalog may differ from different countries or regions. Contact your nearest Hitachi representative office for details.
Product appearances and specifications in this catalog are subject to change with or without notice, as Hitachi continues to develop the latest technologies and products for its customers.

ISO 8573-1

■ ISO 8573-1:2010
  CLASS 0 TÜV Approval

Printed in Thailand(H) HC-E102V 0812


Energy-Saving, User-Friendly HITACHI High Standard Oil Free Rotary Screw
Compressor for Both Environment and Productivity
‘Further Energy-Saving and User-Friendly’ is the concept for HITACHI oil free screw
compressor, DSP series.
Variable speed model achieved further energy saving by constant pressure control,
and customer can choose from wide line up.
● Environmentally friendly, oil free rotary screw compressor
● Easy operation by large LCD monitoring display
● Advanced functions and performance by scheduled operation and efficient maintenance
● Contribution to cost saving and productivity

Ultimate Air Quality


True Oil-free Air at Class 0 Level
Test and analysis of condensation of oil in the discharge air of Hitachi Oil-free Screw Compressor (DSP) are ISO-8573-1
implemented by third party (TÜV) based on ISO8573-1 standard. By the test result, oil contained in the discharge air
of Hitachi DSP is proved and certified as the highest level of quality air “Class 0” .

■ ISO8573-1:2010 CLASS 0 TÜV Certification


TÜV (The Technische Überwachungs Verein), a Germany
based international test service provision third-party on
aspects of technical safety and quality evaluation, is
globally well-reputed on its neutrality and expertise as well
as its strictness in testing.

High Performance Air End Hi-precooler System Model List Single-stage, oil free screw
Hi-precooler system cools down high temperature discharge DSP Fixed Speed Series (kW)
compressor is HITACHI original.
air down to 180˚C and below before entering aftercooler. This Dryer 15 22 30 37 45 55 75 90 100 120 132 --
240 1
enables aftercooler to be less than the upper temperature limit. Cut Down Maintenance and Initial Cost

Single-stage
Air-
HITACHI applied this system to large size, air-cooled model cooled Built-in
and improved reliability. Water-
100 100
cooled

Air discharge is cooled Air-


50 50
Two-stage
cooled Built-in
160--180˚C
Stainless Steel Fine Rotor by hi-precooler.
Water-
cooled 0 0
Particular stainless steel, which is superior in corrosion Ventilation Fan Exhaust
Built-in Single-stage Two-stage Single-stage Two-stage
resistance and durability, is applied for rotor with highly DSP V-type with Variable Speed Drive (kW)
Comparison of Comparison of
Maintenance Cost (%) Initial Cost (%)
accurate grinding. Furthermore, to reduce internal leakage,
Dryer 15 22 30 37 45 55 75 90 100 120 132 --
240 1
(Annual average)
mirror finished surface enables to keep appropriate
Example of Hitachi 55kW without dryer model
Single-stage

clearance, including thermal expansion during operation. First Stage Hi-precooler Air-
Air End cooled Built-in
Comparison of cost with the same class
High Performance Rotor Profile Water-
cooled motor output
Intercooler
The rotor enlarges significantly due to thermal expansion. Aftercooler
Air- Because there is only one air end for DSP single-stage
Heat expansion of the rotor occurs since it exposes 300˚C
Two-stage

cooled Built-in model, the initial cost is lower than two-stage model.
discharge air to the single-stage model. (200˚C even for Second Stage 2 The maintenance cost is about half the price of two-stage
Air End
the two-stage model) HITACHI original 3D correction Water- for the same reason.
cooled Built-in
technology is used to keep the most appropriate clearance.
: V plus : NEXT Series
1 *1 132, 145, 160, 200 and 240kW 2
*2 160 and 240kW
OIL FREE SCREW TWO STAGE (45–120kW)

Thorough Reduction of Loss due to the New Air-End


Large Air Delivery and Energy-Saving by DSP Energy-Saving due to Variable Speed Drive (V-type)
Enlarged Energy-Saving Effect due to Original Capacity Control
Control Panel
For V-type model, variable speed drive and air capacity control are all originally designed by Hitachi. Control system which enables to control the discharge
pressure within ±0.01MPa, not only makes high response to the load possible, but also achieve great effect of Energy-Saving together with outstanding stability.
Cooler
Significant Energy-Saving due to Constant Pressure Control Energy-Saving Achieved by Variable Speed Drive
100
MPa Energy-Saving Conventional

Power Consumption Rate (%)


Conventional Model Load/Unload Type
0.70
80
About 83MWh Annual
Suction Filter
60
Energy-Saving

Pressure
Variable Speed Drive 0.60
14% Down
40 (60% Load Rate) Calculation condition:
(V-type ONLY) Necessary Pressure ±0.01MPa
V-type DSP 75kW V-type (0.7MPa SPEC),
20
Air-End (Constant Pressure Control) V-type 0.6MPa as necessary pressure,
0 8,000h/year operation, 60% load rate
Time 0 20 40 60 80 100
Air Consumption (%)
Starter Panel Power Reduction and Reliability Improvement Patented Hitachi Original Unloader-less Structure
Suction Filter
during Unload Operation due to Hitachi Original (JP 3817420) No Negative Pressure when Unloading

Gear Casing Unloader-less and Inter-Stage Purge Technology Higher Reliability of Shaft Seal

Significant power reduction and reliability improvement of shaft seal during 1st Stage Air-end
Shaft Seal Shaft Seal

Inter-Stage Purging
unload operation are secured due to Hitachi original technology of purging on Inter-cooler 2nd Stage Air-end
both inter-stage and 2nd stage.
Shaft Seal
And, because of unloader-less structure, maintenance of unloader (suction Power Reduction when Unloading
Shaft Seal

2nd Stage
throttle valve) is unnecessary. Purging After-cooler
*The above picture shows the internal structure of the new
DSP-75kW V-type, Water-Cooled model.
DCBL Drive System for 55/75kW (JP 3255213 others) Japan Regional Award
●Cascade Vector Control (in line form) as the DCBL motor control system achieve both significant Energy-Saving and
High Capacity Line-Up of Variety excellent reliability.
●Retry function when minor failure occurs is equipped as standard on DCBL controller. Retry is performed up to 3 times
Equipped with New Air-End High Discharge Pressure Available
according to the judgment by itself when the motor trips. So it is possible to eliminate the influence to the operation of the
High capacity is realized by newly Maximum pressure changes from 0.88MPa to 0.93MPa. A variation compressor from outside disturbance.
developed Air-End. of series composition due to high discharge pressure makes possible
of various system design of variety.
Cooling Fan (45/55/75kW Air Cooled Models) Standard Response to Ambient Temperature up to 45˚C
Conventional Newly developed turbo fan is Continuous operation under up to 45˚C and long maintenance cycle
Output Model DSP
Pursuit of Energy-Saving controlled by inverter. Responding to are possible by adoption of new internal structure which minimizes
55kW 8.7 9.4 the air delivery change, the rotation the internal temperature rise.
8%up ECOMODE speed of cooling fan is automatically Continuous Operation under Same as the conventional model
Responding to the load rate of compressor, unnecessary lowered to achieve Energy-Saving. Ambient Temperature of up to 45˚C (respond up to 40˚C) in maintenance cycle
75kW 12.8 13.2 compression is avoided by automatically lowering the unload At the same time, noise from cooling
●Ventilation Structure of Air Cooled Model
fan is lowered too.
3%up start-up pressure. Energy-Saving is achieved. Taking 75kW  Compulsory ventilation structure inside the unit due to the wind from
water-cooled, 0.7MPa SPEC, Fixed Speed model as an example, in cooler is adopted.
18.3
After-cooler
100kW 16.8 case of 70% load rate 11.3MWh is saved annually, and in case of
Exhaust Air

2
8%up (m3/min) 90% load rate 28MWh is saved annually. About 50%
Inter-cooler

Power Used on Fan (kW)


* Water-Cooled, 0.7MPa, Fixed Speed Model (Calculation condition: air receiver tank of 2.26m3 is installed, 8,000h/year operation) 1.5 Energy- Cooling Fan
About 50%
Saving
Energy-
Pressure 1 Saving 1.8
Low Noise Conventional Capacity Control ECOMODE Capacity Control 0.5
1.2
kW
kW
0.9 Suction Air from
0.6 kW
Unnecessary kW
Right Side
Unload Start-up Pressure
Low Noise Design of Conventional Operation compression 0 Air-End
is avoided. 100% Load 80% Load 100% Load 80% Load Main Motor
Low noise achieved by the low-noise rotor profile, adoption of vibration- DSP (55kW) DSP (75kW)
Unload Start-up Pressure
proof driving system and low-noise structure of suction and exhaust. of ECOMODE Operation
Suction from Rear Side
Air-Cooled, 0.7MPa, Fixed Speed Model Load Cut-in Pressure
Time
55kW 75kW 100kW
dB(A)
76 Power
Environment Response
74 7dB Oil Mist Remover (OMR) and Auto Drain
6dB Down
Power Consumption of Conventional Operation Power Consumption of ECOMODE Operation
Auto Drain Valves for
Oil Mist Remover (OMR)
70
Down Valve installed as Standard Equipment Inter-cooler/After-cooler
76 Energy-Saving Effect (without Built-in Dryer
6dB 74 Oil Mist Remover (OMR), which recaptures the oil mist Model ONLY)
66
69 Down 69 from gear case and recycle, is standard equipment.
68
62 63 Also, auto drain valves for inter-cooler and after-cooler
Conventional DSP Conventional DSP Conventional DSP are standard equipments to drain intermittently without
Model Model Model Time
air loss.
3 4
OIL FREE SCREW TWO STAGE (45–120kW)

■Fixed Speed Series (45/55/75 kW)


Air Dryer (Built-in Dryer Type) Improvement in Reliability and Maintenance DSP-45AT[R]5N DSP-55AT[R]5N DSP-75AT[R]5N DSP-45WT[R]5N DSP-55WT[R]5N DSP-75WT[R]5N
Model
Item・Unit DSP-45AT[R]6N DSP-55AT[R]6N DSP-75AT[R]6N DSP-45WT[R]6N DSP-55WT[R]6N DSP-75WT[R]6N
Low Pressure Drop Stainless Heat Exchanger Adoption of Totally Enclosed Flange Motor Cooling Method –– Air-cooled Water-cooled
Low pressure drop, stainless heat exchanger Reliability is improved due to the adoption of totally enclosed flange Discharge Pressure MPa 0.70 0.93 0.70 0.93 0.70 0.93 0.70 0.93 0.70 0.93 0.70 0.93
Capacity (50/60Hz) m3/min 7.4 / 7.8 6.2 / 6.5 9.2 7.2 / 7.7 13.0 10.5 / 11.1 7.5 / 7.9 6.4 / 6.7 9.4 7.4 / 7.9 13.2 10.7 / 11.3
is newly developed. Loss due to pressure motor. Maintenance also becomes easier due to the removal of
Nominal Output kW 45 55 75 45 55 75
drop is minimized together with improvement coupling.
Motor Type –– 2-Pole TEFC Flange Motor 2-Pole TEFC Flange Motor
in durability. Intake Air Press. / Temp. –– Atmospheric Pressure / 0 − 45˚C [ 5 − 45˚C ] Atmospheric Pressure / 0 − 45˚C [ 5 − 45˚C ]
Improvement in Maintenance Discharge Temperature ˚C Ambient Temperature + 15 or below Cooling Water Temperature + 13 or below
Improvement of Reliability Maintenance-friendly layout is adopted, which makes filter change
Discharge Pipe Diameter B 2 (Flange) 2 (Flange)
Amount of Cooling Water L/min 90 120
Compared to the conventional model, the and cleaning of cooler much easier. Cooling Water Temperature ˚C –– 35 or below
performance when operated in high tempera- Cooling Water Pipe Diameter B 1・1/4
ture environment is significantly improved. Starting Type –– Star-Delta (3 contact) Star-Delta (3 contact)
Driving Method –– Direct Connection with Motor + Gear Driving Direct Connection with Motor + Gear Driving
Lubricating Oil Capacity L 25 (Not filled) 15 (Not filled)

Versatility of Control Design Cooling Fan Motor Output kW 1.5 2.2 0.05 × 2
P.D.P ˚C [ 10 (Under Pressure) ] [ 10 (Under Pressure) ]
[Air Dryer] Refrigerator Nominal Output kW [ 2.2 ] [ 3.0 ] [ 2.2 ] [ 3.0 ]
Large LCD Display Monitor with Easy Command Interface
Refrigerant –– [ R407C ] [ R407C ]
Large LCD display monitor is equipped as standard. Various functions can be easily set by control panel. In case of trouble, the information Weight kg 1,500 [1,650] 1,790 [1,960] 1,480 [1,630] 1,640 [1,810]

of status of compressor is displayed so that it is possible to quickly carry out the Troubleshooting. Dimensions (W ×D ×H) mm 2,000×1,300×1,800 2,250×1,300×1,800 2,000×1,300×1,800
Sound Level (1.5m from front side) dB(A) 63 65 63 65 68 63 63 65 66

Standard Function
■Fixed Speed Series (90/100/120 kW)
LCD Display Monitor Monitor Switch Menu Switch Digital Monitor
・3 Languages Available (English, Japanese, Chinese) Model DSP-90A5L(M)N DSP-100A5L(M)N DSP-120A5MN DSP-90W5L(M)N DSP-100W5L(M)N DSP-120W5MN
・ECOMODE Item・Unit DSP-90A6L(M)N DSP-100A6L(M)N DSP-120A6MN DSP-90W6L(M)N DSP-100W6L(M)N DSP-120W6MN

・Maintenance Time Notification Cooling Method –– Air-cooled Water-cooled


Discharge Pressure MPa 0.70 0.93 0.70 0.93 0.70 0.93 0.70 0.93 0.70 0.93 0.70 0.93
・Alarm and Trouble History Display
Capacity m3/min 16.6 13.9 18.0 15.4 20.5 17.3 16.8 14.0 18.3 15.6 21.0 17.6
・Schedule Operation Nominal Output kW 90 100 120 90 100 120
・Operation Data Memory Motor Type –– 2-Pole TEFC Flange Motor 2-Pole TEFC Flange Motor
・Instantaneous Power Interruption (IPI) Restart etc.  Intake Air Press. / Temp. –– Atmospheric Pressure / 0 − 45˚C Atmospheric Pressure / 0 − 45˚C
Discharge Temperature ˚C Ambient Temperature + 15 or below Cooling Water Temperature + 13 or below
Option Discharge Pipe Diameter B 2 (Flange) 2 (Flange)
Amount of Cooling Water L/min 160 180
・Dual Operation
Cooling Water Temperature ˚C –– 35 or below
・Multi-Unit Control Operation Cooling Water Pipe Diameter B 1・1/2
Start Switch Stop Switch ・AUTO Operation Starting Type –– Star-Delta (3 contact) Star-Delta (3 contact)
・Communication Function Driving Method –– Direct Connection with Motor + Gear Driving Direct Connection with Motor + Gear Driving
Lubricating Oil Capacity L 26 (Not filled) 16 (Not filled)
Cooling Fan Motor Output kW 1.1 × 2 1.5 × 2 L : 0.2 × 2, M : 0.05 × 3 0.05 × 3
Weight kg 2,250 2,400 2,100 2,250
Dimensions (W ×D×H) mm 2,150×1,520×1,975 2,150×1,520×1,825
Specifications Sound Level (1.5m from front side) dB(A) 68 70 69 71 72 73 66 68 67 69 69 70
■Variable Speed Drive NOTE:
Model DSP-100VA5MN DSP-100VW5MN 1. Capacity is converted value at its inlet condition (atmospheric pressure). 6. DSP compressors are not designed, intended or approved for breathing
DSP-55VAT[R]N DSP-75VAT[R]N DSP-55VWT[R]N DSP-75VWT[R]N 2. Sound Level is value at 1.5m in front and 1m height in an anechoic room. It may air applications.
Item・Unit DSP-100VA6MN DSP-100VW6MN
vary in different operating conditions and/or different environment with echo of 7. Pressures are indicated as the gauge pressure.
Cooling Method –– Air-cooled Water-cooled actual field installations. 8. DSP can not run in excess of 45˚C of ambient temperature. Ventilation
Discharge Pressure MPa 0.70 0.93 0.70 0.93 0.70 0.93 0.70 0.93 0.70 0.93 0.70 0.93 Sound level might be increased by 2dB at PQ WIDEMODE ON. and/or air conditions should be considered to maintain the compressor room
Capacity m3/min 9.3 7.7 12.6 10.9 18.0 15.4 9.5 8.0 12.9 11.4 18.3 15.6 3. P.D.P is measured at 30 degree C of intake air temperature and rated discharge temperature.
pressure. 9. For the quality of the cooling water, contact your nearest dealer or Hitachi local
Capacity @ PQ WIDEMODE ON at 0.6MPa m3/min 9.6 9.3 13.0 12.6 –– 9.8 9.5 13.4 13.0 ––
P.D.P might be much worse at 0.4MPa or less of discharge pressure. representative offices.
Nominal Output kW 55 75 100 55 75 100 P.D.P might be 13 degree C at PQ WIDEMODE ON and 0.6MPa of discharge 10. Install the DSP indoors and avoid flammable and corrosive environment, moisture
Motor Type –– DCBL Motor 2-Pole TEFC Flange Motor DCBL Motor 2-Pole TEFC Flange Motor pressure. and dust.
Intake Air Press. / Temp. –– Atmospheric Pressure / 0 − 45˚C [ 5 − 45˚C ] Atmospheric Pressure / 0 − 45˚C [ 5 − 45˚C ] 4. Capacity of Built-in Dryer model may decrease by up to 3% when drain 11. Select 3.5-4.5 ton duty fork truck for transportation of DSP-90/100/120 .
condensates. 12. Hitachi may make improvements and/or changes in the appearance and/or
Discharge Temperature ˚C Ambient Temperature + 15 or below Cooling Water Temperature + 13 or below
5. Earth leakage circuit breaker is out of scope of supply from Hitachi. specifications described in this publication at anytime without notice.
Discharge Pipe Diameter B 2 (Flange) 2 (Flange)
Amount of Cooling Water L/min 90 120 160
Cooling Water Temperature ˚C –– 35 or below
Cooling Water Pipe Diameter B 1・1/4 1・1/2 ■Model Nomenclature
Starting Type –– Soft Start Inverter Soft Start Inverter (45/55/75 kW) (90/100/120 kW)
Driving Method –– Direct Connection with Motor + Gear Driving Direct Connection with Motor + Gear Driving
Lubricating Oil Capacity L 25 (Not filled) 26 (Not filled) 15 (Not filled) 16 (Not filled)
Cooling Fan Motor Output kW 1.5 2.2 1.5 × 2 0.05 × 2 0.2 × 2 D S P - 75 V A T R 5 N D S P - 100 V A 5 M N
P.D.P Oil Free DSP Oil Free DSP
˚C [ 10 (Under Pressure) ] [ 10 (Under Pressure) ]
Screw Frequency (5:50Hz, 6:60Hz,ONLY for Fixed Speed) Screw Voltage (L:200V class, M:400V class)
[Air Dryer] Refrigerator Nominal Output kW [ 2.2 ] [ 3.0 ] –– [ 2.2 ] [ 3.0 ] ––
Package R:Built-in Dryer (No R indication for without dryer type) Package Frequency (5:50Hz, 6:60Hz)
Refrigerant –– [ R407C ] [ R407C ] Nominal Two-stage Nominal A:Air-cooled, W:Water-cooled
Output (kW) Output (kW)
Weight kg 1,340 [1,490] 1,560 [1,730] 2,350 1,320 [1,470] 1,410 [1,580] 2,200 A:Air-cooled, W:Water-cooled V:VSD (No V indication for Fixed Speed)
V:VSD (No V indication for Fixed Speed)
Dimensions (W×D ×H) mm 2,000×1,300×1,800 2,250×1,300 ×1,800 2,150 ×1,520 ×1,975 2,000 ×1,300 ×1,800 2,150×1,520×1,825
Sound Level (1.5m from front side) dB(A) 63 65 67 68 69 71 63 65 66 67 69

5 6
OIL FREE SCREW TWO STAGE (132–240kW)

Debut of DSP V-type in Large Class (160/240kW) water-cooled Advanced Technology, Top Class of Energy-Saving Achieved
Enlarged Line-up of DSP in 132−240kW Range Large Class of Air-cooled DSP 132−240kW

Aftercooler
Air Intake Filter Air Intake Filter
Starter Panel
Dual layout filter Air End(1st Stage)
element (Suction Throttle Valve)
provides higher
reliability.
Oil Mist Remover
(OMR) Front
Auto drain solenoid valves for conden- Intercooler Oil Mist Remover
sate of both intercooler and aftercooler as Standard
Gear Case Air End
minimize air consumption. (2nd Stage) Drive System Cooler Collects oil mist from the
Cooler
(Suction Throttle Valve) gear case and recycles.
AC/IC Auto
Drain Compact Design
Solenoid Valve TEFC Motor Air/Oil coolers are installed
in both sides of drive system.
Strainer
Oil Cooler Aftercooler

Dual-V installation of Intercooler


Coolers
Quick and Easy access through
Low Sound Airflow Path
rear panel for inspection and Newly developed silencer
cleaning. structure airflow path.

Discharge Port

TEFC Motor
Energy-Saving (V-type) High Capacity by Equipping New Rear Highly reliable, highly efficient 4-pole TEFC motor.

Further Energy-Saving is achieved by DSP with Built-in Air-End


Inverter.
High Reliability and Easy Maintenance
100
Totally enclosed flange motor is standard
Power Consumption Rate (%)

HITACHI Fixed Speed Type DSP


Low Noise and Vibration New totally enclosed flange motor is applied to improve reliability. Motor shaft
75 Control Pressure:0.65 / 0.75MPa
(Load / Unload) in direct connection without coupling enables easy maintenance work.

High precooler system (air cooled models) Ventilating fan Air exhaust High precooler cool down the
50
About 11% Reduction in Compact Design by Optimized Layout High precooler system reduces temperature of extremely hot air to aftercooler
internal temperature between
160˚C—180˚C
Power Consumption
Power Reduction of about 220MWh of Components and two stage cooling structure improves reliability.
25 DSP V Type High precooler
(240kW Model, 8,000h/year 1st stage
Control Pressure:0.65MPa
Operation Time, 60% Load) High Discharge Pressure Available air end Two stage
cooling
structure
0 1.0MPa is available with high reliability. Intercooler
Aftercooler
0 20 40 60 80 100 High Discharge Pressure Available
Air Consumption Rate (%)
Maintenance Friendly
*Compared to conventional Load/Unload Control Type, lower pressure setting is possible due to the (up to 1.0MPa) 2nd stage
air end
stable pressure control. DSP series provides easy accessibility for inspection and maintenance.

Specifications Specifications
Model DSP-132W5N DSP-145W5N DSP-160W5N DSP-200W5N DSP-240W5N DSP-160VW5N DSP-240VW5N Model DSP-132A5 DSP-145A5 DSP-160A5 DSP-200A5 DSP-240A5
Item・Unit DSP-132W6N DSP-145W6N DSP-160W6N DSP-200W6N DSP-240W6N DSP-160VW6N DSP-240VW6N Item・Unit DSP-132A6 DSP-145A6 DSP-160A6 DSP-200A6 DSP-240A6
Cooling Method –– Water-cooled Cooling Method –– Air-cooled
Control Method –– Fixed Speed Type V type (VSD) Discharge Pressure MPa 0.75 1.0 0.75 1.0 0.75 1.0 0.75 1.0 0.75 1.0
Discharge Pressure MPa 0.75 0.93 0.75 0.93 0.75 0.93 0.75 0.93 0.75 0.93 0.75 0.93 0.75 0.93 Capacity m3/min 22.5 19.0 25.0 20.0 27.5 22.5 35.5 30.0 40.0 32.5
Capacity m3/min 23.4 20.7 26.0 22.2 28.5 24.8 37.0 32.2 40.5 35.0 28.5 24.8 40.5 35.0 Nominal Output kW 132 145 160 200 240
Nominal Output kW 132 145 160 200 240 160 240 Motor Type –– 4-Pole TEFC Flange Motor
Motor Type –– 4-Pole TEFC Flange Motor Intake Air Press. / Temp. –– Atmospheric Pressure / 0 − 40˚C
Intake Air Press. / Temp. –– Atmospheric Pressure / 0 − 40˚C Discharge Temperature ˚C Ambient Temperature + 15 or below
Discharge Temperature ˚C Cooling Water Temperature + 13 or below Discharge Pipe Diameter B 2 1/2 (Flange) 3 (Flange)
Discharge Pipe Diameter B 2 1/2 (Flange) 3 (Flange) 2 1/2 (Flange) 3 (Flange) Starting Type –– Star-Delta
Starting Type –– Star-Delta Inverter Driving Method –– Direct Connection with Motor + Gear Driving
Driving Method –– Direct Connection with Motor + Gear Driving Lubricating Oil Capacity L 50 (Not filled) 60 (Not filled)
Lubricating Oil Capacity L 40 (Not filled) 50 (Not filled) 40 (Not filled) 50 (Not filled) Cooling Fan Motor Output kW 4.4 (1.1 × 4) 6.0 (1.5 × 4)
Cooling Fan Motor Output kW 0.4 Weight kg 3,900 4,000 5,200
Weight kg 3,800 4,800 4,000 5,100 Dimensions (W ×D ×H) mm 2,900×1,710×1,925 3,200×1,890×1,950
Dimensions (W×D×H) mm 2,500×1,600×1,925 2,800×1,800×1,950 2,500×1,600×1,925 2,800×1,800×1,950 Sound Level (1.5m from front side) dB(A) 73 74 74 75 74 75 76 77 77 78
Sound Level (1.5m from front side) dB(A) 68 69 69 70 69 70 69 70 70 71 70 70 71 71 NOTE:
1. Capacity is converted value at its inlet condition (atmospheric pressure). 6. DSP series can not run in excess of 40˚C of ambient temperature. Ventilation and/or air conditions should
NOTE: 2. Sound Level is value at 1.5m in front and 1m height in an anechoic room. It may vary in different operating be considered to maintain the compressor room temperature.
1. Capacity is converted value at its inlet condition (atmospheric pressure). 6. DSP can not run in excess of 40˚C of ambient temperature. Ventilation and/or air conditions conditions and/or different environment with echo of actual field installations. 7. Install the DSP indoors and avoid flammable and corrosive environment, moisture and dust.
2. Sound Level is value at 1.5m in front and 1m height in an anechoic room. It may vary in different operating should be considered to maintain the compressor room temperature. 3. Earth leakage circuit breaker is out of scope of supply from Hitachi. 8. Hitachi may make improvements and/or changes in the appearance and/or specifications described in this
conditions and/or different environment with echo of actual field installations. 7. For the quality of the cooling water, contact your nearest dealer or Hitachi local representative offices. 4. DSP series compressors are not designed, intended or approved for breathing air applications. publication at anytime without notice.
3. Earth leakage circuit breaker is out of scope of supply from Hitachi. 8. Install the DSP indoors and avoid flammable and corrosive environment, moisture and dust. 5. Pressures are indicated as the gauge pressure.
4. DSP compressors are not designed, intended or approved for breathing air applications. 9. Hitachi may make improvements and/or changes in the appearance and/or specifications described in this

7 5. Pressures are indicated as the gauge pressure. publication at anytime without notice.
8
OIL FREE SCREW SINGLE STAGE / TWO STAGE (15–55kW)

High Performance NEW DSP Series


Large Air Delivery
Newly-developed high efficiency air end is applied, and discharge air capacity is increased dramatically.

22kW Single-stage Model (0.69MPa) 37kW Single-stage Model (0.69MPa)

PQ WIDEMODE (22kW, 37kW, 55kW, Air-Cooled, Single-Stage Models)


Hitachi inverter controlling system brings about larger capacity under lower
pressure or smaller capacity under higher pressure. The available pressure range
is between 0.39 and 0.69MPa and air capacity has increased maximum 19−28%
compared with conventional models.
Conventional Model New Model Conventional Model New Model
Capacity in the PQ WIDEMODE Unit: m3/min
Unit: m3/min Unit: m3/min

High Reliability and Easy Maintenance


Totally-enclosed, fan-cooled
(TEFC) motor is equipped as
standard feature. PQ WIDMODE is set up as ON or OFF, depends on needs

Longer Overhaul Interval


Overhaul interval is extended
from 4 years to 6 years.

Further Discharge Air Capacity and Shorten Pressurization Time (PQ WIDEMODE)
Hitachi Original Pressure Setting Energy-Saving Effect, Comparing with
Pressurization time is shortened by maximum air capacity operation.
Two-Stage Model (22kW Single-Stage Model) For example, when 55kW model rises pressure in air receiver from the
2 sets of pressure setting, A and B, are available for capacity
control. By setting the operation time, it executes capacity control The maintenance cost for single-stage model low. ambient pressure to 0.69MPa, it can shorten maximum of 20 % more
by either A or B. In addition, A and B can be switched externally. PQ WIDEMODE offers competitive discharge air capacity with than conventional model.
two-stage model.

80%
100%

9 10
OIL FREE SCREW SINGLE STAGE / TWO STAGE (15−55kW)

Specifications New DSP Fixed Speed Series Specifications New DSP V-type with Variable Speed Drive

Single-Stage Single-Stage
■Air-cooled Model Without Dryer Model Dryer Built-in Model Without Dryer Model
Model Without Dryer Model Dryer Built-in Model DSP-22VA5Ⅰ DSP-37VA5Ⅱ DSP-55VA5Ⅰ DSP-22VAR5Ⅰ DSP-37VAR5Ⅱ DSP-55VAR5Ⅰ
DSP-37VW DSP-55VW
DSP-15A5Ⅱ DSP-22A5Ⅱ DSP-37A5Ⅲ DSP-55A5Ⅱ DSP-15AR5Ⅱ DSP-22AR5Ⅱ DSP-37AR5Ⅲ DSP-55AR5Ⅱ Item・Unit DSP-22VA6Ⅰ DSP-37VA6Ⅱ DSP-55VA6Ⅰ DSP-22VAR6Ⅰ DSP-37VAR6Ⅱ DSP-55VAR6Ⅰ
Item・Unit DSP-15A6Ⅱ DSP-22A6Ⅱ DSP-37A6Ⅲ DSP-55A6Ⅱ DSP-15AR6Ⅱ DSP-22AR6Ⅱ DSP-37AR6Ⅲ DSP-55AR6Ⅱ Cooling Method –– Air-Cooled Water-Cooled
Discharge Pressure MPa 0.69 0.39 0.69 0.39 0.69 0.39 0.69 0.39 0.69 Discharge Pressure MPa 0.69 0.69
Rated
Discharge Air Delivery m3/min 2.0 2.5 3.4 4.0 5.0 5.9 6.4 8.0 2.0 3.4 5.0 6.4 Discharge Air Delivery m3/min 3.4 5.0 6.4 3.4 5.0 6.4 4.2 6.4
Motor Nominal Output kW 15 22 37 55 15 22 37 55 In PQ Discharge Pressure MPa 0.39 0.49
Suction Pressure / Temperature ˚C Atmospheric Pressure / 0 − 40 Atmospheric Pressure / 5 − 40 WIDEMODE Discharge Air Delivery m3/min 4.3 6.4 8.2 4.0 6.0 7.6 ––
Discharge Temperature ˚C Atmospheric Temperature + 15 or below Operating Range of PQ WIDEMODE MPa 0.39−0.69 0.49−0.69
Discharge Pipe Diameter –– R1 R1 1/2 R1 R1 1/2 Motor Nominal Output kW 22 37 55 22 37 55 37 55
Starter Method –– Full Voltage Start Star-Delta (3 contact) Full Voltage Start Star-Delta (3 contact) Motor Type –– 4-pole TEFC Motor 4-pole TEFC Motor
Driving Method –– V-Belt + Gear-Driven Suction Pressure / Temperature ˚C Atmospheric Pressure / 0 − 40 Atmospheric Pressure / 5 − 40 Atmospheric Pressure / 0 − 40
Cooling Fan Motor Nominal Output kW 0.75 0.9 0.75 0.9 Discharge Temperature ˚C Ambient Temperature + 15 or below Cooling Water Temperature + 13 or below
Coolant Pump Motor Nominal Output kW(50/60Hz) 0.2 / 0.3 Discharge Pipe Diameter –– R1 R 1 1/2 R1 R 1 1/2 R 1 1/2
Lubricating Oil Amount L 12 (Not filled in) 18 (Not filled in) 12 (Not filled in) 18 (Not filled in) Starter Method –– Inverter Inverter
P.D.P. ˚C 10 (Under Pressure) Driving Method –– Inverter Control + Purge Control Inverter Control + Purge Control
Refrigerator Nominal Output kW 0.5 1.1 Cooling Fan Motor Nominal Output kW 0.75 0.9 0.75 0.9 0.2
Air Dryer ––
Refrigerant –– R407C Lubricating Oil Filling Amount L 12 (Not filled) 18 (Not filled) 12 (Not filled) 18 (Not filled) 14 (Not filled)
Fan Motor Output W 25 25 × 2 120 Coolant Pump Motor Nominal Output kW(50/60Hz) 0.2 / 0.3 ––
Weight kg 750 800 1,020 1,240 780 830 1,170 1,390 Amount of Cooling Water L/min 60 80
Dimensions (W×D ×H) mm 1,400×970×1,400 1,780 ×980×1,500 1,400 ×970×1,400 2,180 ×980×1,500 Cooling Water Temperature ˚C –– 32 or below
Sound Level (1.5m from front side) dB(A) 62 63 63 64 66 68 68 70 62 63 66 68 Cooling Water Pipe Diameter –– R1
P.D.P. ˚C 10 (Under Pressure)
■Water-cooled Refrigerator Nominal Output kW 1.1
Without Dryer Model Air Dryer –– ––
Model Refrigerant –– R407C
DSP-15W5Ⅰ DSP-22W5Ⅰ DSP-37W5Ⅲ DSP-45W5Ⅲ DSP-55W5Ⅲ Fan Motor Output 25 120
W
Item・Unit DSP-15W6Ⅰ DSP-22W6Ⅰ DSP-37W6Ⅲ DSP-45W6Ⅲ DSP-55W6Ⅲ Weight 850 1,080 1,180 880
kg 1,230 1,330 1,050 1,150
Discharge Pressure MPa 0.69 0.39 0.69 0.39 0.69 0.39 0.69 0.39 0.69 0.39 Dimensions (W ×D ×H) mm 1,650×970×1,400 1,780×980×1,500 1,650×970×1,400 2,180×980×1,500 1,780×980×1,500
Discharge Air Delivery m3/min 2.0 2.5 3.4 4.0 4.2 5.9 5.0 6.8 6.4 8.0 Sound Level (1.5m from front side) dB(A) 63 66 68 63 66 68 64
Motor Nominal Output kW 15 22 37 45 55
Suction Pressure / Temperature ˚C Atmospheric Pressure / 0 − 40
Discharge Temperature ˚C Cooling Water Temperature + 13 or below
Discharge Pipe Diameter –– R1 R1 1/2 Two-Stage
Amount of Cooling Water L/min 50 50 60 80 80
Cooling Water Temperature ˚C 32 or below Model Without Dryer Model Dryer Built-in Model
Cooling Water Pipe Temperature –– R3/4 R1 DSP-37VAT5 DSP-37VATR5
Starter Method –– Full Voltage Start Star-Delta (3 contact) Item・Unit DSP-37VAT6 DSP-37VATR6
Driving Method –– V-Belt + Gear-Driven Cooling Method –– Air-Cooled
Cooling Fan Motor Nominal Output kW 0.1 Discharge Pressure MPa 0.69 0.88 0.69 0.88
Lubricating Oil Amount L 10 (Not filled in) 14 (Not filled in) Discharge Air Delivery m3/min 5.3 4.6 5.3 4.6
Weight kg 690 760 970 1,190 1,190 Motor Nominal Output kW 37
Dimensions (W×D ×H) mm 1,400×970×1,400 1,520×980×1,500 Motor Type –– 4-pole TEFC Motor
Sound Level (1.5m from front side) dB(A) 62 63 63 64 64 66 64 66 64 66 Suction Pressure / Temperature ˚C Atmospheric Pressure / 0 − 40 Atmospheric Pressure / 5 − 40
Discharge Temperature ˚C Ambient Temperature + 15 or below
Discharge Pipe Diameter –– R 1 1/2
Starter Method
Two-Stage Driving Method
––
––
Inverter
Inverter Control + Purge Control
Cooling Fan Motor Nominal Output
■Air-cooled
kW 0.75
Lubricating Oil Filling Amount L 18 (Not filled)
Model Without Dryer Model Dryer Built-in Model
P.D.P. ˚C 10 (Under Pressure)
DSP-22AT5Ⅰ DSP-30AT5Ⅰ DSP-37AT5Ⅰ DSP-22ATR5Ⅰ DSP-30ATR5Ⅰ DSP-37ATR5Ⅰ
Refrigerator Nominal Output kW 1.1
Item・Unit DSP-22AT6Ⅰ DSP-30AT6Ⅰ DSP-37AT6Ⅰ DSP-22ATR6Ⅰ DSP-30ATR6Ⅰ DSP-37ATR6Ⅰ Air Dryer ––
Refrigerant –– R407C
Discharge Pressure MPa 0.69 0.88 0.69 0.88 0.69 0.88 0.69 0.88 0.69 0.88 0.69 0.88
Fan Motor Output W 25 × 2
Discharge Air Delivery m3/min 3.6 3.1 4.6 3.9 5.3 4.6 3.6 3.1 4.6 3.9 5.3 4.6
Weight kg 1,200 1,350
Motor Nominal Output kW 22 30 37 22 30 37
Dimensions (W ×D ×H) mm 1,780×980×1,500 2,180×980×1,500
Suction Pressure / Temperature ˚C Atmospheric Pressure / 0 − 40 Atmospheric Pressure / 5 − 40
Sound Level (1.5m from front side) dB(A) 67 67
Discharge Temperature ˚C Ambient Temperature + 15 or below
Discharge Pipe Diameter –– R 1 1/2 NOTE:
1. Capacity shows the flow rate converted in suction condition at rated discharge 5. Earth leakage circuit breaker is out of scope of supply from Hitachi.
Starter Method –– Star-Delta (3 contact)
pressure. 6. DSP series compressors are not designed, intended or approved for breathing air
Driving Method –– V-Belt + Gear-Driven 2. Noise Level is the value under the condition of full load running and auto-drain applications.
Cooling Fan Motor Nominal Output kW 0.75 valves closed in an anechoic room. 7. Pressures are indicated as the gauge pressure.
Lubricating Oil Capacity L 18 (Not filled) It may vary in different operating conditions and/or different environments with 8. New DSP series cannot run in excess of 40˚C of ambient temperature. Ventilation
echo of actual field installations. and/or air conditions should be considered to maintain the compressor room
P.D.P. ˚C 10 (Under Pressure)
Noise level might be increased by 3dB when PQ WIDEMODE is ON. temperature.
Refrigerator Nominal Output kW 1.1 3. P.D.P. is measured at 30 degree C of intake air temperature and rated discharge 9. For the quality of the cooling water, contact your nearest dealer or Hitachi local
Air Dryer ––
Refrigerant –– R407C pressure. representative offices.
Fan Motor Output P.D.P. might be worse at 0.4MPa or less of discharge pressure. 10. Install the DSP indoors and avoid flammable and corrosive environment, moisture
W 25 × 2
P.D.P. might be 13 degree C at PQ WIDEMODE ON and 0.6MPa of discharge and dust.
Weight kg 1,050 1,150 1,200 1,300 pressure. 11. Motor output is nominal output.
Dimensions (W×D ×H) mm 1,780×980×1,500 2,180×980×1,500 4. Free Air Delivery of Built-in Dryer model may decrease by up to 3% when drain 12. Hitachi may make improvements and/or changes in the appearance and/or
Sound Level (1.5m from front side) dB(A) 64 66 67 64 66 67 condensates. specifications described in this publication at anytime without notice.

11 12
OIL FREE SCREW Options

Optional Specifications
HITACHI FOOD GRADE DSP OIL (Option)
HITACHI FOOD GRADE DSP OIL – HITACHI Genuine Lubricant for Machine Used in Food Industry
Full Compliance with the International Hygiene Control Method for Food Safety “HACCP”*1
COSMOSⅡ (COmpressor Status MOnitoring System) To cope with the increasing demand for “Food Safety” , HITACHI newly developed HITACHI FOOD GRADE DSP OIL, HITACHI
genuine lubricant for HITACHI Oil-free Screw Compressor DSP used in food industry, fully complied with “HACCP”*1

Features
● The FOOD GRADE DSP OIL complies with the international hygiene control method for food safety “HACCP”*1
● The FOOD GRADE DSP OIL consists of only prescript substances by the U.S. FDA*2
● The FOOD GRADE DSP OIL is approved and registered as H1 grade*4 by the U.S. NSF International*3.
● The FOOD GRADE DSP OIL has doubled long life compared with the conventional mineral oils*5.
*1 Hazard Analysis Critical Control Point
*2 Food and Drug Administration
*3 National Sanitation Foundation International
*4 The oil which can be used in places where the oil can make occasional contact with foods.
The materials must be prescript substances regulated in the U.S. Food and Drug Law: FDA21 CFR178.3570.
*5 Compared with the conventional mineral oil, longer life by adoption of chemosynthetic based lubricant.
(Exchange cycle: 8,000 operating hours or 1 year which comes earlier.)

Specifications
Item Unit Content
ISO Viscosity Grade - 46
Color Phase - Colorless and Transparent
Density @15˚C kg/L 0.84

Viscosity @40˚C mm2/s 47
Flash Point ˚C 200
* Pour Point ˚C -50
Content L 20

Exchange Cycle - 8,000 operating hours or 1 year which comes earlier
Flushing running operation with the exclusive flushing use oil (new oil 20L can)
* Retrofit -
for 30 minutes × twice then refill with new oil
Package - Plastic Container Tank
* Weight kg About 18
Note:
1. Compliance Standard/Law: NSF H1 approval No. 138329 and FDA21 CFR178.3570
2. For retrofitting from conventional mineral oil to HITACHI FOOD GRADE DSP OIL, contact your nearest HITACHI authorized distributor/dealer.

Proposal for Energy-Saving

Dual Operation Various Energy-Saving operations are possible based on different combinations of V-type model (VSD) and Fixed
Speed type model.

Easy Energy-Saving operation by More Energy-Saving is demanded Further Energy-Saving effect and
2 or 3 units based on multi-unit control leveling operation hours are demanded

Multi-Unit Control with Multi-Unit Control with


V-M Combination System
Single-V type unit Multi-V type units
New Energy-Saving operation achieved by the Easy Energy-Saving is possible by Energy-Saving and leveling operation hours
combination of V-type and Fixed Speed type model multi-unit control with Single V-type unit are achieved by all V-type units.

Basic Example of V-M Combination System Following Energy-Saving effect can be


(75kW × 2 units) achieved due to the V-M Combination
DSP-75ATN×2
Fixed Speed type 75kW with Energy-Saving of 100MWh can be achieved in case of air consumption at 150%.

Power Consumption Rate (%)


AUTO operation function Comparison of annual power consumption
in case of air consumption at 150%
100MWh

Annual Power Consumption (MWh/y)


1,300
Other Options 1,200
Energy-Saving
Effect
1,100
DSP-75VATN+75ATN Calculation Condition:
1,000 1,200 ・8,000h/year operation
1,100 Control pressure
75ATN×2: 0.7MPa
75VATN+75ATN:0.6MPa
Air Receiver Tank 0
V-type 75kW Air Consumption Rate (%) DSP-75ATN DSP-75VATN
×2 +DSP-75ATN

13 14
OIL FREE SCREW Options, Precautions

Auxiliary Equipment to Enhance Air Quality


Oil Free Screw Compressed Air System

Compressed Air

Caution:
Failure to install an adequately sized receiver tank may cause
the DSP compressor to frequently load/unload. This may shorten
the mechanical life of the compressor.

Hitachi Air Dryer

HDR-15AX HDR-22AX HDR-37AX HDR-55AX HDR-75AX HDR-100AX


15 22 37 55 75 100
50/60Hz 2.5/2.9 4.0/4.3 6.8/7.4 10.8/11.3 15.0/15.7 19.0/20.0
0.97
80
5−40
10 Under Pressure
0.5 1.1 2.2 3.0 3.75
Air Cooled
Capillary Tube
Hot Gas Bypass Valve
R407C
Ivory (Munsell No. 5Y8.5/1)
Rc 1 Rc 1 1/2 Rc 2 Rc 2 1/2
303x603x720 356x513x1,067 356x513x1,247 356x903x1,247 356x903x1,489 406x1,400x1,385
46 74 87 135 170 280
Auto Drain Trap / Drain Valve

45 0.7MPa

Hitachi Filter ■Air-cooled (Without Built-in Dryer)


15—55kW (Single-stage and Two-stage)
Model DSP-22AⅡ DSP-37AⅢ DSP-55AⅡ DSP-37ATⅠ
DSP-15AⅡ DSP-22ATⅠ DSP-30ATⅠ
Item・Unit DSP-22VAⅠ DSP-37VAⅡ DSP-55VAⅠ DSP-37VAT
HAF-7.5BX HAF-11BX HAF-15BX HAF-22B HAF-37B HAF-55B HAF-75B HAF-100B HAF-125B HAF-160B HAF-200B HAF-240B MJ/h 77 117 166 225 118 145 158
Heat Generation
1.2 1.8 2.4 3.9 6.6 10.6 13.8 20 27.6 32 40 50 (kcal/h) (18,400) (28,000) (39,600) (53,800) (28,100) (34,600) (37,800)
Air Exhaust (air compressor) m3/min 65 100 120 100
30 Approx. Temp. Rise (exhaust air) ˚C 18 27 25 28 18 22 23
0.69 Maximum Pressure Loss (exhaust duct) Pa (mmAq) 20 (2)
Recommended Fan Capacity ① m /min
3
204 311 440 600 310 380 410
Compressed Air
Recommended Fan Capacity ② m3/min 86 95 130 150 130
1.57 0.97
45—120kW (Two-stage)
5−60 DSP-55ATN DSP-75ATN
Model DSP-45ATN DSP-90AN DSP-100AN DSP-120AN DSP-100VAN
2−60 Item・Unit DSP-55VATN DSP-75VATN
1 MJ/h 198 246 333 387 430 498 440
Heat Generation
(kcal/h) (47,300) (58,700) (79,700) (92,500) (102,800) (118,900) (105,000)
99.999 Air Exhaust (air compressor) m3/min 150 200 250 270
0.005 or Lower Approx. Temp. Rise (exhaust air) ˚C 20 25 25 24 26 28 25
Maximum Pressure Loss (exhaust duct) Pa (mmAq) 20 (2)
0.07
Recommended Fan Capacity ① m3/min 530 650 890 1,030 1,140 1,320 1,170
Rc3/4 Rc1 Rc11/2 Rc2 21/2 (Flange) 3 (Flange) 4 (Flange) Recommended Fan Capacity ② m3/min 180 230 280 300
92x237 130x290.5 160 x509 170 x591 170 x699 173x792 173x949 590 x1,512 590 x1,512 640 x1,735 132—240kW (Two-stage)
1 2 2.1 3 3.3 3.7 4.3 6 57 61 73 Model DSP-132A DSP-145A DSP-160A DSP-200A DSP-240A
Item・Unit
MJ/h 522 566 636 830 948
Heat Generation
(kcal/h) (125,000) (135,000) (152,000) (198,000) (226,000)
Multi Unit Controller (MULTI ROLLER EX) Air Exhaust (air compressor) m3/min 400〈200×2〉 440〈220×2〉 500〈250×2〉
Approx. Temp. Rise (exhaust air) ˚C 20 21 22 25 29
Maximum Pressure Loss (exhaust duct) Pa (mmAq) 20 (2)
Recommended Fan Capacity ① m3/min 1,400 1,500 1,700 2,200 2,500
Recommended Fan Capacity ② m3/min 480〈240×2〉 520〈260×2〉 600〈300×2〉
Single-phase AC100/200V (Common)
■Air-cooled (With Built-in Dryer)
50/60Hz (Common) 15—75kW (Single-stage and Two-stage)
4 8 12 Model DSP-22ARⅡ DSP-37ARⅢ DSP-55ARⅡ DSP-37ATRⅠ DSP-55ATRN DSP-75ATRN
DSP-15ARⅡ DSP-22ATRⅠ DSP-30ATRⅠ DSP-45ATRN
0 to 1 MPa (Digital Display) Item・Unit DSP-22VARⅠ DSP-37VARⅡ DSP-55VARⅠ DSP-37VATR DSP-55VATRN DSP-75VATRN
MJ/h 84 127 177 238 129 157 171 223 271 379
Operation Answer, Shutdown Heat Generation
(kcal/h) (20,100) (30,400) (42,200) (57,000) (30,600) (37,400) (40,800) (53,300) (64,700) (90,700)
Start, Stop, External Forced Start-up, Flow Volume Air Exhaust (air compressor) m3/min 65 100 120 100 150 200
Air Exhaust (air dryer) m3/min 18 20 30 60 70
Start, Stop, Load, PID Command
Approx. Temp. Rise (exhaust air) ˚C 18 27 25 28 18 22 23 20 25
Start, Shutdown, Auto Maximum Pressure Loss (exhaust duct) Pa (mmAq) 20 (2)
400×200×600 500×200×900 500×200×1,200 Recommended Fan Capacity ① m /min
3
223 338 470 630 340 420 450 600 720 1,020
Recommended Fan Capacity ② m3/min 106 122 140 160 162 166 250 360
19kg 32kg 37kg Recommended Fan Capacity ③ m3/min 20 27 30 36 30 32 36 70 130
15 16
OIL FREE SCREW Precautions, Memo

MEMO
■Water-cooled (Without Built-in Dryer)
15—75kW (Single-stage and Two-stage)
Model DSP-37WⅢ DSP-55WⅢ DSP-55WTN DSP-75WTN
DSP-15WⅠ DSP-22WⅠ DSP-45WⅢ DSP-45WTN
Item・Unit DSP-37VW DSP-55VW DSP-55VWTN DSP-75VWTN
MJ/h 8 12 15 18 22 27 28 37
Heat Generation
(kcal/h) (1,900) (2,800) (3,600) (4,300) (5,300) (6,400) (6,800) (8,800)
Recommended Fan Capacity ① m3/min 21 31 40 50 60 75 80 100

90—240kW (Two-stage)
Model DSP-100WN DSP-160WN DSP-240WN
DSP-90WN DSP-120WN DSP-132WN DSP-145WN DSP-200WN
Item・Unit DSP-100VWN DSP-160VWN DSP-240VWN
MJ/h 44 49 56 57 60 67 90 98
Heat Generation
(kcal/h) (10,400) (11,600) (13,400) (13,400) (14,400) (16,000) (21,500) (23,500)
Recommended Fan Capacity ① m3/min 120 130 150 160 180 240 260

■Water-cooled (With Built-in Dryer) Required Ventilation Capacity


15—75kW (Single-stage and Two-stage)
Model DSP-55WTRN DSP-75WTRN
DSP-45WTRN
Item・Unit DSP-55VWTRN DSP-75VWTRN
MJ/h 52 53 83
Heat Generation
(kcal/h) (12,300) (12,700) (19,800)
Recommended Fan Capacity ① m3/min 140 145 230

Required Power Transformer Capacity


Select an appropriate power transformer to secure required power source for a compressor.

17 18

Вам также может понравиться