: 13A052707E-E Page 1 of 67
Test Report
(Declaration of Conformity)
for
Electromagnetic Interference
of
Prepared for
Traco Electronic AG
Jenatschstrasse 1 CH-8002 Zurich
TEL.: +886 2 2698 9508
FAX.: +886 2 2698 1319
Prepared by
Table of Contents
1 General Information 6
1.1 Description of Equipment Under Test 6
1.2 Specifications Description 7
1.3 Details of Tested Supporting System 8
1.4 Test Facility 9
1.5 Measurement Uncertainty 10
1.6 Summary of Test Results 11
1.7 Measured Mode 12
1.8 Configuration of EUT Setup 12
1.9 Test Step of EUT 12
14 Photographs of Measurement 64
14.1 Power Line Conducted Emission Measurement 64
14.2 Radiated Emission Measurement 65
15 Photographs of EUT 66
15.1 Model Number: TML 100-112 66
15.2 Model Number: TML 100-112 C 67
Statement of Compliance
Applicant: Traco Electronic AG
Manufacturer: Traco Electronic AG
Product: Switching Power Module
Model No.: TML 100-112; TML 100-112 C; TML 100-115; TML 100-115 C;
TML 100-124; TML 100-124 C; TML 100-148; TML 100-148 C
Tested Power Supply: 230Vac, 50Hz
Date of Final Test: May 21, 2013
Revision of Report: Rev. 01
Measurement Procedures and Standards Used:
Emission: Immunity:
EN 55024: 2010
EN 55022: 2010
IEC 61000-4-2: 2008
EN 61000-3-2: 2006+A1: 2009+A2: 2009
IEC 61000-4-3: 2006+A1: 2007+A2: 2010
EN 61000-3-3: 2008
IEC 61000-4-4: 2004+A1: 2010
IEC 61000-4-5: 2005
IEC 61000-4-6: 2008
IEC 61000-4-8: 2009
IEC 61000-4-11: 2004
The measurement results in this test report were performed at Interocean EMC Technology
Corp. the responsibility of measurement result is only subject to the tested sample.
This report shows the EUT is technically compliance with the above official standards.
This report shall not be partial reproduced without written approval by Interocean EMC
Technology Corporation.
1 General Information
1.1 Description of Equipment Under Test
Product : Switching Power Module
Model Number : TML 100-112; TML 100-112 C; TML 100-115; TML 100-115 C;
TML 100-124; TML 100-124 C; TML 100-148; TML 100-148 C
Applicant : Traco Electronic AG
Jenatschstrasse 1 CH-8002 Zurich
Manufacturer : Traco Electronic AG
Jenatschstrasse 1 CH-8002 Zurich
Power Supply : Input: 90-264Vac, 47-63Hz
Output: The detail specification, please see “Specifications
Description” as below page.
Date of Test : Jul. 04 ~ 12, 2011 (For Test Mode: Mode: 1 ~ 4)
May 21 ~ 22, 2013 (For Test Mode: Mode: 5 ~ 8)
Additional Description : 1.) The Model Number “TML 100-112; TML 100-112 C; TML 100-115;
TML 100-115 C; TML 100-124; TML 100-124 C;TML 100-148;
TML 100-148 C” are representative selected in the test and
included in this report.
2.) For more detail specification about EUT, please refer to the user’s
manual.
Output
Model No.
Voltage Max. Current Max. Power
TML 100-112
12 Vdc 7.08 A
TML 100-112 C
85 W
TML 100-115
15 Vdc 5.66 A
TML 100-115 C
TML 100-124
24 Vdc 4.2 A
TML 100-124 C
100 W
TML 100-148
48 Vdc 2.1 A
TML 100-148 C
Note: “C” represents backplane differently.
Connected to mains
EUT
Load
Metal Case
RF Cable
0.8 m
0.4 m
LISN
LISN
Power Cord
0.4 m to vertical ground
Bonded to horizontal
Bonded to horizontal reference plane
ground plane
ground plane
Frequency Factor Meter Reading (dBμV) Emission Level (dBμV) Limits (dBμV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.150 0.14 60.50 45.80 60.64 45.94 66.00 56.00 -5.36 -10.06
0.177 0.14 55.00 39.10 55.14 39.24 64.61 54.61 -9.47 -15.37
0.213 0.14 48.88 35.03 49.02 35.17 63.11 53.11 -14.09 -17.94
2.834 0.09 43.52 28.40 43.61 28.49 56.00 46.00 -12.39 -17.51
3.873 0.13 44.91 28.86 45.04 28.99 56.00 46.00 -10.96 -17.01
10.689 0.50 48.30 32.60 48.80 33.10 60.00 50.00 -11.20 -16.90
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
3. Emission Level = Meter Reading + Factor.
4. Margin = Emission Level – Limits.
Frequency Factor Meter Reading (dBμV) Emission Level (dBμV) Limits (dBμV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.150 0.14 60.50 44.84 60.64 44.98 66.00 56.00 -5.36 -11.02
0.181 0.13 54.26 37.00 54.39 37.13 64.43 54.43 -10.04 -17.30
0.377 0.13 49.30 37.20 49.43 37.33 58.35 48.35 -8.92 -11.02
0.634 0.13 48.40 33.40 48.53 33.53 56.00 46.00 -7.47 -12.47
0.892 0.14 47.80 31.00 47.94 31.14 56.00 46.00 -8.06 -14.86
10.771 0.52 51.13 34.01 51.65 34.53 60.00 50.00 -8.35 -15.47
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
3. Emission Level = Meter Reading + Factor.
4. Margin = Emission Level – Limits.
Frequency Factor Meter Reading (dBμV) Emission Level (dBμV) Limits (dBμV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.150 0.14 60.10 44.30 60.24 44.44 66.00 56.00 -5.76 -11.56
0.162 0.14 57.70 39.60 57.84 39.74 65.36 55.36 -7.52 -15.62
1.873 0.13 42.30 25.80 42.43 25.93 56.00 46.00 -13.57 -20.07
2.994 0.08 44.20 28.80 44.28 28.88 56.00 46.00 -11.72 -17.12
10.170 0.48 44.86 33.60 45.34 34.08 60.00 50.00 -14.66 -15.92
14.505 0.68 46.50 36.40 47.18 37.08 60.00 50.00 -12.82 -12.92
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
3. Emission Level = Meter Reading + Factor.
4. Margin = Emission Level – Limits.
Frequency Factor Meter Reading (dBμV) Emission Level (dBμV) Limits (dBμV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.150 0.14 60.10 44.40 60.24 44.54 66.00 56.00 -5.76 -11.46
0.396 0.13 53.40 38.54 53.53 38.67 57.93 47.93 -4.40 -9.26
0.654 0.13 50.30 36.20 50.43 36.33 56.00 46.00 -5.57 -9.67
0.935 0.14 50.50 36.50 50.64 36.64 56.00 46.00 -5.36 -9.36
1.490 0.13 48.50 34.50 48.63 34.63 56.00 46.00 -7.37 -11.37
15.212 0.74 39.60 29.50 40.34 30.24 60.00 50.00 -19.66 -19.76
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
3. Emission Level = Meter Reading + Factor.
4. Margin = Emission Level – Limits.
Item Freq. Reading Factor Level Limit Margin Remark
Mark MHz dBuV dB dBuV dBuV dB
Item Freq. Reading Factor Level Limit Margin Remark
Mark MHz dBuV dB dBuV dBuV dB
Item Freq. Reading Factor Level Limit Margin Remark
Mark MHz dBuV dB dBuV dBuV dB
Item Freq. Reading Factor Level Limit Margin Remark
Mark MHz dBuV dB dBuV dBuV dB
RF Cable
4m
EUT
Item Freq. Reading Factor Level Limit Margin Remark
Mark MHz dBuV dB dBuV/m dBuV/m dB
Item Freq. Reading Factor Level Limit Margin Remark
Mark MHz dBuV dB dBuV/m dBuV/m dB
Item Freq. Reading Factor Level Limit Margin Remark
Mark MHz dBuV dB dBuV/m dBuV/m dB
Item Freq. Reading Factor Level Limit Margin Remark
Mark MHz dBuV dB dBuV/m dBuV/m dB
EMC EMISSION
TESTER EUT
Class B equipment
For Class B equipment, the harmonics of the input current shall not exceed the values given in
Class A equipment multiplied by a factor of 1.5.
Class C equipment
Harmonic order Maximum permissible harmonic current
expressed as a percentage of the input
current at the fundamental frequency
(n) %
2 2
3 30.λ*
5 10
7 7
9 5
11 ≤ n ≤ 39 3
(odd harmonics only)
*λis the circuit power factor
Class D equipment
Harmonic order Maximum permissible Maximum permissible
harmonic current harmonic current
Per watt
(n) (mA/W) (A)
3 3.4 2.30
5 1.9 1.14
7 1.0 0.77
9 0.5 0.40
11 0.35 0.33
13 ≤ n ≤ 39 3.85/n See Class A equipment
(odd harmonics only)
EMC EMISSION
TESTER EUT
Criterion Description
A The equipment shall continue to operate as intended without operator intervention. No
degradation of performance or loss of function is allowed below a performance level
specified by the manufacturer when the equipment is used as intended. The
performance level may be replaced by a permissible loss of performance. If the
minimum performance level or the permissible performance loss is not specified by
the manufacturer, then either of these may be derived from the product description
and documentation, and by what the use may reasonably expect from the equipment if
used as intended.
B After the test, the equipment shall continue to operate as intended without operator
intervention. No degradation of performance or loss of function is allowed, after the
application of the phenomena below a performance level specified by the
manufacturer, when the equipment is used as intended. The performance level may
be replaced by a permissible loss of performance.
During the test, degradation of performance is allowed. However, no change of
operating state or stored data is allowed to persist after the test.
If the minimum performance level (or the permissible performance loss) is not
specified by the manufacturer, then either of these may be derived from the product
description and documentation, and by what the user may reasonable expect from the
equipment if used as intended.
C Loss of function is allowed, provided the function is self-recoverable, or can be
restored by the operation of the controls by the user in accordance with the
manufacturer’s instructions.
Functions, and/or information stored in non-volatile memory, or protected by a battery
backup, shall not be lost.
10 cm
ESD Generator
Vertical
Coupling Insulation
Plane EUT
Ground
Connection (HCP)
470kΩ 470kΩ
80 cm Resister Resister
Temperature: 24.6 ℃; Humidity: 39 %; Atm pres: 101 Kpa; Test Engineer: Roy
PASS.
The performance criterion after tested EN 55024:
Air discharge ±2 kV, ±4 kV, ±8 kV: A B C
Contact discharge ±2 kV, ±4 kV: A B C
Indirect discharge (HCP) ±2 kV, ±4 kV: A B C
Indirect discharge (VCP Front, Left, Back, Right) ±2 kV, ±4 kV:
A B C
Chamber
3m
RF Cable
EUT
1m
80 cm
RF Power Amplifier
PASS.
The performance criterion after tested EN 55024:
Frequency range: 80 to 1000 MHz, Field strength: 3 V/m, 80% AM (1kHz),
Performance criterion: A B C
EUT
Insulation support
Grounding cable
Bounding
Metal Ground Plane
Open circuit output test voltage and repetition rate of the impulses
On I/O (input/output) signal, data
On power port, PE
and control ports
Level
Voltage peak Repetition rate Voltage peak Repetition rate
kV kHz kV kHz
1 0,5 5 or 100 0,25 5 or 100
2 1 5 or 100 0,5 5 or 100
3 2 5 or 100 1 5 or 100
4 4 5 or 100 2 5 or 100
Xa Special Special Special Special
NOTE 1: Use of 5 kHz repetition rates is traditional; however, 100 kHz is closer to reality. Product
committees should determine which frequencies are relevant for specific products or product types.
NOTE 2: With some products, there may be no clear distinction between power ports and I/O ports, in
which case it is up to product committees to make this determination for test purposes.
a
“X” is an open level. The level has to be specified in the dedicated equipment specification.
Temperature: 24.6 ℃; Humidity: 39 %; Atm pres: 101 Kpa; Test Engineer: Roy
PASS.
The performance criterion after tested EN 55024:
±1.0 kV input AC power port: Line + Neutral + PE
Performance criterion: A B C
Surge
EUT Generator
Controller Computer
PASS.
The performance criterion after tested EN 55024:
±0.5 kV (peak) Input AC power port: Line to line
Performance criterion: A B C
±1.0 kV (peak) Input AC power port: Line to line
Performance criterion: A B C
±0.5 kV (peak) input AC power port: Line to earth (ground)
Performance criterion: A B C
±1.0 kV (peak) input AC power port: Line to earth (ground)
Performance criterion: A B C
±2.0 kV (peak) input AC power port: Line to earth (ground)
Performance criterion: A B C
6dB Attenuator
50 terminator
30 cm
C.D.N. EUT AE C.D.N.
Main Power
10 cm
Metal Ground Plane
Temperature: 24.6 ℃; Humidity: 39 %; Atm pres: 101 Kpa; Test Engineer: Roy
PASS.
The performance criterion after tested EN 55024:
Frequency range: 0.15 to 80 MHz, Field strength: 3 V, 80% AM (1kHz),
Input AC power port.
Performance criterion: A B C
Induction coil
1/2 Dimension of EUT
EUT
Non-Conducted Table
PASS.
EUT
Grounding cable
Bounding
Metal Ground Plane
Class Xb X X X X X
a
Classes as per IEC 61000-2-4; see Annex B.
b
To be defined by product committee. For equipment connected directly or indirectly to the public
network, the levels must not be less severe than Class 2.
c
“25/30 cycles” means “25 cycles for 50 Hz test” and “30 cycles for 60 Hz test”.
Temperature: 24.6 ℃; Humidity: 39 %; Atm pres: 101 Kpa; Test Engineer: Roy
PASS.
The performance criterion after tested EN 55024:
> 95% reduction (Voltage Dips), 0.5 period A B C
> 30% reduction (Voltage Dips), 25 period A B C
> 95% reduction (Voltage Interruptions), 250 period A B C
14 Photographs of Measurement
14.1 Power Line Conducted Emission Measurement
Front View
Rear View
Front View
Rear View
15 Photographs of EUT
15.1 Model Number: TML 100-112