Error sources
Sensor
Installation
Instrumentation
Calibration
Session 2
Significance of errors
Managing errors
Rules of thumb
Sensor selection
Installation recommendations
Session 3
Calculating measurement system accuracy
Sensor selection
Performance
Calibration
Importance of Accuracy 5
Efficient production
Error Sources
Calibration
Other sources can produce errors but are difficult to These are a few other potential error
analyze without installation unique information. sources. Application specific information is
necessary to estimate the size of error.
Vibration
Mechanical Shock
Thermal Shock
Thermal Radiation
Nuclear Radiation
Significance of Errors 8
All others
Significance of Errors 9
Sensor
Interchangeability
Insulation resistance
Installation
Stem conduction
Time response
Lead wire
Calibration
Instrumentation
Transmitter
Controller
Recorder
11
Interchangeability 14
Interchangeability 16
Significance of Errors 17
Sensor
Interchangeability
Insulation resistance
Installation
Stem conduction
Time response
Lead wire
Calibration
Instrumentation
Transmitter
Controller
Recorder
Insulation resistance
Electrical resistance between the sensing circuit and the metallic
An important electrical check that should be
sheath of a PRT performed as part of any calibration. The
test is performed with 50 or 100 VDC
applied between the leads and sheath.
Insulation Resistance 19
Estimated Error
Standard Temp (°C) Min. IR (MΩ) (100 ohm PRT(°C))
IR decreases with an increase in
ASTM E1137 25 100 .0003 temperature and that’s why manufacturing
ASTM E1137 300 10 .0130 specifications are set high at room
ASTM E1137 650 2 .1700 temperature where the test is performed.
IEC 60751 25 100 .0003
IEC 60751 100 to 300 10 .0130
IEC 60751 301 to 500 2 .1200 Low IR can cause a significant error.
IEC 60751 501 to 850 .5 1.0000 Laboratory standards may have IR of 1000
megohms or may be measured in the
terraohm range. Higher is better.
Insulation Resistance 20
Significance of Errors 22
Sensor
Interchangeability
Insulation resistance
Installation
Stem conduction
Time response
Lead wire
Calibration
Instrumentation
Transmitter
Controller
Recorder
Stem Conduction 23
200°C
(High
Potential) Sensing Element
Stem Conduction 25
Difficult to analyze, can be very sensitive to depth. Because there are so many variables an
actual error value can be difficult to
Heat transfer conditions heavily influence the rule.
determine. Process fluid characteristics,
Error directly proportional to ΔT flow rate and ambient conditions are just a
few of the variables.
Stem Conduction 26
30.00
25.00
the error has disappeared. As you can see
Indicated Error (% Delta T)
10.00
5.00
0.00
0 2 4 6 8 10 12
-5.00
Im m e r s ion De pth (Inche s )
Stem Conduction 28
Fluid
Stem Conduction 29
Stem Conduction 31
Significance of Errors 32
Sensor
Interchangeability
Insulation resistance
Installation
Stem conduction
Time response
Lead wire
Calibration
Instrumentation
Transmitter
Controller
Recorder
of a step change in temperature while in water moving at 3 fps starts with the sensor in 0°C water and then
placed in room temperature water moving
at 3 fps.
Time Response 34
The less thermal resistance between the sensor and the process,
the better The fast response tip thermowell has a time
Smaller diameter probes constant of 4 seconds which equals that of
Direct Immersion or special fast tip thermowell a 0.25” diameter direct immersion sensor.
Time Response 35
100
90
This graph compares the time response of
80
several styles of sensors. The fastest is
70
the direct immersion style and the surface
Direct immersion
mount the slowest.
% of step change
60 Non-Intrusive
Surface, Comp, NI
50
Surface, Comp, Insul.
40
Indirect, Tip Sensitive in .260
30 ID well
Indirect, 200G in .260 ID well
20 Surface, NC, NI
3/8” - 1/4”
TIME RESPONSE Thermowells
with HTC
22/11 seconds Reduced Tip
Significance of Errors 37
Sensor
Interchangeability
Insulation resistance
Installation
Stem conduction
Time response
Lead wire
Calibration
Instrumentation
Transmitter
Controller
Recorder
Sensor
Interchangeability
Insulation resistance
Installation
Stem conduction
Time response
Lead wire
Calibration
Instrumentation
Transmitter
Controller
Recorder
Calibration Errors 43
Calibration Errors 44
calibration media
with the calibration. Each is very small but
Calibration standard still needs to be taken into consideration.
Resistance measurement device and interpolation errors
Sensor stability
To minimize:
Obtain a high quality/accuracy calibration for the sensor
Calibrate sensors at the correct intervals
Significance of Errors 46
Sensor
Interchangeability
Insulation resistance
Installation
Stem conduction
Time response
Lead wire
Calibration
Instrumentation
Transmitter
Controller
Recorder
Significance of Errors 47
Many sources contribute to the total error, some are PRT driven,
some are application driven.
Summary 49
Calibration
Instrumentation sensor not designed for the application.
Environment
Questions? 50
or
visit us at www.burnsengineering.com