Вы находитесь на странице: 1из 2

Project Job Ref.

PROPOSED RESIDENTIAL HOUSE 2018/09 /1 6


Section Sheet no./rev.
DESIGN OF MASONRY 2018/07/16 4 00
Calc. by Date Chk'd by Date App'd by Date
Namu 7/16/2018 Eng W akeru 7/16/2018 Meijer 9 /16/2018

MASONRY BEARING DESIGN TO BS5628-1:2005


TEDDS calculation version 1.0.02

Masonry details
Masonry type; Aggregate concrete blocks (25% or less formed voids)
Compressive strength of unit; p unit = 20.0 N/mm 2
Mortar designation; iii
Least horizontal dimension of masonry units; lunit = 100 mm
Height of masonry units; h unit = 200 mm
Category of masonry units; Category II
Category of construction control ; Normal
Partial safety factor for material strength ;  m = 3.5
Thickness of load bearing leaf; t = 200 mm
Effective thickness of masonry wall; tef = 200 mm
Height of masonry wall; h = 2400 mm
Effective height of masonry wall; h ef = 2400 mm

Beam to span in plane of wall

lb
B

Bearing details
Beam spanning in plane of wall
W idth of bearing; B = 200 mm
Length of bearing; lb = 200 mm
Compressive strength from Table 2 BS5628:Part 1 - aggregate concrete blocks (25% or less formed voids)
Mortar designation; Mortar = "iii"
Block compressive strength; p unit = 20.0 N/mm 2
Characteristic compressive strength (Table 2c); fkc = 5.55 N/mm 2
Characteristic compressive strength (Table 2d); fkd = 11.05 N/mm 2
Height of solid block; h unit = 200.0 mm ;
Least horizontal dimension; lunit = 100.0 mm
Project Job Ref.
PROPOSED RESIDENTIAL HOUSE 2018/09 /1 6
Section Sheet no./rev.
DESIGN OF MASONRY 2018/09 /16 5 00
Calc. by Date Chk'd by Date App'd by Date
Namu 9 /16/2018 Eng W akeru 9 /16/2018 Meijer 9 /16/2018

Block ratio; ratio = h unit / l unit = 2.0


Ratio between 0.6 and 4.5 - OK
Characteristic compressive strength; fk = 11.05 N/mm 2

Loading details
Characteristic dead load; G k = 80 kN
Characteristic imposed load; Q k = 26 kN
Design load on bearing; F = (G k  1.4) + (Q k  1.6) = 154.2 kN

Masonry bearing type


Bearing type; Type 2
Bearing safety factor;  bear = 1.50

Check design bearing without a spreader


Design bearing stress; fca = F / (B  lb ) = 3.854 N/mm 2
Allowable bearing stress; fcp =  bear  f k /  m = 4.736 N/mm 2
PASS - Allowable bearing stress exceeds design bearing stress

Check design bearing at 0.4  h below the bearing level


Slenderness ratio; h ef / t ef = 12.00
Eccentricity at top of wall; e x = 0.0 mm
From BS5268:1 Table 7
Capacity reduction factor;  = 0.99
Length of bearing distributed at 0.4  h; ld = 1160 mm
Maximum bearing stress; fca = F / (l d  t) = 0.664 N/mm 2
Allowable bearing stress; fcp =   f k /  m = 3.126 N/mm 2
PASS - Allowable bearing stress at 0.4  h below bearing level exceeds design bearing stress