REVISIONS
#
SCALE :
SIDE ELEVATION
DRAWN BY :
PLAN
PROJECT # :
DATE :
SPECIFICATIONS CONFORM TO LOCAL
I CERTIFY THAT THESE PLANS AND
FLORIDA PE # 55382
DEREK P. CRONIN
CERTIFICATE OF AUTHORIZATION NUMBER: 8597
CRONIN ENGINEERING, INC.
6627 WILLOW PARK DRIVE, SUITE 201
SCHIEFLOE
ESPEN
A-1 SITE PLAN & SHEET INDEX S-1 RELOCATION PLAN
A-2 PLUMBING AND NOTE PLAN S-2 PILE LAYOUT PLAN
A-3 DIMENSION PLAN S-3 PILE DIMENSION PLAN
A-4 ROOF PLAN S-4 FLOOR TRUSS LAYOUT PLAN
A-5 FRONT & REAR ELEVATIONS S-5 HEADER PLAN & ROOF TRUSS LAYOUT PLAN
A-6 RIGHT & LEFT ELEVATIONS S-6 SCHEDULES AND NOTES PROJECT DATA
OCCUPANCY TYPE RESIDENTIAL "R1-10"
A-7 BACK BUILDING FRONT & REAR ELEVATIONS S-7 SECTIONS CONSTRUCTION TYPE
CODE REFERENCE
TYPE "VI" (UNPROTECTED)
FBC FIFTH ADDITION (2014)
A-8 BUILDING SECTIONS S-8 SECTIONS AND DETAILS FLOOD ZONE ZONE AE11 + AE12
DRAWN BY :
PROJECT # :
ARCHITECTURAL NOTES
DATE :
GENERAL NOTES:
1.) COMPLY WITH ALL STATE, COUNTY, AND LOCAL BUILDING CODES, ORDINANCES
FLORIDA PE # 55382
DEREK P. CRONIN
3.) PROVIDE ATTIC VENTILATION WITH:
A. LOUVERED VENTS AT GABLE ENDS EQUAL TO 1 SQ. FT. PER 150 SQ. FT. OF ATTIC.
B. THERMOSTATICALLY CONTROLLED POWER VENTILATORS, OR APPROVED EQUAL.
4.) PROVIDE TERMITE PROTECTION OVER GRAULAR FILL.
5.) IN ALL BEDROOMS, WINDOWS MUST MEET EMERGENCY EGRESS REQUIREMENTS.
6.) ATTIC VENTILATION SHALL BE A MINIMUM OF ONE SQUARE FOOT
150 SQUARE FEET OF SURFACE AREA
7.) ATTIC ACCESS SHALL BE SWING DOWN HINGE TYPE.
ALL ATTIC ACCESS OPENINGS MUST BE CONSTRUCTED WITH OUTSWING PANELS OR DOORS
8.) ACCESS FROM GARAGE TO RESIDENCE SHALL BE THROUGH STEEL OR 1-3/4" WOOD DOOR.
SOIL:
CONCRETE:
1.) FOUNDATIONS - 3000 P.S.I. @ 28 DAYS, TYPE II CONCRETE, 6 BAG.
NAPLES, FL 34109
2.) FLOOR SLABS - 2500 P.S.I. @ 28 DAYS (4" CONCRETE ON 6 MIL POLYETHYLENE
VAPOR BARRIER ON 4' SAND FILL) MAX. SLUMP = 4"
3.) PROVIDE CONSTRUCTION JOINTS @ 400 SQ. FT. MAXIMUM IN SLABS.
P:\AAAA PROJECT FILES JULY4 2006\2000 OWNERS\2400\2494 Schiefloe Residence\Architectural & Structural\12-11-15 Schiefloe Structural.dwg, 12/11/2015 4:50:41 PM
4.) WALKS AND DRIVES - 2500 P.S.I. @ 28 DAYS, TYPE II CONCRETE, 6 BAG
WITH AIR ENTRAINMENT.
MASONRY:
1.) CONCRETE BLOCK UNITS - GRADE N: FM = 1350 P.S.I.
2.) GROUT - 3000 P.S.I.
3.) MORTAR - TYPE S - 1800 P.S.I.
4.) PROVIDE DURO-O-WIRE @ 16" O.C. VERTICAL, 9 GAUGE STEEL.
5.) ALL CELLS WITH RE-BAR TO BE GROUTED SOLID.
GLASS:
1.) ALL EXTERIOR AND INTERIOR GLAZING TO COMPLY WITH LOCAL CODES.
PLUMBING:
1.) WATER HEATER TO BE ELECTRIC 52 GAL. CAPACITY.
2.) WATER CLOSETS - 4 GAL / FLUSH MAXIMUM.
3.) SHOWER HEADS - 3 G.P.M. MAXIMUM.
4.) SINK FAUCETS - 3.5 G.P.M. MAXIMUM.
5.) LAVATORY FAUCETS - 3.5 G.P.M. MAXIMUM.
6.) DISHWASHER TO HAVE AIR GAPS INSTALLED.
7.) PROVIDE WATER HEATER WITH TEMPERATURE RELIEF VALVE.
8.) ALL WATER SUPPLY PIPES MATERIAL AND INSALLATION PER LOCAL CODES.
9.) ALL WASTE AND VENT PIPE MATERIAL AND INSTALLATION PER LOCAL CODES.
10.) PROVIDE LOCATION IN PIPING FOR ATTACHMENT OF A SOFTNER SYSTEM.
NAPLES, FLORIDA
ELECTRICAL:
ELECTRIC SERVICE PER LOCAL CODES AND LOCAL UTILITY.
SCHIEFLOE
ESPEN
GENERAL NOTES
1. VERTICAL WALL REINFORCEMENT TO BE #5 AT 4' 0" ON CENTER MAX.
AND AT EACH SIDE, OF OPENINGS LESS THAN 6' 0".
ALL OPENINGS GREATER THAN 6' 0" SHALL RECEIVE 2 #5 BARS.
2. 8" BLOCK MASONARY WALLS SHALL NOT EXCEED 4'-0" IN LENGTH W/OUT
VERTICAL REINFORCEMENT.
3. HORIZONTAL MASONARY REINFORCEMENT IS REQ'D. IN ALL 8"
BLOCK MASONARY WALLS OVER 10'-0" HIGH.
4. WHERE REQUIRED, HORIZONTAL REINFORCEMENT SHALL BE PLACED AT EVERY OTHER COURSE.
ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE STANDARD BUILDING CODE (SBC)
AND STATE AND LOCAL CODES.
18
P:\AAAA PROJECT FILES JULY4 2006\2000 OWNERS\2400\2494 Schiefloe Residence\Architectural & Structural\12-11-15 Schiefloe Structural.dwg, 12/11/2015 4:50:42 PM
ROOF NOTES:
17 TONS (POOL)
NET ALLOWABLE PILE TONNAGE
12 TONS (STRUCTURE)
17 TONS (POOL)
NET ALLOWABLE PILE TONNAGE
12 TONS (STRUCTURE)
17 TONS (POOL)
NET ALLOWABLE PILE TONNAGE
12 TONS (STRUCTURE)
8Q
8Q
8L
8Q
8J
8J
8Q
8L
8B
8M
8C
8C
8I
8H
8O
8P
8B
8C
8A
8O
8B
8M
8A
8A
8I
8H
8O
8P
8O
8I
8H
8M
8F
8F
8F
8G
8K
8G
8K
8E
8E
8O
8O
8P
8P
DETAIL A
DETAIL A
C-3
C-3
C-3
9E
9E
C-3
WB-3
WB-3
9E
9E C-3
C-3
DETAIL B
DETAIL B
WB-3
WB-3
C-3
C-3
9E
DETAIL A
DETAIL A
WB-3 WB-3
9E
9E
WB-3
WB-3
9E
WB-3
WB-3
C-3
C-3
9E
DETAIL A
DETAIL A
C-2
C-2
C-2
C-2
WB-2 WB-2
C-2
EXIST. (2) 2X8 EXIST. (2) 2X8 EXIST. (2) 2X8
WB-2
9F
9G
WB-2
9D
C-2
EXIST. (2) 2X8
W/FLITCH PLATE
C-2
DETAIL B
DETAIL B
9C
9C C-2
WB-2
WB-2 WB-2
C-2
EXIST. (2) 2X8
W/FLITCH PLATE
9C
9D
EXIST. (2) 2X8
C-2
C-2
C-2
W/FLITCH PLATE
EXIST. (2) 2X8
W/FLITCH PLATE
WB-1
C-1
C-1
C-1
C-1
C-1
C-1
9C
9C
9C
9H
9H
C-1
WB-1
9H
9D
C-1
C-1
REVISIONS
Vult = 170 MPH ULTIMATE DESIGN WIND SPEED COLUMN SCHEDULE
COMPONENT AND CLADDING (BASED ON Vult) EXPOSURE D
ULTIMATE DESIGN PRESSURES (LRFD) PSF COLUMN COLUMN DESCRIPTION
C-1
ROOF ZONE AREA APPLIED DESIGN PRESSURE
1
10 SF + 45.1 / - 72.9 PSF C-2
20 SF + 38.2 / - 71.0 PSF
#
50 SF + 33.3 / - 68.5 PSF
C-3
100 SF + 29.5 / - 66.6 PSF
2
10 SF + 41.9 / - 122.2 PSF
20 SF + 38.2 / - 109.2 PSF
50 SF + 3.33 / - 94.5 PSF
100 SF + 29.5 / - 85.3 PSF
SCALE :
3
10 SF + 41.9 / - 184.0 PSF
20 SF + 38.2 / - 160.4 PSF C-7
SCHEDULES
AND NOTES
50 SF + 3.33 / - 145.7 PSF
100 SF + 29.5 / - 134.7 PSF
DRAWN BY :
C-8
WALL ZONE AREA APPLIED DESIGN PRESSURE
4
10 SF + 72.9 / - 79.1 PSF C-9
20 SF + 69.6 / - 75.7 PSF
50 SF + 65.2 / - 71.4 PSF C-10
100 SF + 62.0 / - 68.2 PSF
101 + SF + 54.3 / - 60.5 PSF C-11
5
PROJECT # :
10 SF + 72.9 / - 97.6 PSF
C-12
20 SF + 69.6 / - 91.0 PSF
50 SF + 65.2 / - 82.3 PSF
100 SF + 62.0 / - 75.7 PSF
101 + SF + 54.3 / - 60.5 PSF
DATE :
SPECIFICATIONS CONFORM TO LOCAL
I CERTIFY THAT THESE PLANS AND
FLORIDA PE # 55382
DEREK P. CRONIN
DOORS AND WINDOWS INCLUDED
PRESSURES CALCULATED USING (Vult x 0.6) WHICH IS EQUIVALENT TO Vasd
ALLOWABLE STRESS DESIGN PRESSURE (ASD) PSF
AREA OPENING INTERIOR ZONE END ZONE
0 - 10 SF + 43.8 / - 47.5 PSF + 43.8 / - 58.5 PSF
11 - 20 SF + 41.7 / - 45.4 PSF + 41.7 / - 54.6 PSF
21 - 50 SF + 39.0 / - 42.7 PSF + 39.0 / - 49.4 PSF COLUMN C-6
NAPLES, FL 34109
P:\AAAA PROJECT FILES JULY4 2006\2000 OWNERS\2400\2494 Schiefloe Residence\Architectural & Structural\12-11-15 Schiefloe Structural.dwg, 12/11/2015 4:50:49 PM
HANGER SCHEDULE
HANGER HANGER DESCRIPTION
H-1
SCHIEFLOE
ESPEN
DEEP BEAM NOTE TYPICAL TIE BEAM REINFORCEMENT DETAIL CONCRETE BEAM SCHEDULE
18
P:\AAAA PROJECT FILES JULY4 2006\2000 OWNERS\2400\2494 Schiefloe Residence\Architectural & Structural\12-11-15 Schiefloe Structural.dwg, 12/11/2015 4:50:49 PM
ESPEN
S-10
NAPLES, FL 34109
PHONE: 593-2157 FAX: 593-8820 DEREK P. CRONIN
SCHIEFLOE FLORIDA PE # 55382 DATE : PROJECT # : DRAWN BY : SCALE : # REVISIONS DATE