Tehnical instructions
Cm Pelet-set
REGULATION
120°C
30%
80°C
15k 55°C
0% 50°C
Cm Pelet-set
TURPS- 09/2017-v1_14
Screen
SWITCHING ON
After turning on the main switch, screen will display language selection menu and software version.
You can choose between various languages. To select the language, press the flag of language you want.
Software version
Boiler power
- 14 kW (Cm Pelet-set 14)
- 20-35 kW (Cm Pelet-set 35)
- 40/50 kW (Cm Pelet-set 50)
- 60-90 kW (Cm Pelet-set 90)
Language selection
If option "Language selection" is set to OFF under "DISPLAY" menu, initial message screen will be shown (picture
below). This screen will be shown as long it's set in the "Initial message time" option, under "DISPLAY" menu or until you
press "OK" button.
Software version
Boiler power
- 14 kW (Cm Pelet-set 14)
- 20-35 kW (Cm Pelet-set 35)
- 40/50 kW (Cm Pelet-set 50)
- 60-90 kW (Cm Pelet-set 90)
’’OK’’ button
When turning on the main switch, touch screen must not be pressed. Otherwise
regulation will enter firmware update mode which is used only by authorized
technican. If this happens, please turn off main switch and turn it back on without
pressing the touch screen.
MAIN MENU
The main menu is used to select the desired submenu. To select a specific submenu you must press the appropriate icon
on the screen. To switch between the ’’Main menu’’ and ’’Boiler working display’’ press the button ’’View selection’’. To
switch between graphic view, numeric view or additional equipment of the boiler press ’’Boiler operation view’’ button.
Time
Date
View selection:
main menu / work
BUTTONS
SYMBOLS
1 9 10 11 12 13
6 7 8
Symbols:
1 - Boiler temperature
2 - Fuel level *
3 - Transporter working
4 - Photocell
5 - Flame symbol
6 - Igniter working
7 - Burner fan working
8 - Burner fan rpm
9 - Burner working hours counter
10 - Burner working hours reset buttom
11 - Dynamic configuration view
(view is depending of set configuration)
12 - Work mode (winter/summer) / Additional
equipment view (cascade, wifi...)
13 - Outside temperature
* - additional equipment
SYMBOLS
60°C
Room thermostat
Hydraulic crossover with the
current temperature
(there are configuration without
temp. sensor)
Heating circuit
3-way diverter valve (showing the
open and closed pipe)
55°C
Domestic hot water tank
with current temperature Chimney sweeper
3-way mixing valve with actuator and 4-way mixing valve with actuator and
return flow temp. sensor return flow temp. sensor
+ pump + pump
A B
C D
A - this menu is used to set the parameters that have numerical values (°C, RPM, time...)
example: adjust the burner fan rpm, adjusting the boiler temp. etc...
B - this menu is used to set parameters that must be selected (marked) to be enabled and there can be multiple selected
(enabled) items
NOTE: some enabled options disable another one (they can't be enabled at the same time)
example: enable additional equipment: flap, air cleaning, CM2K, Cm-WiFi-box...
C - this menu is used to set the parameters that must be selected but there can be only one selected item
example: set the type of the DHW sensor
D - this menu is used to set the parameters where are many items to be adjusted
example: adjust the burner working parameters on power P2
1 5
1 - parameter you are adjusting
2 2 - value adjustment box
3 - selected option (only one option can be selected)
3 4 - confirm button
5 - factory value
1 3
1 - parameter you are adjusting
2 - items that can be enabled
2 3 - next page button
4 - confirm button
5 - selected (enabled) item
5 6 - deselected (disabled) item
4
6
1 4
1 - parameter you are adjusting
2 2 - switch between sheets (only for parameters which
have multiple sheets)
3 - parameter description
3 5 4 - parameter current value (press 2 times to enter
adjusting mode)
5 - up/down scroll buttons
NOTE: after parameter changing press the "CONFIRM" button to store new value. If you don't want to save the set
value, press "BACK" button.
1.0. MAINTENANCE
Cleaning: this option is used to start the burner fan on the set RPMs to
clean the burner grate (note: depending of the pellets quality grate will
be more or less clean. After this procedure, burner grate should be
removed and cleaned and the burner head should also be cleaned.)
Burner fan: this option sets the burner fan RPMs during cleaning
1.1.1. CLEANING
Press the "START" button to start the burner fan for 10 min.
After pressing the "START" button countdown is started for 10 min,
after which burner fan stops automaticaly
Possible adjustment:
- Factory adjustment: 3000 rpm
- Minimal adjustment value: 500 rpm
- Maximal adjustment value: 3000 rpm
NOTE: burner cleaning option is not replacing the need for manual
cleaning of the burner and burner grate. It should be manually cleaned
regulary according to the technical manual.
2.0. TEMPERATURE
Temperature menu shows only items applicable to the set configuration. In next section of the manual all avalible
configurations and schemes are listed.
Availible temperature settings will be described at every individual configuration and scheme in
"CONFIGURATIONS" section of this manual.
NOTE: this is only representation picture, actual possible adjustment depends on set configuration.
This option is used to set the burner working time according to the set time. You can set 3 tables with different settings
and only 1 table can be active. You can set ON/OFF 3 times during 1 day and every day can be individualy set.
NOTE: in the same way you can set other schedules: BOILER, DHW, RECIRCULATION
3.1.1. SCHEDULE
This option is used to select active "SCHEDULE TABLE" that you have set
Possible adjustment:
- Factory adjustment: OFF
- Table 1
- Table 2
- Table 3
COPY PASTE
BUTTON BUTTON
4. HISTORY
This option is used to see the
history of the occured "ERRORS"
and "WARNINGS"
List of all error codes are listed in the "Cm Pelet-set manual"
3
List of all warning codes are listed in the "Cm Pelet-set manual"
3
5. OPERATION
This menu is used to set various parameters, enable/disable various additional equipment and functions, various work
modes, manual test etc.... This menu is designed for end user.
NOTE:
some of the options in this menu are GREYED OUT (disabled) and they can't be changed.
They are only shown to see settings/values of some options.
View in this menu depend of selected options and additional equipment.
This option is used to check relay outputs, connection to the electric devices and the working of the electric devices.
Items:
- Burner fan - you can check working of the burner fan on 2 speeds (max rpm and 1700 rpm) - when you start the test,
measured rpms are displayed on screen
- Feeder screw - you can check working of the feeding transporter
- Heater + burner fan - you can check working of the burner heater (igniter) - to protect the heater from burning out,
burner fan is started automatically when you start the heater
- Pump P1/DHW/RECIRCULATION - you can check working of the connected pumps
- 1. Circuit / 2. Circuit - you can check working of the devices of the mixing heating circuits (pumps, motor valves open
close)
- Additional equipment - submenu for manual test of the installed additional equipment
NOTE: Items displayed in this menu and in "Additional equipment" submenu depends of set configuration and
installed additional equipment.
5.5. SAVE/LOAD
This option is used to save parameters, load / load service parameters
and delete saved parameters.
You can save multiple setting under different names and you can load
and delete saved setting.
5.6.1. SENSORS
This option is used for adjusting the sensors type (NTC 5K or PT1000)
Factory: PT1000
Option: PT1000 / NTC 5K
5.6.2. PHOTOCELL
This option is used for adjusting photocell parameters
NOTE:
some parameters are shown in"OPERATION" menu but can't be
changed. They can be changed only in "INSTALLATION" menu
which is under PIN (only for authorized serviceman).
If there are more than 2 mixing heating circuits enabled you can switch view betwen them with buttons.
2 1
05:08
9
5°C
2a 3a 5a
1a 6a
50.0°C
8.a
22.0°C +5.0°C
58°C -°C
x
7a
4a 22°C
1 50.0°C
-°C
5 20.0°C +0.0°C
8 OFF
x
45°C 20°C
7
4
2 3 6
For each heating circuit can be specifically select items.
For example, you can Include / exclude heating circuits, turn on/off room corrector, choose heating type in each circuit
(radiators / floor), choose the mode (day / night).
Items 1a - 8a have the same meaning as items 1-8 (described above) which
only relate to 2. heating circuit or some other circuit depend how many circuits
is selected.
Regulation can control up to two mixing heating circuits. They must be enabled and set under "INSTALLATION" menu.
To make adjustment of each circuits go to the "OPERATION" menu then "STANDARD EQUIPMENT" menu.
Possible selection:
Factory: ON
Option: ON, OFF
By using this option you can enable/disable heating circuits.
Possible selection:
Factory: 1.0
Option: 0.1 - 4.0
By using this option you can set heating curve value.
Possible selection:
Factory: 1.0
Option: 0,1 - 5,0
By using this option you can set correction value.
Possible selection:
Factory: 20,0°C
Option: 5.0°C - 30.0°C
By using this option you can set day room temperature.
Possible selection:
Factory: 20,0°C
Option: 5.0°C - 30.0°C
By using this option you can set night room temperature.
Possible selection:
Factory: DAY TEMP.
Option: Day temp. / Night temp. / Table
By using this option you can set working mode of the heating circuit
By using this option you can set table for working mode of the heating circuit.
NOTE: you can change settings of any heating circuit in the same way.
Options:
- Air cleaning - turn on/off burner air cleaning
- Flap - turn on/off burner flap
- External control - turn on/off external control (start)
- Cascade - turn on/off the cascade and set some of its options
- CM-GSM - turn on/off CM-GSM module
- Internet supervision - turn on/off internet control and adjust some of
its options
- CMSR100 - turn on/off fuel level sensor and adjust some of its
options
- Suction system - turn on/off suction system and adjust some of its
options
NOTE:
additional equipment must be enabled under "INSTALLATION"
menu (PIN required) and only then is shown in this menu.
Some of the items shown here can be adjusted only under
"INSTALLATION" menu and can be changed only by authorized
serviceman.
Possible adjustment:
Freeze guard:
- Factory adjusted: OFF
- Options: ON / OFF
Type of protection:
- Factory: "Heating + Pumps"
- Options: "Heating+Pumps" / "Pumps only"
Option:
- Factory: "To._min/Taf_min"
- Options: "To._min/Taf_min" / "Toutside"
Possible adjustment:
- Factory adjusted: WINTER
- Options: WINTER (heating circuits + DHW) / SUMMER (only DHW)
Posible adjustment:
- Factory adjustment: 0 min (OFF)
- Options: 0 - 360 min
NAPOMENA: this option DOESN’T EXLUDE the need for manual cleaning of the burner grate and it must be done
according the intervals written in the Cm Pelet-set manual.
6. DISPLAY
7. INFO
This option is used to see various informations regarding regulation and burner
Options:
- Statistics - you can see working times of various parts (burner working, working in summer mode, freeze guard,
burner starts, burner fan working, heater working, heater starutups, screew working, pumps working...)
- Software version - you can see burner power (14 kW, 20-35 kW, 40/50 kW or 90 kW), regulation software version and
WiFI ID number (if Cm WiFi-box is installed)
- Selected configuration - you can see set configuration
- Current file - you can see which saved file is currently in use
- Selected burner power - you can see set burner power
9. CORRECTION
1 2 3
This option is used make correction of pellet delivery. You can decrease delivery by 3 steps. Steps are factory
configurated (or configured by authorized serviceman in "INSTALLATION" menu, under PIN) for every working stage
(power). Icon changes according the set step. "0" is no change and factory set.
10
10
Options:
- Chimney sweeper - you can enable/disable "CS" mode
- Power - you can set burner power for "CS" mode
- Minimum boiler temerature - you can set the minimum boiler temperature for "CS" mode
"CS MODE" - this mode enables you make flue gas measurement on selected burner power and set minimum boiler
temperature. In this mode boiler will be exluded from cascade, external control etc. and work only according boiler
temperature. Also in this mode modulation temperatures are lower so burner will modulate later, to enable longer
measurement on set power.
11. INSTALLATION
11
13. CONFIGURATIONS
1 - Boiler + Cm Pelet-set
2 - Accumulation tank
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - Accumulation tank upper temp. sensor (BUFFER1)
5 - Accumulation tank lower temp. sensor (BUFFER2)
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
bar
1 2
1 - Boiler + Cm Pelet-set
2 - Accumulation tank
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - Accumulation tank upper temp. sensor (BUFFER1)
5 - Accumulation tank lower temp. sensor (BUFFER2)
6 - Mixing heating circuit
7 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tbuf min.: 20°C (5-85°C)
bar
4 6
7
1 2 M
1 - Boiler + Cm Pelet-set
2 - Accumulation tank
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - Accumulation tank upper temp. sensor (BUFFER1)
5 - Accumulation tank lower temp. sensor (BUFFER2)
6 - Mixing heating circuit (2x)
7 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
8 - 2. circuit flow sensor (CIRCUIT2) + pump (P5) + actuator (MVAL2)
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tbuf min.: 20°C (5-85°C)
6
bar
4 6
1 2 8 7
M M
1 - Boiler + Cm Pelet-set
2 - Accumulation tank
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - Accumulation tank upper temp. sensor (BUFFER1)
5 - Accumulation tank lower temp. sensor (BUFFER2)
6 - DHW tank
7 - DHW tank pump (P2)
8 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
8
1 2 2
7
1 - Boiler + Cm Pelet-set
2 - Accumulation tank
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - Accumulation tank upper temp. sensor (BUFFER1)
5 - Accumulation tank lower temp. sensor (BUFFER2)
6 - Mixing heating circuit
7 - DHW tank
8 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
9 - DHW tank pump (P2)
10 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°(10-70°C)
dTdhw: 5°C (3-20°C)
Tbuf min.: 20°C (5-85°C)
bar
4 6
10
1 2 8 7
M 9
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°(10-70°C)
dTdhw: 5°C (3-20°C)
Tbuf min.: 20°C (5-85°C)
6
bar
4 6
11
1 2 8 9 7
M M 10
1 - Boiler + Cm Pelet-set
2 - Accumulation tank
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - Accumulation tank upper temp. sensor (BUFFER1)
5 - Accumulation tank lower temp. sensor (BUFFER2)
6 - DHW tank
7 - DHW recirculation (P3)
8 - DHW tank pump (P2)
9 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°(10-70°C)
dTdhw: 5°C (3-20°C)
bar
7
4
1 2 9 6
8
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°(10-70°C)
dTdhw: 5°C (3-20°C)
Tbuf min.: 20°C (5-85°C)
bar
8
4 6
1 2 9 11 7
M 10
1 - Boiler + Cm Pelet-set
2 - Accumulation tank
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - Accumulation tank upper temp. sensor (BUFFER1)
5 - Accumulation tank lower temp. sensor (BUFFER2)
6 - Mixing heating circuit
7 - DHW tank
8 - DHW recirculation (P3)
9 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
10 - 2. circuit flow sensor (CIRCUIT2) + pump (P5) + actuator (MVAL2)
11 - DHW tank pump (P2)
12 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°(10-70°C)
dTdhw: 5°C (3-20°C)
Tbuf min.: 20°C (5-85°C)
6
bar
8
4 6
1 2 7
M M
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
bar
1 2
5
M
3
1 - Boiler + Cm Pelet-set
2 - Accumulation tank
3 - 3-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - Accumulation tank upper temp. sensor (BUFFER1)
5 - Accumulation tank lower temp. sensor (BUFFER1)
6 - DHW tank
7 - DHW tank pump (P2)
8 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°(10-70°C)
dTdhw: 5°C (3-20°C)
bar
8
1 2 7 6
5
M
3
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°(10-70°C)
dTdhw: 5°C (3-20°C)
Tbuf min.: 20°C (5-85°C)
bar
4 6
10
1 2 8 7
M 9
5
M
3
1 - Boiler + Cm Pelet-set
2 - Accumulation tank
3 - 3-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - Accumulation tank upper temp. sensor (BUFFER1)
5 - Accumulation tank lower temp. sensor (BUFFER2)
6 - DHW tank
7 - DHW recirculation (P3)
8 - DHW tank pump (P2)
9 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°(10-70°C)
dTdhw: 5°C (3-20°C)
bar
7
4
1 2 8 9 6
5
M
3
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°(10-70°C)
dTdhw: 5°C (3-20°C)
Tbuf min.: 20°C (5-85°C)
bar
8
4 6
1 2 9 11
M 10
5
M
3
HV
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
Temperatures:
Boiler temp.: 80°C (70-90°C)
bar
Temperatures:
Boiler temp.: 80°C (70-90°C)
bar
1 5
M
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - Mixing heating circuit (2x)
5 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
6 - 2. circuit flow sensor (CIRCUIT2) + pump (P5) + actuator (MVAL2)
Temperatures:
Boiler temp.: 80°C (70-90°C)
4
bar
1 6 5
M M
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
6
1 5 4
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - Mixing heating circuit
5 - DHW tank
6 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
7 - DHW tank pump (P2)
8 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
8
1 6 5
M 7
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
4
bar
9
1 7 6 5
M M 8
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - DHW tank
5 - DHW recirculation (P3)
6 - DHW tank pump (P2)
7 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
1 6 7 4
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
6
4
1 7 9 5
M 8
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - Mixing heating circuit
5 - DHW tank
6 - DHW recirculation (P3)
7 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
8 - 2. circuit flow sensor (CIRCUIT2) + pump (P5) + actuator (MVAL2)
9 - DHW tank pump (P2)
10 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
4
bar
6
4
1 8 7 10 5
M M 9
Temperatures:
Boiler temp.: 80°C (70-90°C)
bar
2
M
3
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - Mixing heating circuit
5 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
Temperatures:
Boiler temp.: 80°C (70-90°C)
bar
1 5
M
2
M
3
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
6
1 5 4
2
M
3
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - Mixing heating circuit
5 - DHW tank
6 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
7 - DHW tank pump (P2)
8 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
8
1 6 5
M 7
2
M
3
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
1 6 7 4
2
M
3
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - Mixing heating circuit
5 - DHW tank
6 - DHW recirculation (P3)
7 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
8 - DHW tank pump (P2)
9 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
6
4
1 7 9 5
M 8
2
M
3
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
bar
1 4
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - CRO temp. sensor (BUFFER1)
5 - Mixing heating circuit
6 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
bar
1 4 6
M
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
5
bar
1 4 7 6
M M
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - CRO temp. sensor (BUFFER1)
5 - DHW tank
6 - DHW tank pump (P2)
7 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
7
1 4 5
6
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
9
1 4 7 6
M 8
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - CRO temp. sensor (BUFFER1)
5 - Mixing heating circuit (2x)
6 - DHW tank
7 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
8 - 2. circuit flow sensor (CIRCUIT2) + pump (P5) + actuator (MVAL2)
9 - DHW tank pump (P2)
10 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
5
bar
10
1 4 8 7 6
M M 9
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
1 4 8 5
7
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way themostatic mixing valve + pump (P1)
(return flow protection)
4 - CRO temp. sensor (BUFFER1)
5 - Mixing heating circuit
6 - DHW tank
7 - DHW recirculation (P3)
8 - 1. circuit flow sensor (CIRCUIT1) + pump (P4) + actuator (MVAL1)
9 - DHW tank pump (P2)
10 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
7
5
1 4 8 10 6
M 9
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
5
bar
7
5
1 4 8 9 11 6
M M 10
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - CRO temp. sensor (BUFFER1)
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
bar
1 4
2
M
3
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
bar
1 4 6
M
2
M
3
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - CRO temp. sensor (BUFFER1)
5 - DHW tank
6 - DHW tank pump (P2)
7 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
7
1 4 5
6
2
M
3
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
5
bar
9
1 4 7 6
M 8
2
M
3
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 3-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - CRO temp. sensor (BUFFER1)
5 - DHW tank
6 - DHW recirculation (P3)
7 - DHW tank pump (P2)
8 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
1 4 8 5
7
2
M
3
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp.: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
5
bar
1 4 8 10 6
M 9
2
M
3
1 - Boiler + Cm Pelet-set
2 - Accumulation tank
3 - 4-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - Accumulation tank upper temp. sensor (BUFFER1)
5 - Accumulation tank lower temp. sensor (BUFFER2)
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C )
bar
M
1 2
3 5
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C )
Tbuf min.: 20°C (5-85°C)
bar
4 6
M
1 2 7
M
3 5
1 - Boiler + Cm Pelet-set
2 - Accumulation tank
3 - 4-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - Accumulation tank upper temp. sensor (BUFFER1)
5 - Accumulation tank lower temp. sensor (BUFFER2)
6 - DHW tank
7 - DHW tank pump (P2)
8 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C )
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
8
M
1 2 6
7
3 5
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C )
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
dTbuf min.: 20°C (5-85°C)
bar
4 6
10
M
1 2 8 7
M 9
3 5
1 - Boiler + Cm Pelet-set
2 - Accumulation tank
3 - 4-way mixing + with actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - Accumulation tank upper temp. sensor (BUFFER1)
5 - Accumulation tank lower temp. sensor (BUFFER2)
6 - DHW tank
7 - DHW recirculation (P3)
8 - DHW tank pump (P2)
9 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C )
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
7
4
M
1 2 9 6
8
3 5
Temperatures:
Boiler temp.: 80°C (80-90°C)
Tpuf: 80°C (65-80°C)
dTpuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C )
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
Tbuf min.: 20°C (5-85°C)
bar
8
4 6
M
1 2 9 11 7
M 10
3 5
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 4-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
Temperatures:
Boiler temp.: 80°C (70-90°C)
bar
M
1
3
2
Temperatures:
Boiler temp.: 80°C (70-90°C)
bar
M
1 5
M
3
2
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 4-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - DHW tank
5 - DHW tank pump (P2)
6 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
6
M
1 4
5
3
2
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
4
bar
8 5
M
1 6
M 7
3
2
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 4-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - DHW tank
5 - DHW recirculation (P3)
6 - DHW tank pump (P2)
7 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
M
1 7 4
6
3
2
Temperatures:
Boiler temp.: 80°C (70-90°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
4
bar
M
1 7 9 5
M 8
3
2
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 4-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - CRO temp. sensor (BUFFER1)
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp: 75°C (65-80°C)
bar
4
M
1
3
2
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp: 75°C (65-80°C)
bar
5
4
M
1 6
M
3
2
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 4-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - CRO temp. sensor (BUFFER1)
5 - DHW tank
6 - DHW tank pump (P2)
7 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
4
7
M
1 5
6
3
2
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
5
bar
4
9
M
1 7 6
M 8
3
2
1 - Boiler + Cm Pelet-set
2 - Hydraulic crossover (CRO)
3 - 4-way mixing valve + actuator (MVAL2) + return flow temp. sensor (CIRCUIT2) + pump (P1)
(return flow protection)
4 - CRO temp. sensor (BUFFER1)
5 - DHW tank
6 - DHW recirculation (P3)
7 - DHW tank pump (P2)
8 - DHW tank sensor (DHW)
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
bar
4
M
1 8 5
7
3
2
Temperatures:
Boiler temp.: 80°C (70-90°C)
CRO temp: 75°C (65-80°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (3-20°C)
5
bar
7
4
M
1 8 10 6
M 9
3
2
Wifi AP - this option is used to enter the name of the WiFi network you
want to connect
WiFi key - this option is used to enter password of the WiFi network
you want to connect
1 Time sync. - this option is used to syncronise time betwen web portal
and boiler
Time zone - this option is used to set the time zone if boiler time zone is
different from web portal time zone
1 1
Regulation is connected Regulation is not connected
with web portal with web portal
(internet supervision is enabled) (internet supervision is not enabled)
IMPORTANT NOTES
CM WiFi-box requires active DHCP server of Access Point (e.g. router)
because manual setting of network parameters is not possible. For more
informations contact administrator of your home network
PELET SE T
OUTPUTS SAFETY
THERMOSTAT
ELECTRIC SCHEME 1/5
DOOR
M V A L1 M V A L2 PUMPS1 PUMPS2 SCREW BURNER1 POW1
SWITCH
N CL OP N CL OP P1 N P2 N P3 N P4 N P5 N SC N H N SC F N L1 S W S W
L
N POWER SUPPY
230 V
PE
4 P O LE
4 P BLACK
BLACK L1 L2 N MALE
MALE
L N PE L N PE L N PE L N PE
CONNECTION
OUTPUT OUTPUT OUTPUT OUTPUT TO THE
P 2 P 3 P 4 P 5 PELLET BURNER
PUMP TR A NSPOR TER
1
53
54
B A G 12V BUS BUS
RJ45 RJ45
BUS
K EY
CMSR50
PRESS.
PELET SE T - INPUTS PHO TO.
E X T1
12V 01 0 2
TEMP1 TEMP 2 TEMP3 COR1 COR2 RPM
BURNER2
+5V
ELECTRIC SCHEME 3/5
GND
GND
GND
POS.
POS.
DHW
5 V IN
T EMP.
T EMP.
BOILER
SP ARE1
SP ARE2
BUFFER1
CIRCUIT1
OUT SIDE
BUFFER2
CIRCUIT 2
EXT2
G
S G S G S G S G S G S G S G S G S G 1 2 3 1 2 3
6 P O LE 6 P BLACK
L1 N L1 N MALE
1 2 3 1 2 3 BLACK
MALE
SK SK
CONNECTION
TO THE
BURNER
SENSOR SENSOR SENSOR SENSOR SENSOR SENSOR OUTSIDE ROOM ROOM
P T 10 0 0 P T 10 0 0 P T 10 0 0 P T 10 0 0 P T 10 0 0 P T 10 0 0 SENSOR CORRECTOR CORRECTOR
P T 10 0 0
TFT DIS
UTP1 USB1
55
56
Electric scheme
6 P O LE L1 N L1 N 6 P BLACK
FEMALE
BLACK
FEMALE
ELECTRIC SCHEME 5/5
4 P O LE
BLACK L1 L2 N 4 P BLACK
FEMALE
FEMALE
3 P O LE 3 P GREEN
MALE
L1 N
GREEN
MALE
3 P O LE L1 N 3 P GREEN
FEMALE
FILING AND GREEN
TEMPERATURE FEMALE
SENSOR
2
FILLING AND
TEMPERATURE
SENSOR
3
1 3 2 1
+5V S IG G ND
PHOTOCELL
brown
brown
green
white
NOTES
30%
80°C
1700 60°C
70°C
15k 55°C
0% 50°C