Вы находитесь на странице: 1из 40

MA 2000 Series : Mixer Amplifier PA System

MA 2006, MA 2015 & MA 2025


Technical Features:
 60W (MA 2006), 150W (MA 2015) & 250W (MA 2025)
 4 Microphone & 2 Auxiliary Inputs (Unbalanced)
 REC Out
 Bass & Treble Control
 Master Volume
 Over Current & Short Circuit Protection
 No Zones Selection
MA 2000 Series : Mixer Amplifier PA System
MA 2415 & MA 2425
Technical Features:
 150W (MA 2415) & 250W (MA 2425)
 4 Microphone & 3 Auxiliary Inputs (Unbalanced)
 REC Out
 Bass & Treble Control
 Master Volume
 Over Current & Short Circuit Protection
 4-Zones Selection with Remote Mic
MA 2000 Series
Compatible Equipments:
 MC 1, MC 2, MC 3, MP 1, MP 2
 MH 1A, MH 2A
 PB 1000 Series Power Amplifier
 LS 12A
 RM 04 for MA 2415 & MA 2425 Only.
MA 2000 Series
Application:

 Temples & Mosque


 F&B Outlets
 Health & Fitness Clubs
 Retail Outlets
 Personal Care Salons
 Small Offices
 Any others of a Basic PA System
MEDUSA 3 : Integrated PA System
MED 306M & MED 312M
Technical Features:
 600W (MED 306M) & 1200W (MED 312M)
 Emergency Mic, Remote Mic, Line 1 & 3 Auxiliary Inputs (Balanced)
 REC Out
 Remote Mic , Line 1, AUX & Master Volume
 Built-In Automatic Amplifier Changeover
 Built-In 12 Zones
 Built-In Siren Tone
 Over Current & Short Circuit Protection
 Support 8 nos. Remote Mic
MED 306S
Technical Features:
 600W (MED 306S)
 Additional 12 Zones Extended from Master Unit
 Over Current & Short Circuit Protection
MEI 60
Technical Features:
 N+1, N, N-1 Sandwich Evacuation
 All Call Evacuation
 Built-In Internal Storage for Messages
 60 nos. Dry Contact Inputs
MEDUSA 3 Series
Compatible Equipments:
 MC 2, MC 3 & MP 2
 MRM 06 & MRE 12
 PB 1060 & PB 1120 Power Amplifier
MEDUSA 3 Series
Application:
 Medium scale Office Buildings / Government
Building
 Medium Scale Factory
 Supermarket
 Small to Medium Scale Hotel
MEDUSA 3 Series
System Limitation:
 Limited Zone and amplification capability
- in the market compact solutions usually limited by
zone and power.
- Maximum zones (12 - 24 zones)
- Power amplifier 600W to 1800W
MEDUSA 4 : Integrated Signal Manager
MED 400P
Technical Features:
 Emergency Mic, Remote Mic, Line 1 & 3 Auxiliary Inputs (Balanced)
 REC Out
 Built-In 12 Zones
 Built-In Siren Tone
 Remote Mic , Line 1, AUX & Master Volume
 Over Current & Short Circuit Protection
 Support 8 nos. Remote Mic
MEDUSA 4 Series
Compatible Equipments:
 MC 2, MC 3 & MP 2
 MRM 06 & MRE 12
 PB 1000 Series Power Amplifier
 MEI 60
 AC 04S & AC 08S
 LS 12A
 AM 10S
 LM 08
MEDUSA 4
Application:
 Universities
 Office Buildings / Government Building
 Large Scale Factory
 Supermarket / Shopping Mall
 Public Transport Stations
 Sports Complexes
 Museums
MEDUSA 4
System Limitation:

 Limited digital programming functions


 Limited simultaneous output
 Limited Zone and amplification capability
- in the market compact solutions usually limited by
zone and power.
- AEX System’s maximum 60 zones
MEDUSA 5 : Emergency Voice Alarm Control
System (Digital)
MEDUSA 52 / MEDUSA 54
Technical Features:
 MEDUSA 52 (240W) & MEDUSA 54 (480W)
 Emergency Mic, Remote Mic, Line 1 & 3 Auxiliary Inputs (Balanced)
 REC Out
 Built-In 6 Zones, Siren Tone & Digital Message Player
 Built-In Automatic Amplifier Changeover
 Over Current & Short Circuit Protection
 Support 8 nos. Remote Mic
 Time Scheduler
 6 nos. Dry Contact Inputs
MAR 12 & MAR 24
Technical Features:
 MAR 12 (12 Zones) & MAR 24 (24 Zones)
 2 Paging & 2 BGM Power Amplifier Inputs
 Built-In Automatic Amplifier Changeover
 Over Current & Short Circuit Protection
MAI 60 & MAI 60EM
Technical Features:
 MAI 60 Built-In with 15 nos. Dry Contact Inputs
 MAI 60EM Provide Additional 15 nos. Dry Contact Inputs
MEDUSA 5 Series
Compatible Equipments:
 MC 2, MC 3 & MP 2
 MRM 06 & MRE 12
 PB 1000 Series Power Amplifier
 AM 10S
 LM 08
MEDUSA 5 Series
System Features:
 Simultaneous Paging & Broadcast
- 2 Simultaneous output
 Capable of Automated (N+1), (N-1) Voice Evacuation
 System Surveillance & Self Diagnosis
- Constant & uninterrupted surveillance audio path from mic. to the
last speakers
- Self diagnosis check and report
 Windows Based GUI
- For configuration
MEDUSA 5 Series
System Features (Cont’):
 Automated Operation with Time Scheduler
- for digital message playback
 Supports up to 126 Zones
 Local Area Network (LAN) Connectivity Technology
- Able to Remote configure and monitoring
- Automatic send emails report while system faulty
MEDUSA 5 Series
Application:
 Shopping Malls
 Exhibitions / Convention Centers
 Office towers / Government Offices
 Hotels / Resorts
 Theme Parks
 Multi Campus Universities
 Public Transport Stations
 Sports Complexes
VEB Series: TCP/IP Network Matrix PA System
VEB 12-IPC
Technical Features:
 Served as Network System Manager
 Event & Announcement Logging
 Digital Message Player
 3 Channels of Audio Streaming through LAN
VEB 404
Technical Features:
 4 Channels 0dB (Stereo) AUX Inputs
 4 nos. Dry Contact Input for Input Activation
 Can be remotely controlled by VEB 12-IPC via LAN
VEB 601
Technical Features:
 Single Channel 0dB (600 Ohm, Balanced) Audio Outputs
 1 no. Dry Contact Output for ATT OVR
 1 no. Dry Control Output (User Programmable)
 Can be remotely controlled by VEB 12-IPC via LAN
VEB 604 / VEB 608 / VEB 616
Technical Features:
 Multi Channels 0dB (600 Ohm, Balanced) Audio Outputs
 Multi Dry Contact Output for ATT OVR
 Multi Dry Control Output (User Programmable)
 Can be remotely controlled by VEB 12-IPC via LAN
VEB 31
Technical Features:
 60 nos. Opto-Coupler Control Inputs
 Can be Programmed for Fire Alarm Automated Evacuation
VEB 32
Technical Features:
 60 nos. Opto-Coupler Control Output
 Can be Programmed to Trigger External Relays or Devices
VAC 04 & VAC 08
Technical Features:
 VAC 04 – 4 Channels Duty + 1 Channel Standby
 VAC 08 – 8 Channels Duty + 1 Channel Standby
 Automatic Changeover to Standby Amplifier when Duty Amplifier
Faulty
 Upon Fault Detection, Unit will report faulty status to VEB 12-IPC
VLS 12
Technical Features:
 12 Outputs selection per Unit
 Multiple units can be cascaded.
 Max current handling is 1200W per output.
 Can be remotely controlled by VEB 12-IPC via LAN
VEB 42 & VEB 42-EM
Technical Features:
 24 Outputs selection per Unit
 Multiple units can be cascaded.
 Included Emergency Microphone in VEB 42
 Primary communication through LAN
 If LAN failure, system will revert to analogue failsafe mode
VEB 43-10
Technical Features:
 9.7 inch display
 Capacitive Touchscreen
 Non-Condenser Gooseneck Microphone
 Zone selection & control via GUI
 Network Connection through LAN
 WIFI connection (Optional)
VEB Series
Compatible Equipments:
 MC 2, MC 3 & MP 2
 PB 1000 Series Power Amplifier
 AC 04S & AC 08S
 LS 12A
 AM 10S
 LM 08
VEB Series
System Features:
 Supports distributed system via the LAN
 Cost saving on 100V Line (1.5mm / 2.5mm Cabling)
 Supports LAN Based Network Paging Consoles
 Supports LAN Based PC Paging
 Automated Operation with Time Scheduler
 Supports up to 128 Audio Output Channels
 Supports Network Matrix Expander for subzoning
VEB Series
Application:
 Mixed Development (Shopping Mall, Hotel, Office)
 Intelligent High Rise Buildings
 Exhibitions / Convention Centers
 Hotels / Resorts
 Theme Parks
 Multi Campus Universities
 Public Transport Stations
 Sports Complexes

Вам также может понравиться