DSEGenset

DSE7520
ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITY
BS EN 61000-6-2

AUTO MAINS FAILURE EMC Generic Immunity Standard for


the Industrial Environment

& INSTRUMENTATION CONTROL MODULE


BS EN 61000-6-4
EMC Generic Emission Standard for
the Industrial Environment
FEATURES ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment

The DSE7520 is an Auto Mains A sophisticated module monitoring The modules can be easily TEMPERATURE
(Utility) Failure Control Module an extensive number of engine configured using the DSE7500 PC BS EN 60068-2-1
o
Ab/Ae Cold Test -30 C
suitable for paralleling single gen- parameters, the DSE7520 will software. Selected front panel BS EN 60068-2-2
sets (diesel or gas) with the mains annunciate warnings, shutdown editing is also available. Bb/Be Dry Heat +70 oC
(utility) supply. The module will and engine status information on VIBRATION
automatically start the generator on the back-lit LCD screen, illuminated BS EN 60068-2-6
detection of a mains failure, and will LED, remote PC, audible alarm and Ten sweeps in each of three
major axes
control the switchover from and via SMS text alerts. The module 5 Hz to 8 Hz @ +/-7.5 mm,
back to the mains (utility) supply, includes RS232 and RS485 ports 8 Hz to 500 Hz @ 2 gn
offering an uninterrupted return. as well as dedicated terminals for HUMIDITY
system expansion. BS EN 60068-2-30
The modules synchronising Db Damp Heat Cyclic 20/55 oC
@ 95% RH 48 Hours
functions include automatic The DSE7520 is compatible with BS EN 60068-2-78
synchronising with built-in electronic (CAN) and non-electronic Cab Damp Heat Static 40 oC
@ 93% RH 48 Hours
synchroscope and closing onto (magnetic pick-up/alternator
dead bus. Direct and flexible sensing) engines and offers a SHOCK
outputs from the module are comprehensive number of flexible BS EN 60068-2-27
Three shocks in each of three major axes
provided to allow connection to the inputs, outputs and extensive 15 gn in 11 mS
most commonly used speed engine protections so the system
DEGREES OF PROTECTION
governors and automatic voltage can be easily adapted to meet the PROVIDED BY ENCLOSURES
regulators (AVRs). most demanding industry BS EN 60529
IP65 - Front of module when installed into the
paralleling requirements. control panel with the supplied sealing gasket.

COMPREHENSIVE FEATURE LIST FOR SINGLE


GEN-SET PARALLELING WITH MAINS (UTILITY)
MODEM PC PC
DSE130
DSE157
9 3 3

232 485

DSE RS232 AND P810 CONFIGURABLE DC OUTPUTS ANALOGUE EMERGENCY DC POWER


EXPANSION RS485 INPUTS SENDERS STOP SUPPLY 8-35V

DSE7520
DEUTZ
ISUZU
PERKINS
CATERPILLAR
MTU
7 VOLVO
CUMMINS
OTHER SCANIA

MAINS (UTILITY) SENSING N/C VOLT FREE N/O VOLT GENERATOR SENSING CHARGE FUEL & CRANK ELECTRONIC
OUTPUT FREE OUTPUT ALTERNATOR OUTPUTS ENGINES &
MAGNETIC PICK-UP
VOLTS CURRENT CURRENT VOLTS
D+
W/L +

1ph 1ph 1 1 1ph 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N E N
N

ISSUE 6
®

DSEGenset

DSE7520
SPECIFICATION

DC SUPPLY
CONTINUOUS VOLTAGE RATING

AUTO MAINS FAILURE 8 V to 35 V Continuous

& INSTRUMENTATION CONTROL MODULE CRANKING DROPOUTS


Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout
FEATURES and supply recovers to 5 V. This is achieved
without the need for internal batteries

MAXIMUM OPERATING CURRENT


460 mA at 12 V, 245 mA at 24 V

MAXIMUM STANDBY CURRENT


375 mA at 12 V, 200 mA at 24 V

CHARGE FAIL/EXCITATION RANGE


0 V to 35 V
Fixed power source 2.5 W

OUTPUTS
OUTPUT A (FUEL)
15 A DC at supply voltage

OUTPUT B (START)
15 A DC at supply voltage

OUTPUTS C & D
8 A 250 V (Volt free)

AUXILIARY OUTPUTS E,F,G


2 A DC at supply voltage

GENERATOR
VOLTAGE RANGE
15 V - 333 V AC (L-N)
KEY LOAD SHARE FEATURES • Voltage measurement KEY BENEFITS
FREQUENCY RANGE
• No-break return • 9 Configurable inputs • Sends SMS messages to 3.5 Hz to 75 Hz
• Peak shaving/peak lopping • 5 Configurable outputs engineers to notify specific
• kW on mains (utility) level • Automatic start/Manual start engine problems (GSM Modem MAINS (UTILITY)
VOLTAGE RANGE
• Mains (utility) decoupling test • Audible alarm and SIM card required) 15 V - 333 V AC (L-N)
mode • LED indicators • On-site and remote module
• Manual speed/frequency adjust • Built-in governor and AVR configuration (Modem required) FREQUENCY RANGE
3.5 Hz to 75 Hz
• ROCOF & vector shift control for easy operation and • In-built engine diagnostics
• Dead bus sensing panel engineering removes the requirement for ALTERNATOR
• Direct governor & AVR control • Event log (25) service equipment VOLTAGE RANGE
15 V - 333 V (L-N) 50 Hz - 60 Hz
• Volts & frequency matching • Fault condition notification to a • Full engine protection & (Minimum 15 V AC Ph-N)
• kW and kV Ar load sharing designated PC instrumentation without the
• Manual voltage adjust • PC configuration need for additional senders FREQUENCY RANGE
Up to 75 Hz
• Mains (utility) failure detection (Electronic engines only)
KEY FEATURES • Configurable alarms and • Remote monitoring of the MAGNETIC PICK UP
• Compatible with CAN and start/stop timers module using comprehensive VOLTAGE RANGE
+/- 0.5 V to 70 V
magnetic pick-up • Automatic load transfer with DSE7500 PC software
• RS232 or RS485 remote no-break return • License-free PC software FREQUENCY RANGE
communications • SMS alert messaging (GSM 10,000 Hz (max)
• Modbus RTU modem required) BUILT-IN GOVERNOR AND AVR CONTROL
• PIN protected front panel • Remote control and monitoring Fully Isolated
editing • Dedicated load test button Minimum Load Impedance:
1000Ω
• Exercise engine scheduler • kW overload protection Gain Volts: 0 V-10 V DC
• Back-lit LCD 4-line text display • Engine temperature protection Offset Volts: + / - 10 V DC
• Multiple language options • MV-LV synchronising
DIMENSIONS
OVERALL
240 mm x 172 mm x 57 mm
RELATED MATERIALS 9.4” x 6.8” x 2.2”

TITLE PART NO’S PANEL CUTOUT


DSE7520 Installation Instructions 053-053 220 mm x 160 mm
DSE7500 Quick Start Guide 057-100 8.7” x 6.3”
DSE7520 Operator Manual 057-089 MAXIMUM PANEL THICKNESS
Load Share Design and Commissioning 057-047 8 mm
Guide to Synchronising and Load Sharing 057-045/6 0.3”
DSE7500 Configuration Suite PC Manual 057-078
CAN and DSE Wiring Guide 057-004

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-066/01/16 (7)
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457