Академический Документы
Профессиональный Документы
Культура Документы
FE AT U RE S
Ship speed measurement is insensible to bubbles generated in high-speed navigation, ensuring
stable speed display.
The transducer is substantially downsized, allowing it to be installed on the bow side that is
little affected by bubbles.
An underwater-mateable connector is adopted for the transducer, so that a transducer can be
replaced at a quay even in case of its failure.
The equipment is provided with an additional function of indicating the ship’ s fore and aft
speeds and port and starboard speeds by entering GPS information.
The ship’ s port and starboard speeds at its arbitrary position can be indicated by entering
ROT information.
An optimal Doppler sonar system can be configured by combining a variety of options.
On-line maintenance (option) allows any failure to be detected during navigation.
SPECIFICATIONS
Operating 2-axis 4-beam pulse Doppler sonar or
system ROT-combined 3-axis 4-beam pulse Doppler sonar (ROT: option)
Depth range B T : 2 to 250m (below hull bottom) depending upon sea bottom conditions
WT: 3m or more (below hull bottom)
Speed measuring accuracy ±1% or ±0.
1 kts whichever is greater
Total distance run accuracy ±1% or ±0.
1 nm whichever is greater
Ship speed indication XX.XX 4-digit indicator (in kts or m/s) (P/S: 3-digit)
Analog indication (in kts)
IEC61162-1 inputs ROT (Stern P/S speed) ROT (excl. GPROT)
(NMEA0183) GPS (GPS ship speed) GGA, RMC, RMA, GLL, VTG
GYRO (GPS ship speed) HDT, HDG
Data outputs IEC61162-1: 2000 outputs: 5 circuits VBW, VLW, DPT, DBT
DC voltage output: 2 circuits (for analog indicator)
Opto coupler signal: 8 circuits (200 pulses/nm)
Relay closure signal: 1 circuit (200 pulses/nm)
Relay closure signal: 1 circuit (Power fail alarm)
Power supply 100/110/115/220/230VAC
±10%、
50/60Hz, single-phase
Power consumption 300VA or less
2ch. Max
GPS
Gyro
Echo Sounder
Signal R.O.T Wind
(YARD) or 250V−TTYCS−1 (YARD MAX. 100m)
Processor Signal IEC61162-1:2000 .1
(OPTION)
NJC-24 Distributor IEC61162-1:2000 .2
IEC61162-1:2000 .3
250V−TTYC−4S (YARD MAX. 100m) NQA-3012 IEC61162-1:2000 .4
250V−TTYC−7S (YARD MAX. 100m) IEC61162-1:2000 .5
250V−TTYC−4S (YARD MAX. 100m) 250V-TTYCS-1
200 Pulse .1
200 Pulse .2 or
250V−TTYC−7S (YARD MAX. 500m) 200 Pulse .3 250V-DPYCS-1
200 Pulse .4 (YARD MAX.100m)
200 Pulse .5
Extension Cable ( JRC MAX. 40m) 200 Pulse .6
200 Pulse .7
Ship's Main 0.6/1kV DPYC−1.5 (YARD) 200 Pulse .8
Transducer 100/110/115/220/230 VAC
NKF-770 50/60Hz 1 PHASE On line maintenance
Alarm
24 VDC 0.6/1kV DPYC−1.5 (YARD)
(for Alarm)
CONNECTION DIAGRAM
STANDARD COMPONENTS
Description Model Quantity Remarks
Main Display NWW-60DB 1 DB: 2-axis flush mount type (standard)
DA: 2-axis wall mount type
T B: 3-axis flush mount type
T A: 3-axis wall mount type
Signal Distributor NQA-3012 1
Signal Processor NJC-24 1 IP55
Transducer NKF-770 1 With underwater-mateable connector and max. 40m cable
Spare Parts 7ZXBS0018 1
Instruction Manual 7ZPBS2802 1 English
OPTIONS
Component Model Quantity Remarks
Wing Display NWW-61D 2 D: 2-axis, IP56
T : 3-axis
Remote Display NWW-24 Analog Flush-mount type
Remote Display NWW-25 2 max. Analog wall mount type
Remote Display NWW-26 Analog Flush-mount type
Distance Counter NWW-7B 1 Flush-mount type
Gyro Sensor NJZ-1080 1 ROT
Operator Unit NWZ-120GA 1 ROT, GA: Wall-mount type GB: Flush-mount type
Rectifier NBA-3263 1 ROT
Dimmer Unit NCM-227 1 For NWW-60 Main Display Unit
Dimmer Unit NCM-329H 1 For NWW-24/25/26 Remote Display Unit
Transducer NKF-770W 1 Inner demountable type
Transducer NKF-772 1 Gate valve type
DIMENSIONS & WEIGHT
Main Display Unit NWW-60DA NWW-60DB NWW-60TA NWW-60TB
Unit : mm
384
320
384
320
220 74.8 220 74.8
219 95 219 95
520
604
210
357 480 160
292
225 225
7
φ25
922
532
φ375
φ315
355
● Specifications may be subject to change without notice. For further information, contact: