Features
• ±0.10% Accuracy
• Non-interactive
Calibration
• Transient, Over-current
and Reverse Polarity
Protection
• RFI Immune
P290M shown with optional
Din Rail Adapter and Din Rail
User-friendly, compact and versatile
P200 / P290 pneumatic-to-electric transducers
S P E C I F I C A T I O N S
3.125 1 (25.40)
(79.38)*
P290 with optional C type Din Rail .70
Adapter
.53 (17.78)
.5
(12.70) (13.46)
.3125 4.125
(7.94) 4.75 (104.78)
(120.65)
3.43
Holes for 3.00 (87.12
Spanner Wrench (76.20)
.25 (6.35) DIA. x 2 (50.80) Centers
1.99
(50.62)
Pressure
Inlet
1/4" NPT
5.37
(136.27)
5.79
3.625 (147.16)
(92.08)
Conduit
Entry
1/2" NPT P290 with optional G type Din Rail Adapter
.125 (3.18)
5.96
(151.39)
Principles of Operation
Pneumatic Input I
+
Reference Pneumatic - +
Transducer Precision Output In-process
and Zero Excitation Input Current
Bias Solid State Amplifier Current
Circuit Source Monitoring
Supply Transducer
Terminals
2.9375 -
(74.61)
A precision voltage reference circuit supplies a stable and
4.69 highly regulated voltage to all other portions of the circuit. An
(119.13)
excitation circuit drives the solid state, piezo-resistive transducer
which has the configuration of a Wheatstone Bridge. Upon the
application of pressure to the transducer, a force and resultant
strain causes the bridge to become unbalanced in direct
proportion to the applied pressure. The voltage thus obtained is
amplified, scaled, and summed with another reference voltage
to produce the output current source signal.
P200 / P290 Ordering Information
Warranty
ControlAir, Inc. products are warranted to be free from
OPTIONS defects in materials and workmanship for a period of
P200 P290
eighteen months from the date of sale, provided said
P/N Description P/N Description
products are used according to ControlAir, Inc.
P21 Lightening Surge Protector P31 CSA general recommended usages. ControlAir, Inc.’s liability is limited to
purpose certification the repair, purchase price refund, or replacement in kind, at
P22 2” Pipe, “U”-Bolt Hardware ControlAir, Inc.’s sole option, of any products proved
P23 Extra 316 SS Tag defective. ControlAir, Inc. reserves the right to discontinue
manufacture of any products or change products materials,
P28 CSA Intrinsically Safe (4-20 mA only)
designs or specifications without notice. Note: ControlAir
P29 CSA Explosion-proof (4-20 mA only) does not assume responsibility for the selection, use, or
P30 FM Intrinsically Safe (4-20 mA only) maintenance of any product. Responsibility for the proper
P45 10-50 mA output (P200 only) selection, use, and maintenance of any ControlAir product
*Transmitters with P27 option are not FM or CSA approved, explosion-proof
remains solely with the purchaser and end user.