Академический Документы
Профессиональный Документы
Культура Документы
Features Assembly
Function
Connection
Release date 2009-07-23 10:04 Date of issue 2009-07-23 205654_ENG.xml
16
15
24 V DC (I),
14 24 V DC (II),
13
12 ERR
11
17 ... 32
10
9
HART
8
7
6
Output II
HART
5
4
+ 3
2
1
mA
- 16
24 V DC (I),
15
14
24 V DC (II),
13 ERR
12
11 1 ... 16
10 HART
9
8
7
6
5 Output II
4
3
2
1
Supply
Rated voltage 24 V DC , in consideration of rated voltage of used isolated barriers
Voltage drop 0.9 V , voltage drop across the series diode on the Termination Board must be considered
Ripple ≤ 10 %
Fusing 4 A , in each case for 16 modules
Power loss ≤ 500 mW , without module
Reverse polarity protection yes
Redundancy
Supply Redundancy available. The supply for the modules is decoupled, monitored and fused.
Indicators/settings
Display elements LEDs PWR ON (power supply)
- LED power supply I, green LED
- LED power supply II, green LED
Conformity
Electromagnetic compatibility NE 21
Protection degree IEC 60529
Ambient conditions
Ambient temperature -20 ... 60 °C (253 ... 333 K)
Storage temperature -40 ... 70 °C (233 ... 343 K)
Mechanical specifications
Protection degree IP20
Connection connection hazardous area (field side): cage clamp terminals, blue
connection safe area (process side): output I HIMA system connector, output II cage clamp terminals
Material housing: polycarbonate, 30 % fibre-glass reinforced
Mass approx. 1600 g
Dimensions 650 x 200 x 163 mm (25.57 x 7.9 x 6.42 in) , height including module assembly
Mounting DIN rail
General information
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity and instructions have
to be observed where applicable. For information see www.pepperl-fuchs.com.
Accessories
Designation optional accessories:
- Fault Indication Board HiATB01-FAULT-01
- HART Communication Board HiATB01-HART-2X16
- HART Multiplexer Master HiD Mux2700
- HART connection cable HiACA-...
- Label Carrier HiALC-...
- connection cable HiACA-UNI-SD37-SD37-0M2 for connection between Termination Board 1 and 2
Release date 2009-07-23 10:04 Date of issue 2009-07-23 205654_ENG.xml
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 2
Technical data HiDTB32-HIM-AX-AI3201-SP
Application
This set consists of two different Termination Boards. They are connected with a separate cable:
• Termination Board 1 for channels 1 ... 16: HiDTB16-HIM-AX-AI3201-1-SP
• Termination Board 2 for channels 17 ... 32: HiDTB16-HIM-AX-AI3201-2-SP
• Connection cable type HiACA-UNI-SD37-SD37-0M2 between Termination Board 1 and 2
Configuration
9 8 7 Hazardous area
6 5 4 (Zone 1)
3 2 1 Field device
Analog in Analog in Analog in Analog in
Safe area
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
1
2
3
4
5
6
7
8
“Z” “Z”
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 3
Technical data HiDTB32-HIM-AX-AI3201-SP
HiD2030
+ 1+ Ouput I
- 4 HIMA
HART
I
7- X-AI 3201
2+
Ouput II
+ 5
terminals 12, 15
- 6-
Zone 0, 1, 2
Div. 1, 2
Note:
• Communication for SMART transmitter is provided only on output channel 1.
• Minimum supply voltage available for field transmitters is 14.7 V at 20 mA.
• Safety parameters are now:
- Uo = 27.2 V
- Io = 93 mA
- Po = 640 mW
• See operating instuctions for other connection options and for more details.
Release date 2009-07-23 10:04 Date of issue 2009-07-23 205654_ENG.xml
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com 4