Function Diagram
© Siemens AG 2007
Function Diagram
Functional sequence in up to 3
independent tasks
Acquisition of
Periodical processing all process data
Structured text
Step sequences
© Siemens AG 2007
Page 2 Juli-07 Chapter_07 ACP-Parametrierung FUP.ppt by M. Nikodym Power Transmission and Distribution
Signals in Function Diagram
The implementation of control circuits calls for not only the function
diagram, but also for signals from the environment (status information,
measured values, commands, etc.)
To be able to use these signals in the function diagram there are two
possible ways how to process them.
© Siemens AG 2007
Page 3 Juli-07 Chapter_07 ACP-Parametrierung FUP.ppt by M. Nikodym Power Transmission and Distribution
Signals in Function Diagram
1. Periodical processing
To make use of a signal periodically, the parameter
“Use_CAEx_Plus” must be enabled in the 1703 ACP link.
use of CAEx
1703 ACP Plus “YES“ (i.e.,
link this data point is
used periodically
at the BSE 020
© Siemens AG 2007
Page 4 Juli-07 Chapter_07 ACP-Parametrierung FUP.ppt by M. Nikodym Power Transmission and Distribution
Signals in Function Diagram
2. Spontaneous processing
If a signal is needed as message in the function diagram, a CAEx Plus
link is to be created and activated type identification
destination system
CAEx Plus
message address
category needs to be
aligned with the data
type
CAEx Plus
link this parameter is to
be enabled only if
periodical signals are
to be sent onward
spontaneously
© Siemens AG 2007
Page 5 Juli-07 Chapter_07 ACP-Parametrierung FUP.ppt by M. Nikodym Power Transmission and Distribution
Signals in Function Diagram
If the necessary links have been parameterized in the images, one can
now generate the signal list for the function diagram.
© Siemens AG 2007
Page 6 Juli-07 Chapter_07 ACP-Parametrierung FUP.ppt by M. Nikodym Power Transmission and Distribution
Signals in Function Diagram
After launching CAEx Plus, the signal list will contain all signals whose
CAEx Plus link has been activated and/or that are used periodically.
status bits
S: spontaneous
GI: general-interrogated
NT: not topical
IV: invalid
© Siemens AG 2007
Page 7 Juli-07 Chapter_07 ACP-Parametrierung FUP.ppt by M. Nikodym Power Transmission and Distribution
Signals in Function Diagram
© Siemens AG 2007
Page 8 Juli-07 Chapter_07 ACP-Parametrierung FUP.ppt by M. Nikodym Power Transmission and Distribution
Signals in Function Diagram
© Siemens AG 2007
Page 9 Juli-07 Chapter_07 ACP-Parametrierung FUP.ppt by M. Nikodym Power Transmission and Distribution
Signals in Function Diagram
3. Code Generation
After the successful code generation, the function diagram can be
loaded into the destination system
© Siemens AG 2007
Page 10 Juli-07 Chapter_07 ACP-Parametrierung FUP.ppt by M. Nikodym Power Transmission and Distribution
Signals in Function Diagram
Task:
© Siemens AG 2007
Page 11 Juli-07 Chapter_07 ACP-Parametrierung FUP.ppt by M. Nikodym Power Transmission and Distribution