HAND OUTS COMPRESSION MEMBER

A W 250X73 IS TO SERVED AS A PIN-ENDED 12m. LONG COLUMN BRACED AT MID-HEIGHT WITH RESPECT TO ITS WEAK AXIS.
THE PROPORTIONAL LIMIT IS 235 MPa.

* DETERMINE THE SLENDERNESS RATIO WITH RESPECT TO X AND Y AXIS


* DETERMINE THE EULER'S CRITICAL BUCKLING STRESS
* DETERMINE THE ALLOWABLE AXIAL COMPRESSIVE LOAD USING A FACTOR OF SAFETY OF 2.50

PROPERTIES OF W 8X35

A = 9280 mm^2 rx = 110 mm


d = 253 mm ry = 64.7 mm
bf = 254 mm 6.00
tf = 14.2 mm
tw = 14.2 mm
Ix = 113 X 10^6 mm^4 12.00
Iy = 38.8 X 10^6 mm^4

6.00

A W 8X35 STEEL COLUMN HAS AN UNSUPPORTED LENGTH OF 6m. USING A 36 STEEL WITH Fy = 248 MPa AND Es = 200000
MPa. COMPUTE THE ALLOWABLE AXIAL LOAD THAT IT COULD SUPPORT USE NSCP CODE

* IF BOTH ENDS ARE FIXED


* IF BOTH ENDS ARE PINNED
* IF ONE END IS FIXED AND THE OTHER END IS PINNED

PROPERTIES OF W 8X35

A = 6645.15 mm^2 rx = 88.9 mm


d = 206.25 mm ry = 51.56 mm
bf = 203.89 mm
tf = 12.52 mm
tw = 8.00 mm
Ix = 52.45 X 10^6 mm^4
Iy = 17.69 X 10^6 mm^4