ESTIMASI
NO NAMA ALAT SPESIFIKASI JML
HARGA (RP)
ICP-OES
-The Total Plasma View, from Superior vertical torch based radial observation, combined with a
1. (Optical Emissions 1 3.000.000.000,00
light-rich, high performance optical System, allows the analyst to run all types of Samples.
Spectrometer) with CCD
-The full wavelength coverage, from 160 to 800 nm, emphasizes this flexibility: a
unique and proprietary ICP-based Spectral database (from S3-base:
Single-element Spectra, Spectroscopic data) leads to optimum Selectivity with
potential use of all ICP lines, and a Superior Semiquantitative
analysis offers a precise identification of the Samples
-Spacious Sample introduction area and convenient corrosion resistant
fold-down Sample tray enable the user to run any type of Samples with dedicated
Sample introduction Systems.
-Quick release and quick mount torch design in a large and user-friendly compartment, with no
adjustmentrequired, facilitates multi-user operation and provides excellent reproducibility.
-The Vertical Torch with Superior Total Plasma View provides optimum
Sensitivity, with reduced matrix effects, for both aqueous and organic matrices.
-The Sheath gas device, with a large 3 mm i.d. injector tube, gives unique
high dissolved Solids capability (up to 30% NaCl), with excellent long-term Stability,
and minimises memory effects.
ƒƒ-Smart Hood provides Safe, convenient extraction with reduced installation costs.
- Reliable high efficiency 40.68 MHz Solid State
generator enhances the ability to handle a wide variety
of applications and improves the limits of detection.
Warm-up time is also reduced (usually less than 15 minutes)
-The ICP Unit is equipped with an Open Electrode CCD
(Charge Coupled Device) detector with an image area of 26.6 mm x 6.7 mm
-The combination of ultra low noise and binning capability then provide
a practical dynamic range (Signal before saturation-to-readout noise ratio)
for each line of 10 7, with a linear response range of 5 decades minimum,
-Generator : Radio frequency, solid-state 40.68 MHz, Water Cooled
-Cooling systems : GenCo water chiller for the generator and the coil
-Exhaust : direct exhaust connection for plasma compartment
-Plasma Gas Requirements : 12 Liter / Minutes Argon
-Sheath Gas : 0.2 L/Min Argon
-Sample Introductions : Concentric glass nebulizer, cyclonic glass
spray chamber, 3 channels peristaltic pump
-Optical Systems : Thermo-regulated, 0.64 meter focal length,
dual back-to-back gratings, 4343 g/mm and 2400 g/mm used in the
1st order with optical resolution <12 pm for 160-430 nm and <22 pm
for 430-800 nm.
-Wavelength Ranges : 160 - 800 nm
-Detections : Open electrode CCD, 1024x256 pixels, pixel
size 26x26 μm, Peltier cooled
-Voltage : 230 Volts 50 Hz
Including :
1 sets Branded PC Computer and Printer, Intel Core I-5 Minimum, 500 GB
HDD Minimum, 4 GB DDR 3 Memory DVD RW, 19" Monitor, Desk Jet Printer
1 sets Refrigerated Circulating Chiller 1500 Watts
1 sets Standard Sample Introductions Systems
1 sets Smarthood Exhaust
1 roll Aluminium Flex Hose
1 Warranty card 2 Years for RF Generator
1 Diagnostics and Validations Software (QC-2000)
1 sets IQ / OQ documents
1 pcs Regulator Argon
4 pcs Cyinder Gas Argon UHP
1 pcs Online UPS APC or Equal Minimal 8000 VA
Mass Spectrometer :
Fast Acquisitions rates up to 30,000 spectra/seconds over the entire mass ranges
All spectra acquired are stored in a compressed format to provide a continuous full mass ranges
acquisitions rate up to 1000 Hz.
Detector type : Time of Flight MS
Mass Ranges : 5 - 1024 amu
Scan Rates : 30,000 spectra / seconds, up to 1000 Hz written to disk equivalent to
1,024,000 amu / seconds. Resolutions : 1500. Maximum Sensitivity : 1 pg OFN
S/N 150 : 1, extracting m/z 272 ion on raw data
Maximum Linearity : 10 5
Tune Mode : One Click AutoTune and Manual Tune
Ion Source : Inert EI Source
Maximum Source Temperature : 220 o C
Vaccum Systems : Internal diapraghm pump and Internal Turbo Molecular Pumps
260 L / Seconds and 70 L / Seconds
-Windows Software with PC computer and Printer (Intel Core I-5 Processor,
8 GB DDR3 memory, 1 TB Min HDD, DVD DROM, 19" Minimum LCD Monitor))
-Voltage : 220 Volts 50/60 Hz
-External Dimensions : 570 mm x 500 mm x 590 mm (W x H x D)
-Power Consumptions : 2800 Watts (For the GC)
Systems Consisting of :
1 pcs GC Main Unit
1 pcs Split/splitless Injector with Digital Flow Control (terpasang)
1 pcs ToF Plus MS Detector
1 pcs Autosampler with Racks for 160 samples
1 pcs Spare of Liners for Split / Splitless Injector atau PTV Injector
1 pak Spare of Septum pk/50
1 pak Nut M4 SS, pk/10
1 pak Ferrule VGR for Capilarry Column , pk/10
2 pak Nut F4 1/8" Brass pk/10
2 pak Ferrule 1/8" With Washer, pk/20
1 pcs Syriges Injections 10 UL
1 pcs Capilarry column DN-1 MS
1 pcs Capilarry column DN-5 MS
1 pcs Capilarry column DN-WAX MS
1 pcs Key 6-7 mm USAG 252NC
1 pcs Key 8-10 mm USAG 252NC
1 pcs Moisture Traps
1 pcs Oxygen Traps
3 pcs SS Tubings, pk/5 meter
1 pcs Regulator for Helium
1 pcs Helium Cylinder Gas UHP
1 pcs CD NIST Library
1 pcs Online UPS APC or equal ,Minimum 6000 VA
3. HPLC The SIL-20A Series autosamplers achieve unparalleled speed, with a sample injection movement of 1 2.500.000.000,00
(SHIMADZU – Prominence) just 10 seconds.
Prominence reduces the total analysis cycle time, not simply the time for the HPLC analysis itself.
The optional rack changer permits the serial analysis of up to 4,068 samples.
Prominence is an HPLC system that offers genuine high throughput.
Shimadzu offers a range of software environments to apply
Prominence to diverse fields from medicine, pharmaceuticals, and biochemistry to chemistry, the
environment, and food products.
PC control and data acquisition
Data acquisition by Chromatopac and PC
Central control of analytical instruments data
Record management and LIMS
Support for other vendors' software (multivendor compatibility)
4. Tanur Technical Data 1 70.000.000,00
ELF 11/14 - Max. Temperature (°C) : 1100
- Continuous Temperature(°C) 1000
- Chamber Dimensions : 210 x 220 x 310 (HxWxD) mm
- External Dimensions : 630 x 450 x 520 (HxWxD) mm
- Heat up time (mins) : 40
- Temperature uniformity : ±5°C
@1000°C
- in a uniform envelope of : 130 x 140 x 220 (HxWxD) mm
- Max. (W) : 2600
- Holding Power (W) : 1300
- Internal volume (l) 14
- Thermocouple Type : K
- Weight (kg) : 31