Вы находитесь на странице: 1из 1

Pt A, Ch 1, Sec 4

2.2.3 Piping calculations umn and floater, column and deck in column stabilized
The following design calculations are to be provided as sup- units), in way of foundations of jacking systems for self-
porting documents to the submitted plans and drawings: elevating units, drilling derrick, anchoring equipment,
crane foundations and of all other parts liable to be sub-
• piping and pressure vessels strength calculations, in par-
ject to high local loadings or stress concentrations
ticular for calculation of steam pipes and other pressure
piping • test plan of compartments intended for liquids
• fire water demand and fire pump capacity calculations. • arrangements and details of watertight doors and other
closing appliances; arrangement and details of all open-
2.2.4 Electrical calculations ings and means of closure including locations of over-
Electrical design calculations are to be provided as support- flow and air pipes
ing documents to the submitted plans and drawings, includ- • drawings showing corrosion control arrangements.
ing:
• electrical balance, estimated for the different conditions 2.3.3 Machinery and piping systems
of operation of unit (refer to Ch 1, Sec 1, [1.6.4]) The following machinery and piping drawings are to be
• justification of sizes of conductors (temperature rises submitted:
and voltage drops) a) General:
• for installations where the total rated current of genera- • general arrangement showing particularly location
tors arranged to run in parallel is above 1000 A, estima- of essential machinery and equipment
tion of the prospective short-circuit currents
• bilge and ballast pipings, outside and inside machin-
• where the main bus-bar maximum symmetrical short- ery spaces
circuit current is expected to exceed 50 kA, justification
of the bus-bar and bracket strength related to the • sea inlets, scuppers and discharges
induced electromagnetic forces. • air vents, overflow and sounding piping systems
and/or devices
2.2.5 Additional class notations • remote level indicating systems and draught meas-
Additional calculations as may be called for concerning the urements systems
assignment of additional class notations are to be also pro- • boiler feed system
vided.
• sea water distillation system
2.3 Plans and drawings • fuel oil and lubricating oil systems, including pip-
ings and tanks not forming part of the unit's structure
2.3.1 General drawings • live steam piping
The following general drawings are to be submitted: • reduced pressure steam, draining, and exhaust pip-
• general arrangement plan ing
• lines drawings (body plan) and offset table of frames, • machinery circulation and cooling piping
together with plotting of fore and aft axial longitudinal • compressed air systems for remote control, instru-
curves mentation, engine starting and bulk handling,
• capacity plan indicating the volumes, overflows and the including compressed air vessels and pipings
positions of the centres of gravity of the various com- • accessories such as heaters, coolers, waste heat
partments together with their locations recovery units, etc.
• tank sounding tables • exhaust ducts of engines and boilers
• distribution, actual or estimated, of the unit's light- • location and arrangement of drip-trays and gutter-
weight ways
• deck loading plans. • jacking systems, for self-elevating units
• propulsion and power generating systems.
2.3.2 Structural drawings
b) Thermal oil heating installation:
The following structural plans are to be submitted:
• piping and pumping systems
• main structural drawings showing structural arrange-
ments, scantlings, grades of steel, welded connections. • general arrangement of the installation
These drawings are to include, as applicable: transverse • boilers including their major components
and longitudinal sections, decks including helicopter
• protections against oil leakage
deck; shell plating and framing; bulkheads and flats;
legs; columns, bracings and floaters; hull, footings and • monitoring and alarm systems
mats; superstructures and deck houses • nature and characteristics of the thermal oil: viscos-
• detailed structural drawings in the areas of connections ity, flash point, fire point, decomposition tempera-
between main structural members (for instance, con- ture, auto-ignition temperature, etc.
nections between bracings, bracing and column, col- • operation and maintenance instructions.

38 Bureau Veritas - Rules for Offshore Units December 2016

Вам также может понравиться