FORM U-4 MANUFACTURER'S DATA REPORT SUPPLEMENTARY SHEET

As Required by the provisions of the ASME Boiler and Pressure Vessel Code Rules, Section VIII, Division 1

Mabel Engineers Private Limited


1) Manufactured and certified by Plot 66-69, EPIP, Sipcot Industrial Complex, Gummudipoondi Taluk, Thiruvallur District, Tamilnadu 601201, India.
(Name and address of Manufacturer)

2) Manufactured for Growel Technology and Development Service LLP


(Name and address of Purchaser)

3) Location of installation Not known


(Name and address)
4) Type Vertical Air Receiver MEPL-18-001
(Horizontal, vertical / Sphere) (Tank, Separator, heat exch., etc) (Manufacturer's Serial number)
-- MEPL-10-01-GA-01 Rev.1 -- 2018
(CRN) (Drawing number) (National Board number (Year built)

Data Report Remarks


Item Number
Form U-1A

Item No 12 Remarks

1.Post forming heat treatment ( Stress Releiving ) for dished ends was done as per the following details

a.Loading Temperature : 300º C

b.Heating Rate : 125º C/hr

c.Holding Temperature : 610º C ± 10

d.Soaking Time : 30 Minutes

e.Cooling Rate : 150º C/hr

2 Impact test exempted as per UG 20(f).

3 Inspection opening as per

Certificate of Authorization: Type ASME U No 48, 949 Expires January 16, 2018

Date Mar 00, 2018 Name Mabel Engineers Private Limited Signed WESLY SELVAKUMAR
(Manufacturer) (Representative)

Date Mar 00, 2018 Name DURAISAMY SUNDARESAN Commissions AI COMMISSION NO : 16272
(Authorized Inspector) (National Board Authorized Inspector commission number)