MKPL
Magnetic drive chemical process pump
MKPL-S
Self-priming magnetic drive chemical process pump
Designed to:
DIN EN ISO 2858, 5199 and 15783
Compliant with:
EC Directives 2006/42/EC (Machinery) and 94/9/EC (ATEX)
Open impeller of PFA lined magnetic drive pumps
2
CP Pump Systems
PFA Lined Magnetic Drive Centrifugal Pumps
The MKPL and MKPL-S pumps come with either an open im-
Energy efficiency in industry peller for low NPSH or a closed impeller for high efficiencies.
Nowadays, industry is facing increasing demands to improve Featuring a metal core for increased mechanical strength,
sustainability and energy efficiency. Pumps are considered their plastic impellers are firmly secured to prevent loosening
to play a key role because they offer vast potential to save in case of reverse pump rotation.
energy and costs. Already recognising this back in 1999,
CP took action and has become a pioneer in energy-saving Both pumps are constructed with just a few, robust com
pumping systems. ponents using an intelligent modular system that facilitates
assembly and minimises the costs of spare parts, maintenance
In recent years, we have continuously enhanced the hydraulic and servicing.
performance of numerous pump systems, increasing their
efficiency by up to 30 per cent. At the same time, we have
steadily improved pump safety, a mission we have vigorously
pursued ever since our company was established in 1948.
3
MKPL
PFA Lined Magnetic Drive Chemical Process Pump
50 Hz Rev. 05 22.09.10 Tf
data conform to DIN EN ISO 2858, making the MKPL easy Heads (min./max.) Q [m3/h]:
3 to 90 m
H [m]:
to retrofit into any installation to replace old pumps. Temperatures (min./max.) –20°C to +200°C
Kinematic viscosities 0.5 to 350 mm2/s
100 3000 min-1
Solids concentration up to 10% depending on fluid
80
Directives
EC Directive 2006/42/EC (Machinery)
50-40-250
80-50-250
100-80-250
60
EC Directive 94/9/EC (ATEX)
H [m]
50-32-200
65-40-200
80-50-200
100-65-160 100-80-200
40
Standards
50-32-160
65-40-160
80-50-160
25-25-160
DIN EN ISO 2858
MKPL
20
19 A 0 DIN EN ISO 5199
50 Hz Rev. 05 22.09.10 Tf
DIN EN ISO 15783
Q [m3/h]: H [m]: 0
1 MKPL 10 100
19 A 100
1000
Q [m3/h]
60 Hz Rev. 5 20.12.12 Am
80
100
30 3600 min-1
50-40-250
80-50-250
150-125-315
100-80-250
60
80
H [m]
H [m]
50-32-200
20
50-40-250
65-40-200
80-50-200
80-50-250
80-50-20050-32-200
100-65-160 100-80-200
65-40-200
100-80-250
80-50-200
40
100-80-200
50-32-200
65-40-200
60
100-65-160150-125-315
1000 min-1
100-80-200
50-32-160
65-40-160
80-50-160
H [m]
25-25-160
10
20
80-50-160
65-40-160
50-32-160
40
50-32-160
65-40-160
80-50-160
25-25-160
25-25-160
100-65-160
0
1 MKPL 10 100
19 A 100
1000
0
20 1 10 100 1000
Q [m3/h] Q [m3/h]
3000 rpm/50 Hz60 Hz Rev. 5 20.12.12 Am
1500 rpm/50 Hz
40 3
Q [m /h]: H [m]: 0
1500 min-1
1 10 100 1000
Q [m3/h]
100
30 603600 min-1
1800 min-1
150-125-315
50
80
H [m]
20
50-40-250
80-50-250
80-50-20050-32-200
65-40-200
40
100-80-250
80-50-200
150-125-315
100-80-200
50-32-200
65-40-200
60
100-65-160150-125-315
1000 min-1
100-80-200
H [m]
H [m]
10 30
50-40-250
80-50-250
100-80-250
80-50-160
65-40-160
50-32-160
50-32-160
65-40-160
80-50-160
40
25-25-160
25-25-160
100-65-160
50-32-200
65-40-200
20
80-50-200
150-125-315
100-80-200
1200 min-1
0
20 1 10 100 1000
Q [m3/h] 10
25-25-160
50-32-160
65-40-160
100-65-160
80-50-160
0 0
1 10 100 1000 1 10 100 1000
Q [m3/h] Q [m3/h]
3600 rpm/60 Hz 1800 rpm/60 Hz
60
1800 min-1
4
50
Close-coupled MKPL Frame-mounted MKPL
with baseplate with baseplate
–20°C to +200°C –20°C to +200°C
5
MKPL-S
PFA Lined Self-Priming Magnetic Drive
Chemical Process Pump
The MKPL-S features an integral priming chamber in the Technical data MKPL-S 22 A 0
casing. A separate priming tank is not necessary because the 50 Hz Rev. 0 20.12.05 TF
pump evacuates the suction line itself by creating a vacuum. Capacities (min./max.) 0.5 to 35 m3/h
Q [m3/h]: H [m]:
The MKPL-S can even readily pump entrained air in the suction Heads (min./max.) 3 to 40 m
line while running, thus increasing reliability of operation. Temperatures (min./max.) –20°C to +150°C
This pump achieves suction lifts up to 8.5 m.
Kinematic viscosities 0.5 to 350 mm2/s
50 3000 min-1
Solids concentration up to 10% depending on fluid
40
Directives
EC Directive 2006/42/EC (Machinery)
30
50-32-160
EC Directive 94/9/EC (ATEX)
H [m]
20
Standards
MKPL-S 22 A 0 DIN EN ISO 2858
10
50 Hz Rev. 0 20.12.05 TF DIN EN ISO 5199
Q [m3/h]: H [m]:
DIN EN ISO 15783
0
1
MKPL-S 10
22 A 100
100
60 Hz Q [m3/h] Rev. 0 20.12.05 TF
Q [m3/h]: H [m]:
50 12 3000 min-1 1500 min-1
10
40
70 3600 min-1
8
60
30
50-32-160
50-32-160
H [m]
H [m]
6
50
20
50-32-160
40
4
H [m]
10 30
2
MKPL-S
20
0 22 A 100 0
1 10 100 1 10 100
60 Hz Q [m3/h] Rev. 0 20.12.05 TF 10 Q [m3/h]
3000 rpm/50 Hz 1500 rpm/50 Hz
Q [m3/h]: H [m]:
-1
12 0 1500 min
1 10 100
Q [m3/h]
10
8
14
60
50-32-160
H [m]
6 12
50
10
50-32-160
50-32-160
40
4
H [m]
H [m]
30
2
6
20
0 4
1 10 100
10 Q [m3/h]
2
0 0
1 10 100 1 10 100
Q [m3/h] Q [m3/h]
3600 rpm/60 Hz 1800 rpm/60 Hz
16 1800 min-1
6 14
12
Close-coupled MKPL-S Frame-mounted MKPL-S
with baseplate with baseplate
–20°C to +150°C –20°C to +150°C
7
Applications
Versatile – Complex – Special
CP’s PFA lined magnetic drive pumps are engineered to meet Industries
the most stringent quality standards and ensure reliability
and utmost safety in production operations. Suitable for many – Chemical processing: basic and fine chemicals
(agrochemicals, speciality chemicals)
different fluids in a variety of industries and processes, they
– Pharmaceuticals
are capable of handling low, medium and high flow volumes.
– Biotechnology processing
PFA lined magnetic drive pumps from CP offer tremendous
advantages, especially in pumping sensitive or hazardous
substances. Processes
CP’s PFA lined magnetic drive pumps are designed for a wide range
of processes, including:
– Chlor-alkali electrolysis
– Sulphuric acid recycling
– Tank unloading
Fluids
CP’s PFA lined magnetic drive pumps can handle hot and/or highly
concentrated acids, alkalis (bases), solvents and diffusing fluids.
For example:
– Bromine
– Chlorine
– Nitric acid
– Phosgene
– Potassium hydroxide solution
– Sodium hydroxide solution
– Sulphuric acid
8
PFA lined metal plain bearing carrier
9
Options
Comprehensive – Individual – Combinable
Casing
Materials
– PFA lined cast iron
Pressure rating
– PN 16
Connection flanges
– Flange to EN 1092-2
– Flange drilled to ANSI/ASME B16.5
Additional connections
– Casing drain (with or without flange)
– External flush connection for bearing lubrication and/or cooling
the magnet assembly
– Lantern monitoring connection
Gasket materials
– PTFE
– PTFE/graphite
O-ring materials
– FEP/FKM
– Kalrez®/Chemraz®
Bearing assembly
Materials
– SSiC (sintered silicon carbide)
– SSiC with diamond-like coating (ADLC)
– SSiC with FuturaSafe® diamond coating
Containment shell
Materials
– Carbon fibre reinforced PTFE
– Heat-resistant carbon fibre reinforced PTFE
– Carbon fibre reinforced PVDF
Double-walled containment shell with leakage monitoring
10
Pump protection
Containment shell monitoring
Double-walled containment shell with leakage monitoring
Pt100 temperature probe
Motor load sensor
Mount
Type
– Baseplate
Materials
– Steel
– Stainless steel
Stilts
Drip pan
Bearing frame
Lubrication
– Oil lubrication
– Grease lubrication
Oil lubrication options
– Hermetic seal (MagTecta OMTM)
– Constant level oiler
– Oil cooling with or without thermostat
Coupling
Coupling guard
– Steel
– Brass
The options vary depending on the pump model. Our sales staff will be glad to advise you in detail.
11
Sectional View
MKPL
Bearing frame (–20°C to +200°C), horizontal
11 12
4
9
3
5
2 7 8
6
10
12
CP Pump Systems
Our Product Portfolio
13
Improving energy efficiency in pumping systems
helps to create a cleaner planet.
Your CP distributor
20140411_BRO_MKPL_MKPL-S_en 04019-03