Вы находитесь на странице: 1из 7

Heat Exchanger Inspection

The Heat Exchanger Inspection article provides you with information about the inspection of the
heat exchanger and heat exchanger testing during the manufacturing phase, as well as in-service
inspection in operating units. You may want to review shell and tube heat exchanger inspection
procedure and related inspection and test plan.

Shell and Tube Heat Exchanger Inspection in


Manufacturing Shop

The construction code for shell and tube heat exchangers is ASME Code Section VIII, and it
covers the minimum requirements for design, materials, fabrication, inspection, testing, and
preparation for initial delivery.

After the 2003 addenda of ASME Code Section VIII Div. 1, the design of the shell and tube heat
exchanger needs to be done based on Subsection C, in UHX part. The design based on TEMA,
or any similar code might be accepted which meeting the requirements of UHX part.

The heat exchanger still is a pressure vessel and all requirements for ASME pressure vessel does
apply for heat exchanger as well. We are going to avoid to repeat those requirements for the heat
exchanger. You may review pressure vessel inspection article for those requirements.

There are several inspection requirements that only apply to the heat exchanger and not regular
pressure vessel:

Tube Inspection - The tube outside diameter, inside diameter, thickness, and ovality shall be
checked before the building of the tube bundle. You need to refer to ASME Section II to get the
acceptance tolerances.

For example, if your tube material is SA 179, you have to refer to the SA 179 and that will refer
you to the SA 450 ( Specification for General Requirements for Carbon, Ferritic Alloy, and
Austenitic Alloy Steel Tubes) for acceptance tolerance. You have to use your caliper, machinist
ruler, etc. to make these measurements and make sure the values fall within acceptance range.
Tube Bundle Inspection - The bundle dimension shall be checked based on the approved
drawing. The baffle diameter and distance between them shall be controlled and meet the
acceptance tolerances in the drawing.

The tightness of stay bolts and spacers must be controlled. The shell cleanliness needs to be
verified and make sure the inside welds are complete and are ground as per drawing
requirements.

Tubesheet Inspection - The Tubesheet shall be inspected before welding to the shell. The hole
diameter, grooves dimensions, drilling pattern, the thickness of the tubesheet and surface finish
shall be measured and checked aginst acceptance tolerances in the approved drawing.

Tube Rolling Inspection - The tube rolling shall be checked based on customer specification.
The wall reduction (after rolling) and depth of roll shall be measured and shall meet the customer
specification. The wall reduction should not be less than 5% and should not be more than 8% of
the tube wall thickness.

Leak Testing of Seal Weld (Tube to Tubesheet) - if seal welding considered, then the leak test
will be a mandatory requirement. The shell side will be subjected to the air pressure, and water
and soap solution will be sprayed to the tubesheet to make sure all seal welds are defect free. The
bubble will be developed if there was any welding defect such as crack, pinhole, etc.

Shell side Hydrostatic Testing - After manufacturing completion, the heat exchange shell side
will be subjected to the hydrostatic testing. The test pressure amount shall be consistent with the
value indicated in the approved drawing. The holding time shall be based on the supplier
approved test procedure.

The pressure gages calibration and range shall be controlled. The pressure gage range shall be
within 1.5 thru 4 times of test pressure. The shell body and welding seams shall be inspected.
The tubesheet also shall be checked. No leakage is allowed.

The test pump hose shall be disconnected, and no pressure drop is allowed. The test result will be
satisfactory if no leakage being observed and no pressure being dropped while the shell side was
under pressure.

Tubeside Hydrostatic Testing - After successful completion of shell side hydrostatic testing,
the bonnets are assembled, and tube side is subjected to hydrostatic testing. Similarly, the
amount of test pressure shall be as the one indicated in the approved drawing. Other requirement
is similar to the shell test. No leakage and pressure drop shall be observed while the tube side is
under pressure.

Third Party Inspection for Shell and Tube Heat Exchanger article provides you a procedural
content for heat exchanger inspection. Review following standard Inspection and Test Plan for
Shell and Tube Heat Exchanger.

You might be interested in reviewing following related articles:


Heat Exchanger Theory

Fin Tube Heat Exchanger Inspection

Third Party Inspection for Fin Tube Heat Exchanger

Inspection and Test Plan for Fin Tube Heat Exchanger

Shell and Tube Heat Exchanger Application

Shell and Tube heat exchangers are the most popular type in the industry. This type is made from
3 components as listed below:

 Two heads (one rear head, and the other one stationary head)
 Shell
 Tube

One fluid is in the tube side and the other one in the shell side. The heat transfer is done through
the tube wall.

So your heat exchanger with more tubes will have more heat transfer surfaces, and at the same
time will have a higher heat exchanger diameter.

There are different kinds of shell and tube heat exchangers with different applications.The reason
for the high amount of applications is that they are easy to maintain.

Besides, the shell and tube heat exchanger is the only type that can be designed and operated at a
temperature greater than 360 degrees centigrade, as well as in pressure higher than 30 bar.

In-Service Inspection of Shell and Tube Heat Exchanger


The In-Service Inspection code for shell and tube heat exchangers is API STD 510. The other
API recommended practices and codes also have to be used in with this Code.

Some of these Recommended Practices are API RP 572, API RP 577, and API RP 571, and also
construction code sections might be used, such as ASME Code Section VIII and ASME Code
Section IX.

For repair, the requirement of API STD 510 or ASME-PCC-2 needs to be met. The title of
ASME-PCC-2, which was first published in 2006, is: “Repair of Pressure Equipment and
Piping.”

Please note: if your shell and tube heat exchanger is “U” stamped and you need to do the repair,
you have to use a Repair Organization holding an “R” Stamp from the National Board Inspection
Code.

The API 510 Pressure Vessel Inspectors are qualified persons to perform shell and tube heat
Exchanger inspection. You may also review the Industrial Plant Inspection article.

What are the Important Items in the Shell and Tube Heat
Exchanger Inspection in Overhaul?
Shell and Tube Heat Exchanger Inspections are categorized in the following way:

Shell and Structure in Heat Exchanger Inspection:


 Neutralization of Austenitic Stainless Steel shell, clads, liner or weld overlay, which
contains H2S service. The process needs to be done based on approved procedures by a
corrosion engineer.
 Neutralization is also required for shell material with admiralty brass to reduce the risk of
SCC.
 Neutralization of thermocouples, if necessary, and doing dye penetration test
 Sampling from shell fouling and corrosion products and making lab analysis and making
interpretation by corrosion engineer (if necessary)
 Cutting small area of insulation sheet and removing the insulation and doing visual
inspection for any sign of corrosion under insulation
 Thickness measurement of different parts of shell and shell nozzles and making corrosion
rate and remaining life calculation
 Inspection of shell cleaning and approval i.e. water jetting etc.
 Checking inside surface for any cladding, liner failure or separation
 Inspection of Shell flange gasket seating area for any erosion, damage and cracking
 Inspection of longitudinal and circumferential weld joints, inlet and outlet nozzles,
reinforcement pads and small bore connections for any crack, corrosion and mechanical
damage and deformation
 Dye penetration test on weld joints that are susceptible to cracking, austenitic flange face,
weld overlay and cladding surface and exchangers exposed to amine and caustic
 Hydrogen blistering inspection in hydrogen services (hand lamp procedure)
 Heat exchanger support, steel structure, foundation, bolt and nut inspection

Bonnet in Heat Exchanger Inspection

 Thickness measurement and making corrosion rate and remaining life calculation
 Girth flange inspection for corrosion and erosion
 Internal surface inspection for corrosion and fouling
 Painting inspection of external surface
 Dye penetration or magnetic particle examination of weld joints susceptible to cracking
Tube Bundle in Heat Exchanger Inspection

 Taking care in the pulling out of tube bundle to avoid any mechanical damage
 Sampling from tube side fouling and corrosion products and making lab analysis and
making interpretation by corrosion engineer (if necessary)
 Controlling of water jetting or lancing cleaning process
 Controlling wire brushing process of inner tube edge and rolling area (preparation for ID
measurement)
 Inside diameter measurement in tubes and tubes rolling areas
 Rate off and accordingly plugging the tubes when their OD reaches to the ID plus one
thickness
 Retubing of tube bundle if more than 10% of tubes reach the above rejection limit
 Inspection from tube bundle components such as tubesheet, tube, tie rods and spacers,
transfer baffles or support plate, impingement baffle, floating head flange and floating
head backing device
 Inspection from internal surface of tubes for corrosion and fouling
 Pulling out a sample tube for sectioning and corrosion anlaysis if necessary
 Retubing when sectioning result proves the thickness is half of the nominal value
 Visual inspection and dye penetration test from tube to tubesheet seal or strength weld
 Eddy current testing if it is necessary

Channel in Heat Exchanger Inspection

 Thickness measurement and making corrosion rate and remaining life calculation
 Inspection of gasket seating area, pass partition and nubbing for corrosion and
deformation
 Inspection of internal surface for fouling, corrosion and soundness of linings (if any)
 Balance hole inspection for corrosion and erosion
 Welding joints inspection for any possible cracks
 Reinforcement pad inspection and doing soap test if necessary
 Cathodic protection anodes inspection and replacement if necessary
 Diaphragm and division box visual inspection and dye penetration test of diaphragm for
any possible cracks (for high pressure exchangers)

Channel Cover in Heat Exchanger Inspection


 Thickness measurement and making corrosion rate and remaining life calculation
 Inspection of gasket seating area for corrosion and deformation
 Inspection for internal surface for fouling, liner, cladding and coating soundness
 Soap test in channel cover with liner
 Lifting lug weld joint inspection for any possible crack

Floating Head Inspection:

 Thickness measurement and making corrosion rate and remaining life calculation
 Inspection of gasket seating area, pass partition and nubbing for any possible corrosion
and deformation
 Girth flange weld joint inspection for any possible crack and corrosion
 Internal surface inspection for corrosion and fouling and soundness of liner, coating and
cladding (if any)

Expansion Joint Inspection

 The heat exchangers with expansion joints need to be inspected for:


 Flange inspections for corrosion and erosion
 Inspection from internal surface for corrosion and erosion
 Air test
 The tube and shell hydrostatic test need to be done after the above stated inspection
activities.