High Ambient - 50 Hz
Contents
Introduction 03
Index
Residential Products 08
Controls 78
02
Toshiba solutions
At Toshiba, we believe that “Evolution is leading the path to a
better future”. Through the decades, we have been constantly
creating innovative and high-quality electrical appliances to
increase our consumers’ satisfaction.
03
Toshiba Group
Toshiba’s origins go back to 1875 and two great inventors.
Hisashige Tanaka, the Thomas Edison of Asia, was renowned for his inventiveness. The sign that welcomed visitors to
Tanaka Engineering Works “Improving life with things people need,” expressed his deep commitment to prove people’s
quality of life.
Ichisuke Fujioka was Japan’s father of electronics. He manufactured the country’s first incandescent lamps and
pioneered the development of Japan’s electronics industry.
Today, more than 140 years after, Toshiba Group provides a wide range of products and services that feature the best in
innovative technologies and the finest quality.
By continually developing innovative technologies, we strive to create products and services that enhance human life,
and which lead to a thriving healthy society.
Today Toshiba
Toshiba offers a solution for all applications: residential, light commercial and larger commercial buildings.
Residential indoor units are designed to blend perfectly with all interiors and most efficient high-wall units incorporate
advanced filtration systems to deliver optimum indoor air quality.
For small commercial premises, products are designed to deliver optimum performance combined with energy efficiency.
Light commercial systems offer a wide range of indoor units for maximum flexibility.
For larger applications, VRF systems combine flexibility, energy efficiency and respect for the environmental. These
reliable systems offer a wide choice of stylish indoor units.
04
TOSHIBA History
Tanaka Seizo-sho
Hakunetsu-sha (1875)
(1890)
Tokyo Electric Company
(1899)
Shibaura Engineering
Works Co., Ltd. (1904)
Tokyo Shibaura
Electric Co., Ltd.
(Toshiba) (1939)
Toho Mining Co., Ltd.
(1933) Tokyo Fire Brick
1941
1943 Co., Ltd. (1918)
Toshiba Rolling Stock
Co., Ltd (1945) Dengyo-sha Prime
1950
Ichisuke Fujioka 1955 Mover Works Ltd. (1910)
1999
Toshiba Elevator and Toshiba Carrier Corp.
Building Systems 2001
Corporation
Hisashige Tanaka
05
Toshiba solutions
Toshiba offers a solution for all applications: residential, light commercial and larger commercial buildings.
Residential indoor units are designed to blend perfectly with all interiors and incorporate advanced filtration systems to
deliver optimum indoor air quality. For small commercial premises, products are designed to deliver top performance
combined with energy efficiency.
For larger applications, VRF systems combine flexibility, energy efficiency and respect for the environment, with a wide
choice of stylish indoor units.
Absolute comfort
Toshiba commitment to people
drives a focused attention for the
details in every stage of the
development process, form
design to user field tests.
Therefore the products and
systems installed feature higher
standard of indoor air quality,
sound levels, energy savings and
environmental awareness.
06
Product Lineup
Cooling capacity
Residential
BTU K 18 24 30 36 48 60
Type kW 5.6 7.1 9.0 11.2 14.0 16.0
HP 2.0 2.5 3.2 4.0 5.0 6.2
RAS-BKS-Q
RAS-G2KS-Q
RAS-KSG
Light Commercial
BTU K 18 24 30 36 48 60
Type kW 5.6 7.1 9.0 11.2 14.0 16.0
HP 2.0 2.5 3.2 4.0 5.0 6.2
4-way Cassette
USP Series
Standard Duct
BSP Series
Ceiling
CSP Series
Floor Standing
RAV - FS8G
VRF
Outdoor Unit 4 HP 5 HP 6 HP 8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP
Mini SMMS-e
SMMS-e
07
Residential
08
At Toshiba air conditioning, we believe we can make a difference. As a global vision for our evolving world, we are
committed to advancing research and development of super energy-efficient, cleaner technologies and to innovate
products that not only use significantly less energy but help maintain air quality through state-of-the-art air purification
systems for the home. Intelligent ideas that use less of our Earth’s resources, without sacrificing your personal comfort.
Toshiba constantly works to ensure that our air conditioners help protect the environment while delivering reassurance
and reliability to users around the world.
Toshiba’s considerable efforts in terms of development in technology & commitment to keep earth green results in
reducing harmful gas effect on environment from start point.
Toshiba constantly works to ensure that our air conditioners help protect the environment while delivering reassurance
and reliability to users around the world. Toshiba has earned international praise for building energy-saving products, and
for its environmental oriented production facilities. Toshiba is the first manufacturer in Japan to adopt R410A refrigerant
for all its products.
True quality in the residential environment goes beyond control of the air filtration. With Toshiba residential air
conditioners, air quality is guaranteed by many stages of filtration and additional functions such as pre-treatment, removal
of fine particles, viruses, bacteria and allergens or total purification.
09
BKS Series
Operating Mode
Select the operating Mode: Cooling, Dry
Mode (Dehumidification), Fan Only Heating
(only for heat-pump model) or Auto Change
over.
Temperature control
ECO
Achieve energy-savings of up to 25% compared
with standard settings without sacrificing comfort.
Hi POWER
Select “Hi POWER” for extra airflow intensity that
will cool you down much faster than standard
operation.
OFF Timer
Toshiba remote control provides a very
convenient automatic stop operation,
programmable for 0.5, 1 . 0 , 1 . 5 , …, 9, 10, 11,
12 hours. 11
Cooling Only ( HIWALL SINGLE SPLIT TYPE) Technical specifications
12
13
G2KS Series
14
Your health is our main concern Self Cleaning Function
Today, we spend more time in the air conditioner room,
This function is designed to reduce
either in the office or at home, “Clean airflow” means you
the humidity that causes mould to
can breathe with greater confidence.
form inside an air-conditioning unit.
It simply refreshes you in a natural way
When you turn off your air conditioner, an internal fan
automatically activates to dry out the coil. This removes
the moisture, which causes mould to form.
Toshiba Research Center understands your needs Normal Operation
Moisture stays trapped inside during
Are you bored to adjust the temperature and airflow
operation.
every time you switch on the air conditioner to suit with
the condition you are in the room?
How do i know that which temperature and airflow
setting is appropriate and provide comfort to me? Self-cleaning Function
I need my air conditioner to automatically switch on 20 minutes of fan operation after shut
before entering into the room and switch off before i get down dries the moist air and helps
out? reduce mould formation.
Hi-Power
without making undesired noise. Awake in the middle of the night because
you felt the room is too cold? Do you feel
One Touch My Comfort too cold during sleeping at night?
With Toshiba’s convenience feature,
Toshiba has assessed user preferences in your
when you activate the comfort sleep
region of the world to ensure that your needs can
button, your air conditioning system will
be fully catered for. The One Touch My Comfort
compensate for naturally lower night air
features customized temperature and airflow
temperatures so you can sleep in
settings, which will deliver you ultimate comfort
complete comfort.
with one simple push of the button.
Real time on-off
Eco-Logic We design real time on-off feature, which
Achieve energy-saving of up to 25% compared with standard can set on and off times or program a
setting without sacrificing comfort. setting to repeat every 24 hours.
15
Wired connectable remote controller
Timer Quiet
On and off timer or repeat By pressing the “Quiet” button on the
every 24 hours remote control, the indoor unit will be
operated at only 22dB*.
Hi-Power
Extra airflow to rapidly reach your
desired temperature setting.
Eco-Lgic
Achieve energy-savings of up to
25% compared with standard
settings without sacrificing comfort.
Comfort sleep
For optimum comfort, set the
temperature to rise by 1°C after 1
hour, then another degree after 2
hours, which will be maintained until
morning.
16
Cooling Only ( HIWALL SINGLE SPLIT TYPE) Technical specifications
Size 30K
System
Indoor RAS-30G2KS-Q
Outdoor RAS-30G2AS-Q
Power supply (V/Ph/Hz) 240 / 1 / 50
Capacity (kW) 7.70
Cooling T1
Indoor Noise
Sound Power (dB) 65
Sound Pressure (dB) 59
Outdoor Noise
Sound Power (dB) 74
HxWxD (mm) 320 x 1050 x 243
FCU
Dimensions
Net Weight (kg) 15
HxWxD (mm) 890 x 900 x 320
CDU
Dimensions
Net Weight (kg) 60
Chargeless (m) 15
Pipe
17
KSG Series
18
Wired connectable remote controller
Remote control display
Preset
Temperature selected
ON timer selected
19
Cooling Only ( HIWALL SINGLE SPLIT TYPE) Technical specifications
T1: Indoor temperature @ 27° CDB / 19° CWB & outdoor temperature @ 35° CDB
T3: Indoor temperature @ 29° CDB / 19° CWB & outdoor temperature @ 46° CDB
20
21
Light Commercial
22
Toshiba Air Conditioning is committed to delivering the highest standard of quality and innovation across complete
product range.
Serving for more than 40 years Toshiba Air Conditioning has led the world in creating better air conditioning and setting
new standards in comfort, energy efficiency and climate control.
The Toshiba Air Conditioning product range encompasses comprehensive light commercial products. Toshiba’s excellent
technological innovation & design are reliable and run on R410A non-ozone depleting refrigerant.
A complete range of indoor units satisfies all commercial applications: ceiling, cassette, ducted & free stand units.
The enlargement of the range with maximum cooling capacities up to 17 kW allows addressing even more commercial
applications with larger volumes.
Absolute comfort
Toshiba’s commitment to excellence drives a companywide focus on attention to the details through every stage of the
development process, from design to user field tests. Installations using our products and systems therefore feature a
high standard of indoor air quality, sound levels, energy savings, and environmental awareness.
Toshiba light commercial systems deliver exceptional operating comfort with extremely high design units. With
state-of-the-art technologies, flexible controls and improved installation Toshiba brings comfort and convenience to any
business installation.
If you want high performance, compact units and optimum comfort, Toshiba has the ideal product for your requirements.
With the continuous improvement of the design, Toshiba offer enhances system efficiency and reduces noise levels.
The new technology applied to light commercial series is able to satisfy applications that require cooling at 54 °C.
Powerful cooling at high outdoor temperature in Middle East climate.
23
24
TOSHIBA LC key features
Piping flexibility
R410A refrigerant for all range. Toshiba leads the industry with
support for height differences of 25*/30** meters on
Better energy saving with DC motor for indoor unit.
a single system and 35*/50** meters max pipe length.
DC motor ducted for easy installation & flexibility.
Single system
Height between 5F
4F
indoor & outdoor units 3F
25*m / 30m** 2F
1F
Water COMFORTABLE
Aqua Resin
coating
Air conditioners can get very dirty inside, collecting Non CFC refrigerant helps reduce
bacteria and allergens. Aqua Resin coated coil reduces our environmental impact.
the formation of water or oil on the coil unit as well as
minimizes dust accumulation on the coil.
25
4-Way Cassette type
Compact sizing
Compact size especially in height (256mm), offers wide range
of installation opportunities to customer.
256 mm***
*2.0 - 3.3HP
Receiver
Receiver standard fitted in the panel
Controller
Option Option
Premium
Standard supply Easy installation: Low height
Built –in drain pump: 850 mm. from the bottom side
Including: Wireless remote controller
300mm or less
850mm or less
Wide flow louver panels
Panel size is same for all
210mm models, RBC-U31PGXP(W)-IN1*.
It is easy to maintain a neat
appearance when multiple
units are installed.
*Available as an option.
26
4-Way Cassette Specifications
Equivalent HP 2.0 3.0 3.2
Indoor unit RAV-180USP-Q RAV-240USP-Q RAV-300USP-Q
Outdoor unit RAV-180ASP-Q RAV-240ASP-Q RAV-300ASP-Q
u Outdoor dimensions (H/W/D) mm 550 x 780 x 290 630 x 800 x 300 890 x 900 x 320
n Weight kg 44 49 65
i
t Sound pressure level dB(A) 50 53 56
Operating range °C 21 to 54°
u Outdoor dimensions (H/W/D) mm 890 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320
n Weight kg 70 109 -
i
t Sound pressure level dB(A) 56 63 63
Operating range °C 21 to 54°
T1 Rated conditions Cooling: Indoor air temperature 27°C DB / 19°C WB, Outdoor air temperature 35°C DB
T3: Indoor temperature @ 29° CDB / 19° CWB & outdoor temperature @ 46° CDB
27
Standard Duct type
Compact sizing
Compact size especially in height (275 mm.) offers wide range
of installation opportunities to customer.
275mm
275mm
RAV-xxxBSP Series
Flexible duct accessible: Design flexibility
Max. 120Pa with DC motor
Flexible Installation: Back or under air intake
High-lift drain pump
Controller 850 mm. from the bottom side
Option Option Option Filter an drain pump included as standard
Premium
Accessory: Wireless remote controller
Wired remote controller
Installation Flexibility
TCB-ACX32E2 RBC-AMT32E RBC-AMS54E-EN/ES Air filter and drain pump as High-lift drain pump:
Wireless remote kit Wired remote Wired remote standard Back or under air 850 mm, from bottom side
intake is selectable High-lift
Drain pump
drain pump
618 or less
Flexible duct is accessible, inside FCU
850 or less
300 or less
*Available as an option.
28
Standard Duct Specifications
Equivalent HP 2.0 3.0 3.2
Indoor unit RAV-180BSP-Q RAV-240BSP-Q RAV-300BSP-Q
u Outdoor unit dimensions (H/W/D) mm 550 x 780 x 290 630 x 800 x 300 890 x 900 x 320
n Weight kg 44 49 65
i
t Sound pressure level dB(A) 50 53 56
Operating range °C 21 to 54°
T1 Rated conditions Cooling: Indoor air temperature 27°C DB / 19°C WB, Outdoor air temperature 35°C DB
T3: Indoor temperature @ 29° CDB / 19° CWB & outdoor temperature @ 46° CDB
29
Ceiling type
Designed Wide Flap
The airflow angle is automatically set to the most suitable
setting according to your needs, an automatic swing mode
enables airflow to reach all areas of the room to create a
comfortable ambience.
New model
Previous model
TCB-DP31CE
*Available as an option. Drain pump kit Remove the hanging plate from indoor unit.
30
Ceiling Specifications
Equivalent HP 2.0 3.0 3.2
Indoor unit RAV-180CSP-Q RAV-240CSP-Q RAV-300CSP-Q
I
Outdoor unit RAV-180ASP-Q RAV-240ASP-Q RAV-300ASP-Q
n
d Capacity T1 / T3 kW 5.30 / 4.51 7.10 / 6.04 8.80 / 7.48
o
Cooling Power consumption T1 / T3 kW 1.64 / 1.90 2.20 / 2.51 2.52 / 2.90
o
r EER T1 / T3 (Btu/h / W) 11.0 / 8.1 11.0 / 8.20 11.90 / 8.80
Standard air flow (H/M/L) m3/h 900 / 720 / 540 1410 / 1000 / 750 1410 / 1000 / 750
u
n Sound pressure level (H/M/L) dB(A) 40 / 36 / 32 43 / 37 / 33 43 / 37 / 33
i
Indoor unit dimensions (H/W/D) mm 235 x 952 x 690 235 x 1269 x 690 235 x 1269 x 690
t
Weight kg 23 30 30
Power supply 1phase 220-240V 50Hz
O Compressor / Refrigerant type Rotary / R410A
u
t Connecting pipe dia.,Gas/Liquid side mm φ 12.7 / φ 6.40 φ 15.9 / φ 9.5 φ 15.9 / φ 9.5
d Min. pipe length m 3 3 3
o
o Max. pipe total length m 35 35 35
r Maximum height difference m 25 25 25
u Outdoor dimensions (H/W/D) mm 550 x 780 x 290 630 x 800 x 300 890 x 900 x 320
n Weight kg 44 49 65
i
t Sound pressure level dB(A) 50 53 56
u Outdoor dimensions (H/W/D) mm 890 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320
n Weight kg 70 109 -
i
t Sound pressure level dB(A) 56 63 63
Operating range °C 21 to 54°
T1 Rated conditions Cooling: Indoor air temperature 27°C DB / 19°C WB, Outdoor air temperature 35°C DB
T3: Indoor temperature @ 29° CDB / 19° CWB & outdoor temperature @ 46° CDB
31
Floor Standing Type (FS Series)
Features:
1. Auto Sweep
The discharge air direction is controlled left
High energy efficiency
and right automatically.
Environmental friendly refrigerant (R410A)
Better Air distribution by..
Auto Swing Vertical Louver (Left and Right) 2. Panel Lock
Harder Horizontal Louvers It will be activated by pressing the filter &
Newly designed Operation Panel & Display display change button together, over 3
Shiny smoked panel & controllable buttons seconds. This will help to avoid miss
Safety Lock ON/OFF function handling or controlling by non-authorized
LCD wireless remote controller person.
4. Self Diagnosis
When abnormal operation is diagnosed,
shows the error code in display.
Safety lock
6 5 4 3 2 1
Wind magnitude Operation mode
Outdoor ON/OFF
T1: Indoor temperature @ 27° CDB / 19° CWB & outdoor temperature @ 35° CDB
T3: Indoor temperature @ 29° CDB / 19° CWB & outdoor temperature @ 46° CDB
33
Business solution
34
TOSHIBA VRF History
Multi
System AC
1985
Multi System AC
Super Multi
1986
Multi controller
Wide Multi
1994
Optimal ref control
free branch piping
MMS
2000
Module CDU
Oil balance control
SMMS
2003
All inverter control
R410A DC twin rotary comp
Mini SMMS
2005
Small capacity VRF
SMMS-i
2010
3 inverter control,
High energy efficiency
SMMS-i
High Ambient
2012
3 inverter control,
Tropical VRF
Mini SMMS-e
32 Years experience
2016 in VRF technology
Small capacity hi-ambient VRF
35
36
MiNi-SMMS-e
The MiNi-SMMS-e system has been developed to achieve the best performance in a wide variety of commercial applica-
tions including shops, offices and large apartments, where unobtrusive appearance and quiet operation are important
advantages.
The extraordinary flexibility of this Toshiba system is guaranteed by the breadth of the range of SMMS-e indoor units – up
to 14 models MiNi-SMMS-e can be easily installed.
Key features
Best COP (4.06 for 4HP): represents state-of-art energy saving efficiency.
Wide range: up to 9 indoor units may be connected with a single outdoor unit.
DC Twin Rotary compressor delivers high efficiency and complete reliability.
Full SMMS-e control units available.
The compact design of the outdoor unit (smaller overall than standard VRF unit) means it can be easily installed virtually
anywhere; including on a balcony.
PMV Kit
The PMV kit is an option for supersilent operation, available for hotel rooms and residential applications where noise levels
are critical.
Ease of installation.
Integral condensate pump.
Low cost.
RESTAURANT
OFFICE VILLA
37
MiNi-SMMS-e Technology
38
Toshiba’s unique energy efficient air conditioning innovations and
technologies deliver high energy savings.
Adopting the highly efficient new DC twin - rotary compressors and variable
refrigerant pressure controlled inverter realized greater energy efficient
performance.
EER COP
100% load 100% load
T1 T3 T1
4.5 5.0
4.06 4.03
4.0
3.65 4.55
3.5 4.5
3.05 3.04 3.03 4.30
3.0
4.22
2.5
4.0
2.0
1.5
1.0 3.5
0.5
0 3.0
4HP 5HP 6HP 4HP 5HP 6HP
Cooling Heating
0.1Hz Saving
Compressors(Hz)
consumption(W)
Electricity
Capacity(%) Capacity(%)
Near -seamless 0.1 Hz steps Compressor steps less,
Fine control minimizes energy loss when Electricity consumption
changing frequencies. decrease as well.
39
Operating Temperature
Utilizing the newly designed compressor, Mini SMMS-e can operate under the range of
outdoor ambience with the expansion of cooling and heating temperature from -20°C to 52°C.
Cooling
-5 - 52 ( °C )
Heating
-20 - 15.5 ( °C )
-20 0 25 52 ( C)
Quiet Operation
PMV kit
(Optional part)
40
Comfort Operation with Low Sound
Night time operation mode
Sound level can be reduced by restricting the compressor and fan speeds.
Cooling 49 46
4HP
Heating 52 48
Cooling 50 46
5HP
Heating 53 48
Cooling 51 47
6HP
Heating 54 49
The optional PC bord: TCB-PCMO4E can be mounted in outdoor unit for sound reduction during night time.
41
User Friendly
You can always find a right type to suit with your property. A
neatness and well organized indoor space increase the
value of your property.
42
Flexible Design and Easy Installation
Easy installation
Possible to install the unit promptly and reduce both time and cost for installation.
MiNi-SMMS-e can be fit on your balcony, narrow street and any limited space.
250 mm
2230 mm
43
Technical specifications
Item
Compressor Type Hermetric Twin rotary Hermetric Twin rotary Hermetric Twin rotary
Note:
* Rated conditions
[T1]Cooling : Indoor 27 deg. C Dry Bulb /19 deg. C Wet Bulb, Outdoor 35 deg. C Dry Bulb.
Heating : Indoor 20 deg. C Dry Bulb, Outdoor 7 deg. C Dry Bulb / 6 deg. C Wet Bulb.
[T3]Cooling : Indoor 29 deg. C Dry Bulb /19 deg. C Wet Bulb, Outdoor 46 deg. C Dry Bulb.
Protection Devices: Discharge Temp. sensor,Suction Temp. sensor,High Pressure Sensor,
Low Pressure Sensor,Compressor case thermostat, PC Fuse Board.
44
MULTIPLE DESIGNS………COMPLETE SOLUTION
Room temperature goes state-of-the-art, when delivered by Mini SMMS-e. Be it a pleasing coolness in the height
of summer or the cosy warmth in the chill of winter. Mini SMMS-e creates a perfect environment that’s conducive
to people’s inherent wellbeing. Regardless if the installation is in a busy shop, office or a tranquil country spa hotel,
no other manufacturer offers such an extensive range of indoor units that can adjust and meet the most diverse of
requirements. Consistently and creatively putting you where you need to be – in your comfort zone!
HP 0,8 1,0 1,3 1,7 2,0 2,5 3,0 3,2 4,0 5,0 6,0
Model
kW 2,2 2,8 3,6 4,5 5,6 7,1 8,0 9,0 11,2 14,0 16,0
CASSETTE TYPES
Compact 4-way cassette type (620x620)
MMU-AP(...)MH-E
4-way cassette type
MMU-AP(...)HP1-E
DUCT TYPES
Slim duct type
MMD-AP(...)SPH1-E
CEILING TYPES
MMC-AP(...)HP-E
HIGH WALL TYPES
Series 7
MMK-AP(...)7HP-E
Series 3
MMK-AP(...)3H1-E
Console type
MML-AP(...)NH1-E
45
46
FFICIENCY
XPERIENCE
XCELLENCE
47
Energy saving
EER
Rated *
Cooling mode 50% load
w/w
7.0
6.5
6.0 5.83
5.69
5.5
5.19 5.11 5.05 5.01
5.0 4.96
4.5 4.42
4.21
4.0
3.81 3.81
3.5 3.85
3.52
3.0 3.43
2.5
2.0
Note:
The source voltage must not flucture more than ±10%.
* Indoor temperature: 26.7°C DB/19.4°CWB, outdoor temperature: 35°C DB (AHRI 1230 standard), power input of indoor units included.
48
Energy saving
The overall capacity range and the highest EER of 4.42 (15.08)
The SMMS-e has truly excellence as the industry’s top class in energy saving.
EER
Rated *
Cooling mode 50% load
BTU/W
22.0
8.0
6.0
4.0
2.0
Note:
The source voltage must not flucture more than ±10%.
* Indoor temperature: 26.7°C DB/19.4°CWB, outdoor temperature: 35°C DB (AHRI 1230 standard), power input of indoor units included.
49
Capacity range
New
8 10 12 HP
14 16 HP
18 20 HP
SMMS-e
System capacity expanded
With the SMMS-e, it is now possible to connect up to 56HP in
one system. 56 HP
SMMS-e
Installation flexibility
While expanding the maximum combination from 48 to 56HP in
one system. This helps save more time and expense on
additional unit system required in the previous model. The new
compact unit design also increases more flexibility on
installation with less foot print.
56 HP
SMMS-e is capable of covering up to 20HP with a single
module. Reducing pipe work and overall installation time.
50
Operating temperature range
Cooling
-5 - 54 ( °C )
Heating
-25 - 15.5 ( °C )
-25 0 25 50 ( C)
Note : Based on equivalent piping length of 7.5 m and piping height difference of 0 m.
Vapor flow
44.2
5F
42.6
up to 80* pa
40.9
4F
39.3
3F 36.8
35.1
2F 33.5
51
Enhanced Comfort
Undersupplied
52
Total system control
53
DC twin rotary compressor
Crank
SMMS-e 64
cm3
Displacement volume Cylinder
12
2-stage vane
Contact portions
With 2-stage vane innovatively
designed to reduce friction while SMMS-e
2stage
increasing hardness and enhancing vane
performance at its best.
Shaft
Current-SMMS New-SMMSi
SMMS-e
Infinity variable control d ’s
W orl in*
Infinity variable control adjusts s t
be lass
compressor rotation speed in 0.1Hz its c
near-seamless 0.1 Hz steps.
Compressor Hz
54
Heat exchanger
14HP 14HP
Previous model SMMS-e
*Increased
13%
the surface area
of the total pipe
Use Use
SMMS-e
* For higher capacity model.
55
Precise refrigerant flow
One of the keys to delivering precision refrigerant flow and enhanced comfort is the Toshiba pulse motor valve (PMV)
control. The PMV control prevents refrigerant from flowing to indoor units that are not operating. The system reduces
bypass loss and achieves tighter control over the compressor capacity of the outdoor unit.
Outdoor unit
Heat
exchanger
Target capacity
Capacity
56
Reliability
Backup operation
In case of a compressor failure, SMMS-e can keep working with the backup operation under All Inverter Control to
compensate a failed compressor or header unit. This backup operation is available in both a single system or as
a module.
80%
30%
Noon Comp1/Comp2
Ou
p rise tdo
or t
r tem em
doo pd
Out own
Morning Evening
Comp1/Comp2 Comp1/Comp2
57
Piping design flexibility
Total 1,000m
piping length SMMS-e Max. total length
Farthest pipe
from 1st branch 90m
Farthest equivalent length Height between indoor units
The maximum equivalent distance between outdoor Another industry’s top class is a maximum vertical
unit and farthest indoor unit tops at 235 meters, distance between indoor units which reaches up to
which tops the industry class. 40 meters, equal to an entire 11-storied building.
SMMS-e’s enhanced piping capabilities result in
more benefits for the system design, installation
flexibility, as well as the less installation cost.
Farthest
58
equivalent length 235m
Piping capabilities summary
Piping capability can provide more benefits for the system design, the installation flexibility, and the installation cost.
11F 11F
10F 10F
9F 9F
8F 8F
7F 7F
6F
5F
1 2 6F
5F
4 3
4F 4F
3F 3F
2F 2F
1F 1F
SMMS-e
ø 28.6 mm
NEW
20 HP
59
Propeller fan
1.5 dB
Reduce
Air volume
60
Heat
Connectable
exchanger
no. of indoor unit
Indoor lineup
Cooling capacity
Type kW 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0
HP 0.8 1.0 1.25 1.7 2.0 2.5 3.0 3.2 4.0 5.0 6.0 8.0 10.0
Compact 4-way
cassette type (620 x 620)
Ceiling type
Floor standing
concealed type
Floor standing
cabinet type
Console type
61
SMMSe wave tool
With SMMSe wave Tool, you can read and write data from outdoor unit directly on your smart phone without the needs
of connecting PC or opening cabinet.
By the new smart phone application, the testing and commissioning can be done without opening the cabinet.
SMMS-e
62
Available data
Whether the product data, system data, fault history or testing and commissioning, all can be obtained easily even in
case of under service maintenance or power failure. The data can be easily sent to the distant office via email. Possible
to receive system data by e-mail without moving from your office and the operation conditions can be checked in the
office.
Fault
history
Available
System
data
data
Test operation
result
Smart phone
@lert
63
Outdoor units
Standard model
Model Name
50 Hz MAP0806HT8P-ME MAP1006HT8P-ME MAP1206HT8P-ME MAP1406HT8P-ME MAP1606HT8P-ME MAP1806HT8P-ME MAP2006HT8P-ME
(MMY-)
Cooling capacity*¹ (kW) 22.4 28.0 33.5 40.0 45.0 50.4 56.0
Cooling capacity*² (kW) 20.3 25.2 26.8 32.5 36.0 42.8 44.8
Heating capacity (kW) 25.0 31.5 37.5 45.0 50.0 56.0 63.0
No’s of connectable
13 16 20 23 27 30 33
Indoor units
Model Name
50 Hz AP2216HT8P-ME AP2416HT8P-ME AP2616HT8P-ME AP2816HT8P-ME AP3016HT8P-ME AP3216HT8P-ME AP3416HT8P-ME
(MMY-)
Cooling capacity*¹ (kW) 61.5 67.0 73.5 80.0 85.0 90.0 95.4
Cooling capacity*² (kW) 52.0 53.6 59.3 65.0 68.5 72.0 78.8
Heating capacity (kW) 69.0 75.0 82.5 90.0 95.0 100.0 106.0
No’s of connectable
37 40 43 47 50 54 57
Indoor units
Model Name
50 Hz AP3616HT8P-ME AP3816HT8P-ME AP4016HT8P-ME AP4216HT8P-ME AP4416HT8P-ME AP4616HT8P-ME AP4816HT8P-ME
(MMY-)
Cooling capacity*¹ (kW) 100.8 106.4 112.0 120.0 125.0 130.0 135.0
Cooling capacity*² (kW) 85.6 87.6 89.6 97.5 101.0 104.5 108.0
Heating capacity (kW) 112.0 119.0 126.0 135.0 140.0 145.0 150.0
No’s of connectable
60 64 64 64 64 64 64
Indoor units
Model Name
50 Hz AP5016HT8P-ME AP5216HT8P-ME AP5416HT8P-ME AP5616HT8P-ME
(MMY-)
64
High efficiency model
Model Name
50 Hz AP1626HT8P-ME AP1826HT8P-ME AP2026HT8P-ME AP3026HT8P-ME
(MMY-)
Model Name
50 Hz AP3226HT8P-ME AP3426HT8P-ME AP3826HT8P-ME AP4026HT8P-ME
(MMY-)
Y-shape branching joint Branch headers Outdoor unit connection piping kit
Appearance
(4-branch headers)
65
Outdoor unit specifications
Model name Heat Pump 50Hz (MMY-) MAP1406HT8P-ME MAP1606HT8P-ME MAP1806HT8P-ME MAP2006HT8P-ME
Protective devices: Discharge temp. sensor / Suction temp. sensor / High-pressure sensor Low-pressure sensor / High-pressure switch / PC board fuse
*1 The source voltage must not flucture more than ±10%.
* Indoor temperature: 26.7°C DB/19.4°CWB, outdoor temperature: 35°C DB (AHRI 1230 standard), power input of indoor units included.
** Indoor temperature: 29°C DB/19°CWB, outdoor temperature: 46°C DB (ISO 15042 standard), power input of indoor units included.
*2 Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
66
Outdoor unit specifications
Protective devices: Discharge temp. sensor / Suction temp. sensor / High-pressure sensor Low-pressure sensor / High-pressure switch / PC board fuse
*1 The source voltage must not flucture more than ±10%.
* Indoor temperature: 26.7°C DB/19.4°CWB, outdoor temperature: 35°C DB (AHRI 1230 standard), power input of indoor units included.
** Indoor temperature: 29°C DB/19°CWB, outdoor temperature: 46°C DB (ISO 15042 standard), power input of indoor units included.
*2 Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
67
Outdoor unit specifications
Protective devices: Discharge temp. sensor / Suction temp. sensor / High-pressure sensor Low-pressure sensor / High-pressure switch / PC board fuse
*1 The source voltage must not flucture more than ±10%.
* Indoor temperature: 26.7°C DB/19.4°CWB, outdoor temperature: 35°C DB (AHRI 1230 standard), power input of indoor units included.
** Indoor temperature: 29°C DB/19°CWB, outdoor temperature: 46°C DB (ISO 15042 standard), power input of indoor units included.
*2 Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
68
Outdoor unit specifications
Protective devices: Discharge temp. sensor / Suction temp. sensor / High-pressure sensor Low-pressure sensor / High-pressure switch / PC board fuse
*1 The source voltage must not flucture more than ±10%.
* Indoor temperature: 26.7°C DB/19.4°CWB, outdoor temperature: 35°C DB (AHRI 1230 standard), power input of indoor units included.
** Indoor temperature: 29°C DB/19°CWB, outdoor temperature: 46°C DB (ISO 15042 standard), power input of indoor units included.
*2 Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
69
Mounting surface
of bottom plate
Model: MMY-MAP0806HT8P-ME Foundation
60
MMY-MAP1006HT8P-ME
100
MMY-MAP1206HT8P-ME
780
790
610
755
670
700
(Anchor bolt hole pitch 4-15x20
100
990 (Long hole)
60
700 Foundation
(Anchor bolt hole pitch)
50
1800
1595
(75) (*1)
Note:
1. If there is an obstacle at the upper side of the outdoor unit, set
687
the top end of the outdoor unit 2000mm apart from the obstacle.
(*1)
2. Limit the height of the obstacle surrounding the outdoor unit to
75
284
273
800mm or less from the bottom end of the outdoor unit.
(220)
160
3. Draw out the pipe procured locally to the front of the outdoor unit
horizontally and keep 500mm or more between the outdoor unit 500 L-shape pipe
and traversing pipe if placing pipe transversely. 85
(*1) Cutting position of L- shape pipe
4. Dimensional drawing of corrosion heavey protection model is
Square hole (for freight handling) 2-60X200
the same as that of standard model. Gas pipe connection port Ø A
Balance pipe connection port Ø 9.5
Liquid pipe connection port Ø 12.7
(Unit:mm)
Mounting surface
of bottom plate
Model: MMY-MAP1406HT8P-ME Foundation
60
100
MMY-MAP1606HT8P-ME
(Anchor bolt hole pitch)
780
790
610
670
755
920
100
(*1)
(75)
Note:
687
the top end of the outdoor unit 2000mm apart from the obstacle.
160
(220) (*1)
(Unit:mm)
70
Mounting surface
100
Model: MMY-MAP1806HT8P-ME Foundation
60
of bottom plate
MMY-MAP2006HT8P-ME
755
610
670
(Including steady leg)
(Anchor bolt hole pitch)
755
780
790
Foundation
60
100
1310
1500
(Achor bolt hole pitch)
1310 4-15×20
4-15×20
(Anchor bolt hole pitch) (Long hole)
(For additional strength)
(Long hole) 1600
50
1800
1595
Note:
(75) (*1)
1. If there is an obstacle at the upper side of the outdoor unit, set
(*1)
the top end of the outdoor unit 2000mm apart from the obstacle.
687
75
2. Limit the height of the obstacle surrounding the outdoor unit to
(220)
160
800mm or less from the bottom end of the outdoor unit.
284
200
3. Draw out the pipe procured locally to the front of the outdoor unit
horizontally and keep 500mm or more between the outdoor unit
and traversing pipe if placing pipe transversely.
720 L -shape pipe
4. Dimensional drawing of corrosion heavey protection model is
85
71
Indoor units line-up
4-way air discharge Compact 4-way cassette 2-way air discharge 1-way air discharge
Cooling capacity (HP equivalent) Concealed duct type
cassette type (620 × 620) type cassette type cassette type
72
Floor standing Floor standing Floor standing Fresh air intake
Cooling capacity (HP equivalent) Console
cabinet type concealed type type indoor unit type
73
TO-RC-WiFi-1
Controls
74
75
Air-conditioning management system on site
TO-AC-KNX-64
KNX
TCB-IFCB640TLE
TCB-IFLN642TLE
Open
Network LonWorks
System
TCB-IFMB641TLE
Modbus
RS485
TCC-LINK
BMS-IFBN640TLE
BACnet
BMS-IFLSV4E
RS485
Energy monitoring
Relay I/F Power Meter
Touch-screen Controller
BMS-CT5121E
Digital I/O Relay I/F
I/O
Device
76
Power peak-out control
board TCB-PCDM2E
Residential Product
External master ON/OFF
board TCB-PCMO2E
Error output control board
Error output control board
Compressor operation/ General Purpose I/F
TCB-IFCG1TLE
system operation ratio
TCB-PCIN4E
MiNi-SMMS
TCC-LINK
Remote ON/OFF
TCB IFCB-4E2
TO-RC-WiFi-1
Smart Phone Lite-Vision plus Wired remote controller Wired remote controller Simple remote controller Wireless remote Remote Sensor
Application Interface Remote Controller with Weekly timer RBC-AMT32(31)E RBC-AS41E2 controller TCB-TC41LE
TO-RC-WiFi-1 RBC-AMS54E-ES RBC-AMS41E
RBC-AMS54E-EN
77
Wired remote controller
RBC-AX32UW(W)-E
Integral receiver (For 2-way air
discharge cassette)
( MMU-AP***2WH1)
78
Central remote controller
ON-OFF controller
TCB-CC163TLE2
• Individual control of up to
Central remote controller
16 indoor units.
BMS-CM1280TLE
• Setting of simultaneous ON/OFF
3times per day combined with the
• Operation
weekly timer.
Individual operation of 128 indoor units available
Return Back Operation
Weekly Schedule Operation*
(ON/OFF)
* Schedule timer necessary
• Monitoring
Zone setting (64 zones x 2)
Individual unit operation mode operation restriction
Alarm display
Control input
Status output Schedule timer
TCB-EXS21TLE
• Schedule timer mode
– 6 programmings per day
– Enabling 8 groups to be programmed
– A maximum of 64 indoor units can be
controlled
– A maximum of 100 hours back-up
power supply
• Weekly timer mode
– 7 types of weekly schedule and 3
programmings per day
Other
Remote sensor Wired remote controller for air to air heat exchanger
TCB-TC41LE NRC-01HE
Install this sensor when outside air • Up to 8 units of the Air to Air Heat Exchanger can be operated using this
has been introduced or when remote controller.
overcooling and overheating are to • Control by 2 remote controllers is available. Two remote controllers can
be minimised. operate a single Air to Air Heat Exchanger.
• Air conditioning units may be controlled in addition to controlling the Air to
Air Heat Exchanger.
• Central control allows linked ON/OFF operation of air conditioner and Air
to Air Heat Exchanger.
• Central control can be set to allow standalone operation of the Air to Air
Heat Exchanger.
• Switchable ventilation modes (Automatic/Air to Air/Normal)
• Switchable ventilation air volume (Extra-high/High-Low)
79
Central Control Device
TCC-Link Line 1
Digital Input Output signal
TCC-Link Line 2
BMS-IFDD03E
TCB-PCNT30TLE2*
NETWORK HUB
Up to 32 User accounts
Max. 4 Concurrent Users
Equipment List
Device Number of pieces Description
Energy consumption history (days) Energy consumption comparison Alarm list Energy consumption history (Hours)
80
62
Touch-screen controller
• Touch-screen controller
Using the touch-screen controller provides a clear display and enables easy operation.
A maximum of 512 units are controllable using the one-touch controller.
• Function
– Operation monitoring
– Operation control
– Operation Schedule
– Error Code
Touch-screen Controller – Alarm List
BMS-CT5121E – Energy monitoring/Billing
– Digital I/O Signal Control
– Web function
– Email alert
– Graphical report
– Building layout
Up to 8 Up to 8 Up to 8
Relay Interface BMS-IFLSV4E Relay Interface BMS-IFWH5E Relay Interface BMS-IFDD03E
For TCS-NET For Energy Monitoring For Digital I/O
(Optional) (Optional)
CONTROL WIRING
RS-485 Network
Digital Output 1
Power Meter 1
- Digital Output 4
81
Open network systems
BACnet ®
BACnet Interface Features
The Toshiba BMS-IFBN640TLE BACnet
Interface can be connect to the TCC-Link • Maximum 64 Indoor Units/Groups and 16
Central Control Network to enable Outdoor Systems can be connected to a
control of the attached Air Conditioner single Interface.
product from a BACnet Building • TCB-PCNT30TLE2 Network adaptor
Management System. required for connection of DI/SDI to
BACnet System.
TCC-Link Network
BMS-IFBN640TLE
TCB-PCNT30TLE2*
KNX ®
KNX Interface
The KNX interface manages the Toshiba VRF System air conditioning system as a KNX®
device to communicate with the custormer s Home automation.
Accessible to 64 units per one ,
Signals and provides the following functions:
– ON/OFF
– Mode: cool/heat/fan
– Air flow and fan speed
TO-AC-KNX-64 – Temperature setting
– Filter reset
Main bus
KNX Network
KNX Interface
TO-AC-KNX-64
82
Open network systems
LonWorks ®
LonWorks Interface
The LonWorks interface manages the SMMS-i air conditioning system as
a Lon device to communicate with the custormer’s Building Management
System and to monitor operational status.
A maximum of 64 units are controllable per interface.
Main Bus
Local supply
LN Interface
TCB-IFLN642TLE
Modbus ®
Modbus Interface
The Modbus® interface manages the Toshiba VRF System air conditioning system as a Modbus®
device to communicate with the custormer’s Building Management System.
Accessible to 64 units per one TCB-IFMB641TLE, 15 TCB-IFMB641TLEs on one
Modbus® Master (prepared by user).
Local supply
Main Bus
Modbus® Interface
RS-485 TCB-IFMB641TLE
83
Smart phone apps
Toshiba
2 5
Internet
A B
4
3
VRF DX Kit
The VRF DX Coil Interface enables a third party air handling unit with a DX Coil to be connected to a Toshiba VRF system. The interface consists
of a VRF DX Coil Controller (MM-DXC010 / MM-DXC012) and a VRF DX Coil Valve Kit (MM-DXV080 / DXV140 / DXV280).
Product Features
DX Interface SMMSe diversity ratio: 60% to 110%
• Compatible with Toshiba control accessories.
• External ON / OFF input.
• Safety cut out input (recommended for fan failure input).
• Air temperature control achieved using TA sensor positioned in return air stream (set with remote controller).
84
NOTES
85
AHIC062017_G_T3_Qatar
Notice: Product listed in this leaflet use HFC refrigerant R410A with a GWP of 2,088*.
Toshiba is committed to continuously improving its products to ensure the highest quality and reliability standards and to meet local regulations and market
requirements. All features and specifications are subject to change without prior notice.
* The GWP value is calculated based on information provided in the EU F-gas Regulation and IPCC Fourth Assessment Report.