Вы находитесь на странице: 1из 36

Usha Electric Power Pvt. Ltd.

The Next Generation Engineering for Power Efficiency

delhi@ushacapacitor.com www.ushapower.com +91 88260 18055

Innovation and
Excellence
for more than
Two Decades
Usha Power
Shunt Capacitor

Prelude
We at Usha Power want everyone to have scale. In addition, in power distribution with
access to Reliable, Efficient and Quality Low and Medium Voltage Networks, PFC
Energy, which is Sustainable. We are focuses on the Power Flow (CosФ) and the
committed to innovate ways and means to optimization of Voltage stability by
address these needs and consequently, We generating reactive power – to improve
as the Leader in Energy Saving Technology, voltage quality and reliability at distribution.
provide the most relevant, state-of-the-art This will ensure not only enhancing Power
technology solution of Power Factor Quality but also Improvement of Power
Improvement through our wide range of Factor thus saving energy cost and fast
Products. “Return On Investment” and Usha Power is
available at your back and call to provide
The availability of Uninterruptable Quality you this service round the clock.
Electrical Power and saving of Energy is the
need of the hour. Simultaneously,
awareness for the same is also increasing
globally.

To achieve these set goals, Power Factor


Correction Capacitors (PFC) and Harmonic
Filters are to be installed on an accelerating

Welcome to the world of “Usha Power”


make Industrial Capacitors for
Power Factor Improvement

www.ushapower.com
Usha Power
Shunt Capacitor

Introducing the Company


Profile of a Leader
Incorporated as Usha Sales Corporation in 1992 UCL is a leading manufacturer of LV/HV Power
to undertake marketing of Electrical Capacitors Capacitors under the commercial brand name
in Eastern Part of India, based in Kolkata (then of “USHA POWER”. Our Broad portfolio
Calcutta). The company changed its includes Capacitors, Series reactors, APFC
constitution in the year of 2003 and formed as Relays, APFC Harmonic Filter, Thyristor
Usha Capacitors Pvt Ltd. Later, in the year 2004 Switched Harmonic Panel. As an innovative
Usha ventured into Electrical Turnkey Project technology- driven company, Usha focus
Execution Business with the name of, Usha technologically on demanding growth markets
Techno Power Pvt. Ltd. under the flagship of in the areas of Steel,
USHA GROUP. Power, Cement and
o t h e r H e a v y
Usha Group, the first generation business Industries. We offer ISO:9001-2008
entrepreneur with over two decades of our partners both
experience in Electrical Capacitors and standard Capacitors 14001-2004
Electrical Turnkey Projects has achieved an as well as application- Certified Company
exponential growth and success in the span of a specific solution.
very few years. With this success story behind,
Usha became a coveted Usha Capacitors Ltd. USHA has designed, engineered, manufactured
in 2014. and marketed products in India and abroad. We
are continuously strengthening our global
The group has completed and successfully research and development network by
delivered more than 120 Electrical Turnkey expanding R & D activities at our Plant locations.
Projects across India and abroad. To achieve
such a feat, Usha Group has been backed by a The Capacitor Division of Usha Group is
team of over 125 competent professionals engaged in manufacturing of Capacitors
including highly qualified Engineers, MBAs etc. according to national/ international standards.
Additional strength of Usha Group is its strong “Usha Power” Make Capacitors are tested by
infrastructure and high growth potential. Usha CPRI (Bengaluru), ERDA (Vadodara), NTH
Capacitors Ltd (UCL) is an ISO:9001-2008 / (Kolkata). We are manufacturing products as per
14001-2004 Certified Company. BIS/IEC standards and got ISI and CE
certifications as well.

www.ushapower.com
02
Usha Power
Shunt Capacitor

The Group
Comprises of the following 4 Companies

Usha Techno Power Pvt. Ltd.


engaged in Designing, Engineering,
Manufacturing and Supplying of
Electrical Panel Boards like, LDB, PDB,
Control Desk, Bus Duct up to 33 kV,
Drives Panel, VVFD Soft Starter Panel,
AMF & Capacitor Control Panel, DG
Synchronization Panel, PCC Panel, PLC
Automation Drive Panel, Junction Box,
Harmonic Analysis.
Usha Capacitors Limited
involved in Designing, Engineering, Meter Division, an Independent
Manufacturing of LV Shunt Capacitors, HV Strategic Business Unit, operates within
Capacitors, Surge Capacitors, Series the framework of this Company
Reactors (HV & LV), Furnace Duty Water
USHA
Cooled Capacitors, Thyristor Switch, CAPACITORS
Vacuum Contactor. LIMITED

Usha
Electric TM
Usha
Power Pvt. Techno
Ltd. Power
Pvt. Ltd.

Usha Capacitors
Industrial
Corporation
Usha Capacitors Industrial Corporation
engaged in Electrical Consultancy, Energy Audit,
Usha Electric Power Private Limited Power Factor Management Service, AMC, etc.
engaged in Electrical Turnkey Projects for
High Rise Buildings, Hotels, Textiles
Industries, Cement Industries, Power
Generation Plants, Steel Industries,
Chemical Industries, Mines, Agro-based
Industries, Cold Storage, Bottling Plant
and Utilities etc.

03 www.ushapower.com
Usha Power
Shunt Capacitor

Our Vision,
Mission & Our Values
Our Vision:

To be the World-Leader in Capacitor, Reactor, Panel and


Breaker Products.

To be the Doyen in Quality and Services for our Valued


Customers.

To create Value for all our Stakeholders.

Our Mission:
To supply Zero-defect Products and Services to the delight
of the Customers.
To attain all our defined Goals through a Highly Effective,
Lean but strong and Fast-Pacing Organization.
To Provide Uninterrupted, Affordable Quality as well as
Reliable Products and Services.
To become the most Customer Caring Company
worldwide.
To be a Thousand Crore Company in less than 5 years time.

Our Objectives:
To be the Most Preferred Vendor (MPV) for all our
Customers, however small or big.
To ensure growth through innovation by encouraging Ideas,
Talent and Value system.
To spearhead excellence in all our Manufacturing/ Business
Activities through sincerity and diligent effort of our
Employees at all levels.

Guided by
Strong Values

www.ushapower.com
04
Usha Power
Shunt Capacitor

CEO’s Message
Focus on Being the Best
I feel privileged in penning this message as the CEO of Usha Group of Companies, an
organization whose seeds were sown in the early nineties. Over 2 decades, Usha has
grown significantly through a combination of technical excellence and strategic
acumen ship and today, we are one of the leading Industry-ready Electrical
Equipment Manufacturers in the country.

Whilst Capacitors and Panel remain at the heart of what we do, we have also
developed and expanded the range of services like Electrical Installation as well as
Design, Engineering and Turnkey Project Management along with Annual
Maintenance Contract and Energy Audit.

At Usha Group, our entire operation revolves around because our people are a treasured resource and that
one objective which is: has worked
Exceeding all Logical Expectations & wonders with our
Meeting Diverse Needs of our Customers and Customers as
well as other
this focused approach influences every facet of the Stakeholders.
way we Develop, Manufacture and Install the extensive I hope our portal
range of products sought by our customers; creates an
opportunity for
to make our service impressive and memorable for our valued
our clients we, continuously innovate with practical visitors around
solutions that breathe new vitality into daily the world to learn
interactions. more about our
leading-edge
There are exciting, yet challenging times at Usha Power operations, electrifying performances, strategies,
to which we ponder substantially and we continue to services, sustainability, initiatives and values. This
set benchmarks in the field of innovation, technology expression is part of the external manifestation of our
and engineering on real time basis. Usha has been commitment to servicing the Electrical Industry as;
playing a major role in nation building since inception. Usha is One Stop Shop for all your Electrical needs.
In the first place, by conducting Energy Audit in the
nook and corner of the country, bringing out clearly I take this opportunity to express my gratitude and
drastic improvement needed in the Quality of Power appreciation to all the stakeholders of Usha Power,
supply. We do these by improving the Power Factor of who have always been demonstrating their solidarity in
the electricity supply at Consumers' end as well as their association with us.
reducing the Transmission and Distribution losses on
the Supply side. My sincere thanks to all our Global Associates,
In addition to this, we have also been handling our Financing Partners, Vendors, Customers, Departments
Corporate Social Responsibility (CSR) as one of our of Governments, Local Authorities, and most
prime responsibilities towards the society as a importantly, my dear Colleagues of Usha Power.
business principle and as a matter of humility.
M Pandey
At Usha Power we strongly believe in “team-playing” CEO

05 www.ushapower.com
Usha Power
Shunt Capacitor

Our Employees
Our employees are specialists in their fields. They bring a strong service ethos to everything they do. They take pride
and ownership in the jobs they do. At Usha, we bring passion, pride and experience together.

We pull together the right people, processes and expertise to take service from “good enough” to “great”. We apply
the best-in-class practices, domain knowledge and expertise, proven technologies, and innovation to assist our
clients in responding to new mandates and expanded missions. Usha's clients come back repeatedly with
confidence that we have the expertise to take service delivery to the next level of performance. We know how to
make services run smoother, smarter and more efficiently.

We have earned a reputation for collaborating with government and non-government agencies and have been
entrusted with delivering vital services for the Government, Leading Private and Public sector Organizations across
the world. The key to that success has been the trust of our customers. We have a history of designing and deploying
long-term solutions that has been generating meaningful outcomes since inception.

Our Structure

CMD
BOARD OF
DIRECTORS

COO

COLLABORATION VP: VP:


FINANCE LRP CRM
& ACQUISITION WORKS NEW DELHI

www.ushapower.com
06
Usha Power
Shunt Capacitor

One Stop Solution


Wide Range of Products

HV
Fix

Mixed Dielectric
e

ayer sign
dC

Capacitors
a pa

e
Dou + Foil D
cito

ign
ble L
HV
rB

ye es
AP r

Film
olle

La il D
ank

FC ont
r

r
gle Fo
Sy or
C

Sin lm +
ste act
m rF

Fi
OWER USHA P TP
ow
e
P O H
Rela
y
HV In
A T AP
FC
H
SH

WE
door
Fixed se Single
CT
POWER U

Bank Single Pha


R
USHA Three Phase Single CT

Usha Power Three Phase-


ank 3 CT
Pole Mounted B Shunt Capacitor
APFC
P
A

Relay
O
H

quare Thrys
WE
US

l a r S itor S
ngu pacitors witch
R
Recta
LV
Ca USHA POWER S erie
r HV sR
to eac
aci
Se tor
p rie
sR
ca
Wa

p ea
a cto
Uc
te
Su
aci ty

r
rC
ap Du

pe

d
s

fille
Heavy

oo
tor

rH
Dielectric ty Double

led
e
d c vy

s
ea

Ga
(MKP) Typ
ille Hea

Ca
vy
Duty H

p ac
Du
ly F al

ito
ty
Jel indric

rs
HE
Heavy Du

EXL Ty

XL
l
Cy

Typ
pe

07 www.ushapower.com
Usha Power
Shunt Capacitor

Products
Low Voltage Capacitors
MPP Standard Design Capacitors
MKP Gas Filled Heavy Duty Type
Heavy Duty Hexl Jelly Filled Type
Super Heavy Duty Hexl Type [Oil Filled/Jelly Filled/Gas Filled]
App Capacitors [BOPP Film +Foil Design] Oil
Filled Single/Double Layer Type
Mixed Dielectric Capcitors

Medium Voltage Capacitors


FILM + FOIL DESIGN from 2.2 kV to 24 kV in single unit
Automatic Pad Mounted MV Capacitors Bank upto 11 kV

High Voltage Capacitors


SVC Upto 700 kV

LV/MV Series Reactors Copper wound /


Aluminum Wound
6% / 7% / 14% Tuned and Detuned Reactors
MV Current Limiting Reactors of 0.2%
MV Harmonic Filter Reactors Alumunium
Wound Dry Air Core Type of 6%

Micro Processer Based APFC Relays


From 4 Step to 6, 8, 10, 12, 14, 16 Stage
HT APFC Relay

Water Cooled Capacitors


MV High Frequency Upto 1000 Hz

www.ushapower.com
08
Usha Power
Shunt Capacitor

A Few Words Behind High Quality


Cost Effective Power
How Reactive Power is Generated? Factor approaches 1 the reactive (nonworking) Power
Every Electric Load that works with magnetic fields approaches 0.
(motors, chokes, transformers, inductive heating, arc
welding, and generators) produces a varying degree of
electrical lag, which is called inductance. This lag of
Working (real) Power
inductive loads maintains the current senses (e.g.
positive) for a time even though the negative-going
voltage tries to reserve it. This phase shift between
current and voltage is maintained, current and voltage Total
(apparent)
having opposite signs. During this time, negative Power Power
or Energy is produced and fed back into the network.
When current and voltage have the same sign again, the
same amount of energy is again needed to build up the To understand Power Factor, visualize a horse pulling a
magnetic fields in inductive loads. This magnetic reversal railroad car down a rail road track. Because the rail road
energy is called Reactive Power. track are uneven, the horse must pull the car from the
In AC networks (50/60 Hz) such a process is repeated 50 side of the track. The horse is pulling the rail road car at
or 60 times a second. So an obvious solution is to briefly an angle to the direction of the car's travel. The Power
store the magnetic reversal energy in Capacitors and required to move the car down the track is the working
relieve the network (Supply Line) of this Reactive Energy. (real) Power. The effort of the horse is the total (apparent)
For this reason, Automatic Reactive Power Power.
compensation systems (Detuned/Conventional) are
installed for large loads like industrial machinery. Such Because of the angle of the horse's pull, not all of the
systems consist of a group of Capacitor units that can be horse's effort is used to move the car down the track. The
cut in and cut out and which are driven and switched by a car will not move side ways; therefore, the side wards pull
Power Factor Controller. of the horse is wasted effort on working (reactive) Power.

Low Power Factor is expensive and inefficient. Many For example, using the Power triangle illustrated below, if
utility companies charge you an additional fee if your Power Factor =
Power Factor is less than 0.85. Low Power Factor also
reduces your electrical system's distribution capacity by Power Factor=
increasing current flow and causing voltage drops. This
Real Power = 100kW
fact sheet describes Power Factor and explains how you
can improve your Power Factor to reduce electric bills Real Power=
Reactive 100kW and
and enhance your electrical system's capacity. Power= Apparent Power=
100kVAR 142kVA then
Reducing Power Factor Cost Power Factor=
Apparent 100/142=0.70 or 70%
The angle of the horse's pull is related to Power Factor, Power=
which is defined as the ratio of real (working) Power to 142kVA
Apparent (total) Power. If the horse is led closer to the
center of the track, the angle of sidepull decreases and
the real Power approaches the value of the Apparent
Power. Therefore, the ratio of real Power to Apparent This indicates that only 70% of the current provided by
Power (the Power Factor) approaches 1. As the Power the electrical utility is being used to produce useful work.

09 www.ushapower.com
Usha Power
Shunt Capacitor

Cause of Low Power Factor


Low Power Factor is caused by inductive loads (such as transformers, electric motors, and high-intensity discharge
lighting) which are a major portion of the power consumed in industrial complexes. Unlike resistive loads that create
heat by consuming kilowatts, inductive loads require the current to create a magnetic field, and the magnetic field
produces the desired work. The total or apparent power required by an inductive device is a composite of the
following:

Real Power (Measured in Kilowatts, kW)


Reactive Power, the non working Power caused by the magnetizing current, required to
operate the device (measured in kilovars, kVAr)

Reactive Power required by inductive loads increases the amount of Apparent Power (measured in kiloVoltamps,
kVA) in your distribution system. The increase in reactive and apparent Power causes the Power Factor to decrease.

Why Improve Your Power Factor?

Some of the benefits of improving Power Factor are as follow:


The utility bill will be lower. Low Power Factor requires an increase in the Electric Utility's Generation and
Transmission capacity to handle the Reactive Power component caused by inductive loads. Utilities usually
charge a penalty fee to customers with Power Factors less than 0.85. The penalty can be avoided and
rebate can be earned instead by increasing Power Factor to 0.999 LAG.

Electrical system's capacity will increase.

Reduction in kVA demands resulting in saving in power bill.

Reduction in current drawn, thereby ensuring lower load on electrical installation like transformers, cables,
switchgears and captive generating sets.

Enables connection of additional loads within the existing sanctioned load.

Reduction of voltage drop, thereby improving performance of electrical equipment/machinery.

No attention required for Operating & Maintenance.

Payback period normally within 6 months.

Improvement can be made from the smallest to the largest equipment.

Installation cost is nominal and simple, without disturbing normal production and plant operation.

www.ushapower.com
10
Usha Power
Shunt Capacitor

Harmonics
What is Harmonic?
Harmonics are produced in the operation of electric loads with non-linear voltage/current characteristics (e.g.
rectifiers and inverters for drives, welding apparatus and uninterruptible power supplies). Harmonics are sinusoidal
voltages and current with higher frequencies of a multiple of the 50 or 60 Hz line frequency. In low-voltage three-
phase systems the 5th and 7th harmonics are especially troublesome. Detuned PFC should be used in systems
subject to harmonics. This represents a series resonant circuit of Power Capacitor and reactor. The circuit is tuned
so that the series resonant frequency is below the lowest harmonics appearing in the system. This produces an
inductive response to all frequencies above the series resonant frequency, avoiding resonances with system
inductances. Depending on the selected series resonant frequency, part of the harmonic current is taken up by the
detuned PFC system. The remainder of the harmonic current flows into the super ordinate system. The use of
detuned PFC thus contributes to reducing voltage distortion through harmonics and lessens the disturbing effect on
proper operation of other electric loads.

Most international standards limit THD-V on LV side to 5%. However it has to be noted that in many grids these
levels are exceeded and even lower distortion, e.g. 3-4% THD-V can generate extreme over currents in case of
resonance condition.

Maximum over currents as specified under technical data of each series must not be exceeded.

Resonance must be avoided by appropriate panel design. Resonance may


cause very high over currents which can lead to Capacitor failures and worst
case to explosion and fire.

Fundamental
Pure Sinewave

Plus

3rd Harmonic

Equals

Harmonically
distorted waveform

11 www.ushapower.com
Usha Power
Shunt Capacitor

These filters are used when the main objective is not the reactive power compensation at the fundamental
frequency, but to reduce the harmonic distortion in the supply system.

Among the problems caused by Harmonics and which may make their suppression necessary,
are the following:

Interferences in telecommunications
Distortion on the mains voltage
Disturbances in Electronic Systems
Erratic operation of control and protection relays
Failures in transformers and motors, due to overheating caused by losses on the core.
Overheating of protective fuses to the point where a minor spike on the line causes them to blow.

It should be pointed out that the impedance of all the filters is capacitive below its tuning frequency, whereby
they also contribute, even if in a small scale, to the reactive power compensation at the fundamental frequency.

Installation of filters produces a modification on the topology of the electrical supply system. For this reason, the
design of filters must be done with regard to an accurate analysis and study of the whole system.

According to the application, there are different types of filters:


3rd Harmonic Filter HBF-T
Isolation Filter
Absorption Filter HAF
High pass Filter HPF
Active Filter SINAF

PFC focuses on the Power Flow (Cos φ) and the optimization of voltage stability by generating reactive Power-
to improve voltage quality and reliability of distribution level.

R S T
100

50

0
0 5 10 15 20 ms

-50

-100

www.ushapower.com
12
Usha Power
Shunt Capacitor

L.V. Capacitors
APP BOPP [FILM + FOIL]
The use of double sided hazy film, vacuum drawing and impregnation
with non toxic non- PCB bio degradable oil under very high vacuum
ensures an electrically stable Capacitor with excellent partial
discharge characteristics Film + Foil design with high grade steel
tank.

Specification:
Non Self Healing Type, IS 13585/1994/1998
Range:
5 to 50 kVAr in single unit and above in Bank
415/440/575/690/850/950 VAC. 50 Hz.
3 Ph, Delta Connected

Features
Hazy all Polypropylene Film +Foil Type
Non self healing Type
Operated at high temperature
Static Indoor type and oil filled, box type,
(CRCA Enclosure)Mild Steel
100% Oil filled Non P.C.B Non Toxic Oil
Highest inrush current withstanding capacity
Strongly recommended to use at extreme
high temperature environment.
99.99% Pure Aluminum Foil
Suitable for odd Harmonics load
Weather Proof Powder coating
Maintenance Free
Explosion Proof
Expected Life of Capacitors12- 15 Years
Losses < 0.2 /5 watts kVAr
No drifting in kVAr value upto limited period
No Oil Leakage and Maintenance free

Application
Fixed & Automatic P.F. Correction with Tuned & Detuned Filters
Indoor use filter applications
It is recommended to use at extreme high temperature
environment like Foundries & Steel Industries, Cement Industries,
Textile Industries.

Note for Harmonic Loads ,525 V Capacitors with Series


Reactors are recommended.

13 www.ushapower.com
Usha Power
Shunt Capacitor

Technical Details:
Three Phase 50Hz APP Type Capacitor
Standard Non Self healing Type ,IS 13585/1994/CPU

Capacitance tolerance ±5%

Out put kVAr 5 to 25 kVAr

Rated Current 6.17 Amp to 32.5 Amp

Operating Voltage 415 VAC

Rated Voltage 440 VAC (Other Voltages as request)

Frequency 50Hz

Temperature Range-Ambient temp category -25/D

Dielectric Losses <0.2 W/kVAr

Total Losses <0.50W/kVAr (inclusive discharge resitors)

Maximium Over Voltage in accordance with above Ucn+10%(upto 8hrs daily) Ucn+15%(upto 30mints daily),
standards Ucn+20%(upto5mints), Ucn+30%(upto 1mint)

Maximium over current 1.5 X IN

Peak Inrush Current 250 X In

Tolerance on Capacitance -5/+10%

Max THD in Voltage Voltage should not excceds above over voltage value

Max THD IN Current Cureent should not excceds above over current value

Discharge resistance As per IS 13585/1994/CPU

Connection Delta

Casing Box Type CRCA ENCLOSURE (Mild Steel)

Disconnection System All Phase - overpressure disconnector fuses

Dielectric 100 % oil filled Non PCB , Non toxic Oil

Voltage test between Terminals 2.15xUcn,AC,2 seconds


Voltage test between terminals to Case 3000VAC,2 seconds

Protection IP20

Permissible relative Humidity Max 95%

Expected Life 12-15 years

Altitude 2000 m above sea level

Impregnation Hazy All Polypropylene film + Foil Type

www.ushapower.com
14
Usha Power
Shunt Capacitor

Heavy Duty Double Dielectric


[MKP Capacitor]

Self Healing Capacitors with low losses Metalized Polypropylene


Dielectric without liquid impregnates. They have an over pressure
disconnection system that discounts the Capacitor in case of any
internal failure.

Specification:
Self Healing Type, IS 13340/13341/IEC : 60831-1

Voltage Range:
5 To 25 kVAr For 415/440V/525V/650 V Ac, 50Hz, 3Ph

Application
Fixed PF. Correction
Automatic P.F. Correction
Harmonic Filter System
Dynamic PFC systems

Features:
Metalized Polypropylene (MKP) Film Design.
Heavy Edge Metallised Multi layer MPP Film.
Box Type [Mild Steel]
Pressure Disconnector to Internal Elements
Better heat dissipation
Explosion proof design (Over pressure Disconnector)
Low losses due to advanced winding and zinc spray equipments.
Weather Proof
Powder Coating Design
Jelly impregnate for proper cooling
Low weight and compact volume
Working Expectancy Life 150,000 hrs

Applications: Inductive Loads, Steel Plants, Textiles,


Cement Industries, Building Complexes, APFC Panels,
Harmonic Filter Panels etc.Cement Industries

15 www.ushapower.com
Usha Power
Shunt Capacitor

Technical Details:
Three Phase 50Hz Double Dielectric Capacitor
Standard Self healing Type ,IS 13340/13341/IEC : 60831-1

Capacitance tolerance ± 5 % As per Standards

Out put kVAr 5 to 25 kVAr

Rated Current 6.2 A to 32.75 Amp

Rated Voltage 415/440 Vac ( other ratings on Request)

Frequency 50Hz

Temperature Range-Ambient temp category -25/D

Dielectric Losses <0.2 W/kVAr (Without Discharge Resistors)

Total Losses <0.50W/kVAr (inclusive discharge resitors)

Maximium Over Voltage in accordance with Ucn+10%(upto 8hrs daily) Ucn+15%(upto 30mints
above standards daily), Ucn+20%(upto5mints), Ucn+30%(upto 1mint)
Maximium over current 1.5 X IN

Peak Inrush Current 250 X In

Tolerance on Capacitance -5/+10%

Max THD in Voltage Voltage should not excceds above over voltage value

Max THD IN Current Cureent should not excceds above over current value

Discharge resistance External ,1 minutes,50 V

Connection Delta

Casing CRCA Square BOX Casing

Disconnection System Pressure Disconnector to interal elements.

Dielectric Jelly Field Type

Voltage test between Terminals 2.15xUcn, AC, 2 seconds

Voltage test between terminals to Case 3000VAC,2 seconds

Protection IP20

Permissible relative Humidity Max 95%

Expected Life 150000 operating hours

Altitude 2000 m above sea level

Impregnation Jelly/Oil Impregrnant

Enclosure Indoor Mounting

Mounting Position Vertical

Mounting & Earthing Vertical or Wall mounting

www.ushapower.com
16
Usha Power
Shunt Capacitor

Super Heavy Duty Type Capacitor


Self-Healing Capacitors fitted in a rectangular sheet steel plate
enclosure having discharge resistors connected to the terminals,
which are protected by the cover.

They are suitable for the individual compensation of inductive


loads and in the construction of small Automatic Capacitor Banks.

Application
Fixed PF. Correction
Automatic P.F. Correction
Filter Application System
Dynamic PFC
Tuned and Detuned Harmonic Filter

Specification:
Self Healing Type, IS 13340/13341/IEC : 60831-1

Voltage Range:
5 to 25 kVAr For 440V/525V/650 V Ac, 50Hz, 3Ph

Features:
Metalized Polypropylene (MKP) Film Design
Heavy Edge Metalized Multilayer MPP
CRCA enclosure Cylindrical Casing Design
Jelly/Oil impregnation given cooling effect
Explosion Proof Design
Low losses due to advanced winding and zinc spray
equipments.
Working Expectancy life 150,000 hours
Backed by German Technology

Applications: Inductive Loads, Steel Plants, Textiles,


Cement Industries, Building Complexes, APFC Panels,
Harmonic Filter Panels etc.Cement Industries

17 www.ushapower.com
Usha Power
Technical Details: Shunt Capacitor

Three Phase 50Hz Super Heavy Duty Type Capacitor


Standard Self healing Type ,IS 13340/13341/IEC : 60831-1

Capacitance tolerance ±5%

Out put kVAr 5 to 25 kVAr

Rated Current 65.5 Amp6.2 A to 32.75 Amp

Rated Voltage 415 / 440 Vac( other ratings on Request)

Frequency 50Hz

Temperature Range-Ambient temp category -25/D

Dielectric Losses <0.2 W/kVAr (Without Discharge Resistors)

Total Losses <0.50W/kVAr (inclusive discharge resitors)

Maximium Over Voltage in accordance with Ucn+10% (upto 8 hrs daily) Ucn+15% (upto 30 mints daily),
above standards Ucn+20% (upto 5 mints), Ucn+30% (upto 1mint)

Maximium over current 1.5 X IN

Peak Inrush Current 250 X In

Tolerance on Capacitance -5/+10%

Max THD in Voltage Voltage should not excceds above over voltage value

Max THD IN Current Cureent should not excceds above over current value

Discharge resistance External 1 minutes,50 v/ 3 minutes 75 V

Connection Delta

Casing Cylindrical (Aluminium Can Type)

Disconnection System All Phase - Over pressure Disconnector Fuses

Dielectric MPP Gas filled with Heavy Edge metalized multilayer MPP

Voltage test between Terminals 2.15 x Ucn, AC, 2 seconds

Voltage test between terminals to Case 3000VAC,2 seconds

Inrush Current 200 X IN

Protection IP20

Permissible relative Humidity Max 95%

Expected Life 150,000 Operating Hours

Altitude 2000 m above sea level

Impregnation Dry Gas filled

Enclosure IP00, On request IP54

Cooling Natural Air Cooled Casing temp max 60 c permitted on top of the Can.

Saftey Features Over Pressure Sensitive 3 Phase disconnector.

Mounting Position Random

Mounting & Earthing

www.ushapower.com
M12 X 16 mm threaded stud at bottom of the case with nut & Washer
18
Usha Power
Shunt Capacitor

Heavy Duty HEXL Type Capacitor


Application
Fixed PF. Correction
Automatic P.F. Correction
Harmonic Filter System

Specification:
Self Healing Type ,IS 13340/13341/IEC : 60831-1

Voltage Range:
5 To 25 KVAr For 440v/525VAC, 50Hz, 3PH

Features:
Cylindrical (Aluminium Can Type)
MPP, MKP, Gas, Oil, Jelly Filled Type
Heavy Edge Metalized Multilayer MPP/MKP, Losses <0.2 Watts/kVAr
Working Expectancy Life 50,000 Hours
Backed By German Technology
Metalized polypropylene (MKP) film design
Compact Cylindrical Al. can design
Jelly impregnation given cooling effect
Better heat dissipation
Explosion proof design (internal fuse protection)
Low losses due to advanced winding and zinc spray equipments.
Finger-touch proof terminal connectors.

Applications: All Industrial Loads, Rice Mills, Cold Storage

19 www.ushapower.com
Usha Power
Shunt Capacitor

Technical Details:
Three Phase 50Hz Heavy Duty HEXL Type Capacitor
Standard Self healing Type ,IS 13340/13341/IEC : 60831-1

Capacitance tolerance ± 5 % As per Standards

Out put kVAr 5 to 25 kVAr

Rated Current 6.2 A to 32.75 Amp

Rated Voltage 415 / 440 Vac( other ratings on Request)

Frequency 50Hz

Temperature Range-Ambient temp category -25/D

Dielectric Losses <0.2 W/kVAr (Without Discharge Resistors)


Total Losses <0.50W/kVAr (inclusive discharge resitors)

Maximium Over Voltage in accordance with Ucn+10%(upto 8hrs daily) Ucn+15%(upto 30mints daily),
above standards Ucn+20%(upto5mints), Ucn+30%(upto 1mint)

Maximium over current 1.8 X IN

Peak Inrush Current 250 X In

Tolerance on Capacitance -5/+10%


Max THD in Voltage Voltage should not excceds above over voltage value

Max THD IN Current Cureent should not excceds above over current value

Discharge resistance External 1 minutes,50 v/ 3 minutes 75 V

Connection Delta

Casing Cylindrical Aluminium Can

Disconnection System All Phase - overpressure disconnector fuses

Dielectric System MPP Gas filled

Voltage test between Terminals 2.15xUcn,AC,2 seconds

Voltage test between terminals to Case 3000VAC,2 seconds

Protection IP20

Permissible relative Humidity Max 95%

Expected Life 50,000 hours

Altitude 2000 m above sea level

Impregnation Inert Dry Gas

Enclosure IP00 ,On request IP54

Cooling Natural Air Cooled Casing temp max 60 c permitted on top of the Can.

Saftey Features Over Pressure Sensitive 3 Phase disconnector.

Mounting Position Random


Mounting & Earthing M12 X 16 mm threaded stud at bottom of the case with nut & Washer

www.ushapower.com
20
Usha Power
Shunt Capacitor

Standard Design Cylindrical Type Capacitor


Self-healing Capacitors fitted in a Cylindrical Aluminum
can having discharge resistors connected to the terminals
which are protected by the cover. They are suitable for
the individual compensation of inductive loads and in the
construction of small Automatic Capacitor Banks.

Specification:
Self Healing Type, IS 13340/13341/IEC : 60831-1

Voltage Range:
5 To 25 kVAr For 440V, 50Hz, 3Ph

Application:
Fixed PF. Correction
Automatic P.F. Correction
Filter Application System
Dynamic PFC
Tuned and Detuned Harmonic Filter

Features:
Cylindrical (Aluminium Can Type)
Working Expectancy Life:- 100,000 Hours.
Explosion Proof Design
Gas Filled
Pressure Disconnector
Heavy Edge Metalized Multi Layer MPP Film/ MKP
Expectancy Life 50,000 hours
Backed by German Technology
Low losses due to advanced winding and Zinc Spray
Equipments.

Applications: Inductive Loads, Steel Plants, Textiles,


Cement Industries, Building Complexes, APFC Panels,
Harmonic Filter Panels etc.Cement Industries

21 www.ushapower.com
Usha Power
Technical Details: Three Phase 50Hz Standard Shunt Capacitor

Design Cylindrical Type Capacitor


Standard Self healing Type ,IS 13340/13341/IEC : 60831-1

Capacitance tolerance ± 5 % As per Standards

Out put kVAr 50 kVAr

Rated Current 65.5 Amp

Operating Voltage 415 Volt AC

Rated Voltage 525 Volt AC

Frequency 50Hz

Temperature Range-Ambient temp category -25/D

Dielectric Losses <0.2 W/kVAr (Without Discharge Resistors)


Total Losses <0.50W/kVAr (inclusive discharge resitors)

Maximium Over Voltage in accordance with Ucn+10%(upto 8hrs daily) Ucn+15%(upto 30mints daily),
above standards Ucn+20%(upto5mints), Ucn+30%(upto 1mint)

Maximium over current 1.5 X IN

Peak Inrush Current 250 X In

Tolerance on Capacitance -5/+10%


Max THD in Voltage Voltage should not excceds above over voltage value

Max THD IN Current Cureent should not excceds above over current value

Discharge resistance As per IS 13340

Connection Delta

Casing Cylindrical Aluminium Can

Disconnection System Pressure Disconnector

Dielectric Jelly Field Type

Voltage test between Terminals 2.15xUcn,AC,2 seconds

Voltage test between terminals to Case 3000VAC,2 seconds

Protection IP20

Permissible relative Humidity Max 95%

Expected Life 50000 hours

Altitude 2000 m above sea level

Impregnation MPP/MKP Gas, Oil, Jelly filled Type

Enclosure IP00 ,On request IP54

Cooling Natural Air Cooled Casing temp max 60 c permitted on top of the Can.

Saftey Features Over Pressure Sensitive 3 Phase disconnector.

Mounting Position Random


Mounting & Earthing M12 X 16 mm threaded stud at bottom of the case with nut & Washer

www.ushapower.com
22
Usha Power
Shunt Capacitor

H.V. Capacitors
Application:
Individual PF Correction
Dynamic PFC
Individual PF Correction on three Phase Motor
Individual PF Correction of Power Transformers
Individual PF Correction of group Power Factor correction
Central Power Factor Correction of all Industrial /Inductive Loads
Fixed Type Capacitors Bank
Filter Application System
SVC Application

Features:
All film Dielectric is used and consist of Polypropylene in the form of
biaxial oriented film, hazy on both sides, and in two or three layers
with laser cut Aluminum Foil for the electrodes.
The Capacitors are impregnated with a NON –PCB base fluid.
Dielectric Loss approx 0.1W/kVAr
Capacitors are designed ,manufactured and tested to meet the
requirements of IS: 13925-1994,IEC-60871,
Voltage Range – 2.4 kV- 24kV
Frequency - 50 Hz /60 Hz
Corrosion Protection
Maximum Permissible Current [Capacitors unit shall be switched for
continuous operation at an RMS current of 1.30 times the current that
occurs at rated sinusoidal voltage and rated frequency, excluding
transients].
Temp range: 5° C – 55 ° C
Decreasing Voltage drop
Reduces network losses.
Increase Voltage Stability.
Improved Power Quality.
Welded bushing and solid terminal stud prevents fluid leaks.
Folded foil electrodes reduce partial discharge generation.
Extended foils are soldered, providing superior internal connections.
Superior paint system with oven cured process.
Impregnation process under vacuum to ensure lowest possible
humidity content.
Maximum output 1000 kVAr Single phase
Suitable for Indoor/Outdoor applications.
Superior electrical performance
Specification: IS: Non Self Healing Type, ISI 13925-1994, IEC-60871,
Applications: All Working Loads, Harmonic Voltage Range: 2.2 kV- 24 kV
Filter, APFC Wind Mill, Solar Power,
Steel Plants etc.

23 www.ushapower.com
Usha Power
Shunt Capacitor

Technical Details:
Three Phase 50Hz HV Capacitors
Range 50kVAr to 1000 kVAr in single unit and Banking up to as per requirements.

Standards IS 13925 (part 1-1998/ IEC-60871 (Part-1-1997)

Rated Voltage 1.9kv-24kv

Rated Frequency 50/60 Hz

Maximum Permissible VOLTAGE 110%for 8/12 H in every 24 H

Over Current 130% of rated current

Capacitance Tolerance -5% to +15%

Temperature rise Less than 10 C above ambient

Casing. C.R.C.A/Mild steel square box casing.

ENCL Indoor mounting

Expected Life >2,00,000 Hrs

Ambient Temperature -25 C to +25 C

Cooling Natural air cooled / PXE Oil Cooled.

Dielectric All film+ Foil (APP Type)

Impregnation Non-toxic, Non-Chlorinated, Bio-Degradable Oil

Safety Internal/External Fuses

www.ushapower.com
24
Usha Power
Shunt Capacitor

Series Reactor LV
For harmonic loads 525 V capacitors with series reactor are
recommended, which also are available in USHA POWER.

Range
Output up to 100 kVAr
Filter factor 5.67 %, 7%, 14 %
Rated Voltage - 440 V, 525 V, 690 V

Type
Tuned & Detuned, Aluminum / Copper wound- Iron Core Dry
Type.

Features
Limiting inrush current during switching
Limiting resonance and protection of Capacitor Banks
Harmonic Banks
Harmonic Filtration
Low losses & low noise level
For Triplen and Non-Triplen Harmonic suppression though
PF Capacitors.
Operating ambient temperature -10 to +50 Deg C
Storage temperature -10 to +75 Deg C
Supply frequency: 47Hz to 53Hz
Current : Continuous RMS value: 150% of the rated current

Series
Reactor LV

25 www.ushapower.com
Usha Power
Shunt Capacitor

Series Reactor MV/HV


Cast Resin Insulation Technology is sometimes necessary for
Medium Voltage (MV) Reactors, Vacuum Pressure Impregnation
(VPI) technology for the common medium- and low Voltage
applications. Dry-type reactors are fundamental components in
the power quality management, losses reduction, cost alignment
and signal shaping could be translated in an overall cost reduction
for the equipped applications.

Features
Wide Range of Power Ratings, from 1 kVAr to several MVAr
Single-Phase or Three-Phase
Voltages up to 36 kV
Special designs for high frequency applications (up to 25 kHz)
Different types of cooling:
AN (air natural), AF (air forced) or WF (water forced)
Any type of enclosure

www.ushapower.com
26
Usha Power
Shunt Capacitor

Water Cooled Capacitors


Medium and high frequency Water Cooled Capacitors are
specially designed and manufactured for designed for
inductive heat generating plants operating at frequencies
as per the furnace design. These Capacitors are designed
to comply with the specific requirements of each customer.
Most of these Capacitors provide for step changes in kVAr
by virtue of terminated sections within each unit. This
allows for the tuning of the circuit for changing inductive
loads.

Application: - Specially designed to accommodate high


capacity to be easily used for matching circuit of high
frequency induction furnace device.

Guaranteed Technical Particulars

Output: Up to 6000kVAr
Voltage: Up to 4000V
Frequency: 50 Hz – 1000 Hz
Construction: Dead/ Life Case
Cooling Media: D.M.water
Tapping: As desired by Customers

27 www.ushapower.com
Usha Power
Shunt Capacitor

Thyristor Switch
We provide our clients with an array of high performance
Thyristor Switch. These are semi conducting device with 4
layers of alternating n and p material. Our range acts as a
switch carrying out the current pulse constantly for as long as
they are forward biased. Thyristor Switches broadly find its
usage wherever high voltage and current are concerned.
These are also used to manage alternating currents to change
its polarity that causes automatic switch off of the device.

Features
High Voltage and Ampere ratings
Unidirectional and Bidirectional transient Voltage
protection
Automatically triggered "off" for specified period of time
RoHS compliant
Glass-Passivated Junctions
High voltage capability up to 1000 V
High surge capability up to 950V

Application
Home appliances - lighting, heating, temperature
control, alarm activation, fan speed

Electrical tools - for controlled actions such as motor


speed, stapling event, battery charging

Outdoor equipment - water sprinklers, gas engine


ignition, electronic displays, area lighting, sports
equipment, physical fitness.

www.ushapower.com
28
Usha Power
Shunt Capacitor

PFC Sizing
Capacitor (kVAr) Selection Chart
Coefficient K by which to multiply the active energy consumed in kW in order to determine the kVAr necessary for correcting the Power
Factor (cosφ0is the initial PF, cosφ1, is the PF obtainable with correction). Recommended final cosφ= 0.95 (greyed column below).

Coefficient K
Initial Value Cosφ (PF Obtainable)
tgφ cosφ 0.85 0.86 0.87 0.88 0.89 0.90 0.91 0.92 0.93 0.94 0.95 0.96 0.97 0.98 0.99 1.00
3.18 0.30 2.560 2.586 2.613 2.640 2.667 2.695 2.724 2.754 2.785 2.817 2.851 2.888 2.929 2.977 3.037 3.180
3.07 0.31 2.447 2.474 2.500 2.527 2.555 2.583 2.611 2.641 2.672 2.704 2.738 2.775 2.816 2.864 2.924 3.067
2.96 0.32 2.341 2.367 2.394 2.421 2.448 2.476 2.505 2.535 2.565 2.598 2.632 2.669 2.710 2.758 2.818 2.961
2.86 0.33 2.241 2.267 2.294 2.321 2.348 2.376 2.405 2.435 2.465 2.498 2.532 2.569 2.610 2.657 2.718 2.861
2.77 0.34 2.146 2.173 2.199 2.226 2.254 2.282 2.310 2.340 2.371 2.403 2.437 2.474 2.515 2.563 2.623 2.766
2.68 0.35 2.057 2.083 2.110 2.137 2.164 2.192 2.221 2.250 2.281 2.313 2.348 2.385 2.426 2.473 2.534 2.676
2.59 0.36 1.972 1.998 2.025 2.052 2.079 2.107 2.136 2.166 2.196 2.229 2.263 2.300 2.341 2.388 2.449 2.592
2.51 0.37 1.891 1.918 1.944 1.971 1.999 2.027 2.055 2.085 2.116 2.148 2.182 2.219 2.260 2.308 2.368 2.511
2.43 0.38 1.814 1.841 1.867 1.894 1.922 1.950 1.979 2.008 2.039 2.071 2.105 2.143 2.184 2.231 2.292 2.434
2.36 0.39 1.741 1.768 1.794 1.821 1.849 1.877 1.905 1.935 1.966 1.998 2.032 2.069 2.110 2.158 2.219 2.361
2.29 0.40 1.672 1.698 1.725 1.752 1.779 1.807 1.836 1.865 1.896 1.928 1.963 2.000 2.041 2.088 2.149 2.291
2.22 0.41 1.605 1.631 1.658 1.685 1.712 1.740 1.769 1.799 1.829 1.862 1.896 1.933 1.974 2.022 2.082 2.225
2.16 0.42 1.541 1.567 1.594 1.621 1.648 1.676 1.705 1.735 1.766 1.798 1.832 1.869 1.910 1.958 2.018 2.161
2.10 0.43 1.480 1.506 1.533 1.560 1.587 1.615 1.644 1.674 1.704 1.737 1.771 1.808 1.849 1.897 1.957 2.100
2.04 0.44 1.421 1.448 1.474 1.501 1.529 1.557 1.585 1.615 1.646 1.678 1.712 1.749 1.790 1.838 1.898 2.041
1.98 0.45 1.365 1.391 1.418 1.445 1.472 1.500 1.529 1.559 1.589 1.622 1.656 1.693 1.734 1.781 1.842 1.985
1.93 0.46 1.311 1.337 1.364 1.391 1.418 1.446 1.475 1.504 1.535 1.567 1.602 1.639 1.680 1.727 1.788 1.930
1.88 0.47 1.258 1.285 1.311 1.338 1.366 1.394 1.422 1.452 1.483 1.515 1.549 1.586 1.627 1.675 1.736 1.878
1.83 0.48 1.208 1.234 1.261 1.288 1.315 1.343 1.372 1.402 1.432 1.465 1.499 1.536 1.577 1.625 1.685 1.828
1.78 0.49 1.159 1.186 1.212 1.239 1.267 1.295 1.323 1.353 1.384 1.416 1.450 1.487 1.528 1.576 1.637 1.779
1.73 0.50 1.112 1.139 1.165 1.192 1.220 1.248 1.276 1.306 1.337 1.369 1.403 1.440 1.481 1.529 1.590 1.732
1.69 0.51 1.067 1.093 1.120 1.147 1.174 1.202 1.231 1.261 1.291 1.324 1.358 1.395 1.436 1.484 1.544 1.687
1.64 0.52 1.023 1.049 1.076 1.103 1.130 1.158 1.187 1.217 1.247 1.280 1.314 1.351 1.392 1.440 1.500 1.643
1.60 0.53 0.980 1.007 1.033 1.060 1.088 1.116 1.144 1.174 1.205 1.237 1.271 1.308 1.349 1.397 1.458 1.600
1.56 0.54 0.939 0.965 0.992 1.019 1.046 1.074 1.103 1.133 1.163 1.196 1.230 1.267 1.308 1.356 1.416 1.559
1.52 0.55 0.899 0.925 0.952 0.979 1.006 1.034 1.063 1.092 1.123 1.156 1.190 1.227 1.268 1.315 1.376 1.518
1.48 0.56 0.860 0.886 0.913 0.940 0.967 0.995 1.024 1.053 1.084 1.116 1.151 1.188 1.229 1.276 1.337 1.479
1.44 0.57 0.822 0.848 0.875 0.902 0.929 0.957 0.986 1.015 1.046 1.079 1.113 1.150 1.191 1.238 1.299 1.441
1.40 0.58 0.785 0.811 0.838 0.865 0.892 0.920 0.949 0.979 1.009 1.042 1.076 1.113 1.154 1.201 1.262 1.405
1.37 0.59 0.749 0.775 0.802 0.829 0.856 0.884 0.913 0.942 0.973 1.006 1.040 1.077 1.118 1.165 1.226 1.368
1.33 0.60 0.714 0.740 0.767 0.794 0.821 0.849 0.878 0.907 0.938 0.970 1.005 1.042 1.083 1.130 1.191 1.333
1.30 0.61 0.679 0.706 0.732 0.759 0.787 0.815 0.843 0.873 0.904 0.936 0.970 1.007 1.048 1.096 1.157 1.299
1.27 0.62 0.646 0.672 0.699 0.726 0.753 0.781 0.810 0.839 0.870 0.903 0.937 0.974 1.015 1.062 1.123 1.265
1.23 0.63 0.613 0.639 0.666 0.693 0.720 0.748 0.777 0.807 0.837 0.870 0.904 0.941 0.982 1.030 1.090 1.233
1.20 0.64 0.581 0.607 0.634 0.661 0.688 0.716 0.745 0.775 0.805 0.838 0.872 0.909 0.950 0.998 1.058 1.201
1.17 0.65 0.549 0.576 0.602 0.629 0.657 0.685 0.714 0.743 0.774 0.806 0.840 0.877 0.919 0.966 1.027 1.169
1.14 0.66 0.519 0.545 0.572 0.599 0.626 0.654 0.683 0.712 0.743 0.775 0.810 0.847 0.888 0.935 0.996 1.138
1.11 0.67 0.488 0.515 0.541 0.568 0.596 0.624 0.652 0.682 0.713 0.745 0.779 0.816 0.857 0.905 0.966 1.108
1.08 0.68 0.459 0.485 0.512 0.539 0.566 0.594 0.623 0.652 0.683 0.715 0.750 0.787 0.828 0.875 0.936 1.078
1.05 0.69 0.429 0.456 0.482 0.509 0.537 0.565 0.593 0.623 0.654 0.686 0.720 0.757 0.798 0.846 0.907 1.049
1.02 0.70 0.400 0.427 0.453 0.48 0.508 0.536 0.565 0.594 0.625 0.657 0.692 0.729 0.770 0.817 0.878 1.020
0.99 0.71 0.372 0.398 0.425 0.452 0.480 0.508 0.536 0.566 0.597 0.629 0.663 0.700 0.741 0.789 0.849 0.992
0.96 0.72 0.344 0.370 0.397 0.424 0.452 0.480 0.508 0.538 0.569 0.601 0.635 0.672 0.713 0.761 0.821 0.964
0.94 0.73 0.316 0.343 0.370 0.396 0.424 0.452 0.481 0.510 0.541 0.573 0.608 0.645 0.686 0.733 0.794 0.936
0.91 0.74 0.289 0.316 0.342 0.369 0.397 0.425 0.453 0.483 0.514 0.546 0.580 0.617 0.658 0.706 0.766 0.909
0.88 0.75 0.262 0.289 0.315 0.342 0.370 0.398 0.426 0.456 0.487 0.519 0.553 0.590 0.631 0.679 0.739 0.882
0.86 0.76 0.235 0.262 0.288 0.315 0.343 0.371 0.400 0.429 0.460 0.492 0.526 0.563 0.605 0.652 0.713 0.855
0.83 0.77 0.209 0.235 0.262 0.289 0.316 0.344 0.373 0.403 0.433 0.466 0.500 0.537 0.578 0.626 0.686 0.829
0.80 0.78 0.183 0.209 0.236 0.263 0.290 0.318 0.347 0.376 0.407 0.439 0.474 0.511 0.552 0.599 0.660 0.802
0.78 0.79 0.156 0.183 0.209 0.236 0.264 0.292 0.320 0.350 0.381 0.413 0.447 0.484 0.525 0.573 0.634 0.776
0.75 0.80 0.130 0.157 0.183 0.210 0.238 0.266 0.294 0.324 0.355 0.387 0.421 0.458 0.499 0.547 0.608 0.750
0.72 0.81 0.104 0.131 0.157 0.184 0.212 0.240 0.268 0.298 0.329 0.361 0.395 0.432 0.473 0.521 0.581 0.724
0.70 0.82 0.078 0.105 0.131 0.158 0.186 0.214 0.242 0.272 0.303 0.335 0.369 0.406 0.447 0.495 0.556 0.698
0.67 0.83 0.052 0.079 0.105 0.132 0.160 0.188 0.216 0.246 0.277 0.309 0.343 0.380 0.421 0.469 0.530 0.672
0.65 0.84 0.026 0.053 0.079 0.106 0.134 0.162 0.190 0.220 0.251 0.283 0.317 0.354 0.395 0.443 0.503 0.646
0.62 0.85 0.026 0.053 0.080 0.107 0.135 0.164 0.194 0.225 0.257 0.291 0.328 0.369 0.417 0.477 0.620
0.59 0.86 0.027 0.054 0.081 0.109 0.138 0.167 0.198 0.230 0.265 0.302 0.343 0.390 0.451 0.593
0.57 0.87 0.027 0.054 0.082 0.111 0.141 0.172 0.204 0.238 0.275 0.316 0.364 0.424 0.567
0.54 0.88 0.027 0.055 0.084 0.114 0.145 0.177 0.211 0.248 0.289 0.337 0.397 0.540
0.51 0.89 0.028 0.057 0.086 0.117 0.149 0.184 0.221 0.262 0.309 0.370 0.512
0.48 0.90 0.029 0.058 0.089 0.121 0.156 0.193 0.234 0.281 0.342 0.484
0.46 0.91 0.030 0.060 0.093 0.127 0.164 0.205 0.253 0.313 0.456
0.43 0.92 0.031 0.063 0.097 0.134 0.175 0.223 0.284 0.426

29 www.ushapower.com
Usha Power
Shunt Capacitor

Example:
If in an Electricity Bill,

Contract Demand (CD) = 250 kVA


Maximum Demand (MD) = 220 kVA
Consider the Power Factor (PF) = 0.92
Then,
Required kVAr (Qc) = CD/MD x Existing Pf x Multiplying Factor (from table)
= 250 x 0.92 x 0.426= 97.98 (assume 100 kVAr)
For the Improvement of the Power Factor from 0.92 to Unity. We read the factor 0.426 from the table

NOTE: The greater amount of kVA should be taken into consideration for calculation, i.e.
If MD > CD then, kVA of MD should be calculated or vice versa.

Correcting the Power Factor of MV/ LV Transformer


It is always a good idea to ensure a Power Factor correction for MV/ LV transformers, since even when they are
operating load less (e.g. during the night) they absorb reactive power, which must be compensated.
The exact Capacitor Power necessary may be calculated using the formula below:

Q= l0%.Pn / 100

L0 = load less current


(Specified by the transformer manufacturer)
Pn = rated power of the transformer
Alternatively, if the required data is not available, you can refer to the table below, which differentiates among
types of transformers with NORMAL losses.

Power Oil Transformer Resin Transformer Power Oil Transformer Resin Transformer
Transformer kVa kVAr kVAr Transformer kVa kVAr kVAr

10 1 1,5 500 15 10

20 2 1,7 630 17,5 12,5

50 4 2
800 20 15

75 5 2,5
1000 25 17,5

100 5 2,5 1250 30 20

160 7 4 1600 35 22

200 7,5 5 2000 40 25

250 8 7,5 2500 50 35

3150 60 50
315 10 7,5

400 12,5 8

www.ushapower.com
30
Usha Power
Shunt Capacitor

Our Focussed
Market Segment

Cement Industries Steel Industries

Aluminium Industries Power Generation Plants

FMCG Textile Industries

www.ushapower.com
32
Usha Power
Shunt Capacitor

A Small List of Our


Satisfied Customers

33 www.ushapower.com
Usha Power
Shunt Capacitor

an exciting
‘ a successful past

future

www.ushapower.com
Global Presence
Europe Asia
North America

India

Africa
South America

Australia

60
882 18
1
05
+9

24
5

hour
Head/Registered Office
A-215/09, Ground Floor,
Street No. 1,
Raipur Office Works
“CHAWLA COMPLEX” Vikas C-2, Maruti Enclave, Tatibandh, Raipur, Kolkata, Pune, Noida
Marg, Shakarpur, New Delhi – Chattisgarh-492 099 (M) +91 93311 60677
110092, India (M) +91 93001 02456
Email: cg@ushapower.com Other Offices
Phone: (011) 22453829 Ahmedabad: +91 9332356984
Mobile: +91 93119 86643 Guwahati: +91 9331460669
Mobile: +91 88260 18055 Jaipur: +91 9311986643
Pune: +91 8698804924
Email: sales@ushapower.com
delhi@ushacapacitor.com
+91 9830939253 www.wingsmedia.co.in

www.ushapower.com

Вам также может понравиться