Published by Megger
July 2019
ELECTRICAL
TESTER The industry’s recognised information tool
SVERKER 900
Relay and Substation Test System
The toolbox for substation 3-phase testing
Three currents and four voltages
Stand-alone functionality
Rugged and reliable for field use
Generation of 900 V and 105 A in single phase mode
Meet IDA:
An interview with Megger’s
Dr. Peter Werelius
AB. When we discussed a name for our first
Jill Duplessis - Global technical marketing
product, we talked about a few requirements:
manager and Editor
preferably it should be a name as well as an
acronym and ideally the acronym should work
On September 27, 2018, IEEE-SA Standards Board
in Swedish and in English. My now grown
approved IEEE C57.161-2018 – Guide for Dielectric
up baby girl, born in 1995, is named Ida and
Frequency Response test. This work follows that of
besides being very personal to me, her name
other standards organizations, such as CIGRE’s TB
met our other requirements. In Swedish, it was
254, TB 414 and TB 445 – all technical brochures
IsolationsDiagnostikApparat, which was later
that address aspects of dielectric frequency
changed to IsolationsDiagnostikAnalysator, and
response (DFR) testing.
in English it was Insulation Diagnostic Apparatus
A Dielectric Frequency Response (DFR) test is an and later Insulation Diagnostic Analyzer. When Pax
insulation health assessment tool that is more Diagnostics took over the IDA from GE-Programma
discriminating than traditional dielectric screening in 2006, the instrument’s name was modified
tests such as power factor/dissipation factor. slightly to IDAX (Insulation Diagnostic Analyzer
DFR testing can be used, for example, to assess by Pax). Both IDA and IDAX are pronounced as
the insulation health of transformers, bushings, names, not acronyms.
instrument transformers and cables. In a complex
insulation system such as that of a transformer,
DFR testing provides a moisture assessment of the A true frequency domain
solid insulation, conductivity of the liquid insulation
method that speeds
and information about the thermal behavior of the
insulation system. up measurement is
accomplished by applying
With increasing attention being paid to the DFR
method, it seemed a very appropriate time for several frequencies Baby Ida, the eponymous hero of the IDAX
Megger’s Jill Duplessis to talk to Dr Peter Werelius simultaneously, and
who developed the first commercially available extracting measurement JD: There has been some talk about the need to compensation algorithm, this may rightly cause
DFR test set for field use. Here’s what he had compensate DFR test results for ageing byproducts; discerning users to grow uneasy.
data from the applied
to say. otherwise, in some cases, moisture results may be
frequencies simultaneously misleading. For perceptive users, this “red herring”
How can a user go about validating an instrument
JD: Thanks Peter. I’d like to begin with manufacturer’s database? Also, is there a more
congratulations to you and your peers for your of sorts puts focus squarely back on the database. pragmatic approach to take when a user has
collaborative work on the newly published IEEE JD: Can you tell us a little about the history Fundamentally, DFR analysis and the results it’s
legitimate concerns that aging of the asset may be
guide! Back in 1996, the first commercially of the IDAX instruments and how they have skewing moisture assessment results?
intended to provide, such as moisture content in
available DFR instrument designed for field use, developed over the years since the first model solid insulation and oil conductivity, is based on PW: The fact that aging byproducts, or more
which is known today as the Megger IDAX, was was introduced? fitting the measured DFR curve to its best match specifically low molecular weight acids, affect DFR
introduced. As its developer, what advice would
in a database of curves. The test software does results has been known by the industry for more
your “scientist self” of today give to your “scientist PW: The initial development of the DFR
this through mathematical modeling – adjusting than 10 years ( See: Dielectric response of mineral
self” 22 years ago? instrument was part of my Ph.D. project that
parameters that affect the shape of the model oil impregnated cellulose and the impact of aging,
began in early 1992 at KTH (Royal institute of
PW: I am fortunate that my personal guiding curve until the software finds the best match. The D.Linhjell et. al. IEEE Transaction of Dielectrics and
Technology, Stockholm). In 1994, Björn Jernström
principles have served the development of the DFR parameters include: Electrical Insulation, 2007). Our database and
joined me and helped me to turn my student set-
technology well. So I would offer to others my others are typically applied without any attempt
up into a practical instrument for field use. Late in Relation of solid (cellulose) vs. liquid (oil)
firsthand experience that being generous to my to directly compensate the results. One database
1996, we sold the first commercial unit, IDA#1, insulation;
first and subsequent business partners (with whom attempts to compensate for the effect of aging
to Vattenfall, Sweden. The second unit, IDA#2,
I founded WaBtech and later Pax Diagnostics) and products by using measured oil conductivity but
which we delivered in spring 1997 to ABB Inc. in moisture in solid insulation;
being honest and helpful to my former employer in my opinion this approach is not successful.
the USA, was already significantly changed from
along the way as well as early customers has and oil conductivity. It was reported in the paper referenced above
IDA#1, so that it would fit into a case about half
come back to me in unimaginably, positive ways. that low molecular weight acids influence DFR
My partners, my employees at that time, my the size of the previous one. After Programma I think that it is important for users to recognize
response, but high molecular weight acids, which
former employer GE Programma, Megger, early Electric acquired WaBtech in late 1998, the IDA that there is not one universal database shared by
also can affect oil conductivity, do not affect the
customers, and KTH (Royal Institute of Technology) 200 instrument was developed and released in all instrument manufacturers. When you acquire
DFR response.
have been very committed and supportive. 2000. IDAX 206 followed (2006) and IDAX 300 a DFR instrument, you are selecting a database.
entered the market in 2008. At about this time, The database determines the accuracy of moisture In my opinion, the influence of low molecular
JD: I was really moved when I learned of the
competitors started to appear. Since then, we have assessment results. If differences that are observed weight acids is not a big problem. For dry
origin of the name “IDAX”. I understand that it is insulation, the DFR interpretation will give dry
improved the hardware, software and digital signal in moisture assessments using different DFR
quite personal to you. Can you explain? insulation. If the insulation is moderately moist,
processing algorithms. An important milestone instruments (or in results from a DFR instrument as
PW: Björn Bengtsson, who is now Björn was the introduction of the 2000V peak amplifier compared to other moisture assessment tools) are say with moisture content of 2%, the level of low
Jernström, and I were the co-founders of WaBtech accessory in 2011. explained away as being due to some undefined Continued on page 4...
The first commercially available DFR instrument designed for field use as a result of Peter Werelius’ Dr. Peter Werelius is the man behind IDAX – the
Ph.D. project, known today as the Megger IDAX, was introduced in 1996 The Megger IDAX today first field instrument for Frequency Domain
Spectroscopy (FDS) measurements.
(1,400 V RMS/2,000 V peak) in these instances every time data is needed, an alternate means and in some cases, this introduces quite large
will improve the measurement accuracy and is to determine an insulation’s equivalent behavior errors. Fortunately, by using our knowledge of Roland Eriksson, and later my colleagues and I
recommended. And, referring back to your earlier at a baseline temperature of 20°C is extremely DFR interpretation and the fact that modern made was to take DFR testing out of the laboratory
question, using a higher test voltage also makes valuable. A lot of information about an insulation’s power factor instruments can sweep over a range into the field. As you say, I have remained – and
it possible to successfully use multi-frequency thermal behavior can be accessed from DFR test of frequencies, we can now determine a much still remain – very closely involved with DFR
measurements to shorten measurement times in results. Can you explain a little more about this? more accurate temperature correction factor by testing and I am delighted to see how widely the
medium interference conditions. carrying out a limited frequency sweep on the
PW: The DFR interpretation used in IDAX – techniques that my colleagues and I devised and
and in other instruments – is based on the so actual test object.
JD: No discussion about insulation is complete developed are now being used. Of course, we no
without addressing the important topic of called master curve technique, where the DFR longer have the field to ourselves, but they do say
JD: From what you’ve told us, Peter, it’s apparent
temperature. It is widely understood that the response of the impregnated cellulose material that imitation is the sincerest form of flattery. With
that you were a true pioneer of DFR testing and
electrical characteristics of insulating materials can be shifted to another temperature by simply
that you’re still a very active innovator in the field. this in mind, I’m sincerely flattered by how many
changing the frequency axis based on the
change with temperature. Since diagnostic Is this a valid assessment? of our ideas other instrument manufacturers have
temperature difference while keeping the curve
tests on insulation rely on detecting changes in now adopted!
shape unchanged. The analysis is then performed PW: It’s a good summary, but it’s only fair to
the material(s)’s electrical characteristics, it is
at actual measurement temperature, e.g. 32°C.
important that only data that has been obtained acknowledge that my early work on DFR testing JD: Thank you for your time, Peter. I know you’re
at the same temperature be compared. This way, However, network frequency (50/60 Hz) power built on work that had already been carried out very busy but I’m sure your time has been well
any change in the measured electrical parameters factor measurements have traditionally been by others, notably by A K Jonscher in the UK and used and readers will be fascinated by the insights
can be attributed to a change in the state of the corrected to 20°C by using an approximate by Professor Uno Gäfvert, Dr. Bo Nettelblad and
you’ve given us into DFR testing past and present.
material and not a change in temperature. Since correction factor. It is well-known that this Kenneth Johansson in Sweden. The big advance
it is not practical to wait for same conditions correction factor depends on insulation status, our research group at KTH, headed by Professor PW: It’s a pleasure!
Exclusive Railway
Solution Catalogue
now available!
and tions
est n
al t nt solu statio
tric b
Elec sureme and Su Sca
mea ailway
n th
Pro e QR
R s tect co
for cation
ion de to
Vid w
eos atch
li
App
wit R
h S ailwa
MR y
T1
Sca
n th
eQ
R
Rail code
wa for
yC
ata soft co
log
ue py of
Sca
n th
Me e
gge QR co
r Clu de to
bM a
em pply
bers for
hip
Me
gg
211, er In
C dia
T: +9 rystal Pa Priv
1 22 ra ate
2674 dise M Lim
ite
0468 all, O
The
wor | E: ff Ve d
mar er
d “M
egge com a Desai
ms.
Cop
yrig
r” is indi Road, A
ht © a re a@m nd
gist
ered egge heri (W
2019 r.com ),
trad
emar | W: Mumba
ww i
k. w.m - 400
egge 05
r.com 3, India.
1
/IN/V
D/EV
RE
/CR/
Y/CT
25/S
1812
http://bit.ly/RailwayCatalogue
This arc shows up as a pattern change in the Evolution of the Surge Test for finding insulation faults, and it opened up
Mike Teska - Product Line Manager surge waveform. numerous possibilities for improving insulation
Surge testing of motor coils has been an industry
testing equipment as well as insulating methods.
The surge test is performed with an impulse practice since 1926, when J.L. Rylander published
For many years, predictive maintenance and motor Even in these early days of surge testing, the
generator with a display that continuously shows “A High Frequency Voltage Test for Insulation of
reliability experts have debated the merits of surge the surge waveform. The surge waveform is benign nature of the test was stated in an article
Rotating Electrical Apparatus” in Transactions
testing. Questions about the benefits and findings the voltage present across the test leads of the written by D.J. Reynolds, R.J. Alke, and L.W.
of the AIEE. In 1926, an indication of a turn-to-
of the test have fuelled heated discussions on instrument during the test. The indication of turn insulation failure was a drop of coil voltage Buchanan of Westinghouse: “Because the energy
forums and in boardrooms around the world. a turn-to-turn fault is a rapid shift to the left or amplitude. This amplitude was determined by a of the surge is extremely limited, the current
Some in the motor reliability community think that a decrease in amplitude of the waveform. The vacuum tube rectifier circuit using an apparatus through the faulty insulation is so small that no
the very process of finding insulation weakness observed waveform is directly related to the coil’s the size of a large workbench with rotating spark severe burning occurs at the point of weakness.”
in an electric motor by surge testing damages inductance. In effect, the coil becomes one of two gaps for switches and large step-up transformers With the amount of testing and information
the remaining dielectric insulation so the motor elements in a tank circuit. This circuit is a LC-type, to charge large high-voltage capacitors. As gathering that Westinghouse was doing, one
will not continue to operate. Others believe that made up of the coil’s inductance (L) and the surge time wore on, there was a need for a compact, would think that they would not make this
testing above operating voltage is absolutely tester’s internal capacitance (C). portable machine that would produce a high statement lightly.
necessary to verify insulation integrity, and does voltage at relatively low currents. At this time,
The inductance (L) of a coil is determined by its There have been many advances in high-voltage
not precipitate insulation weaknesses. surge technology was not new; however, the
geometry (number of turns of wire) and the type testing since the 1980s. Broad markets and
So what is the truth? Can surge testing, done of iron core it rests in. The frequency of the wave machines used for transformer testing were technology developments in the electronics
properly, help industry reduce costly downtime, pattern is determined by: expensive and cumbersome. To meet a growing industry have helped manufacturers of motor
or is it just smoke and mirrors? Does the fact need for testing, the surge comparison tester was testing equipment make great strides in
that the motor manufacturing and motor repair developed. This compared the wave shape of two
modernization, reliability, and tester sensitivity.
industries specifically require surge testing to verify or more identical windings against a known good
Today’s high-voltage testers use advanced
insulation integrity outweigh the few that feel that This formula implies that when the inductance winding. This comparison made it possible to
high-speed electronic evaluation of changes in
surge testing undermines reliability? Or has there decreases, the frequency increases. study insulation faults as well as find them.
resistance, leakage current, leakage current versus
been so much misinformation published that the A surge test detects a fault between turns by In the 1950s, the surge comparison test was time, voltage, step voltage, dielectric absorption,
true benefit of the test has been muddied? observing a jump in the resonant frequency of still considered fairly new. It was very useful frequency response, wave shape, corona inception
This two-part article outlines the principle, proper this LC tank circuit. If the voltage produced by
performance and insulation effects of surge the surge is greater than the weakened dielectric
testing, and the second part includes motor test strength of the turn insulation, one or more turns
results that should settle the debate. may be shorted out by arcing. This effectively
decreases the number of turns in the coil. Fewer
Principle of the Surge Test working turns reduces the inductance of the coil
Whereas the insulation resistance (IR), polarization and increases the frequency of the surge test
index (PI) and HiPot tests are used to detect ringing pattern. The voltage or amplitude of a
ground wall problems, the surge test is used to surge wave pattern is determined by:
find turn-to-turn insulation weakness. Motor
winding insulation failures often start as turn-to-
turn failures that eventually damage the ground
Where:
wall insulation and lead to catastrophic failure.
L = coil inductance
The main claim of surge testing is that it can detect
di = Delta i (instantaneous change in current)
the early stages of a problem before it becomes
dt = Delta T (amount of time to change)
severe, providing an opportunity to repair or
Therefore, just as the reduction in L (due to a
replace without unscheduled downtime.
faulty coil) causes a frequency change, it can also
Turn-to-turn insulation problems can be cause an amplitude change. But this assumes di/
definitively found with the surge test. The surge dt is constant, which is not usually the case in a
test applies a fast rise-time, high-voltage impulse modern surge test. Typically, when we see the
to a winding, which produces a voltage difference small breakdowns that are useful for predictive
between adjacent loops of wire. If the insulation maintenance, the amplitude of the surge remains
between the two loops of wire is damaged or has the same, and only the frequency shifts. The surge
been somehow weakened through operation, tester has enough energy to keep the voltage the
and if the voltage difference between the wires is same into the slightly smaller L caused by the
Testing insulation with a surge comparator (Westinghouse article, July 1951)
high enough, an arc will form between the wires. breakdown.
All of that being said, it’s also true that studies It is with all of this in mind that Megger has
have shown that the most frequent causes of asset developed PowerDB, an asset and test data
failure relate to poor or inadequate maintenance. management system that’s specifically designed
So what’s the solution? The answer is to replace to make life easier for engineers and technicians
routine maintenance carried out at regular working with electrical power systems and also to
intervals with maintenance carried out only when help users maximise the reliability of their assets
needed and as determined by a carefully structured while minimising lifetime costs.
program of testing. Modern test equipment and
A key feature of this versatile software package
techniques allow the condition of almost every
is that it runs on a readily available platform – a
type of asset to be accurately assessed without
modestly specified PC with a recent version of
the need for dismantling or long periods out of
Microsoft Windows is all that’s needed – and
service, so this is a much more effective and much
that it can easily import data from a wide variety
less costly option.
of sources, including direct from many Megger
Routine testing will form a major part of the instruments, for which it provides a simple and
program, especially for assets that are already consistent user interface. It can also acquire data
in service, but the program will also include from selected third-party test sets and import
acceptance testing for new assets and pre-service existing test data in many popular formats, a
tests for assets that have undergone repair. And feature that is particularly useful for adding
there will inevitably be a need from time to historical data. Data can also be entered manually.
time for diagnostic testing to determine the
Once captured by PowerDB, test data is stored in a
cause of the problem when an asset is not
database, and the databases from multiple devices
performing correctly.
running PowerDB can be synchronised into a
The testing program will be designed to ensure single central database for added security and to
that, as far as possible, incipient faults are detected ensure wider accessibility. It is even possible to
before they progress to failures and that assets merge data imports from other sources – such as
are replaced when they have genuinely reached external databases – to aid analysis and trending.
green for compliant, yellow for a warning period comparing new readings with historical values documentation including, for example, cover almost any standard internet browser running
and red for non-compliant. and with results from similar assets. Statistical pages, table of contents, comment and deficiency on a PC, a tablet or even a smartphone and it
information is produced which aids the evaluation summaries, test forms populated with test results opens with a summary view of activities, including
Another PowerDB option is an alert notification of test results and, therefore, assessment of the statistics about data entry and usage. Users can
and field service reports. This documentation,
system, or alert manager, will automatically send condition of the asset under test. then search and review entries in the database,
which can be printed or saved in the form of
email or text messages to pre-defined recipients which are presented in forms which are identical
Adobe Acrobat pdf files for easy electronic storage
when any time or activity threshold has been A wide range of analytical functions are available with those used elsewhere in the program.
and transmission, is an exceptionally useful aid for
reached, based on the information held in the for processing test results. These include the
planning future activities and schedules. Carefully planned testing is undoubtedly the surest
master database. This facility can be used, for generation of an asset ‘health index’ based on
example, to produce a reminder when an asset is information acquired from multiple tests, and Even though it offers wide-ranging functionality, route to maximising asset reliability, but it is only
becoming due for maintenance. The alert manager failure studies that can provide revealing insights PowerDB is intuitive in operation and easy to use. effective if the tests are carried out on schedule
into the failure rates for a population of assets. As has already been mentioned, it uses exactly the using prescribed procedures, and the results are
can also be configured to create notifications for
The intuitive PowerDB data query tool can be used same forms for data capture and for producing properly organised, stored, analysed and reported.
database entries that reveal deficiencies, invalid
to extract data from the database and present it These requirements might seem onerous, but
compliance status, out-of-limit test values and any reports, and there is a high level of uniformity
in a format that is optimised for use in further PowerDB, a powerful software package designed
other situation that can be determined from the across different applications.
studies or for processing by third-party diagnostic specifically to meet the needs of the electrical
data held in the database.
The simplicity and convenience of the standard power sector, provides a complete and cost-
software.
Versatile data trending and analysis functions are user interface can be further enhanced with the effective solution. To put it in a nutshell, a modest
further key features of PowerDB. Trending can be PowerDB can be configured to pass data to optional dashboard add-on, which is a web-based investment in software unlocks big gains in asset
performed on the fly while tests are being carried other computerised maintenance management portal that gives access to the data in the master reliability which, in turn, means money saved and
out. This offers a convenient and efficient way of systems (CMMSs) and to generate comprehensive database. The dashboard can be viewed using disruption eliminated.
RADAR – IN 1904!
It seems incredible that this system could be made
Keith Wilson - Electrical Engineer
to work given the technology available in 1904 – the
Telemobiloscope used a spark transmitter (essentially an
Most engineers and many non-engineers will have at electric arc connected to an aerial) and a coherer receiver.
least a vague idea about the beginnings of radar. It was
invented in Britain during the Second World War, wasn’t A coherer is a glass tube with metal filings loosely
it? And didn’t it help the Allies to win the war? The name contained between two metal plugs. Normally, the
electrical resistance between the plugs is high, but if the
Watson-Watt may even come to mind as one of the
device is exposed to RF energy (radio waves) the metal
leading pioneers. Well, all of this is true but it’s not quite
filings stick together (cohere) and the resistance falls
the full story. In fact, the course of history could have
to a much lower value. The device must then be reset
been very different because a form of radar was invented
by tapping it to disturb the filings so that it is ready to
and demonstrated in Germany in 1904!
respond to the next burst of radio waves.
The fascinating story is fully told in an article written by
Unfortunately, this means that coherers are inherently
V J Phillips and published in the July 1978 issue of the
sensitive to mechanical vibration so, as V J Phillips notes
British magazine, Wireless World. This article is, in turn,
in his article, they were far from ideal for use on board a
based on an item published in The Electrical Magazine
ship! Conversely, they were very insensitive to RF, so a lot
(London) in 1904.
of reflected energy from the “radar” target would have
The inventor was Christian Hülsmeyer of Düsseldorf, been needed to get any response at all.
and he called his invention the Telemobiloscope. The
Given these limitations, did the system actually work? It
Electrical Magazine notes that he demonstrated his
seems so, because The Electrical Magazine concludes
apparatus to North German Lloyd (a major maritime its piece by saying, “Experiments made so far on small
insurer), before going on to say: instruments designed for shorter distances [probably
less than a kilometre in this context] have given every
“The new invention is based on the principles of wireless
satisfaction.” British patent 13,170 was granted in 1904
telegraphy and is intended for viewing ships and
for the original apparatus, and British patent 25,608
metallic objects at sea. [No aircraft in 1904, of course!]
later in the same year for “certain improvements.”
In wireless telegraphy, the transmitter and receiver are
used separately on different ships, but both are on the Fortunately for the Allies in the Second World War, the
same ship with the Telemobiloscope. The electric waves, Telemobiloscope appears to have received little further
not being able to reach directly the receiver, must be attention, most probably because of the limitations of
reflected by metallic objects on the sea (that is ships) so the technology used. That left the field clear for Watson-
as to reach the receiver on a broken path. The advantage Watt and his team to develop the first practical radar
afforded by this invention is mainly that ships fitted with system, which had such an enormous influence on the
the transmitter and receiver will be able to view any course of the war. But, as we’ve seen, it could so easily These two diagrams are taken from the patent application. The top one shows
other ship devoid of these apparatus.” That’s a pretty have been the Germans, not the Allies, who had the the general principle, and the bottom one (presumably!) shows the arrangement
reasonable description of how radar works, isn’t it? advantage of radar in that conflict. of the apparatus.”
Q&A
Winding resistance tests are used to assess the condition of the current carrying path between transformer bushing
terminals. Experts recommend that this test is carried out routinely as, arguably, it can reveal more incipient failure
modes than most other tests. Problems such as loose, defective or incorrect connections; open, partially-open (i.e.,
broken strands); short-circuited turns in windings; or high contact resistance in tap changers will result in a change
in resistance, and therefore be indicated by an unexpectedly high, low (for short-circuits) or unstable resistance
measurement. Here are some of the questions the Megger helpline frequently receives about this invaluable test.
Q: Some more experienced colleagues has to be dissipated before leads can be safely that the clamps make good contact with the A: It is often thought that higher test currents
have told me that we have only disconnected, which can take several minutes for bushing terminals. The transformer core must speed up the saturation of large transformers but,
recently started performing routine a large transformer. To safeguard personnel, the be saturated to obtain representative results; in the majority of cases, this isn’t true. Voltage
winding resistance tests because of asset under test, and the test instrument, Megger if it isn’t, errors in excess of 20% are possible. determines the saturation rate of the test, as
the dangers involved. Can you explain winding resistance test instruments are equipped Having an understanding of which instrument is given by: (flux) ɸ = Volts * t (seconds). Therefore,
these dangers and suggest how they with multiple safety features. These include: the best to do each job is helpful. Generally, the when selecting a test instrument, compliance
can be mitigated? A safety circuit that provides an “escape test current should be greater than 1% of the voltages above 40V dc are preferred. Make sure
A: A transformer winding is an inductor and, if path” for energy dissipation. (This uses winding current rating but should not exceed
however, that the test current is greater than 1%
an inductor is suddenly open-circuited while dc current and potential leads to provide an 15%, as given in IEEE C57.152, to avoid heating
of the current rating of the winding under test. To
current is flowing through it, it will try to oppose alternate discharge path if leads are accidently of the winding. If the test current is too high, this
disconnected) improve saturation on transformer windings when
the change in current by developing a high voltage. may cause an unquantifiable error as winding
The voltage is given by V = IR + Ldi/dt, where I charging time is slow, connecting the primary
Protection/automatic discharge when input resistance is temperature dependent. Check
is the dc test current, R is the resistance of the power is lost or when the test current is and secondary windings in series may help. This
that your results compare well (within a couple
winding, L is the inductance of the winding, and accidentally changed before discharging the speeds up the test by providing more volt-turns
of percent) between phases and with previous
di/dt is the rate of change of current. If a test lead existing test current. of charge. It is important, however, to ensure that
test results. Note, however, that when you make
falls off or is pulled off a bushing terminal during the windings are connected so that the current
A test current indicator that remains comparisons with previous results, your measured
the test, a dangerously high voltage will develop. through them produces a unidirectional flux in the
functional even when instrument power is lost results, Rm, must be converted to temperature-
For example, if the winding has an inductance core. With this setup, the test current will flow
An emergency off switch compensated results, Rs, to take into account the
of 100 H, the test current is 25 A and di/dt =
temperature difference between the two tests. through the high voltage winding and the low
25/0.1 (that is, the time taken for the test lead Q: How can I be sure that my
winding resistance test results are This is particularly important if the previous test voltage winding in series, while the dc voltage
to disconnect and the current to fall from 25 A to
representative? results are factory measurements. drop will only be measured across the low voltage
0 A is 0.1 s), the voltage developed will be more
than 25,000 V! In addition, when dc test current A: Make sure that the voltage (measuring) leads Q: My test results are not stabilizing winding, for example. Since current will not flow
is injected into a winding for the duration of a are “inside” the current (source) leads – using and I’m questioning whether the into the X1 bushing terminal, be aware that
winding resistance test, a lot of energy is stored Kelvin clamps will remove any doubt about transformer core is saturated. What the X1 bushing connection integrity will not be
in a transformer’s magnetic field. This energy test connections but you’ll still need to be sure should I do? assessed during this variation of the test.
Dow
n to
eart
h
Da V with
8611 inci
7
P8 Cyber
TESTCTRICAL
diagnostic George your rity
training Ohm got it P2 Pow
knowledge! er
centre P7 facto
ER
wrong? P8 P5 yous r - Do
or do
nt
An
yous
Published by Megger
! P4
ELECTRICAL e
HV a w tool f
September 2018
Published
by Meg
Janu ger
ary 2018
TESTER nd M o
V sy r avertin
ET Newsletter
Dam
on Mou
The ind
stem
ustry’
g fai
The industry’s recognised information tool nt - Pow
s rec
er sales ognis
UHF manage
part ed
s
inform
Stranded in a substation! l
technolo ial discharg r
ures
gy
convenie with a lot e detection
ation
nce to offe tool
and r in term is a new
in
apply,
it can cost
without be used . It is quic s of capability
takin to surv k and ,
can ey HV easy
discrimi g them and to
out
dangero nate
betw of serv MV plants
us and een ice,
Putter cond and
of Meg those that itions it
ger expl are less that
Failures ains. serious. are
in the Hein
distribut HV and
ion netw
disruptive orks MV
frequen transmission
phase-to consequ tly have and
-ground ences. For costly
380 kV fault instance, and
cable
damage at a GIS in the term a rece
that installatio ination nt
could it was of a
be ten mon n caused
instance, returned ths befo so muc
a netw to service. re h
to mos ork faul the cabl
t And e
people of the city t resu
lted in in ano
ther
were of Mun loss of
signals affe ich. Up pow
and othe cted, with to 450 er
to chao r serv the failu
OR
task, on freq produced gned nanosec
for two RF spec ally gen
impossib is that it is principa high
uencies
above by PD,
UHF rece
iver trum
ond
range, erate
le – to very frequen 300 MHz concentr 300 extendin which puls
difficult l reas
routine take ons. being cies has ating MHz g up produce es by rece
noise
testing, equipm
ent out
– ofte
n virtu that importa
. The
use of particula . In cont to no an iving
leve and the ally in subs above nt ben these rly haza rast, more testing radiated
of serv 300 internal
invariab ls around seco ice for tations MHz efits, the equ rdous than is carr emission
the right test equipment to hand is definitely a installing additional electrical equipment ly high HV and nd is that emission are muc electrica the first ipment for the PD,
which test
energise ied out with s. The
Jill Duplessis - Global technical marketing The commissioning
difficult procedure , whic is a general guidelineMV insta electrica s abo h lowe l nois pulses under future is second
h mak e leve in the test, costs d, the equ
manager and Editor source of comfort! and/or protection schemes
that outlines sequential
or even
steps to be es man llations l internal ve 300 r. The
second ls have picoseco produces “health” associate so the inco ipm
is that
imp ossib followed
y test are PD, whic MHz a freq of service d nvenienc ent und
nd rang much
New
modifying existing electrical equipment and/ le tech failu h may are is that uen are elim with takin er
Given the pressures of today’s dynamic energy during the commissioning process.toThe use. steps niques re, whe characte to at cy spec e. The faste e and
or protection schemes typically reas
emission
point
to an
ristic
of
least
1 GHz trum
with fast puls r UHF
inated. g equ
ipment high
batt
You’re stranded in a remote substation and you market, electricity utilities are now, more than may, for example, include tasks such as marking and ofte es PD testi
indicative s belo impend In add compon out of
can’t leave until it’s successfully commissioned. replacing existing electrical equipment and/ prints to reflect functional test paths and voltage is usually of coro w 300 ing ition n muc ents app lications ng is usef
ery te
ever, expected to deliver the highest performance to h high up
What instrument would you choose to have with or protection schemes A han less of na or MHz betw
een dan having the er. evaluati including ul in a very
standards in all facets of their operations. This confirmation dy
testandrequirements, developing a custom a conc surface are ng the wide
ern. PD, whic UHF gerous ability as pote checking range
guide very cond
sting
Type this weblink in your browser
you to help you tackle this daunting challenge? Commissioning of EHV transmission substations checkout guide is now useful test requirements h PD testing and to discrimi ition HV term of
that establishes ntial
This scenario may seem a little unrealistic – after
makes it essential for substation commissioning to
(e.g., >100 kV) and all installations of power Megger available 29-page The first has two less serio nate and transfor of HV
compon inations,
for equipment and protection batt is that other us cond surg mers,
web schemes, transfor e arrestor
guid
free confirming
all, today’s employment laws make it difficult for be executed efficiently and expeditiously. The work
transformers, which by default includes mobile and five lang site.
The of char ery testing to the
equipm
no conn importa itions,
mers. s,
current ents
such
relay and CTuag nt ben
settings, and guid
es, aims performing e, whicbenchmark ge from 1106) ent und ection need aid whe This form and mon transformer
e fro
even the most uncaring of bosses to condemn their ranges widely in scope and complexity and may for modular substations, often attracts considerable with efits.
testing on info toand h is avai the and er test s to be n of testi itoring s
employees to extended on-site exile. Nevertheless, example include: attention at corporate level in major utilities, health
newrmaequipment
tion provCTs.ide elec lable main describe – the made and MV carrying ng is power
tenance, switchge out main
mM
and trica in s best detector also a
commissioning a substation is no small task, so it’s which is another good reason why efficient working Much
of back of of and main
a commissioning advi ce on time isl eng
engineer’s spent which practice works ar, not tenance valuable
commissioning new-build substations taining monitori ineers Perf can be
egge
work
not surprising that engineers undertaking this work is desirable.
up pow
on-site during theer.
assembly ofthes
keyeequipment orming summar for battery least
as a on HV
essentia ng the
such
The guid is new a capa ised as: Perf final
commissioning mobile substations as transformers, check
r
may sometimes feel a little stranded, even if this e disc circuit breakers, CCVTs, lcircuit sources as part city test orming Continu
Utilities have been installing equipment for over avai to
doesn’t reflect reality. In such circumstances, having lable and usse
switchers s wha switches. Transformers Perf of the when
the batt battery a capa ed on
commissioning modular substations a hundred years so most have already formulated need on the disconnect t type orming acceptan has reac city test
page
2
mar s of ery
tend edtoandtake centre ket, stage an imp ce test life or hed 85% annually Sabit
Geek
a commissioning process and there is usually little whyas proper batteriesand
handling time . if the
batteries illustrate backup to esta edance when akü
http://bit.ly/MeggerNewsletter
are 10% capa of expe the Testi
? Challeng
need to change this. The pillars of such a process will assemblyinvalidates s thewarranty and
their batt
reduces blish test at city has
good good best eries the battery. base the
since
the
cted
serv
include attention to safety and the safeguarding of riskmainof tena
future problems.workingThey way have s to very
are
specific
line valu same of the previous dropped ice
testing. nce prac main Rep es for manufac test or more
cond tain the than Subhe
system integrity, complemented by the deployment commissioning requirements tices that itionmay include eating Perf turers is belo of the adline descri
and prac through these orming ratin w 90% produ ption
of well-trained staff and an engaged workforce. The guid
important tasks such as: purp with g. ct brochu text
tical oses. in 2 year value a capa re
e also battery
■ Key
Historically, the workforce involved in substation battery s for has chan city test feature
Key feature 1 Key
goeand Perf
feature
if the
1 Key
s thro warrant
1
feature Key feature
inspection
stan SFRA testing on arrival at site, orming Follo ged sign 1 Key 1
e!
commissioning was a mix of skilled employees from dards y ificantly
1 1
(IEEE fromthe
before unloading most flooded an imp wing
set prac nce
several of the utility’s own internal departments, 450, the transport common vehicle
cells
edance IEEE
standard tice (pre
.
www.m transformer assembly witnessing
IEEE
1188, Perf and qua test ever
ferably
including protection/relay, substation design, egg rterly y year gravity ) for
er.c IEEE orm on VRL on measure tempera all from
ing capa
substation construction and maintenance. More specificationom
and/or agreement about the oil 25% city test A cells results ments ture,
the
of expe s at leas as an and reco voltage
and more, however, utilities are calling on outside filling procedure to be used cted tracing. aid to ,
service t for trending rding
Test your knowledge for your chance to win vendors to partly or even completely take over
confirmation of the correct operation of
life. every The guid and faul
the
the responsibilities that would once have rested charge, e is ava t
a selection of prizes with their own staff. This means that effective
accessories such as pumps, fans, gauges,
megger. from the
ilable
for
relays and alarms com/sup Megger downloa
£100 Amazon gift card for top prize management of the commissioning process is
port/te website d, free of
even more critical if a satisfactory outcome is to review of acceptance testing. chnical- :
Conclusion:
Scan QR code to book a Demo & get an Scan QR code to book a Demo & get an
assured GIFT assured GIFT*
http://bit.ly/2Efs7qd http://bit.ly/DLRODemo
Scan the QR code to register and & get an Scan the QR code to register and & get an
assured GIFT* assured GIFT*
OR OR
Type the weblink in your browser Type the weblink in your browser
http://bit.ly/2UrF3yR http://bit.ly/2UrF3yR