▣Features
lTimer function selection : Timer built in
lReverse power polarity protection and
over current protection built in
lWide range of power supply :
Common use of 24-240VDC/24-240VAC
lGood water proof structure : IP66(IEC specification) (MS- 2)
lVarious output types :
NPN/PNP open collector output(DC power type)
Relay contact output(AC power type) (MS-3) (MS-4)
※M S-4 is optional.
Please read "Caution for your safety" in operation
! manual before using.
▣Specifications
lFree power type
Standard type BX15M-TFR BX5M- MFR BX3M-PFR BX700-DFR
Model
Built-in Timer BX15M- TFR-T BX5M-M FR-T BX3M -PF R-T BX700-DF R-T
Type Through-beam Retroreflective Retroreflective(polarizing filter) Diffuse reflective
(* 1) (*2) (*3)
Det ect ing distance 15m 0.1 ~ 5m(MS-2) 0.1 ~ 3m(MS-3) 700mm
J-35
AC/DC Large Size Housing & Long Distance Type
lDC power type
(A)
Standard type BX15M -TDT BX5M-MDT BX3M- PDT BX700-DDT B X15 M- T DT - P BX5M-MDT-P BX3M-PDT-P BX700-DDT-P Counter
Model
Built-in Timer B X1 5M- T DT - T BX5M-MDT-T BX3M-PDT-T B X7 00- DD T -T BX15M- TDT- TP BX5M- MDT -T P BX3 M-P DT - T P B X700- DD T -T P
Retroreflective Diffuse Retroreflective Diffuse
Type Through-beam Retroreflective Through-beam Retroreflective
( polarizing ) reflective ( polarizing ) reflective
(*1) 0.1 ~ 5m (*2) 0.1 ~ 3m (*3) (*1) 0.1 ~ 5m (*2) 0.1 ~ 3m (*3) (B)
Detecting distance 15m 700mm 15m 700mm Timer
(MS-2) (MS-3 ) (MS-2) (MS -3)
(M)
5-Phase
stepping
motor &
Driver &
Controlle
J-36
BX Series
▣Characteristic
◎Through-beam ◎Diffuse reflective
lBX15M-TFR / BX15M-TFR-T lBX700-DFR / BX700-DFR-T
lBX15M-TDT / BX15M-TDT-T lBX700-DDT / BX700-DDT-T
lBX15M-TDT-P / BX15M-TDT-TP lBX700-DDT-P / BX700-DDT-TP
Parallel shifting characteristic Angle Characteristic Detecting area
Measuring Measuring Measuring Data
Data Data
method method method
Operation level Standard detecting
Receiver Stable operation level Receiver target: non-glossy
white paper
100×100mm 9 00
15 7 00
15
12
12 50 0
9
θ 9 30 0
L 6 L L
6
3 1 00
3
0
0 40 30 20 1 0 0 10 20 3 0 4 0
0
200 150 100 50 0 50 100 150 200 。6 0
80 。40
。 20
。 0 20
。 40
。 60
。 80
。
◎Retroreflective
lBX5M-MFR / BX5M-MFR-T lBX5M-MDT / BX5M-MDT-T lBX5M-MDT-P / BX5M-MDT-TP
Parallel shifting characteristic Sensor angle characteristic Mirror ang le characteristic
Measuring Measuring Measuring
Data Data Data
method method method
L L 2
2 θ 2
θ L
1 1
1
0 0 0
90 60 30 0 30 60 90 。 。 。 。 。 30
40 。20
。 10
。 0 10
。 20 。 40。
。 30
6 4 2 0 2 。
4 。
6
Left ← Center → Right Left ← Center → Right
Retroreflective Retroreflective Retroreflective
Left ← Center → Right Operation angleθ Operation angleθ
Operat ion position (mm)
J-37
AC/DC Large Size Housing & Long Distance Type
▣Control output diagram
◎Free power ◎DC power (A)
Counter
Photoelectric sensor circuit Connection NPN open collector output P NP open collector output
Photoelectric sensor circuit Connection Photoelectric sensor circuit Connection
3
Free
power Power 24-240VAC 3 3
24-240VDC Load Load (B)
circuit 5 Load Timer
2 2
Max. 50mA + Max. 50mA
3.4Ω (Self-diagnosis
N.O (Self-diagnosis - 12-24VDC output)
1 Over current
}
OUT output) + 12-24VDC
N.C protection Max. 200mA
2 250VAC 3A 1 (Control
- (C)
COM 30VDC 3A output) Temp.
4 Over current Max. 200mA 1
controlle
protection 1.5Ω (Control output) Load
Output relay
5 5
※ In case of product with the output pr otection device, if t erminals of cont rol output are short-circuited or if over current condition exists, (D)
the control output will turn off due to pr ot ect ion circuit. Power
controlle
(I)
※Operat ion for Dark ON mode is opposed to above chart indication for Light ON mode.
Proximit
※To pr event from the misoperation, output of units keeps the state of OFF for 0.5sec. after power ON. sensor
ON
Light ON (K)
Normal Mode OFF Pressur
(No delay) ON ON sensor
ON
Dark ON
OFF
ON T (L)
Light ON T T Rotary
One S hot Delay OFF encoder
ON OFF
Mode ON
Dark ON T T T
OFF (M)
5-Phase
ON stepping
Light ON T motor &
OFF Driver &
ON Delay Mode OFF ON Controlle
ON
Dark ON T T T
OFF
ON
Light ON T T T
OFF
OFF Delay Mode OFF OFF
ON
Dark ON T
OFF
J-38
BX Series
▣Connections
◎Through-beam
lBX15M-TFR1 lBX15M-TFR 2, lBX15M-TDT1 lBX15M-TDT2,
BX15M-TFR-T2 BX15M-TDT-T2
lBX15M-TDT-P2,
BX15M-TDT-TP2
- + - +
Power COM Power
24-240VAC 24-240VAC 12-24VDC 12-24VDC
24-240VDC 24-240VDC ・C
N
B X 15 M -T D T1 BX 1 5M - TD T 1
TRANSMITTER TRANSMITTER
KOREA B7
38B
KOREA B738B
Detecting Detecting
target STAB.
N・O N・C OUT
target
(NP N O・C
OUTPUT)
ON D・ON MIN
S1 S2 MODE MAXM
IN MAX
Mirror ON
S1 S2 L・ON
D・ON MIN MA
XMIN MAX
Mirror
O
ON OFF
N 0・
NOS
MD
AE
LLAY SN
1OSN
2 NOM
MA
OL
DE
NO SE NS. TI MER O
OFF
FF O
OFF
NOOFF
NDD
EE
LAY KO REA ON OF 0・SDEL
AY SEN S. TI MER
O AY
L 3B038A OFF
FF O
OF
NOOFF
NDD
EE
LAY KOR EA
O LAY 3B038A
COM
◎Diffuse reflective
lBX700-DFR, BX700-DFR-T lBX700-DDT, BX700-DDT-T
lBX700-DDT-P, BX700-DDT-TP
ON
S1 S2 MD ON
・ ON
IN
M AXMIN
M MA
X D・ON
OL
DE MIN MA
XMIN MAX
ON ON NOM A S1 S2 MODE
SENS . TIMER
OFF
N OFF ・ND
0 SE
DLA
EL
AY
Y O
ON OFF
N 0・
NOS
MD
AE
LLA
O ON O NO Y SEN S. TI MER
K038
ORA
A
E
OFFOFF OF DE
LAY B
3 OFF
FF O
OFF
NOOFF
NDD
EE
LAY KO REA
O AY
L 3B038A
COM
◎Cable
Cover
Wire holder
B X3M- S TA
B
. OU
T
MFR -T S
1
S
2
L・O
N
Water proof O
N
S S
D・ MI MA M I MA
rubber
MO D
O1 2
O NOMEA
Washer O
N
N
OF
OF
F
F
OF
N
FO
OF
F
N
0・S
L
ON
OFF
S EN
S
. T IM E
R
K OR E
3B 038
A
A
J-39
AC/DC Large Size Housing & Long Distance Type
▣Front panel identification
(A)
◎Through-beam Counter
D・ON / L・ON by slide switch
Self-diagnosis indicator(Green)
Timer mode selection switch
Terminal No. Power indicator(Yellow) Operation indicator(Yellow)
Terminal No.
(B)
BX 15M -T DT 1 OPER
BX15M-TDT2-T
STAB. OUT Timer
S1 S 2 L・ ON
TRANSMITTER ON
D・O N MIN MAX MIN MAX
S1 S 2 MO DE
ON O N NO MA L
ON OFF 0・SD ELA Y SENS. TIMER
O FF O N ON D ELAY K O R EA
O FF OFF OFF D ELAY 3B 0 38A
KO RE A B738 B
[Emitter] [Receiver]
(C)
Sensitivity V R Timer VR Temp.
controlle
STAB. OUT
BX3M- MDT-T STAB. OUT
S1 S2 ・L O N
BX700- DDT -T
S1 S2 L・ O N
(E)
ON
D・O N MI N MAXM IN MAX ON
Panel
D ・ON
meter
S1 S2 M OD E MI N MAXM IN MAX
O N ON N OM AL S1 S2 M OD E
O N O FF 0・S DE LAY SENS. TIM ER O N ON N OM AL
OF F ON O N DEL AY K OR E A O N O FF 0・S DE LAY SENS. TIM ER
OF F O FF O FF DEL AY 3B 038 A OF F ON O N DEL AY K OR E A
OF F O FF O FF DEL AY 3B 038 A
▣Dimensions Unit:mm
(G)
Display
unit
lProduct lBracket
(H)
Sensor
controlle
73.5
80
16
(I)
6.5
45 Proximit
sensor
50.5
25 80
25 (J)
Photo
Optical axis Optical axis electri c
sensor
(K)
Pressur
sensor
Hexagonal nut
(side: 22mm)
Applicable cable M4 BOLT
25.4 5 40 M4 BOLT M4 BOLT (L)
ø6~ø10
Rotary
encoder
lBracket
U MS-2 U MS-3 U MS-4 (M)
5-Phase
40.5 86.1 stepping
8 8.4 25.9 1.7 motor &
34 34 7
Driver &
8 3-4.2 Controlle
24
46.5
50.5
4 6.5
24 3 -4.2
8 6.8
2-ø3.2 20 2
29.3
2-ø3.8 2.5 4-ø3.6
J-40
BX Series
▣Mounting & Adjustment ◎Retroreflective type
1. Supply the power to the photoelectric sensor,
◎Through-beam type
after setting the photoelectric sensor and the
1. Supply the power to the photoelectric sensor, mirror(MS-2)in face to face.
after the emitter and the receiver in face to face. 2. Set the photoelectric sensor in the position
2. Set the receiver in center of position where which indicator turns on, as adjusting the mirror
indicator turns on, as adjusting the receiver or or the sensor right and left, up and down.
the emitter right and left, up and down. 3. Fix both units tightly after checking that the unit
3. Fix both units tightly after checking that the unit detects the target.
detects the target. ※If use more than 2 photoelectric sensor in parallel,
※If the detecting target is translucent body or the space between them should be more than 30cm.
smaller than ø15mm, it might not detect the
target cause light passed.
※Sensitivity adjustment : Please see the diffuse Adjust Mirror
Right/Left (MS-2)
reflective type. Photoelectric
sensor
A djust
Right/Left Receiver
ⓑ Vertical direction
Photoelectric
sensor polarizing filter
Receiver
MIN MAX
MS-2
※The detecting distance indicated on specification Mirror(MS-3)
chart is against 200×200mm of non-glossy white E mit ter
paper.Be sure that it can be different by size, Horizontal direction
surface and gloss of target. polarizingfilt er
J-41