Вы находитесь на странице: 1из 6

CONTRACT NO :

DATASHEET
-

PAGE
15NO03-DS-60-004
1 OF 6

PENGADAAN SEMARANG GAS DISTRIBUTION PIPE LINE (CP-16)

DATASHEET SHUTDOWN VALVE

CLIENT : PT. PERUSAHAAN GAS NEGARA (Persero) Tbk.

CONTRACTOR : KONSORSIUM WIKA - MGP - SGI

PROJECT NAME : PENGADAAN SEMARANG GAS

DISTRIBUTION PIPELINE (CP-16)

LOCATION : SEMARANG

DOCUMENT NO. : 15NO03-DS-60-004

Issued for Bid RA DA DS


Revision By Checked Approved Checked Approved
DATE Status Code
Code ENG. DIP PT. WIKA BUS. DEV
PENGADAAN SEMARANG GAS DISTRIBUTION PIPE LINE (CP-16)

Date :
15NO03-DS-60-004 Rev. 0 DATASHEET SHUTDOWN VALVE 05/03/2015
Page : 2 of 6

REVISION SHEET

REVISION CODE REVISION CODE REVISION CODE


Page Page Attachment
A B C D 0 1 2 A B C D 0 1 2 A B C D 0 1 2

1
2
3
4
5
PENGADAAN SEMARANG GAS DISTRIBUTION PIPE LINE (CP-16)

Date :
15NO03-DS-60-004 Rev. 0 DATASHEET SHUTDOWN VALVE 05/03/2015
Page : 3 of 6

COMMENT SHEET

Revision Comment Implementation


Chapter Page Revision Note Remark
Code (Yes/No)
PENGADAAN SEMARANG GAS
DISTRIBUTION PIPE LINE (CP-16)

TITLE DOCUMENT NUMBER REV PAGE


DATASHEET SHUTDOWN VALVE 15NO03-DS-60-004 0 4 of 6

1 Tag No. 3322-SDV-001


2 Quantity 1
GENERAL

3 Service OUTLET FROM OTHER STATION NATURAL GAS TO GAS FILTER


4 Line No. / Vessel No. 12"-PG-3322-EC1-001
5 P&ID No. CP16-PGN-3322-PS-DG-001-A1
6 Line Size / Schedule No. 12"
7 Pipe Insulation None
8 Design Code API 6D
DESIGN

9 Material Piping Specification -


10 Firesafe Valve API 6FA or API 607 STD
11 NACE Service Yes - NACE MR0175
12 Fluid Type Natural Gas
13 Fluid State Vapor
SERVICE CONDITIONS

14 Operating Pressure 1247 psig


15 Design Pressure 1870.5 psig
Operating Temperature 82.4 0
16 F
Design Temperature 150 0
17 F
18 Max. Shutoff dP - psig
19 Max. Flow 14.4 MMSCFD
Hc Dew Point -40 0
20 F
Ambient Temp 87.8 0
21 F
22 Corrosive Compounds No
23 Type of Connection Flanged End 53 Manufacturer VTA
24 Body Size/Rating 12"/900# 54 Model No VTA
25 Type of Valve Ball Valve 55 Type Pneumatic Spring Return
26 Seat Design Double Piston 56 Double/Single Acting Double
27 Trim size Reduced 57 Control Schematic VTA
28 Body/Bonnet Material ASTM A350 LF2 58 Actuating Media Pneumatic Gas
29 Ball/Stem/Seat Ring Material ASTM A350 LF2 with 0.08 59 Gas Supply Press. 80-145 psig
Body Seat/Seat Arrgt. Prime
30 ASTM A350 LF2 60 Start Torque (Open/Close) Note 5
VALVE BODY / BONNET

Seal
31 Valve Leakage Class VI/Thight Shut Off 61 Run Torque (Open/Close) Note 5
32 Nominal Bore Full Bore 62 End Torque (Open/Close) Note 5
ACTUATOR

33 Seals O-Ring Viton AED 63 Pneumatic Connection Tubing


ASTM A193 Grade B7 / Direct mounted on valve
34 Bolts/Nuts 64 Actuator Oriented
ASTM A194 Grade 2H stem-vertical
35 Break torque (open/close) Note 1 65 Stroke time (open/close) 0.5 second per inch
36 Run torque (open/close) Note 2 66 Operational Position Open
37 End torque (open/close) Note 3 67 Air Failure position Close
38 Stem Shear torque Note 4 68 Relief Valve Yes
39 Lubricator VTA 69 Boost/Quick Exhaust Yes
Filter Regulation and Pressure
40 Valve body orientation Horisontal 70 Yes
Gauge
41 End Connection WE/FE 71 Local Position Indicator Yes
42 Mounted Type Trunnion 72 Hand Wheel Yes
43 Lifting Eyes/Support Legs Yes/Yes 73 Adjustable travel stops Yes
44 Double Block and Bleed Yes 74 Speed controls Yes
45 Tag Number VTA 75 Accumulator VTA
46 Type Proximity Switches 76 Tag Number VTA
POSITION FEEDBACK

47 Switch type/rating 3 x DPDT / 1A, 24 VDC 75 Manufacturer VTA


48 IP rating IP 65 76 Model No VTA
49 Switch certification VTA 77 Port Type/Size 3 way/ 1/2" (note 3)
SOLENOID

50 Cable entry VTA 78 Body Material Aluminium


51 Switchbox enclosure matr. Aluminium 79 Direct/Pilot Operated Direct
80 Manual overide/Reset Yes
52 VTA
Switchbox box certification 81 Solenoid CV VTA
53 Manufacturer VTA 82 Power supply/consumption VTA
54 Model No VTA 83 IP rating IP 55
55 Digital Protocol N/A 84 Hazardous Area classification Class 1, zone 0
56 Output Signal 4-20 mA 85 Cable entry VTA
Notes :
1 ) All Accessories to be mounted on the actuator on a 316 SS Mounting Plate
2 ) Limit Switches shall be mounted inside the Eexd certified enclosure and pre-wired to terminals
3 ) VTA-Vendor to Advised
4 ) TBA-To be Advised
5 ) ESD Valve shall be provided for safety factor 1.3
PENGADAAN SEMARANG GAS
DISTRIBUTION PIPE LINE (CP-16)

TITLE DOCUMENT NUMBER REV PAGE


DATASHEET SHUTDOWN VALVE 15NO03-DS-60-004 0 5 of 6

1 Tag No. 3322-SDV-006


2 Quantity 1
GENERAL

3 Service METERING 3322-GM-002 A/B


4 Line No. / Vessel No. 12"-PG-3322-EC1-019
5 P&ID No. CP16-PGN-3322-PS-DG-002-A1
6 Line Size / Schedule No. 12"
7 Pipe Insulation None
8 Design Code API 6D
DESIGN

9 Material Piping Specification -


10 Firesafe Valve API 6FA or API 607 STD
11 NACE Service Yes - NACE MR0175
12 Fluid Type Natural Gas
13 Fluid State Vapor
SERVICE CONDITIONS

14 Operating Pressure 451-1276 psig


15 Design Pressure 2114 psig
Operating Temperature 83 0
16 F
Design Temperature 158 0
17 F
18 Max. Shutoff dP - psig
19 Max. Flow 184.97 MMSCFD
Hc Dew Point -40 0
20 F
Ambient Temp 87.8 0
21 F
22 Corrosive Compounds No
23 Type of Connection Flanged End 53 Manufacturer VTA
24 Body Size/Rating 12"/900# 54 Model No VTA
25 Type of Valve Ball Valve 55 Type Pneumatic Spring Return
26 Seat Design Double Piston 56 Double/Single Acting Double
27 Trim size Reduced 57 Control Schematic VTA
28 Body/Bonnet Material ASTM A350 LF2 58 Actuating Media Pneumatic Gas
29 Ball/Stem/Seat Ring Material ASTM A350 LF2 with 0.08 59 Gas Supply Press. 80-145 psig
Body Seat/Seat Arrgt. Prime
30 ASTM A350 LF2 60 Start Torque (Open/Close) Note 5
VALVE BODY / BONNET

Seal
31 Valve Leakage Class VI/Thight Shut Off 61 Run Torque (Open/Close) Note 5
32 Nominal Bore Full Bore 62 End Torque (Open/Close) Note 5
ACTUATOR

33 Seals O-Ring Viton AED 63 Pneumatic Connection Tubing


ASTM A193 Grade B7 / Direct mounted on valve
34 Bolts/Nuts 64 Actuator Oriented
ASTM A194 Grade 2H stem-vertical
35 Break torque (open/close) Note 1 65 Stroke time (open/close) 0.5 second per inch
36 Run torque (open/close) Note 2 66 Operational Position Open
37 End torque (open/close) Note 3 67 Air Failure position Close
38 Stem Shear torque Note 4 68 Relief Valve Yes
39 Lubricator VTA 69 Boost/Quick Exhaust Yes
Filter Regulation and Pressure
40 Valve body orientation Horisontal 70 Yes
Gauge
41 End Connection WE/FE 71 Local Position Indicator Yes
42 Mounted Type Trunnion 72 Hand Wheel Yes
43 Lifting Eyes/Support Legs Yes/Yes 73 Adjustable travel stops Yes
44 Double Block and Bleed Yes 74 Speed controls Yes
45 Tag Number VTA 75 Accumulator VTA
46 Type Proximity Switches 76 Tag Number VTA
POSITION FEEDBACK

47 Switch type/rating 3 x DPDT / 1A, 24 VDC 75 Manufacturer VTA


48 IP rating IP 65 76 Model No VTA
49 Switch certification VTA 77 Port Type/Size 3 way/ 1/2" (note 3)
SOLENOID

50 Cable entry VTA 78 Body Material Aluminium


51 Switchbox enclosure matr. Aluminium 79 Direct/Pilot Operated Direct
80 Manual overide/Reset Yes
52 VTA
Switchbox box certification 81 Solenoid CV VTA
53 Manufacturer VTA 82 Power supply/consumption VTA
54 Model No VTA 83 IP rating IP 55
55 Digital Protocol N/A 84 Hazardous Area classification Class 1, zone 0
56 Output Signal 4-20 mA 85 Cable entry VTA
Notes :
1 ) All Accessories to be mounted on the actuator on a 316 SS Mounting Plate
2 ) Limit Switches shall be mounted inside the Eexd certified enclosure and pre-wired to terminals
3 ) VTA-Vendor to Advised
4 ) TBA-To be Advised
5 ) ESD Valve shall be provided for safety factor 1.3
PENGADAAN SEMARANG GAS
DISTRIBUTION PIPE LINE (CP-16)

TITLE DOCUMENT NUMBER REV PAGE


DATASHEET SHUTDOWN VALVE 15NO03-DS-60-004 0 6 of 6

1 Tag No. 3322-SDV-007


2 Quantity 1
GENERAL

3 Service METERING 3322-GM-002 A/B


4 Line No. / Vessel No. 12"-PG-3322-EC1-020
5 P&ID No. CP16-PGN-3322-PS-DG-002-A1
6 Line Size / Schedule No. 12"
7 Pipe Insulation None
8 Design Code API 6D
DESIGN

9 Material Piping Specification -


10 Firesafe Valve API 6FA or API 607 STD
11 NACE Service Yes - NACE MR0175
12 Fluid Type Natural Gas
13 Fluid State Vapor
SERVICE CONDITIONS

14 Operating Pressure 451-1276 psig


15 Design Pressure 2114 psig
Operating Temperature 83 0
16 F
Design Temperature 158 0
17 F
18 Max. Shutoff dP - psig
19 Max. Flow 184.97 MMSCFD
Hc Dew Point -40 0
20 F
Ambient Temp 87.8 0
21 F
22 Corrosive Compounds No
23 Type of Connection Flanged End 53 Manufacturer VTA
24 Body Size/Rating 12"/900# 54 Model No VTA
25 Type of Valve Ball Valve 55 Type Pneumatic Spring Return
26 Seat Design Double Piston 56 Double/Single Acting Double
27 Trim size Reduced 57 Control Schematic VTA
28 Body/Bonnet Material ASTM A350 LF2 58 Actuating Media Pneumatic Gas
29 Ball/Stem/Seat Ring Material ASTM A350 LF2 with 0.08 59 Gas Supply Press. 80-145 psig
Body Seat/Seat Arrgt. Prime
30 ASTM A350 LF2 60 Start Torque (Open/Close) Note 5
VALVE BODY / BONNET

Seal
31 Valve Leakage Class VI/Thight Shut Off 61 Run Torque (Open/Close) Note 5
32 Nominal Bore Full Bore 62 End Torque (Open/Close) Note 5
ACTUATOR

33 Seals O-Ring Viton AED 63 Pneumatic Connection Tubing


ASTM A193 Grade B7 / Direct mounted on valve
34 Bolts/Nuts 64 Actuator Oriented
ASTM A194 Grade 2H stem-vertical
35 Break torque (open/close) Note 1 65 Stroke time (open/close) 0.5 second per inch
36 Run torque (open/close) Note 2 66 Operational Position Open
37 End torque (open/close) Note 3 67 Air Failure position Close
38 Stem Shear torque Note 4 68 Relief Valve Yes
39 Lubricator VTA 69 Boost/Quick Exhaust Yes
Filter Regulation and Pressure
40 Valve body orientation Horisontal 70 Yes
Gauge
41 End Connection WE/FE 71 Local Position Indicator Yes
42 Mounted Type Trunnion 72 Hand Wheel Yes
43 Lifting Eyes/Support Legs Yes/Yes 73 Adjustable travel stops Yes
44 Double Block and Bleed Yes 74 Speed controls Yes
45 Tag Number VTA 75 Accumulator VTA
46 Type Proximity Switches 76 Tag Number VTA
POSITION FEEDBACK

47 Switch type/rating 3 x DPDT / 1A, 24 VDC 75 Manufacturer VTA


48 IP rating IP 65 76 Model No VTA
49 Switch certification VTA 77 Port Type/Size 3 way/ 1/2" (note 3)
SOLENOID

50 Cable entry VTA 78 Body Material Aluminium


51 Switchbox enclosure matr. Aluminium 79 Direct/Pilot Operated Direct
80 Manual overide/Reset Yes
52 VTA
Switchbox box certification 81 Solenoid CV VTA
53 Manufacturer VTA 82 Power supply/consumption VTA
54 Model No VTA 83 IP rating IP 55
55 Digital Protocol N/A 84 Hazardous Area classification Class 1, zone 0
56 Output Signal 4-20 mA 85 Cable entry VTA
Notes :
1 ) All Accessories to be mounted on the actuator on a 316 SS Mounting Plate
2 ) Limit Switches shall be mounted inside the Eexd certified enclosure and pre-wired to terminals
3 ) VTA-Vendor to Advised
4 ) TBA-To be Advised
5 ) ESD Valve shall be provided for safety factor 1.3