Вы находитесь на странице: 1из 38

Deep Sea Electronics

PRODUCT
GUIDE
Visit our website for full product
information and downloads

www.deepseaplc.com

View the complete Register a Keep up to Watch company


DSE product website account date with and product
range and download the latest testing
full product company news videos
documentation and product
& PC software releases
Genuine UK Quality
“DSE continues to invest millions of pounds into the latest
state-of-the-art design and production equipment for our
bespoke manufacturing facility in North Yorkshire.

Being in complete control of the manufacturing process from


design concept to finished product ensures we meet the
increasing demand for our products and maintain the premium
quality we have become renowned for all over the world.
Mark Dresser
Production Director
DSEGenset ®
DSEAts ®

INDUSTRY LEADING GENERATOR DEDICATED AUTO TRANSFER SWITCH


CONTROL MODULES CONTROL MODULES

MANUAL/AUTO START CONTROL MODULES AUTO MAINS (UTILITY) FAILURE CONTROL MODULES AUTOMATIC TRANSFER SWITCH CONTROL MODULES

NEW NEW
NEW

DSE402MKII DSE701MKII DSE3110 DSE3210 DSE4220 DSE4520 MKII DSE6020 MKII DSE6120 MKII DSE330 DSE331 DSE334 DSE335 DSE160

NEW
NEW NEW
NEW

DSEPower ®

DSE4210 DSE4510 MKII DSE6010 MKII DSE6110 MKII DSE7120 MKII DSE7320 MKII DSE7420

INTELLIGENT BATTERY CHARGERS


EXPANSION MODULES AND POWER SUPPLIES
NEW

INTELLIGENT BATTERY CHARGERS


DSE7110 MKII DSE7310 MKII DSE7410 HIGH POWERED DUAL
ENCLOSED
INTELLIGENT OUTPUT
DSE103 DSE123 DSE124 DSE125 DSE2130
NEW
NEW
SYNCHRONISING AND LOAD SHARING CONTROL MODULES NEW

NEW NEW DSE9470 MKII, DSE9472 MKII DSE9460 DSE9474 DSE9450 DSE9462
DSE9480 MKII, DSE9481 MKII DSE9461 DSE9452
DSE2131 DSE2133 DSE2152 DSE2157 DSE2548 DSE9473 NEW DSE9479
DSE9483 NEW
DSE9476 R&D
DSE8610 MKII DSE8620 DSE8660 MKII DSE8661 DSE8680 ENGINE CONTROL LIGHTING TOWER DC CONTROL MAINS/UTILITY
MODULES CONTROL MODULE MODULE DECOUPLING RELAY BATTERY CHARGERS
SWITCH POWER REMOTE
MODE SUPPLY DISPLAY

DSEE800 DSEE400 DSEL401 MKII DSE7450 DSEP100


DSE8710/60 DSE8721 DSE8810 DSE8860 DSE8711/8716
DIGITAL AUTOMATIC DSE9130 DSE9701 DSE160 DSE2541
DSE9150 DSE9702
VOLTAGE REGULATOR DSE9155
DSE9255
NEW
DSEA106

DSECommunications DSE8004 DSE8003 DSE8005 DSE855/857 DSE2510/2520 DSE890 & DSE891


DSEWebNet® Gateway
DSE892 SNMP
Gateway
SHAPING THE
FUTURE OF
SYNCHRONISING

DSE8610 MKII
Performance is Everything. NEW FEATURES
DUE - 4TH QUARTER 2016

– Powerful dual core main processor and high-capacity memory. Including sophisticated emission
– User definable start-up screen for adding individual control with DPF regeneration &
soot capture and full Tier IV
customer logos.
engine support.
– DTC display provides visibility of current and historic alarms
in the ECU memory. Get in touch with the DSE
– Auto voltage sensing with alternative configuration. Marketing team to find out
– Data logging. more about future product
developments.
+ Many more outstanding NEW features.
marketing@deepseaplc.com

www.deepseaplc.com
Simple
Upgrade
Path
PANEL CUT-OUT
220mm x 160mm
8.7” x 6.3”

DSE7xxx & 8xxx


Range

DSE7110 AS DSE7210 AS DSE335 ATS


MKII DSE7220 AMF
DSE7120 AMF
MKII

DSE7310 AS DSE7410 AS
MKII DSE7420 AMF
DSE7320 AMF DSE7450
MKII

DSE8610 LS DSE8810 LS
MKII DSE8860 LS
DSE8620 LS
DSE8660 LS
MKII
DSE8661 LS
DSE8680 LS
The DSE simple upgrade path offers the most
flexible and efficient approach to panel design.

Step 1
Select the right product range for your business.

Step 2
Implement the cut-out size into your panel designs.

Step 3
Choose the product within the range that matches your
application requirements and fit this to all panels as standard.

Step 4
When greater functionality is required replace your standard
product with a higher specification product from the same range.
There is no need to alter the cut-out size.

PANEL CUT-OUT PANEL CUT-OUT PANEL CUT-OUT


182mm x 137mm 118mm x 92mm 80mm x 68mm
7.2” x 5.4” 4.6’’ x 3.6” 3.1” x 2.7”

DSE6xxx DSE4xxx DSE3xxx


Range Range Range

DSE6010 AS DSE4210 AS DSE3110 MS/


MKII DSE4220 AMF AS
DSE6020 AMF
MKII

DSE4510 AS DSE3210 MS/


DSE4520 AMF AS
DSE6110 AS
MKII
DSE6120 AMF
MKII
DSEL401 AS/L DSE330 ATS
MKII

DSE334 ATS
DSEGenset ®

MANUAL/AUTO START
CONTROL MODULES

DSE402 MKII DSE701 MKll DSE3110 DSE3210


- Key start - Configurable auto and - Back-lit icon LCD display - Key switch
- Low oil pressure protection manual start versions - Front panel editing - Configurable inputs (6)
- High engine temperature - Remote start input available - LED and LCD alarm - Configurable outputs (2)
protection (when in auto start mode) indication - Back-lit icon LCD display
- Auxiliary shutdown - Auxiliary shutdown input - Power save mode - LED and LCD alarm
- PC configurable via available (when in manual - CAN and magnetic pick-up/ indication
DSE813 interface and DSE start mode) Alt. versions available (specify - USB configurable
Configuration Suite PC - Engine monitoring and on ordering) - Configurable timers and
Software protection - PC configurable alarms
- Automatic engine pre-heat - LED status indication - 6 digital inputs - Alternative configuration
- Overspeed protection - Automatic engine pre-heat - 4 outputs (2 configurable - Remote start input
+ many more features - Overspeed protection on magnetic pick up/Alt. 4 - Generator voltage display
- Front panel mounting configurable on CAN version) - Generator frequency display
+ many more features - Alternative configuration - Battery voltage display
- Configurable timers and - Engine speed display
alarms - Hours counter
- Remote start input - Engine pre-heat
- Generator voltage display - Comprehensive shutdown
- Generator frequency display or warning on fault condition
- Battery voltage display + many more features
- Engine speed display
DSE4210 - Hours counter
- User friendly fault indication - Engine pre-heat
by LED - Comprehensive shutdown or
- Fully configurable via the warning on fault condition
fascia or PC using USB + many more features
communication
- Extremely efficient power
save mode
- 3 phase generator sensing
- Compatible with 600 V AC
Ph to Ph nominal systems
- Fuel and start outputs
- 4 configurable DC outputs
- 7 configurable digital inputs
- Configurable staged loading
outputs
- Alternator speed sensing
- 3 engine maintenance alarms
- Engine speed protection
- Engine hours counter
- Engine pre-heat
- Engine run-time scheduler
- Battery voltage monitoring
- Start on low battery voltage
- Configurable remote start
input
- 1 alternative configuration
- Comprehensive warning,
electrical trip or shutdown
protection upon fault
condition
- Event log (15)
+ many more features
DSEGenset ®

NEW NEW
NEW

DSE4510 MKII DSE6010 MKII DSE6110 MKII DSE7110 MKII


- Largest back-lit icon display - Large back-lit icon display - Large back-lit text display - Large back-lit icon display
in its class - Heated display option - Multiple display languages - Heated display option
- Current sensing, real-time available - Heated display option available
clock & heated display - Fully configurable via the available - Fully configurable via the
options available fascia or PC using USB - DSENet® expansion fascia or PC using USB
- Fully configurable via the communication compatible communication
fascia or PC using USB - Efficient power save mode - Data logging facility - Extremely efficient power
communication - 3 phase generator sensing - Fully configurable via PC save mode
- Extremely efficient power - Generator/load power using USB communication - 3 phase generator sensing
save mode monitoring (kW, kV A, kV - Front panel configuration - Generator/load power
- 3 phase generator sensing Ar, pf) - Efficient power save mode monitoring (kW, kV A,
- Compatible with 600 V ph - - Generator overload - 3 phase generator sensing kV Ar, pf)
ph nominal systems protection (kW) - Generator/load power - Generator overload
- Generator/load power - Generator/load current monitoring (kW, kV A, kV protection (kW)
monitoring (kW, kV A, monitoring and protection Ar, pf) - Generator/load current
kV Ar, pf) - Breaker control via fascia - Generator/load current monitoring and protection
- Generator overload buttons monitoring and protection - Fuel and start outputs
protection (kW) - Fuel and start outputs, - Breaker control via fascia (configurable when using
- Generator/load current configurable when using buttons CAN)
monitoring and protection CAN - Fuel and start outputs, - 4 configurable DC outputs
- Fuel and start outputs - 4 configurable DC outputs configurable when using - 2 configurable volt-free
(configurable when using - 4 configurable analogue/ CAN outputs
CAN) digital inputs - 4 configurable DC outputs - 4 configurable analogue/
- 2 configurable DC outputs - 6 configurable digital inputs - 4 configurable analogue/ digital inputs
- 3 configurable analogue/ - Support for 0-10 V & 4-20 digital inputs - 6 configurable digital inputs
digital inputs mA oil pressure sensors - Support for 0 to10 V & 4 to - Configurable staged loading
- 4 configurable digital inputs - Configurable staged loading 20 mA oil pressure sensors outputs
- Configurable staged loading outputs - 6 configurable digital inputs - CAN, MPU and alternator
outputs - CAN, MPU and alternator - Configurable staged loading speed sensing in one variant
- CAN and alternator speed speed sensing in one variant outputs - 3 engine maintenance alarms
sensing in one variant - 3 engine maintenance alarms - CAN, MPU and alternator - Engine speed protection
- 3 engine maintenance alarms - Engine speed protection speed sensing in one variant - Engine hours counter
- Engine speed protection - Engine hours counter - 3 engine maintenance alarms - Engine pre-heat
- Engine hours counter - Engine pre-heat - Engine speed protection - Engine run-time scheduler
- Engine pre-heat - Engine run-time scheduler - Engine hours counter - Engine idle control for
- Engine run-time scheduler - Engine idle control for - Engine pre-heat starting & stopping
- Engine idle control for starting & stopping - Engine run-time scheduler - Battery voltage monitoring
starting & stopping - Fuel pump control - Engine idle control for - Start on low battery voltage
- Battery voltage monitoring - Real-time clock starting & stopping - Real-time clock
- Start on low battery voltage - Battery voltage monitoring - Fuel pump control - Fuel pump control
- Configurable remote start - Start on low battery voltage - Real time clock - Configurable remote start
input - Configurable remote start - Battery voltage monitoring input
- 1 alternative configuration input - Start on low battery voltage - 1 alternative configuration
- Comprehensive warning, - 1 alternative configuration - Configurable remote start - Comprehensive warning,
electrical trip or shutdown - Comprehensive warning, input electrical trip or shutdown
protection upon fault electrical trip or shutdown - 1 alternative configuration protection upon fault
condition protection upon fault - Comprehensive warning, condition
- LCD alarm indication condition electrical trip or shutdown - LCD and LED alarm
- Event log (50) - LCD and LED alarm protection upon fault indication
+ many more features indication condition - Event log (50)
- Configurable event log (50) - LCD and LED alarm + many more features
+ many more features indication
- Customisable information
screens
- Configurable event log (100)
+ many more features
DSEGenset ®

MANUAL/AUTO START
CONTROL MODULES
NEW

DSE7310 MKII DSE7410


- 4-line back-lit LCD text - Fuel usage monitor and low - Configurable inputs (11)
display fuel level alarms - Configurable outputs (8)
- Multiple display languages - Simultaneous use of RS232 - Voltage measurement
- Five key menu navigation and RS485 communication - Dedicated load test button
- LCD alarm indication ports - kW overload alarms
- Heated display option - True dual mutual standby - Comprehensive electrical
available using RS232 or RS485 protection
- Customisable power-up text for accurate engine hours - RS232, RS485 & Ethernet
and images balancing remote communications
- DSENet® expansion - MODBUS RTU support - MODBUS RTU/TCP
compatibility with configurable MODBUS - PLC functionality
- Data logging facility pages. - Multi event exercise timer
- Internal PLC editor - Advanced SMS messaging - Back-lit LCD 4-line text
- Protections disable feature (additional external modem display
- Fully configurable via PC required) - Multiple display languages
using USB, RS232 & RS485 - Start & stop capability via - Automatic start/manual start
communications SMS messaging - Audible alarm
- Front panel configuration - 3 configurable maintenance - Fixed and flexible LED
with PIN protection alarms indicators
- Power save mode - Compatible with a wide - Event log (250)
- 3 phase generator sensing range of CAN engines, - Engine protection
and protection including tier 4 engine - Fault condition notification to
- Generator current and power support a designated PC
monitoring (kW, kvar, kVA, pf) - Uses DSE Configuration - Front panel mounting
- kW and kvar overload and Suite PC Software for - Protected front panel
reverse power alarms simplified configuration programming
- Over current protection - Licence-free PC software - Configurable alarms and
- Unbalanced load protection - IP65 rating (with supplied timers
- Independent earth fault gasket) offers increased - Configurable start and stop
protection resistance to water ingress timers
- Breaker control via fascia - Modules can be integrated - Five-key menu navigation
buttons into building management - Front panel editing with PIN
- Fuel and start outputs systems (BMS) using protection
configurable when using MODBUS RTU - 3 configurable maintenance
CAN + many more features alarms
- 6 configurable DC outputs - CAN and magnetic pick-up/
- 2 configurable volt-free relay Alt. sensing
outputs - Fuel usage monitor and low
- 6 configurable analogue/ fuel alarms
digital inputs - Charge alternator failure
- Support for 0 V to 10 V & 4 alarm
mA to 20 mA sensors - Manual speed control (on
- 8 configurable digital inputs compatible CAN engines)
- Configurable 5 stage dummy - Manual fuel pump control
load and load shedding - “Protections disabled”
outputs feature
- CAN, MPU and alternator - Reverse power protection
frequency speed sensing in - Power monitoring (kW h, kV
one variant Ar, kV A h, kV Ar h)
- Real time clock - Load switching (load
- Manual and automatic fuel shedding and dummy load
pump control outputs)
- Engine pre-heat and post- - Unbalanced load protection
heat functions - Independent earth fault trip
- Engine run-time scheduler - Integral PLC editor
- Engine idle control for + many more features
starting & stopping
DSEGenset ®

DSEGenset ®

UNOPS - Vital Power


The island of Haiti has suffered major disruption since the earthquakes
of 2010 leaving Port Au Prince and its surrounding areas without power
for long periods of time.

In a recent project to address the power shortages DSE8610 and


DSE331 modules were installed in 3 hospitals built by the UN.

Each hospital has 3 generators running in parallel with a DSE331


operating the transfer of the load from and to the mains (utility). Mains
(Utility) power was seldom present. Out of ten days during installation
the grid was available for less than one hour, leaving hospital facilities
useless and making the genset settings and configuration crucial.

All three hospitals are now fully operational and the client and patients
are extremely happy with the end result.

Article supplied by Sistemas de Energía, S.A. — DSE Distributor

www.deepseaplc.com
DSEGenset ®

AUTO MAINS (UTILITY)


FAILURE CONTROL MODULES
NEW NEW
NEW

DSE4220 DSE4520 MKII DSE6020 MKII DSE6120 MKII


- User friendly fault indication - Largest back-lit icon display - Large back-lit icon display - Large back-lit text display
by LED in its class - Heated display option - Multiple display languages
- Fully configurable via the - Current sensing, real-time available - Heated display option
fascia or PC using USB clock & heated display - Fully configurable via the available
communication options available fascia or PC using USB - DSENet® expansion
- Extremely efficient power - Fully configurable via the communication compatible
save mode fascia or PC using USB - Efficient power save mode - Data logging facility
- 3-phase generator sensing communication - 3-phase generator sensing - Fully configurable via PC
- 3-phase mains (utility) - Extremely efficient power - 3-phase mains (utility) using USB communication
sensing save mode sensing - Front panel configuration
- Compatible with 600 V AC - 3-phase generator sensing - Generator/load power - Efficient power save mode
Ph to Ph nominal systems - 3-phase mains (utility) monitoring (kW, kV A, kV - 3-phase generator sensing
- Fuel and start outputs sensing Ar, pf) - 3-phase mains (utility)
- 7 configurable digital inputs - Compatible with 600 V ph - - Generator overload sensing
- Configurable staged loading ph nominal systems protection (kW) - Generator/load power
outputs - Generator/load power - Generator/load current monitoring (kW, kV A, kV
- Alternator speed sensing monitoring (kW, kV A, kV monitoring and protection Ar, pf)
- 3 engine maintenance alarms Ar, pf) - Breaker control via fascia - Generator/load current
- Engine speed protection - Generator overload buttons monitoring and protection
- Engine hours counter protection (kW) - Fuel and start outputs, - Breaker control via fascia
- Engine pre-heat - Generator/load current configurable when using buttons
- Engine run-time scheduler monitoring and protection CAN - Fuel and start outputs,
- Battery voltage monitoring - Fuel and start outputs - 4 configurable DC outputs configurable when using
- Start on low battery voltage (configurable when using - 4 configurable analogue/ CAN
- Configurable remote start CAN) digital inputs - 4 configurable DC outputs
input - 4 configurable DC outputs - 6 configurable digital inputs - 4 configurable analogue/
- 1 alternative configuration - 3 configurable analogue/ - Support for 0-10 V & 4-20 digital inputs
- Comprehensive warning, digital inputs mA oil pressure sensors - Support for 0 to10 V & 4 to
electrical trip or shutdown - 4 configurable digital inputs - Configurable staged loading 20 mA oil pressure sensors
protection upon fault - Configurable staged loading outputs - 6 configurable digital inputs
condition outputs - CAN, MPU and alternator - Configurable staged loading
- Event log (15) - CAN and alternator speed speed sensing in one variant outputs
+ many more features sensing in one variant - 3 engine maintenance alarms - CAN, MPU and alternator
- 3 engine maintenance alarms - Engine speed protection speed sensing in one variant
- Engine speed protection - Engine hours counter - 3 engine maintenance alarms
- Engine hours counter - Engine pre-heat - Engine speed protection
- Engine pre-heat - Engine run-time scheduler - Engine hours counter
- Engine run-time scheduler - Engine idle control for - Engine pre-heat
- Engine idle control for starting & stopping - Engine run-time scheduler
starting & stopping - Fuel pump control - Engine idle control for
- Battery voltage monitoring - Real-time clock starting & stopping
- Start on low battery voltage - Battery voltage monitoring - Fuel pump control
- Configurable remote start - Start on low battery voltage - Real-time clock
input - Configurable remote start - Battery voltage monitoring
- 1 alternative configuration input - Start on low battery voltage
- Comprehensive warning, - 1 alternative configuration - Configurable remote start
electrical trip or shutdown - Comprehensive warning, input
protection upon fault electrical trip or shutdown - 1 alternative configuration
condition protection upon fault - Comprehensive warning,
- LCD alarm indication condition electrical trip or shutdown
- Event log (50) - LCD and LED alarm protection upon fault
+ many more features indication condition
- Configurable event log (50) - LCD and LED alarm
+ many more features indication
- Customisable information
screens
+ many more features
DSEGenset ®

NEW

DSE7120 MKII DSE7320 MKII DSE7420


- Large back-lit icon display - 4-line back-lit LCD text - Manual and automatic fuel - Configurable inputs (11)
- Heated display option display pump control - Configurable outputs (8)
available - Multiple display languages - Engine pre-heat and post- - Voltage measurement
- Fully configurable via the - Five-key menu navigation heat functions - Mains (utility) failure detection
fascia or PC using USB - LCD alarm indication - Engine run-time scheduler - Dedicated load test button
communication - Heated display option - Engine idle control for - kW overload alarms
- Extremely efficient power available starting & stopping - Comprehensive electrical
save mode - Customisable power-up text - Fuel usage monitor and low protection
- 3-phase generator sensing and images fuel level alarms - RS232, RS485 & Ethernet
- 3-phase mains (utility) - DSENet® expansion - Simultaneous use of RS232 remote communications
sensing compatibility and RS485 communication - MODBUS RTU/TCP
- Generator/load power - Data logging facility ports - PLC functionality
monitoring (kW, kV A, kV - Internal PLC editor - True dual mutual standby - Multi event exercise timer
Ar, pf) - Protections disable feature using RS232 or RS485 - Back-lit LCD 4-line text
- Generator overload - Fully configurable via PC for accurate engine hours display
protection (kW) using USB, RS232 & RS485 balancing. - Multiple display languages
- Generator/load current communication - MODBUS RTU support with - Automatic start/manual start
monitoring and protection - Front panel configuration configurable MODBUS pages - Audible alarm
- Fuel and start outputs with PIN protection - Advanced SMS messaging - Fixed and flexible LED
(configurable when using - Power save mode (additional external modem indicators
CAN) - 3-phase generator sensing required) - Event log (250)
- 4 configurable DC outputs and protection - Start & stop capability via - Engine protection
- 2 configurable volt-free - 3-phase mains (utility) SMS messaging - Fault condition notification to
outputs sensing and protection - 3 configurable maintenance a designated PC
- 4 configurable analogue/ (DSE7320 MKII only) alarms - Font panel mounting
digital inputs - Automatic load transfer - Compatible with a wide - Protected front panel
- 6 configurable digital inputs control (DSE7320 MKII only) range of CAN engines, programming
- Configurable staged loading - Generator current and power including tier 4 engine - Configurable alarms and
outputs monitoring (kW, kvar, kVA, pf) support timers
- CAN, MPU and alternator - Mains (utility) current and - Uses DSE Configuration - Configurable start and stop
speed sensing in one variant power monitoring (kW, kvar, Suite PC Software for timers
- 3 engine maintenance alarms kVA, pf) (DSE7320 MKII only) simplified configuration - Five-key menu navigation
- Engine speed protection - kW and kvar overload and - Licence-free PC software - Front panel editing with PIN
- Engine hours counter reverse power alarms - IP65 rating (with supplied protection
- Engine pre-heat - Over current protection gasket) offers increased - 3 configurable maintenance
- Engine run-time scheduler - Unbalanced load protection resistance to water ingress alarms
- Engine idle control for - Independent earth fault - Modules can be integrated - CAN and Magnetic Pick-up/
starting & stopping protection into building management Alt. sensing
- Battery voltage monitoring - Breaker control via fascia systems (BMS) using - Fuel usage monitor and low
- Start on low battery voltage buttons MODBUS RTU fuel alarms
- Real-time clock - Fuel and start outputs + many more features - Charge alternator failure
- Fuel pump control configurable when using alarm
- Configurable remote start CAN - Manual speed control (on
input - 6 configurable DC outputs compatible CAN engines)
- 1 alternative configuration - 2 configurable volt-free relay - Manual fuel pump control
- Comprehensive warning, outputs - “Protections disabled”
electrical trip or shutdown - 6 configurable analogue/ feature
protection upon fault digital inputs - Reverse power protection
condition - Support for 0 V to 10 V & 4 - Power monitoring (kW h, kV
- LCD and LED alarm mA to 20 mA sensors Ar, kV A h, kV Ar h)
indication - 8 configurable digital inputs - Load switching (load
- Event log (50) - Configurable 5 stage dummy shedding and dummy load
+ many more features load and load shedding outputs)
outputs - Automatic load transfer
- CAN, MPU and alternator - Unbalanced load protection
frequency speed sensing in - Independent earth fault trip
one variant - Integral PLC editor
- Real-time clock + many more features
DSEGenset ®

SYNCHRONISING & LOAD SHARING


CONTROL MODULES
NEW NEW

DSE8610 MKII DSE8620 DSE8660 MKII DSE8680


- Comprehensive - Mains (utility) failure detection - Mains (utility) failure detection - Comprehensive
synchronising & loadsharing - Comprehensive - Mains (utility) power synchronising & loadshare
capabilities synchronising & loadsharing monitoring capabilities
- Built in governor and AVR capabilities (kW, kV Ar, kV A and pf) - Connects to two DSE MSC
control - Built-in governor and AVR - Peak lopping & shaving links, one for ‘bus 1’ and
- Base load (kW export) control functionality another for ‘bus 2’
control - Base load (kW export) - Mains (utility) kW export - Advanced integral PLC editor
- Positive & negative kVAr functionality protection - 11 configurable inputs
export control - Peak lopping & shaving - Comprehensive - 8 configurable outputs
- 4-line back-lit LCD text functionality synchronising and - DSENet® expansion
display - Mains (utility) power (kW, kV loadsharing capabilities compatibility
- Multiple display languages Ar, kV A & pf) monitoring - Base load (kW export - User configurable RS232,
- Five-key menu navigation - Mains (utility) decoupling functionality RS485 & Ethernet
- LCD alarm indication protection - Positive & negative kVAr communications
- Heated display option - Generator power (kW, kV Ar, export control - Remote SCADA monitoring
available kV A & pf) monitoring - Mains (utility) decoupling via various DSE software
- Customisable power-up text - Overload (kW & kV Ar) protection applications
and images protection - Mains (utiltiy) and bus - MODBUS RTU & TCP
- DSENet® expansion - Reverse power (kW & kV Ar) positive, negative and zero support
compatibility protection sequence voltage alarms - User configurable MODBUS
- Data logging & trending - Mains (utility) kW export - Mains (utility) and bus neutral pages
facility protection voltage displacement (NVD) - Advanced SMS control and
- Internal PLC editor - Unbalanced load protection alarms fault messaging (additional
- Protections disable feature - Independent earth fault + many more features GSM modem required)
- Fully configurable via PC protection - Easy access diagnostic
using USB, RS232, RS485 - Advanced integral PLC editor pages including modem
& Ethernet communication - 11 configurable inputs diagnostic pages
- Front panel configuration - 8 configurable outputs - Data logging and trending
with PIN protection - Configurable flexible sensor - Front panel editing with PIN
- Power save mode inputs protection
- 3-phase generator sensing - DSENet® expansion - Fully configurable using
and protection compatibility DSE Configuration Suite PC
- Generator current and power - User configurable RS232, Software via USB
monitoring (kW, kvar, kVA, pf) RS485 and Ethernet - 4-line back-lit LCD text
- kW and kvar overload alarms communications DSE8661 display
- Reverse power alarms - Remote SCADA monitoring Mains (Utility) & Bus Breaker - LED and LCD alarm
- Over current protection via various DSE software Control Module indication
- Unbalanced load protection applications - Mains (utility) failure detection - Configurable display
- Independent earth fault - MODBUS RTU & TCP - Mains (utility) power languages
protection support monitoring (kW, kV Ar, kVA - Customisable status screens
- Breaker control via fascia - User configurable MODBUS and pf) - Configurable event log (250)
buttons pages - Comprehensive - Backed up real-time clock
- Fuel and start outputs - Advanced SMS control and synchronising and + many more features
configurable when using fault messaging (additional loadsharing capabilities
CAN GSM modem required) - Peak lopping & shaving
- 8 configurable DC outputs - Easy access diagnostic functionality
- 2 configurable volt-free relay pages including modem - Mains (utility) kW export
outputs diagnostic pages protection
- 4 configurable analogue/ - Data logging and trending - Mains (utility) decoupling
digital inputs - CAN, MPU and frequency protection
- Built in sensors to support speed sensing - Advanced integral PLC editor
0 V to 10 V & 4 mA to 20 mA - Tier 4 CAN engine support - User configurable RS232,
- 12 configurable digital inputs - “Protections disabled” RS485 & Ethernet
- Configurable 5 stage dummy feature communications
load - Front panel editing with PIN - MODBUS RTU & TCP
+ many more features protection support
+ many more features + many more features
DSEGenset ®

DSE8710/60 DSE8721 DSE8810 DSE8860


- Peak lopping (When connected to host - Colour LCD graphical display - Colour LCD graphical display
- Sequential set start module) - Sequential set start - Peak lopping
- Manual voltage/frequency - RS232, RS485 & Ethernet - R.O.C.O.F. and vector shift - Sequential set start
adjustment communications - Generator load demand - Manual voltage/frequency
- R.O.C.O.F. and vector shift - Audible alarm - Automatic hours run adjustment
- Generator load demand - Engine protection balancing - R.O.C.O.F. and vector shift
- Automatic hours run - Fault condition notification - Dead bus sensing - Generator load demand
balancing to a designated PC - Bus failure detection - Automatic hours run
- Mains (Utility) decoupling - Front panel mounting - Direct governor and AVR balancing
- Dead bus sensing - Protected front panel control - Mains (Utility) decoupling
- Mains (Utility) decoupling configuration - Volts and frequency - Mains (Utility) decoupling
test mode - Configurable alarms and matching test mode
- Bus failure detection timers - kW and kV Ar load sharing - Bus failure detection
- Direct governor and AVR - Configurable start and stop - Comprehensive loadshare - Volts and frequency
connections/controls timers capabilities matching
- Volts and frequency - SMS alert messaging - Configurable inputs (12) - Colour LCD graphical display
matching - Remote monitoring - Configurable outputs (10) - Configurable digital inputs
- kW and kV Ar load sharing - Data communication link - Voltage measurement (12)
- Independent display screen allows remote system - Built-in governor and AVR - Configurable outputs (10)
options management control - Configurable flexible sender
- Configurable inputs (11) - 800 x 480 pixel screen - kW overload alarms inputs (2)
- Configurable outputs (8) for high clarity - Comprehensive electrical - Comprehensive electrical
- Voltage measurement + many more features protection protection
- Built-in governor and AVR - Magnetic pick-up - Comprehensive loadshare
control - Electronic engine capability capabilities
- kW overload alarms - RS232, RS485 & Ethernet - Mains (utility) fail sensing
- Comprehensive electrical remote communications - Multiple mains (utility)
protection - Two RS485 ports monitoring
- Magnetic pick-up/Alt. - MODBUS RTU - Peak lopping
sensing - PLC functionality - Peak shaving
- Electronic engine capability - Multi event exercise timer - RS232, RS485 & Ethernet
- RS232 & RS485 remote - Back-lit LCD graphical remote communications
communications display - MODBUS RTU/TCP support
- MODBUS RTU & TCP - Multiple display languages - Configurable display
- PLC functionality DSE8711/16 - Automatic start/manual start languages
- Multi-event exercise timer - RS232, RS485 & Ethernet - Audible alarm - Audible alarm
- Automatic start/manual start communications - Reduced file transfer time - Reduced file transfer time
- Event log (250) - Audible alarm - Fixed and flexible LED - Fault condition notification to
- Engine protection - Engine protection indicators a designated PC
- Fault condition notification to - Fault condition notification to - Event log (250) - Compatible with DSE8700 &
a designated PC a designated PC - Engine protection DSE8600 Series
- PC configuration - Front panel mounting - Fault condition notification - Front panel editing with PIN
- Configurable alarms and - Protected front panel to a designated PC protection
timers configuration - Protected front panel - Configurable timers and
- Configurable start and stop - Configurable alarms and programming alarms
timers timers - PC configuration - Multiple date and time
- SMS alert messaging - Configurable start and stop - Fully configurable scheduler
- Remote monitoring timers - SMS alert messaging - Configurable event log (250)
- Compatible with DSE8600 - SMS alert messaging - Compatible with DSE8700 - Easy access diagnostic page
Series - Remote monitoring & DSE8600 Series - kW overload protection
+ many more features - Data communication link + many more features - Reverse power protection
allows remote system - Power monitoring (kW h, kV
management Ar, kV A h, kV Ar h)
+ many more features - USB connectivity
- Backed up real-time clock
+ many more features
DSEGenset ®

ENGINE ONLY DC GENERATOR MAINS/UTILITY


CONTROL MODULES CONTROL MODULE DECOUPLING RELAY

Suitable for a wide range of applications such as engine


driven pumps, compressors, hydraulic power packs and
off highway machinery.

DSE7450 DSEP100
- Configurable inputs (10) Used to detect and protect
- Configurable outputs (8) a wide range of devices
DSEE400 DSEE800 - Configurable maintenance generating power in parallel
- Built-in governor control - Built-in governor control alarms (3) with the mains (utility) supply,
- Automatic speed control - Automatic speed control - Configurable battery including diesel generators,
- Fill, empty, maintain fill and - Manual speed control via maintenance alarms (3) photovoltaic [solar] installations
maintain empty control push buttons, digital input or - Configurable alarms and and wind turbines etc.
- Manual speed control via analogue input timers - Designed to assist with
push buttons, digital input or - Automatic speed ramping - Automatic or manual start integration with a number of
analogue input - Flexible automatic start with configurable start and world standards including
- Automatic speed ramping control stop timers G59/2, G83/2 C10/11 &
- Flexible automatic start - Clutch control - 2 DC shunt inputs CEO10-21
control - 4-line back-lit LCD text (Configurable 0-250mV - Two-stage under & over
- Clutch control display and 0-5000 A) voltage protection
- LCD text display - Multiple display languages - AC & DC voltage - 10 second rolling average
- Multiple display languages - Five-key menu navigation measurement over voltage protection
- Two-key menu navigation - Front panel editing with PIN - Mains (utility) failure detection - Two-stage under & over
- Front panel editing with PIN protection - Dedicated load test button frequency protection
protection - Customisable status screens - kW overload alarms - Voltage asymmetry
- Customisable status screens - Power save off mode - Comprehensive electrical protection
- Customisable multi - Configurable digital inputs protection - Vector shift protection
instrumentation screens (11) + many more features + many more features
- Configurable digital inputs (4) - Configurable ratiometric
- Configurable analogue inputs (12)
inputs (7) - Configurable DC outputs (4)
- Configurable DC outputs (2) - Configurable volt-free LIGHTING TOWER DIGITAL AUTOMATIC
- Configurable PWM/PWMi outputs (2) CONTROL MODULE VOLTAGE REGULATOR
outputs (2) - Configurable PWM outputs
- Configurable analogue (4)
output (1) - Configurable timers and
- Configurable timers and alarms NEW
alarms - 3 configurable maintenance
- 3 configurable maintenance alarms
alarms - Multiple date and time engine DSEL401MKII DSEA106
- Multiple date and time engine scheduler - Lighting tower controller - Soft start ramping
scheduler - Configurable event log (250) - 4 new timers for lamp - Under frequency roll off
- Configurable event log (250) - CAN engine support outputs (UFRO) protection
- CAN engine support - Advanced integral PLC editor - Auto & manual mast control - Loss of voltage sensing
- CAN, magnetic pick-up or - CAN, magnetic pick-up or screens protection
tachometer speed sensing tachometer speed sensing - New screen for light - Over excitation protection
- Fuel usage monitor and low - Fuel usage monitor and low sequence control - Remote voltage adjustment
fuel alarms fuel alarms - Flexible input with fuel level using 0 V to 10 V signal and
- Charge alternator failure - Charge alternator failure option 5 kΩ potentiometer.
alarm alarm - Options: metering or non- - DIP switch selection for
- “Protections disabled” - Manual fuel pump control metering versions voltage, frequency and
feature - “Protections disabled” - Up to four individually stability ranges.
- LCD alarm indication feature configurable outputs for - Potentiometer adjustment
- Low power mode - LED and LCD alarm switching on and off lighting for voltage set points, droop,
- USB connectivity indication circuits UFRO, proportional and
- Backed-up real time clock - USB connectivity - Phased shutdown of non integral gain
- Fully configurable via DSE - Backed-up real time clock essential lighting circuits as + many more features
Configuration Suite PC - Fully configurable via DSE fuel decreases
Software Configuration Suite PC - Lamp / Light failure circuit
+ many more features Software detection via current
+ many more features monitoring
- Eight event scheduler
+ many more features
DSEGenset ®

EXPANSION
MODULES

DSE103MKII DSE124 DSE2130 DSE2131


- Configurable trip points - Extends MSC load share link - Input expansion module for - Ratiometric input expansion
- Configurable nominal speed or engine CANbus DSENet® compatible control module for supported
- Trip points can be configured - 4 LEDs for operational status modules DSENet® controllers
to be latching or non-latching indication - 4 configurable inputs, 4 - 10 inputs configurable for
- Analogue meter output - Fibre optic and non fibre digital inputs digital/resistive 4-20 mA and
- Potted enclosure optic variants - Power on/link lost LED 0-10 V DC
- Spade terminals for easy - Up to 200 meter range - 4 modules can be connected - Power on/link lost LED
connection between extenders to 1 host controller - A maximum of 4 modules
+ many more features - Simplified configuration - Works up to 1.2 km can be connected to 1 host
using DSE PC Configuration (0.75 miles) from the host control module to provide up
Suite Software (free) controller to 40 additional configurable
+ many more features + many more features inputs
- Works up to 1.2 km
(0.75 miles) from the host
controller
- Terminal strip connection for
quick and easy set-up
- Simplified configuration
using DSE PC Configuration
DSE123 DSE125 Suite Software (free)
- Load Share lines interface - Makes the DSE75xx MSC + many more features
- Expand existing systems link compatible with the 8xxx
with DSE modules without modules
replacing existing control - Simplified configuration
- kW & kV Ar loadsharing using DSE PC Configuration
between DSE & other Suite Software (free)
manufacturers products + many more features
Power on/status LED
+ many more features

DSE2133 DSE2152 DSE2157 DSE2548


- Input expansion module for - Analogue output expansion - Output relay expansion - LED expansion module for
supported DSENet® module for supported module for DSENet® DSENet® compatible control
controllers DSENet® controllers compatible control modules modules
- 8 inputs configurable for - 8 outputs configurable as - 8 configurable relay contacts - 8 configurable LEDs
J-type/K-type thermocouple, 4-20/mA (0-20) and with LED indicators: - Works up to 1 km (0.6 miles)
PT 100, 3 wire RTD sensors 0-10 V AC - 4 normally open (N/O) from the host controller
- Power on/link lost LED - Power on/link lost LED - 4 change over (C/O) - 10 modules can be linked
- 4 modules can be connected - A maximum of 4 modules - Power on/link lost LED ID together to one host
to 1 host controller to provide can be connected to 1 host SWITCH controller to provide up to
up to 32 additional inputs control module to provide up - 10 expansion modules 80 LEDs
- Works up to 1.2 km (0.75 to 32 additional configurable can be connected to 1 host - Simplified configuration
miles) from the host module outputs controller at a time using DSE PC Configuration
- Terminal strip connection for - Works up to 1.2 km (0.75 - Works up to 1.2 km (0.75 Suite Software (free)
quick and easy set-up miles) from the host controller miles) from the host controller + many more features
- Simplified configuration - Terminal strip connection for - Terminal strip connection for
using DSE PC Configuration quick and easy set-up quick and easy set-up
Suite Software (free) - Simplified configuration - Simplified configuration
+ many more features using DSE PC Configuration using DSE PC Configuration
Suite Software (free) Suite Software (free)
+ many more features + many more features
DSEAts ®

AUTO TRANSFER
SWITCH

DSE330 DSE331 DSE334 DSE335


- Configurable inputs (2) - Configurable inputs (4) - Volt-free relays - Configurable inputs (12)
- Configurable outputs (6) - Configurable volt-free - Supports many topologies - Configurable volt-free
- Icon or english text display outputs (4) - Automatic switch-over outputs (6)
- LED indicator - Configurable DC outputs (4) between supplies - Configurable DC outputs (6)
- Front panel/PC configuration - Check sync feature - Check sync feature - 4-line back-lit LCD text
- Source 1/source 2 control - Icon and english text display - Real-time clock display
- Configurable timers - LED indicator - 10 configurable inputs - Five-key menu navigation
- Start inhibit - Front panel/PC configuration - 5 configurable outputs - Front panel editing with PIN
- Load inhibit - Remote monitoring - Event log (10) protection
- Manual restore to S1 - Source 1/source 2 control - Configurable timers - LED and LCD alarm
- Supports multiple topologies - Configurable timers - Automatic shutdown indication
- Automatic switch-over - Start inhibit or warning when fault - Check sync feature
between supplies - Load inhibit conditions are detected - Passive closed transition
- Rotary ATS configuration - Manual restore to S1 - PC configuration - Remote monitoring
- Single event scheduler - Supports multiple topologies - Front panel configuration - Source 1/source 2 control
- Single-phase display - Automatic switch-over - LED indicators - 1 A & 5 A CT secondary
+ many more features between supplies - Back-lit 4-line text LCD support
- Rotary ATS configuration display - Phase rotation detection
- Single event scheduler - External mains (utility) or - Start inhibit
- 3-phase display genset failure inputs - Load inhibit
+ many more features - Auto start inhibit - Manual restore to S1
- Load inhibit - Supports multiple topologies
- Manual restore to S1 - Automatic switch-over
- Optional current monitoring between supplies
+ many more features - Rotary ATS configuration
- Configurable timers and
alarms
- Multiple date and time
scheduler
- Power monitoring (kW h, kV
Ar, kV A h, kV Ar h)
- Load switching (load
shedding outputs)
- USB connectivity
- Backed up real-time clock
- Fully configurable via DSE
Configuration Suite PC
Software
- Configurable display
languages
- User selectable RS232 and
DSE160 RS485 communications
- 12 V and 24 V options - Configurable Gencomm
- LED Indication pages
- Can be used as an AC-DC - SMS messaging (additional
power supply external modem required)
- Can be powered from mains - Additional display screens to
(utility), generator or battery help with modem diagnostics
- Wide operating input voltage - DSENet® expansion
- Output auto restart short circuit compatible
protection - Integral PLC editor
- Output over voltage protection - Adjustable MODBUS
- Less than 1% output ripple inter-frame delay
+ many more features + many more features
DSEAts ®

DSEAts ®

High Demand. High Quality.


A major european data centre that features multiple complex loads and
two mains (utility) supplies, uses DSE335 ATS modules for changeover
control.

The data centre facility is supplied by two mains (utility) power sources.
One primary supply (S1) and a smaller secondary supply (S2). The
load is split into a number of individual loads, each monitored by
a dedicated DSE335, which simultaneously monitors both power
sources. This allows extreme fluctuations in demand to be managed
effectively, with changeover to one supply or the other dependant on
the demand on each load and condition of S1 & S2.

The DSE335 modules communicate activity and status to a common


PLC. Using this information, the PLC at a pre-defined trigger point will
issue a command to the chosen DSE335 to switch it’s load to
the alternative power supply. The module then handles the transfer.

www.deepseaplc.com
DSEPower ®

INTELLIGENT BATTERY CHARGERS


MULTI-STAGE INTELLIGENT CHARGING
HIGH POWERED ENCLOSED

NEW

NEW

Configurable Voltage DSE9474 24V 30A DSE9450 48V 50A DSE9460 12/24V 5A
DSE9470MKII 24V (12V) 10A - Remote voltage sensing to DSE9452 24V 50A DSE9461 12/24V 10A
DSE9472MKII 24V (12V) 5A compensate for voltage drop DSE9479 24V 100A - Configurable to suit most
DSE9480MKII 12V (24V) 10A - Adjustable current limit - Remote voltage sensing to battery types (12 V/24 V)
DSE9481MKII 12V (24V) 5A (Maximum 30 A) compensate for voltage drop - Adjustable current limit
Fixed Voltage - Can be used as a battery - Adjustable current limit - Can be used as a battery
DSE9473 24V 15A NEW charger, power supply or (Maximum 50 A) charger, power supply or
DSE9483 12V 15A NEW both at the same time - Can be used as a battery both at the same time
DSE9476 24V 20A R&D - Automatic or manual boost charger, power supply or - Automatic or manual boost
- Adjustable current limit and storage charge functions both at the same time and storage charge functions
- Can be used as a battery to help maintain battery - Additional auxiliary 12 V to help maintain battery
charger, power supply or condition supply output condition
both at the same time - Digital microprocessor - Automatic or manual boost - Digital microprocessor
- Automatic or manual boost technology and storage charge functions technology
and storage charge functions - Temperature compensation to help maintain battery - Temperature compensation
to help maintain battery for battery charging condition for battery charging
condition - Low output ripple and - Digital microprocessor - Low output ripple and
- Digital microprocessor superb line regulation technology superb line regulation
technology - Three LED indicators - Temperature compensation - Available in a number of
- Temperature compensation - AC input under voltage for battery charging display variants (LEDs,
for battery charging - AC input over voltage - Low output ripple and analogue meters, LCD
- Low output ripple and - Battery charger output over superb line regulation display)
superb line regulation voltage - Three LEDs indication Full Protection
- Three LED indicators - Battery charger output over Full Protection - AC input under voltage
Full Protection current - AC input under voltage - AC input over voltage
- AC input under voltage - Battery low voltage detection - AC input over voltage - Battery charger output over
- AC input over voltage - Battery temperature - Battery charger output over voltage
- Battery charger output over compensation with over voltage - Battery charger output over
voltage temperature protection - Battery charger output over current
- Battery charger output over - Output short-circuit and current - Battery temperature
current inversion polarity with auto - Battery low voltage detection compensation with over
- Output short-circuit and recovery - Battery temperature temperature protection
inversion polarity with auto - Automatic power de-rating at compensation with over - Output short-circuit and
recovery high ambient temperatures temperature protection inversion polarity with auto
- Automatic power de-rating at - Optional battery temperature - Output short-circuit and recovery
high ambient temperatures compensation using PT1000 inversion polarity with auto - Automatic power de-rating at
- Optional battery temperature temperature sensor recovery high ambient temperatures
compensation using PT1000 + many more features - Automatic power de-rating at - Battery charger failure
temperature sensor with over high ambient temperatures. indication
temperature protection - Optional battery temperature Automatic Boost Mode
Automatic Boost Mode compensation using PT1000 - Boosts and equalises cell
- Boosts and equalises cell temperature sensor charge improving battery
charge improving battery Automatic Boost Mode performance and life
performance and life - Boosts and equalises cell Power Save Mode
Power Save Mode charge improving battery - Once the battery is fully
- Once the battery is fully performance and life charged the chargers switch
charged the chargers switch Power Save Mode to ecopower to save energy
to ecopower to save energy - Once the battery is fully Communication
Communication charged the chargers switch - Can be integrated into
- Can be integrated into to ecopower to save energy external systems through
external systems through Communication MODBUS RTU using RS485
MODBUS RTU using RS485 - Can be integrated into - Fully configurable via DSE
- Fully configurable via DSE external systems through Configuration Suite PC
Configuration Suite PC MODBUS RTU using RS485 Software
Software & J1939 using CANBUS + many more features
- External remote LCD option + many more features
- DSE2541
+ many more features
DSEPower ®

BATTERY CHARGERS
SWITCH MODE REMOTE DISPLAY POWER SUPPLY

DSE9130 12V 5A DSE9701 24V 5A DSE2541 DSE160


DSE9150 12V 3A DSE9702 12V 5A - Large back-lit icon display - 12 V and 24 V options
DSE9155 30V 2A Space-saving vertical 5 amp - Compatible with DSE94xx - LED indication
DSE9255 24V 5A battery charger for compact battery chargers - Can be used as an AC-DC
Multi-Stage Charging panel designs - Fascia configuration for power supply
- Constant current/maximum Multi-Stage Charging connected battery charger - Can be powered from mains
current available during - Constant current/maximum - LCD alarm indication (utility), generator or battery
charge recovery phase current available during - 1 volt-free change-over - Wide operating input voltage
- Constant voltage charge recovery phase fault output - Output auto restart short-
- Chargers automatically return - Constant voltage - Remote battery charger circuit protection
to float mode when charging - Charger automatically returns and charge cycle monitoring - Output over voltage protection
is complete to float mode when charging - Remote boost and battery - Less than 1% output ripple
Low Output Ripple is complete charger output control + many more features
- Makes the chargers ideal for Low Output Ripple - Remote battery
all battery types - Makes the charger ideal for charger configuration without
Full Protection all battery types the need for a computer
- Reverse polarity protection, Full Protection + many more features
short-circuit protection and - Reverse polarity protection,
current limiting short-circuit protection and
- Automatic recovery after the current limiting
removal of fault conditions - Automatic recovery after the
Boost Mode removal of fault conditions
- Boosts and equalises cell - Battery charger thermal
charge improving battery de-rate facility
performance and life Boost Mode
- Simple boost connection - Boosts and equalises cell
using on-board terminals charge improving battery
Power Save Mode performance and life
- Once the battery is fully - Simple boost connection
charged the chargers switch using on-board terminals
to ecopower to save energy - Battery charger thermal
+ many more features de-rate facility (9701/9702)
Power Save Mode
- Once the battery is fully
charged the chargers switch
to ecopower to save energy
+ many more features

DUAL OUTPUT

- Can be used as a battery - Battery charger output over Power Save Mode
NEW charger, power supply or current - Once the battery is fully
both at the same time - Battery low voltage detection charged the chargers switch
- Automatic or manual boost - Output short circuit and to ecopower to save energy
and storage charge functions polarity inversion with auto Communication
to help maintain battery recovery - Can be integrated into
condition - Automatic power de-rating at external systems through
DSE9462 - Digital microprocessor high ambient temperatures. J1939 using CANBUS
24V 15A, 12V 10A technology - Optional battery temperature - Fully configurable via DSE
- Remote voltage sensing to - Low output ripple compensation using PT1000 Configuration Suite PC
compensate for voltage drop - Four LED indicators temperature sensor Software
- Fully independent, adjustable Full Protection Automatic Boost Mode + many more features
current limit on both charge - AC input under voltage - Boosts and equalises cell
outputs; Output 1 (24 V) - AC input over voltage charge improving battery
max 15 A, Output 2 (12 V) - Battery charger output over performance and life
max 10 A voltage
DSECommunications

DSE8004
- 10” colour touch-screen technology
- Widget based information displays
- Dual core processor for ultimate speed and efficiency
- Highly sophisticated level of instrumentation & alarms
- Supports 86xx, 87xx & 88xx control modules
+ many more features

DSE8003
(When connected to compatible modules)
- Multiple modules (up to a maximum of 20) within
the same load sharing system can be viewed
- Touch-screen enabled
- RS232, RS485 and Ethernet communications
- Audible alarm
- Front panel mounting
DSE2510/2520 - Protected front panel configuration
- Expands the application possibilities of the DSE73xx - Remote monitoring
series by offering remote control and monitoring from - System monitoring
up to 3 separate locations - Compatible with DSE86xx, DSE87xx & DSE88xx
- Works up to 1.2 km (0.75 miles) from the host module load share control modules
- Simplified configuration using DSE PC Configuration - Data communication link allows remote system
Suite Software (free) management
+ many more features - 800 x 480 pixel screen for high clarity
+ many more features
DSE8005 DSE855/857
- SCADA Suite software for Windows™ PC enables remote - Communications devices for DSE modules
control and monitoring of DSE load share systems without built-in Ethernet communications
- Touchscreen PC enabled - Converts USB to Ethernet
- Engine start/stop - Converts USB to RS485
- Monitoring and control
- Switching on and off load
- Load demand priority
- Mains (utility) base load power levels
- System overview graphical designer with simple drag and
drop facility
- 32/64-bit operating system

DSE890/891 WebNet Gateway DSE892 SNMP Gateway


- Gateway devices for DSEWebNet® communications - Supports a wide range of DSE controllers
- Sophisticated Ethernet/GSM web-based remote - Status LEDs for each communication port
communications for supported DSE controllers - Plug and socket connections and DIN rail mounting for
- Low cost solution for secure and effective remote quick and easy set up
monitoring and control for multiple users and multiple sites - Email/SNMP TRAP messages upon controller events and
- Comprehensive on-screen information presented in clear, operating status change
graphical and numerical formats - Fully customisable email / SNMP TRAPs based upon
- Global mapping shows multiple site locations module instrumentation values
- Comprehensive aerial screen views show detailed site - Simple configuration via internet browser – No additional
information PC software required
- Multiple or single site generator event recording & - Automatically generated MIB file to ease system
monitoring integration, downloadable directly from the DSE892
- Real-time instrumentation and control - Email by SMTP client
- Event log tables - A single DSE892 SNMP Gateway can be connected to
- Automatic system alerts which are sent to multiple multiple controllers
DSEWebNet® users via email and SMS - Monitoring of controller state, operating mode and alarms
- Firmware upgradeable direct via USB memory stick or
OTA (Over the Air) from DSE server
COMPLETE POWER
MANAGEMENT
SOLUTIONS
MULTIPLE LOADS,
MULTIPLE SOURCES,
MULTIPLE APPLICATIONS.

DSE7310MKII
Auto Start Control Module
Sophisticated genset control modules for single
and multi-set systems.

www.deepseaplc.com
DSE9450
50 Amp Intelligent Battery Charger
High powered intelligent battery chargers
for maximising battery life and efficiency.

DSE335
Auto Transfer Switch Module
Dedicated auto transfer switch control
modules for demanding applications.
INTELLIGENT SINGLE-SET
GENERATOR CONTROL

DSE7310 MKII
Intelligent Single-Set Generator Control
– Configurable front panel editor with – Dual mutual standby over communications.
password protection. – Preheat based on temperature.
– Simultaneous communications. – J1939 - 75 support.
– Data logging.
– Six fully flexible analogue inputs. + Many more outstanding NEW features.
– Two on-board ratiometric inputs (0-10V/4-
20mA configurable).

www.deepseaplc.com
Application
DSE modules deliver
outstanding performance
& reliability in the most
extreme conditions.

VIBRATION ELECTRICAL TEMPERATURE


SAFETY

ELECTRO-MAGNETIC HUMIDITY SHOCK


COMPATIBILITY

Our high performance and reliability levels


make our products suitable for a wide
variety of applications including telecoms,
data storage centres, mining, hospitals,
military, airports, manufacturing, industry
and leisure and tourism.

The following application examples show


typical systems using DSE control modules.
Application 1
Mains (Utility) Decoupling
Relay
DSEGenset® manual/auto start control modules (MS/AS) offer a broad range of
features from key start operation to sophisticated modules with remote control &
monitoring.

DSE2541 DSEPower®
BC / IBC

DSEGenset®
LS

DSE8610

DSEGenset®
P

DSEP100

Refer to the key features section of Key:


this guide for product specifications. (LS) – Synchronising & load sharing control modules
(P) – Protection
(BC) – Battery chargers
(IBC) – Intelligent battery chargers
Application 2 Application 3
Engine Only Standby Vehicle
System Charging
Many DSEGenset® manual/auto start control modules DSEPower® offers dual output charging designed
(MS/AS) can be utilised for engine only applications such specifically for emergency standby vehicles and
as pumps, compressors, stone crushers, conveyors and other dual output 12 or 24 volt applications.
winches etc.

DSEPower® DSE2541
BC / IBC

12V 24V

DSEGenset®
AS / MS

DSEE800

Drive output to: DSE9462


- Pump
- Compressor
- Stone crusher
- Winch
- Conveyor
+ many more

Key:
(MS/AS) – Manual/auto start control modules
(BC) – Battery chargers
(IBC) – Intelligent battery chargers

Refer to the key features section of Refer to the key features section of
this guide for product specifications. this guide for product specifications.
Application 4
Synchronising and
Load Sharing Systems
DSEGenset® synchronising and load sharing (LS) modules offer a range of highly
sophisticated features & functions in a simple, user-friendly format.

DSEPower® offers a range of battery chargers (BC) and intelligent battery chargers
(IBC) to ensure optimal battery performance and maximum battery life times.

DSEPower® DSE2541 DSEPower® DSE2541


BC / IBC BC / IBC

GEN 1 GEN 2

DSEGenset® DSEGenset®
LS LS

DSE8x10 DSE8x10

DSEGenset® DSE8x60
LS

Refer to the key features section of Key:


this guide for product specifications. (LS) – Synchronising & load sharing control modules
(BC) – Battery chargers
(IBC) – Intelligent battery chargers
Application 5
Synchronising and Load Sharing Systems
(Hospital Application Example)
DSEGenset® synchronising and load sharing (LS) modules offer a range of highly
sophisticated features & functions in a simple, user-friendly format.

DSEPower® offers a range of battery chargers (BC) and intelligent battery chargers
(IBC) to ensure optimal battery performance and maximum battery life.

DSEPower® DSE2541 DSEPower® DSE2541 DSEPower® DSE2541


BC / IBC BC / IBC BC / IBC

DSE8x10 DSE8x10 DSE8x10

DSE8x80 DSE8x80

DSE8x60 DSE8x60

Refer to the key features section of Key:


this guide for product specifications. (LS) – Synchronising & load sharing control modules
(BC) – Battery chargers
(IBC) – Intelligent battery chargers
Application 6
Manual Start and
Auto Start Systems
DSEGenset® manual/auto start control
modules (MS/AS) offer a broad range of
features from key start operation through
to sophisticated modules with remote
control & monitoring.

DSEPower® DSE2541
BC / IBC

DSEGenset®
AS / MS

Refer to the key features section of Key:


this guide for product specifications. (MS/AS) – Manual/auto start control modules
(BC) – Battery chargers
(IBC) – Intelligent battery chargers
Application 7
Auto Transfer
Switch Systems
DSEAts® modules are designed to
compliment a DSEGenset® controller to offer
automatic monitoring and transfer between
alternative power supplies.
DSEPower® DSE2541
Stepped load systems arte also achievable
BC / IBC
using DSEAts® modules.

DSEGenset®
DSEAts®
AS

DSEPower® DSE2541 DSEPower® DSE2541


BC / IBC BC / IBC

DSEGenset® DSEGenset®
DSEAts®
AS AS

Refer to the key features section of Key:


this guide for product specifications. (MS/AS) – Manual/auto start control modules
(ATS) – Automatic transfer switch control modules
(BC) – Battery chargers
(IBC) – Intelligent battery chargers
Application 8 Application 9
Auto Mains (Utility) Lighting Tower
Failure Systems Systems
DSEGenset® Auto mains (utility) failure DSEGenset® lighting tower control modules
control modules (AMF) offer single and (L) include options with or without metering.
three-phase monitoring options with a broad
range of features to suit simple and complex
applications.

DSEPower® DSE2541
BC / IBC

DSEGenset® DSEGenset®
AMF L

Key: Key:
(AMF) – Auto mains (utility) failure control modules (L) – Lighting tower control modules
(BC) – Battery chargers
(IBC) – Intelligent battery chargers

Refer to the key features section of Refer to the key features section of
this guide for product specifications. this guide for product specifications.
PROVIDING OUTSTANDING Providing customers and end
users with fast and efficient
WORLDWIDE SUPPORT TO OUR telephone and email assistance
CUSTOMERS IS EXTREMELY
IMPORTANT TO US. Ensuring all DSE support staff
and distributors deliver first
class support within individual
countries worldwide

Worldwide technical support


available 24/7

Delivering superior training &


support from our dedicated
Global Coverage UK training facility to enable
customers and end users to
& Support maximise their DSE product and
application knowledge

Dedicated
Phone/Email
Support

Local
On-Site DSE
Market
Support CUSTOMER
Support

24-Hour
Global Technical
Support
DSEE400 & DSEE800
The DSEE400 & DSEE800 are intelligently designed engine control
modules that provide flexible control and comprehensive monitoring
& protection features.

Each control module has been developed for use with standard
and electronic engines and can handle a wide range of applications
including engine driven pumps, compressors, hydraulic power packs
and off-highway machinery.

www.deepseaplc.com
REAL-TIME
INSTRUMENTATION
& CONTROL

DSEWebNet® is ‘free to use’ software


that allows users to remotely access DSE
controlled generators from any location with
an internet connection.

DSEWebNet® is the ideal solution for


efficient generator control, fault finding and
preventative maintenance providing remote
access to plant and machinery. The software
supports single and multi-set systems using
a range of devices. Users can map static
locations, access real time instrumentation
& control, view event log tables and receive

DSEWebNet® automatic system alerts.

Information can be viewed worldwide using


desktop, tablet and smart phone devices.

www.deepseaplc.com/webnet
DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS INC DEEP SEA ELECTRONICS
Highfield House 3230 Williams Avenue INDIA PVT LTD
Hunmanby Industrial Estate Rockford D 47
Hunmanby IL 61101-2668 Udyog Vihar Phase -V
North Yorkshire USA Gurgaon
YO14 0PH 122016
ENGLAND TELEPHONE HARYANA
+1 (815) 316 8706
TELEPHONE FACSIMILE
+44 (0)1723 890099 +1 (815) 316 8708
FACSIMILE EMAIL
+44 (0)1723 893303 sales@deepseausa.com
EMAIL
sales@deepseaplc.com

OUR DISTRIBUTOR NETWORK IS WELL ESTABLISHED


AND PROVIDES STOCK, SERVICE AND SUPPORT IN
YOUR LOCAL MARKETPLACE.

Full details of all DSE distributors can


be found on our website.

www.deepseaplc.com

YEARS OF EXCELLENCE
1975 - 2015

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change the
details shown in this product brochure without prior notice. The contents are intended for guidance only.
055-110/06/16 (6)

Вам также может понравиться